{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,7]],"date-time":"2025-04-07T22:24:46Z","timestamp":1744064686527},"reference-count":50,"publisher":"Walter de Gruyter GmbH","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,1,1]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>While considering the importance of the interface between amputees and prosthesis sockets, we study an anthropomorphic prosthesis socket whose size can be dynamically changed according to the requirements of the residual limb. First, we introduce the structure and function of the anthropomorphic prosthesis socket. Second, we study the dynamic model of the prosthesis system and analyze the dynamic characteristics of the prosthesis socket system, the inputs of an oscillometric pump, and the control mechanism of force-sensitive resistor (FSR) pressure signals. Experiments on 10 healthy subjects using the designed system yield an average detection result between 102 and 112 kPa for the FSR pressure sensor and 39 and 41 kPa for the oscillometric pump. Results show the function of the FSR pressure signal in maintaining the contact pressure between the sockets and the residual limb. The potential development of an auto-adjusted socket that uses an oscillometric pump system will provide prosthetic sockets with controllable contact pressure at the residual limb. Moreover, this development is an attractive research area for researchers involved in rehabilitation engineering, prosthetics, and orthotics.<\/jats:p>","DOI":"10.1515\/bmt-2015-0106","type":"journal-article","created":{"date-parts":[[2016,5,11]],"date-time":"2016-05-11T10:02:43Z","timestamp":1462960963000},"source":"Crossref","is-referenced-by-count":1,"title":["An anthropomorphic transhumeral prosthesis socket developed based on an oscillometric pump and controlled by force-sensitive resistor pressure signals"],"prefix":"10.1515","volume":"62","author":[{"given":"N.A. Abd","family":"Razak","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Gholizadeh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.","family":"Hasnan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.A. Abu","family":"Osman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.S. Mohd","family":"Fadzil","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"N.A.","family":"Hashim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"374","reference":[{"key":"ref271","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1682\/JRRD.2009.12.0197","article-title":"Prosthetic sockets stabilized by alternating areas of tissue compression and release","volume":"48","year":"2011","journal-title":"J Rehabil Res Dev"},{"key":"ref331","first-page":"3748","year":"2007","journal-title":"A gas-actuated anthropomorphic transhumeral prosthesis"},{"key":"ref441","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1186\/1475-925X-13-108","article-title":"Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure","volume":"13","year":"2014","journal-title":"Biomed Eng Online"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"679","DOI":"10.1682\/JRRD.2009.12.0197","article-title":"Prosthetic sockets stabilized by alternating areas of tissue compression and release","volume":"48","year":"2011","journal-title":"J Rehabil Res Dev"},{"key":"ref361","first-page":"4","article-title":"Upper limb prosthetic for stroke affected patients","volume":"3","year":"2011","journal-title":"J Eng Sci Tech"},{"key":"ref191","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1186\/1475-925X-13-108","article-title":"Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure","volume":"13","year":"2014","journal-title":"Biomed Eng Online"},{"key":"ref201","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1007\/s11431-013-5449-1","article-title":"Preliminary studies on the basic factors of bionics","volume":"57","year":"2014","journal-title":"Sci China Technol Sci"},{"key":"ref381","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.jelekin.2004.06.007","article-title":"Feasibility of using EMG driven neuromusculoskeletal model for prediction of dynamic movement of the elbow","volume":"15","year":"2005","journal-title":"J Electromyogr Kinesiol"},{"key":"ref371","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1016\/j.sna.2013.09.013","article-title":"Robot fingertip tactile sensing module with a 3D-curved shape using molding technique","volume":"203","year":"2013","journal-title":"Sensors and Actuators A: Physical"},{"key":"ref401","first-page":"4100","year":"2009","journal-title":"Robot kinematics based model to predict compensatory motion of transradial prosthesis while performing bilateral tasks"},{"key":"ref211","first-page":"505","article-title":"Normal functional range of upper limb joints during performance of the feeding activities","volume":"71","year":"1990","journal-title":"Arch Phys Med Rehabil"},{"key":"ref491","first-page":"2","article-title":"A novel electromechanical shoulder articulation for upper-limb prostheses: from the design to the first clinical application","volume":"21","year":"2009","journal-title":"J Prosthet Orthot"},{"key":"ref351","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1177\/0309364611409003","article-title":"Osseointegration amputation prostheses on the upper limbs: methods, prosthetics and rehabilitation","volume":"35","year":"2011","journal-title":"Prosthet Orthot Int"},{"key":"ref101","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1177\/0309364611409003","article-title":"Osseointegration amputation prostheses on the upper limbs: methods, prosthetics and rehabilitation","volume":"35","year":"2011","journal-title":"Prosthet Orthot Int"},{"key":"ref141","volume-title":"Rehabilitation robotics, orthotics, and prosthetics. In Neural repair and rehabilitation","year":"2006"},{"key":"ref241","first-page":"2","article-title":"A novel electromechanical shoulder articulation for upper-limb prostheses: from the design to the first clinical application","volume":"21","year":"2009","journal-title":"J Prosthet Orthot"},{"key":"ref121","doi-asserted-by":"crossref","first-page":"421","DOI":"10.1016\/j.sna.2013.09.013","article-title":"Robot fingertip tactile sensing module with a 3D-curved shape using molding technique","volume":"203","year":"2013","journal-title":"Sensors and Actuators A: Physical"},{"key":"ref281","first-page":"69","article-title":"A simulation study of the consistency of oscillometric blood pressure measurements with and without artefacts","volume":"5","year":"2000","journal-title":"Blood Press Monit"},{"key":"ref31","first-page":"69","article-title":"A simulation study of the consistency of oscillometric blood pressure measurements with and without artefacts","volume":"5","year":"2000","journal-title":"Blood Press Monit"},{"key":"ref71","first-page":"44","article-title":"Body segment parameters","volume":"8","year":"1964","journal-title":"Artificial Limbs"},{"key":"ref291","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1243\/0954411001535570","article-title":"Review of arm motion analyses","volume":"214","year":"2000","journal-title":"Proceeding of Instn Mech Engrs"},{"key":"ref01","year":"2012","journal-title":"Development of an alternative cuff oscillometric socket system. a preliminary study"},{"key":"ref311","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1243\/PIME_PROC_1996_210_420_02","article-title":"Dynamics of the upper limb during performance of the tasks of everyday living- a review of the current knowledge base","volume":"210","year":"1996","journal-title":"Proceeding of Instn Mech Engrs"},{"key":"ref301","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1080\/03093640600994581","article-title":"Upper limb prosthesis use and abandonment: a survey of the last 25 years","volume":"31","year":"2007","journal-title":"Prosthet Orthot Int"},{"key":"ref261","first-page":"863","article-title":"Development of mechanical prosthetic hand system for BCI application","volume":"20","year":"2008","journal-title":"Eur J Sci Res"},{"key":"ref151","first-page":"4100","year":"2009","journal-title":"Robot kinematics based model to predict compensatory motion of transradial prosthesis while performing bilateral tasks"},{"key":"ref321","first-page":"44","article-title":"Body segment parameters","volume":"8","year":"1964","journal-title":"Artificial Limbs"},{"key":"ref451","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1007\/s11431-013-5449-1","article-title":"Preliminary studies on the basic factors of bionics","volume":"57","year":"2014","journal-title":"Sci China Technol Sci"},{"key":"ref91","year":"2008","journal-title":"Conductive inserts to acquire myoelectric signals through silicone liners"},{"key":"ref131","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.jelekin.2004.06.007","article-title":"Feasibility of using EMG driven neuromusculoskeletal model for prediction of dynamic movement of the elbow","volume":"15","year":"2005","journal-title":"J Electromyogr Kinesiol"},{"key":"ref341","year":"2008","journal-title":"Conductive inserts to acquire myoelectric signals through silicone liners"},{"key":"ref471","volume-title":"Functional restoration of adults and children with upper extremity amputation","year":"2004"},{"key":"ref221","volume-title":"Functional restoration of adults and children with upper extremity amputation","year":"2004"},{"key":"ref11","first-page":"863","article-title":"Development of mechanical prosthetic hand system for BCI application","volume":"20","year":"2008","journal-title":"Eur J Sci Res"},{"key":"ref81","first-page":"3748","year":"2007","journal-title":"A gas-actuated anthropomorphic transhumeral prosthesis"},{"key":"ref461","first-page":"505","article-title":"Normal functional range of upper limb joints during performance of the feeding activities","volume":"71","year":"1990","journal-title":"Arch Phys Med Rehabil"},{"key":"ref171","first-page":"1592","year":"1999","journal-title":"EMG prosthetic hand controller discriminating ten motions using real-time learning method"},{"key":"ref421","first-page":"1592","year":"1999","journal-title":"EMG prosthetic hand controller discriminating ten motions using real-time learning method"},{"key":"ref181","first-page":"303","year":"2008","journal-title":"Oscillometric blood pressure monitor modeling"},{"key":"ref251","year":"2012","journal-title":"Development of an alternative cuff oscillometric socket system. a preliminary study"},{"key":"ref41","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1243\/0954411001535570","article-title":"Review of arm motion analyses","volume":"214","year":"2000","journal-title":"Proceeding of Instn Mech Engrs"},{"key":"ref481","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1097\/JPO.0b013e31817ded98","article-title":"Transhumeral and elbow disarticulation anatomically contoured socket considerations","volume":"20","year":"2008","journal-title":"J Prosthet Orthot"},{"key":"ref231","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1097\/JPO.0b013e31817ded98","article-title":"Transhumeral and elbow disarticulation anatomically contoured socket considerations","volume":"20","year":"2008","journal-title":"J Prosthet Orthot"},{"key":"ref391","volume-title":"Rehabilitation robotics, orthotics, and prosthetics. In Neural repair and rehabilitation","year":"2006"},{"key":"ref161","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.sna.2006.07.021","article-title":"Fiber grating sensor for pressure mapping during total knee arthroplasty","volume":"135","year":"2007","journal-title":"Sensor Actuat A: Phys"},{"key":"ref111","first-page":"4","article-title":"Upper limb prosthetic for stroke affected patients","volume":"3","year":"2011","journal-title":"J Eng Sci Tech"},{"key":"ref411","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1016\/j.sna.2006.07.021","article-title":"Fiber grating sensor for pressure mapping during total knee arthroplasty","volume":"135","year":"2007","journal-title":"Sensor Actuat A: Phys"},{"key":"ref431","first-page":"303","year":"2008","journal-title":"Oscillometric blood pressure monitor modeling"},{"key":"ref51","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1080\/03093640600994581","article-title":"Upper limb prosthesis use and abandonment: a survey of the last 25 years","volume":"31","year":"2007","journal-title":"Prosthet Orthot Int"},{"key":"ref61","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1243\/PIME_PROC_1996_210_420_02","article-title":"Dynamics of the upper limb during performance of the tasks of everyday living- a review of the current knowledge base","volume":"210","year":"1996","journal-title":"Proceeding of Instn Mech Engrs"}],"container-title":["Biomedical Engineering \/ Biomedizinische Technik"],"original-title":[],"link":[{"URL":"http:\/\/www.degruyter.com\/view\/j\/bmte.2017.62.issue-1\/bmt-2015-0106\/bmt-2015-0106.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/www.degruyter.com\/view\/j\/bmte.2017.62.issue-1\/bmt-2015-0106\/bmt-2015-0106.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,27]],"date-time":"2021-02-27T20:06:40Z","timestamp":1614456400000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/bmt-2015-0106\/html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1,1]]},"references-count":50,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.1515\/bmt-2015-0106","relation":{},"ISSN":["1862-278X","0013-5585"],"issn-type":[{"value":"1862-278X","type":"electronic"},{"value":"0013-5585","type":"print"}],"subject":[],"published":{"date-parts":[[2017,1,1]]}}}