{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,4]],"date-time":"2025-11-04T11:18:12Z","timestamp":1762255092897,"version":"3.41.2"},"reference-count":21,"publisher":"Walter de Gruyter GmbH","issue":"4","license":[{"start":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T00:00:00Z","timestamp":1744070400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,8,26]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec id=\"j_bmt-2024-0620_abs_001\">\n                  <jats:title>Objectives<\/jats:title>\n                  <jats:p>In this work, it was aimed to employ machine learning (ML) algorithms to accurately forecast the radiation doses for phantoms while accounting for the most popular CT protocols.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec id=\"j_bmt-2024-0620_abs_002\">\n                  <jats:title>Methods<\/jats:title>\n                  <jats:p>A cloud-based software was utilized to calculate the effective doses from different CT protocols. To simulate a range of adult patients with different weights, eight entire body mesh-based computational phantom sets were used. The head, neck, and chest-abdomen-pelvis CT scan characteristics were combined to create a dataset with 33 rows for each phantom and 792 rows total. At the ML stage, linear (LR), random forest (RF) and support vector regression (SVR) were used. Mean absolute error, mean squared error and accuracy were used to evaluate the performances.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec id=\"j_bmt-2024-0620_abs_003\">\n                  <jats:title>Results<\/jats:title>\n                  <jats:p>The female phantoms received higher doses (7.8 %) than males. Furthermore, an average of 11 % more dose was taken to the normal weight phantom than to the overweight, the overweight in comparison to the obese I, and the obese I in comparison to the obese II. Among the ML algorithms, the LR showed 0 error rate and 100 % accuracy in predicting CT doses.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec id=\"j_bmt-2024-0620_abs_004\">\n                  <jats:title>Conclusions<\/jats:title>\n                  <jats:p>The LR was shown to be the best approach out of those used in the ML estimation of CT-induced doses.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1515\/bmt-2024-0620","type":"journal-article","created":{"date-parts":[[2025,4,8]],"date-time":"2025-04-08T03:58:06Z","timestamp":1744084686000},"page":"385-391","source":"Crossref","is-referenced-by-count":1,"title":["Machine learning prediction of effective radiation doses in various computed tomography applications: a virtual human phantom study"],"prefix":"10.1515","volume":"70","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5231-2768","authenticated-orcid":false,"given":"Handan","family":"Tanyildizi-Kokkulunk","sequence":"first","affiliation":[{"name":"Radiotherapy Program , 187458 Vocational School of Health Sciences, Altinbas University , Istanbul , T\u00fcrkiye"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"374","published-online":{"date-parts":[[2025,4,8]]},"reference":[{"key":"2025080106581406494_j_bmt-2024-0620_ref_001","doi-asserted-by":"crossref","unstructured":"Garcia-Sanchez, AJ, Garcia Angosto, E, Llor, JL, Serna, BA, Ramos, D. Machine learning techniques applied to dose prediction in computed tomography tests. Sensors (Basel) 2019;19:5116. https:\/\/doi.org\/10.3390\/s19235116.","DOI":"10.3390\/s19235116"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_002","doi-asserted-by":"crossref","unstructured":"Wagner, LK, Eifel, PJ, Geise, RA. Potential biological effects following high X-ray dose interventional procedures. J Vasc Interv Radiol 1994;5:71\u201384. https:\/\/doi.org\/10.1016\/s1051-0443(94)71456-1.","DOI":"10.1016\/S1051-0443(94)71456-1"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_003","doi-asserted-by":"crossref","unstructured":"Shah, NB, Platt, SL. ALARA: is there a cause for alarm? Reducing radiation risks from computed tomography scanning in children. Curr Opin Pediatr 2008;20:243\u20137. https:\/\/doi.org\/10.1097\/MOP.0b013e3282ffafd2.","DOI":"10.1097\/MOP.0b013e3282ffafd2"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_004","unstructured":"Diagnostic reference levels (DRLs) [Online]. Available from: https:\/\/www.iaea.org\/resources\/rpop\/health-professionals\/radiology\/diagnostic-reference-levels [Accessed: 01 Apr, 2024]."},{"key":"2025080106581406494_j_bmt-2024-0620_ref_005","doi-asserted-by":"crossref","unstructured":"Christner, JA, Braun, NN, Jacobsen, MC, Carter, RE, Kofler, JM, McCollough, CH. Size-specific dose estimates for adult patients at CT of the torso. Radiology 2012;265:841\u20137. https:\/\/doi.org\/10.1148\/radiol.12112365.","DOI":"10.1148\/radiol.12112365"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_006","doi-asserted-by":"crossref","unstructured":"Boos, J, Lanzman, RS, Heusch, P, Aissa, J, Schleich, C, Thomas, C, et al.. Does body mass index outperform body weight as a surrogate parameter in the calculation of size-specific dose estimates in adult body CT? Br J Radiol 2016;89:20150734. https:\/\/doi.org\/10.1259\/bjr.20150734.","DOI":"10.1259\/bjr.20150734"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_007","doi-asserted-by":"crossref","unstructured":"Chawla, NV, Davis, DA. Bringing big data to personalized healthcare: a patient-centered framework, J Gen Intern Med 2013 28:S660\u2013665. https:\/\/doi.org\/10.1007\/s11606-013-2455-8.","DOI":"10.1007\/s11606-013-2455-8"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_008","unstructured":"Zheng, X, Chun, I, Li, Z, Long, Y, Fessler, J. Sparse-view X-ray CT reconstruction using L1 prior with learned transform. In: The 14th International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine 2017. https:\/\/doi.org\/10.48550\/arXiv.1711.00905."},{"key":"2025080106581406494_j_bmt-2024-0620_ref_009","doi-asserted-by":"crossref","unstructured":"Li, Y, Hara, S, Shimura, K. A machine learning approach for locating boundaries of liver tumors in CT images. In: 18th International Conference on Pattern Recognition; 2006:400\u20133 pp. https:\/\/doi.org\/10.1109\/ICPR.2006.93.","DOI":"10.1109\/ICPR.2006.93"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_010","doi-asserted-by":"crossref","unstructured":"Polan, DF, Brady, SL, Kaufman, RA. Tissue segmentation of computed tomography images using a Random Forest algorithm: a feasibility study. Phys Med Biol 2016;61:6553\u201369. https:\/\/doi.org\/10.1088\/0031-9155\/61\/17\/6553.","DOI":"10.1088\/0031-9155\/61\/17\/6553"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_011","doi-asserted-by":"crossref","unstructured":"Babier, A, Boutilier, JJ, McNiven, AL, Chan, TCY. Knowledge-based automated planning for oropharyngeal cancer. Med Phys 2018;45:2875\u201383. https:\/\/doi.org\/10.1002\/mp.12930.","DOI":"10.1002\/mp.12930"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_012","doi-asserted-by":"crossref","unstructured":"Kang, J, Schwartz, R, Flickinger, J, Beriwal, S. Machine learning approaches for predicting radiation therapy outcomes: a clinician\u2019s perspective. Int J Radiat Oncol Biol Phys 2015;93:1127\u201335. https:\/\/doi.org\/10.1016\/j.ijrobp.2015.07.2286.","DOI":"10.1016\/j.ijrobp.2015.07.2286"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_013","doi-asserted-by":"crossref","unstructured":"Ding, A, Gao, Y, Liu, H, Caracappa, PF, Long, DJ, Bolch, WE, et al.. VirtualDose: a software for reporting organ doses from CT for adult and pediatric patients. Phys Med Biol 2015;60:5601\u201325. https:\/\/doi.org\/10.1088\/0031-9155\/60\/14\/5601.","DOI":"10.1088\/0031-9155\/60\/14\/5601"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_014","doi-asserted-by":"crossref","unstructured":"Liang, B, Gao, Y, Chen, Z, Xu, XG. Evaluation of effective dose from CT scans for overweight and obese adult patients using the VirtualDose software. Radiat Protect Dosim 2017;174:216\u201325. https:\/\/doi.org\/10.1093\/rpd\/ncw119.","DOI":"10.1093\/rpd\/ncw119"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_015","doi-asserted-by":"crossref","unstructured":"Karadeniz-Yildirim, A, Ozkorucuklu, S, Tanyildizi-Kokkulunk, H, Demir, M, Yasar, D. Monte Carlo simulation of liver dosimetry with yttrium-90 radionuclide using gate: 3D phantom. Bull Lebedev Phys Inst 2024;51:30\u20137. https:\/\/doi.org\/10.3103\/S1068335623600201.","DOI":"10.3103\/S1068335623600201"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_016","doi-asserted-by":"crossref","unstructured":"Tanyildizi, H, Demir, M, Akku\u015f, B. Detecting the optimal patient-specific radiation dosimetry in Yttrium-90 microsphere therapy. D J Med Sci 2018;4:115\u201322. https:\/\/doi.org\/10.5606\/fng.btd.2018.019.","DOI":"10.5606\/fng.btd.2018.019"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_017","doi-asserted-by":"crossref","unstructured":"K\u00f6kk\u00fcl\u00fcnk, HT, Demir, M, Y\u0131ld\u0131r\u0131m, AK, \u00d6zkorucuklu, S, Akku\u015f, B, Ya\u015far, D. Y-90 dosimetry with Monte Carlo method: GATE validation with STL formatted phantom. Acta Physica Polonica A 2020;138:801\u20138. https:\/\/doi.org\/10.12693\/APhysPolA.138.801.","DOI":"10.12693\/APhysPolA.138.801"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_018","doi-asserted-by":"crossref","unstructured":"Karadeniz-Yildirim, A, Tanyildizi-Kokkulunk, H. Investigation of the tissue equivalence of typical 3D-printing materials for application in internal dosimetry using Monte Carlo simulations. Phys Eng Sci Med 2025;48:665\u201373. https:\/\/doi.org\/10.1007\/s13246-025-01532-2.","DOI":"10.1007\/s13246-025-01532-2"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_019","doi-asserted-by":"crossref","unstructured":"Ding, A, Mille, MM, Liu, T, Caracappa, PF, Xu, XG. Extension of RPI-adult male and female computational phantoms to obese patients and a Monte Carlo study of the effect on CT imaging dose. Phys Med Biol 2012;57:2441\u201359. https:\/\/doi.org\/10.1088\/0031-9155\/57\/9\/2441.","DOI":"10.1088\/0031-9155\/57\/9\/2441"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_020","doi-asserted-by":"crossref","unstructured":"Chai, T, Draxler, RR. Model Development Root mean square error (RMSE) or mean absolute error (MAE)?\u00a0\u2013 Arguments against avoiding RMSE in the literature. Geoscientific 2014;7:1247\u201350. https:\/\/doi.org\/10.5194\/gmd-7-1247-2014.","DOI":"10.5194\/gmd-7-1247-2014"},{"key":"2025080106581406494_j_bmt-2024-0620_ref_021","doi-asserted-by":"crossref","unstructured":"Jung, Y, Hur, J, Han, K, Imai, Y, Hong, YJ, Im, DJ, et al.. Radiation dose reduction using deep learning-based image reconstruction for a low-dose chest computed tomography protocol: a phantom study. Quant Imag Med Surg 2023;13:1937947\u20131947. https:\/\/doi.org\/10.21037\/qims-22-618.","DOI":"10.21037\/qims-22-618"}],"container-title":["Biomedical Engineering \/ Biomedizinische Technik"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.degruyterbrill.com\/document\/doi\/10.1515\/bmt-2024-0620\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.degruyterbrill.com\/document\/doi\/10.1515\/bmt-2024-0620\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,1]],"date-time":"2025-08-01T06:58:38Z","timestamp":1754031518000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.degruyterbrill.com\/document\/doi\/10.1515\/bmt-2024-0620\/html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4,8]]},"references-count":21,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025,4,4]]},"published-print":{"date-parts":[[2025,8,26]]}},"alternative-id":["10.1515\/bmt-2024-0620"],"URL":"https:\/\/doi.org\/10.1515\/bmt-2024-0620","relation":{},"ISSN":["0013-5585","1862-278X"],"issn-type":[{"type":"print","value":"0013-5585"},{"type":"electronic","value":"1862-278X"}],"subject":[],"published":{"date-parts":[[2025,4,8]]}}}