{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,28]],"date-time":"2026-08-28T22:21:32Z","timestamp":1787955692109,"version":"build-2784847793"},"reference-count":74,"publisher":"Walter de Gruyter GmbH","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,6,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n<jats:p>Oral anticoagulant therapies with the anti-vitamin K drugs (AVK), warfarin, acenocoumarol and phenprocoumon, are employed in primary and secondary anti-thrombotic prophylaxis in patients with venous thromboembolism, atrial fibrillation and cardiac mechanical valves. However, a monitoring test such as the International Normalized Ratio (INR) is required. The periodic monitoring of this therapy entails discomfort for the patients. Telemedicine and telecare can provide significant aid in the management of this therapy allowing patients to perform the test at home or anywhere else with a portable device, i.e. point-of-care testing (POCT), and to send the result to a thrombosis (TC) via web. Patients can receive dose adjustment sent back by the TC. The effectiveness of this type of management is equal or superior to the traditional AVK monitoring in terms of hemorrhagic and thrombotic events. Analysis of the costs with a horizon of 10 years reveals that both self-testing and self-management are cost-effective. The aim of this overview is to describe the pros and cons of the use of POCT as an alternative in the monitoring of AVK. In particular, description of the POCT, decentralization, quality of the therapy, safety and costs will be examined.<\/jats:p>","DOI":"10.1515\/cclm-2016-0381","type":"journal-article","created":{"date-parts":[[2016,10,18]],"date-time":"2016-10-18T07:24:04Z","timestamp":1476775444000},"page":"800-805","source":"Crossref","is-referenced-by-count":53,"title":["Point-of-care testing INR: an overview"],"prefix":"10.1515","volume":"55","author":[{"given":"Doris","family":"Barcellona","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lara","family":"Fenu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesco","family":"Marongiu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"374","reference":[{"key":"ref21","first-page":"73","article-title":"The prothrombin in hemophilia and in obstructive jaundice","volume":"109","year":"1935","journal-title":"J Biol Chem"},{"key":"ref641","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1055\/s-0038-1651587","article-title":"A method to determine the optimal intensity of oral anticoagulant therapy","volume":"69","year":"1993","journal-title":"Thromb Haemost"},{"key":"ref71","doi-asserted-by":"crossref","first-page":"2639","DOI":"10.1001\/archinte.163.21.2639","article-title":"Aanticoagulant therapy through patient self-management and management by specialized anticoagulation clinics in the Netherlands: a randomized clinical trial","volume":"163","year":"2003","journal-title":"Arch Int Med"},{"key":"ref141","first-page":"81","article-title":"External quality assessment of point-of-care international normalized ratio (INR) testing in Europe","volume":"50","year":"2011","journal-title":"Clin Chem Lab Med"},{"key":"ref261","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1161\/CIRCOUTCOMES.112.965988","article-title":"Comparative efficacy and safety of new oral anticoagulants in patients with atrial fibrillation","volume":"5","year":"2012","journal-title":"Circ Cardiovasc Qual Outcomes"},{"key":"ref301","first-page":"e131","article-title":"Safety and effectiveness of point-of-care monitoring devices in patients on oral anticoagulant therapy: a meta-analysis","volume":"1","year":"2007","journal-title":"Open Med"},{"key":"ref31","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1055\/s-0038-1657371","article-title":"Calibration of reference thromboplastins and standardization of the prothrombin time ratio","volume":"49","year":"1983","journal-title":"Thromb Haemost"},{"key":"ref471","first-page":"826","article-title":"Assessment of patient capability to self-adjust oral anticoagulant dose: a multicentre study on home use of portable prothrombin time monitor (COAGUCHEK)","volume":"85","year":"2000","journal-title":"Haematologica"},{"key":"ref461","doi-asserted-by":"crossref","first-page":"2639","DOI":"10.1001\/archinte.163.21.2639","article-title":"Aanticoagulant therapy through patient self-management and management by specialized anticoagulation clinics in the Netherlands: a randomized clinical trial","volume":"163","year":"2003","journal-title":"Arch Int Med"},{"key":"ref691","first-page":"e131","article-title":"Safety and effectiveness of point-of-care monitoring devices in patients on oral anticoagulant therapy: a meta-analysis","volume":"1","year":"2007","journal-title":"Open Med"},{"key":"ref221","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1097\/00001721-199710000-00006","article-title":"Assessment of mental ability in elderly anticoagulated patients: its reduction is associated with less satisfactory quality of treatment","volume":"8","year":"1997","journal-title":"Blood Coag Fibrinol"},{"key":"ref401","doi-asserted-by":"crossref","first-page":"2730","DOI":"10.1073\/pnas.71.7.2730","article-title":"Vitamin K dependent modifications of glutamic acid residues in prothrombin","volume":"71","year":"1974","journal-title":"Proc Natl Acad Sci USA"},{"key":"ref681","doi-asserted-by":"crossref","first-page":"1665","DOI":"10.1161\/STROKEAHA.116.013173","article-title":"Female sex, time in therapeutic range, and clinical outcomes in atrial fibrillation patients taking warfarin","volume":"47","year":"2016","journal-title":"Stroke"},{"key":"ref731","doi-asserted-by":"crossref","first-page":"e007758","DOI":"10.1136\/bmjopen-2015-007758","article-title":"Is self-monitoring an effective option for people receiving long-term vitamin K antagonist therapy? a systematic review and economic evaluation","volume":"5","year":"2015","journal-title":"BMJ Open"},{"key":"ref321","doi-asserted-by":"crossref","first-page":"472","DOI":"10.7326\/0003-4819-154-7-201104050-00005","article-title":"Meta-analysis: effect of patient self-testing and self-management of long term anticoagulation on major clinical outcomes","volume":"154","year":"2011","journal-title":"Ann Intern Med"},{"key":"ref761","doi-asserted-by":"crossref","first-page":"e168","DOI":"10.1016\/j.thromres.2012.01.011","article-title":"Antiphospholipid syndrome patients: the performance of Coaguchek XS in the monitoring of Vitamin-K Antagonists","volume":"129","year":"2012","journal-title":"Thromb Res"},{"key":"ref751","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1002\/phar.1344","article-title":"Impact of a new method of warfarin management on patient satisfaction, time and cost","volume":"33","year":"2013","journal-title":"Pharmacotherapy"},{"key":"ref121","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1055\/s-0038-1649700","article-title":"Are capillary whole blood coagulation monitors suitable for the control of oral anticoagulant treatment by the international normalized ratio?","volume":"70","year":"1993","journal-title":"Thromb Haemost"},{"key":"ref91","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1177\/1357633X13501764","article-title":"Telemedicine can improve the quality of oral anticoagulation using portable devices and self-testing at home","volume":"19","year":"2013","journal-title":"J Telemed Telecare"},{"key":"ref11","doi-asserted-by":"crossref","first-page":"2730","DOI":"10.1073\/pnas.71.7.2730","article-title":"Vitamin K dependent modifications of glutamic acid residues in prothrombin","volume":"71","year":"1974","journal-title":"Proc Natl Acad Sci USA"},{"key":"ref61","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1055\/s-0037-1613888","article-title":"A prospective controlled trial comparing weekly self-testing with standard management of patients on stable oral anticoagulation","volume":"83","year":"2000","journal-title":"Thromb Haemost"},{"key":"ref701","first-page":"CD003839","article-title":"Self-monitoring and self-management of oral anticoagulation","volume":"4","year":"2010","journal-title":"Cochrane Database Syst Rev"},{"key":"ref391","doi-asserted-by":"crossref","first-page":"e44S","DOI":"10.1378\/chest.11-2292","article-title":"Oral anticoagulant therapy: antithrombotic therapy and prevention of thrombosis, 9th ed: American College of Chest Physicians evidence-based clinical practice guidelines","volume":"141","year":"2012","journal-title":"Chest"},{"key":"ref231","doi-asserted-by":"crossref","first-page":"e428","DOI":"10.3399\/bjgp15X685633","article-title":"Cohort study of anticoagulation self-monitoring (CASM): a prospective study of its effectiveness in the community","volume":"65","year":"2015","journal-title":"Br J Gen Pract"},{"key":"ref611","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1097\/00001721-199710000-00006","article-title":"Assessment of mental ability in elderly anticoagulated patients: its reduction is associated with less satisfactory quality of treatment","volume":"8","year":"1997","journal-title":"Blood Coag Fibrinol"},{"key":"ref561","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1016\/j.thromres.2008.08.006","article-title":"Point-of-care (POCT) prothrombin time monitors: is a periodical control of their performance useful?","volume":"123","year":"2009","journal-title":"Thromb Res"},{"key":"ref511","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1055\/s-0038-1649700","article-title":"Are capillary whole blood coagulation monitors suitable for the control of oral anticoagulant treatment by the international normalized ratio?","volume":"70","year":"1993","journal-title":"Thromb Haemost"},{"key":"ref541","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1160\/TH04-01-0031","article-title":"Point-of-care international normalized ratios: UK NEQAS experience demonstrates necessity for proficiency testing of three different monitors","volume":"96","year":"2006","journal-title":"Thromb Haemost"},{"key":"ref351","doi-asserted-by":"crossref","first-page":"1608","DOI":"10.1056\/NEJMoa1002617","article-title":"Effect of home testing of international normalized ratio on clinical events","volume":"363","year":"2010","journal-title":"N Engl J Med"},{"key":"ref501","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1111\/j.1538-7836.2011.04568.x","article-title":"Precision and accuracy of point-of-care testing coagulometers used for self-testing and self-management of oral anticoagulant therapy","volume":"10","year":"2012","journal-title":"J Thromb Haemost"},{"key":"ref131","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1080\/00365510600684580","article-title":"External quality assessment of prothrombin time: the split-sample model compared with external quality assessment with commercial control material","volume":"66","year":"2006","journal-title":"Scand J Clin Lab Invest"},{"key":"ref271","article-title":"Stability of high-quality warfarin anticoagulation in a community-based atrial fibrillation cohort: the Anticoagulation and Risk Factors in Atrial Fibrillation (ATRIA) Study","volume":"5","year":"2016","journal-title":"Am Heart Assoc"},{"key":"ref111","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1111\/j.1538-7836.2011.04568.x","article-title":"Precision and accuracy of point-of-care testing coagulometers used for self-testing and self-management of oral anticoagulant therapy","volume":"10","year":"2012","journal-title":"J Thromb Haemost"},{"key":"ref381","doi-asserted-by":"crossref","first-page":"1979","DOI":"10.1111\/j.1538-7836.2012.04866.x","article-title":"Phase III studies on novel oral anticoagulants for stroke prevention in atrial fibrillation: a look beyond the excellent results","volume":"10","year":"2012","journal-title":"J Thromb Haemost"},{"key":"ref581","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1007\/BF02934716","article-title":"Reorganization of an anticoagulation clinic using a telemedicine system: description of the model and preliminary results","volume":"1","year":"2006","journal-title":"Intern Emerg Med"},{"key":"ref341","doi-asserted-by":"crossref","first-page":"e007758","DOI":"10.1136\/bmjopen-2015-007758","article-title":"Is self-monitoring an effective option for people receiving long-term vitamin K antagonist therapy? a systematic review and economic evaluation","volume":"5","year":"2015","journal-title":"BMJ Open"},{"key":"ref591","first-page":"111","article-title":"The evidence to support point-of-care testing","volume":"31","year":"2010","journal-title":"Clin Biochem Rev"},{"key":"ref421","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1055\/s-0038-1657371","article-title":"Calibration of reference thromboplastins and standardization of the prothrombin time ratio","volume":"49","year":"1983","journal-title":"Thromb Haemost"},{"key":"ref151","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1160\/TH04-01-0031","article-title":"Point-of-care international normalized ratios: UK NEQAS experience demonstrates necessity for proficiency testing of three different monitors","volume":"96","year":"2006","journal-title":"Thromb Haemost"},{"key":"ref41","doi-asserted-by":"crossref","first-page":"2509","DOI":"10.1001\/archinte.1989.00390110085018","article-title":"Patient self-management of oral anticoagulant guided by capillary (fingerstick) whole blood prothrombin times","volume":"149","year":"1989","journal-title":"Arch Intern Med"},{"key":"ref331","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/S0140-6736(11)61294-4","article-title":"Self-monitoring of oral anticoagulation: systematic review and meta-analysis of individual patient data","volume":"379","year":"2012","journal-title":"Lancet"},{"key":"ref521","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1080\/00365510600684580","article-title":"External quality assessment of prothrombin time: the split-sample model compared with external quality assessment with commercial control material","volume":"66","year":"2006","journal-title":"Scand J Clin Lab Invest"},{"key":"ref441","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1055\/s-2007-996423","article-title":"State-of-the-art of patient self-management for control of oral anticoagulation","volume":"25","year":"1999","journal-title":"Semin Thromb Hemost"},{"key":"ref51","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1055\/s-2007-996423","article-title":"State-of-the-art of patient self-management for control of oral anticoagulation","volume":"25","year":"1999","journal-title":"Semin Thromb Hemost"},{"key":"ref211","article-title":"Point-of-care testing: future of chronic disease state management?","year":"2015","journal-title":"J Pharm Pract"},{"key":"ref601","article-title":"Point-of-care testing: future of chronic disease state management?","year":"2015","journal-title":"J Pharm Pract"},{"key":"ref171","doi-asserted-by":"crossref","first-page":"775","DOI":"10.1016\/j.thromres.2008.08.006","article-title":"Point-of-care (POCT) prothrombin time monitors: is a periodical control of their performance useful?","volume":"123","year":"2009","journal-title":"Thromb Res"},{"key":"ref531","first-page":"81","article-title":"External quality assessment of point-of-care international normalized ratio (INR) testing in Europe","volume":"50","year":"2011","journal-title":"Clin Chem Lab Med"},{"key":"ref81","first-page":"826","article-title":"Assessment of patient capability to self-adjust oral anticoagulant dose: a multicentre study on home use of portable prothrombin time monitor (COAGUCHEK)","volume":"85","year":"2000","journal-title":"Haematologica"},{"key":"ref191","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1007\/BF02934716","article-title":"Reorganization of an anticoagulation clinic using a telemedicine system: description of the model and preliminary results","volume":"1","year":"2006","journal-title":"Intern Emerg Med"},{"key":"ref281","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1161\/CIRCOUTCOMES.108.796185","article-title":"Anticoagulation control and prediction of adverse events in patients with atrial fibrillation: a systematic review","volume":"1","year":"2008","journal-title":"Circ Cardiovasc Qual Outcomes"},{"key":"ref311","first-page":"CD003839","article-title":"Self-monitoring and self-management of oral anticoagulation","volume":"4","year":"2010","journal-title":"Cochrane Database Syst Rev"},{"key":"ref571","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1007\/BF02934713","article-title":"Monitoring oral anticoagulants: new strategies for an emerging problem","volume":"1","year":"2006","journal-title":"Intern Emerg Med"},{"key":"ref661","article-title":"Stability of high-quality warfarin anticoagulation in a community-based atrial fibrillation cohort: the Anticoagulation and Risk Factors in Atrial Fibrillation (ATRIA) Study","volume":"5","year":"2016","journal-title":"Am Heart Assoc"},{"key":"ref741","doi-asserted-by":"crossref","first-page":"1608","DOI":"10.1056\/NEJMoa1002617","article-title":"Effect of home testing of international normalized ratio on clinical events","volume":"363","year":"2010","journal-title":"N Engl J Med"},{"key":"ref201","first-page":"111","article-title":"The evidence to support point-of-care testing","volume":"31","year":"2010","journal-title":"Clin Biochem Rev"},{"key":"ref431","doi-asserted-by":"crossref","first-page":"2509","DOI":"10.1001\/archinte.1989.00390110085018","article-title":"Patient self-management of oral anticoagulant guided by capillary (fingerstick) whole blood prothrombin times","volume":"149","year":"1989","journal-title":"Arch Intern Med"},{"key":"ref771","doi-asserted-by":"crossref","first-page":"1979","DOI":"10.1111\/j.1538-7836.2012.04866.x","article-title":"Phase III studies on novel oral anticoagulants for stroke prevention in atrial fibrillation: a look beyond the excellent results","volume":"10","year":"2012","journal-title":"J Thromb Haemost"},{"key":"ref161","doi-asserted-by":"crossref","first-page":"936","DOI":"10.1160\/TH09-10-0683","article-title":"External quality assessment (EQA) for CoaguChek monitors","volume":"103","year":"2010","journal-title":"Thromb Haemost"},{"key":"ref291","doi-asserted-by":"crossref","first-page":"1665","DOI":"10.1161\/STROKEAHA.116.013173","article-title":"Female sex, time in therapeutic range, and clinical outcomes in atrial fibrillation patients taking warfarin","volume":"47","year":"2016","journal-title":"Stroke"},{"key":"ref551","doi-asserted-by":"crossref","first-page":"936","DOI":"10.1160\/TH09-10-0683","article-title":"External quality assessment (EQA) for CoaguChek monitors","volume":"103","year":"2010","journal-title":"Thromb Haemost"},{"key":"ref361","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1002\/phar.1344","article-title":"Impact of a new method of warfarin management on patient satisfaction, time and cost","volume":"33","year":"2013","journal-title":"Pharmacotherapy"},{"key":"ref251","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1055\/s-0038-1651587","article-title":"A method to determine the optimal intensity of oral anticoagulant therapy","volume":"69","year":"1993","journal-title":"Thromb Haemost"},{"key":"ref371","doi-asserted-by":"crossref","first-page":"e168","DOI":"10.1016\/j.thromres.2012.01.011","article-title":"Antiphospholipid syndrome patients: the performance of Coaguchek XS in the monitoring of Vitamin-K Antagonists","volume":"129","year":"2012","journal-title":"Thromb Res"},{"key":"ref181","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1007\/BF02934713","article-title":"Monitoring oral anticoagulants: new strategies for an emerging problem","volume":"1","year":"2006","journal-title":"Intern Emerg Med"},{"key":"ref411","first-page":"73","article-title":"The prothrombin in hemophilia and in obstructive jaundice","volume":"109","year":"1935","journal-title":"J Biol Chem"},{"key":"ref01","doi-asserted-by":"crossref","first-page":"e44S","DOI":"10.1378\/chest.11-2292","article-title":"Oral anticoagulant therapy: antithrombotic therapy and prevention of thrombosis, 9th ed: American College of Chest Physicians evidence-based clinical practice guidelines","volume":"141","year":"2012","journal-title":"Chest"},{"key":"ref671","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1161\/CIRCOUTCOMES.108.796185","article-title":"Anticoagulation control and prediction of adverse events in patients with atrial fibrillation: a systematic review","volume":"1","year":"2008","journal-title":"Circ Cardiovasc Qual Outcomes"},{"key":"ref711","doi-asserted-by":"crossref","first-page":"472","DOI":"10.7326\/0003-4819-154-7-201104050-00005","article-title":"Meta-analysis: effect of patient self-testing and self-management of long term anticoagulation on major clinical outcomes","volume":"154","year":"2011","journal-title":"Ann Intern Med"},{"key":"ref621","doi-asserted-by":"crossref","first-page":"e428","DOI":"10.3399\/bjgp15X685633","article-title":"Cohort study of anticoagulation self-monitoring (CASM): a prospective study of its effectiveness in the community","volume":"65","year":"2015","journal-title":"Br J Gen Pract"},{"key":"ref651","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1161\/CIRCOUTCOMES.112.965988","article-title":"Comparative efficacy and safety of new oral anticoagulants in patients with atrial fibrillation","volume":"5","year":"2012","journal-title":"Circ Cardiovasc Qual Outcomes"},{"key":"ref481","doi-asserted-by":"crossref","first-page":"298","DOI":"10.1177\/1357633X13501764","article-title":"Telemedicine can improve the quality of oral anticoagulation using portable devices and self-testing at home","volume":"19","year":"2013","journal-title":"J Telemed Telecare"},{"key":"ref451","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1055\/s-0037-1613888","article-title":"A prospective controlled trial comparing weekly self-testing with standard management of patients on stable oral anticoagulation","volume":"83","year":"2000","journal-title":"Thromb Haemost"},{"key":"ref721","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/S0140-6736(11)61294-4","article-title":"Self-monitoring of oral anticoagulation: systematic review and meta-analysis of individual patient data","volume":"379","year":"2012","journal-title":"Lancet"}],"container-title":["Clinical Chemistry and Laboratory Medicine (CCLM)"],"original-title":[],"link":[{"URL":"http:\/\/www.degruyter.com\/view\/j\/cclm.2017.55.issue-6\/cclm-2016-0381\/cclm-2016-0381.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/cclm-2016-0381\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,21]],"date-time":"2021-04-21T23:54:25Z","timestamp":1619049265000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/cclm-2016-0381\/html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6,1]]},"references-count":74,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.1515\/cclm-2016-0381","relation":{},"ISSN":["1437-4331","1434-6621"],"issn-type":[{"value":"1437-4331","type":"electronic"},{"value":"1434-6621","type":"print"}],"subject":[],"published":{"date-parts":[[2017,6,1]]}}}