{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T07:08:44Z","timestamp":1777532924355,"version":"3.51.4"},"reference-count":58,"publisher":"Walter de Gruyter GmbH","issue":"8","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,7,26]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec id=\"j_cclm-2016-0940_s_999\"><jats:title id=\"d496862e58463\">Background:<\/jats:title><jats:p>Blood collection through intravenous (IV) catheters is a common practice at emergency departments (EDs). This technique is associated with higher in vitro hemolysis rates and may even be amplified by the use of vacuum collection tubes. Our aim was to investigate the association of five different vacuum tubes with hemolysis rates in comparison to an aspiration system under real-life conditions and to propose an equation to estimate the amount of hemolysis, depending on the vacuum collection tube type.<\/jats:p><\/jats:sec><jats:sec id=\"j_cclm-2016-0940_s_998\"><jats:title id=\"d496862e58471\">Methods:<\/jats:title><jats:p>We retrospectively evaluated hemolysis data of plasma samples from our ED, where blood is drawn through IV catheters. Over the past 5 years, we compared 19,001 hemolysis index values amongst each other and against the respective vacuum pressure (P<jats:sub>v<\/jats:sub>) of the collection tubes, which were used within the six observational periods.<\/jats:p><\/jats:sec><jats:sec id=\"j_cclm-2016-0940_s_997\"><jats:title id=\"d496862e58482\">Results:<\/jats:title><jats:p>The highest hemolysis rates were associated with full-draw evacuated tubes. Significantly reduced hemolysis was observed for two kinds of partial-draw tubes. The hemolysis rate of one partial-draw blood collection tube was comparable to those of the aspiration system. Regression analysis of P<jats:sub>v<\/jats:sub>and mean free hemoglobin (fHb) values yielded the formula fHb (g\/L)=0.0082*P<jats:sub>v<\/jats:sub><jats:sup>2<\/jats:sup>\u20130.1143*P<jats:sub>v<\/jats:sub>+ 0.5314 with an R<jats:sup>2<\/jats:sup>of 0.99.<\/jats:p><\/jats:sec><jats:sec id=\"j_cclm-2016-0940_s_996\"><jats:title id=\"d496862e58504\">Conclusions:<\/jats:title><jats:p>If IV catheters are used for blood collection, hemolysis rates directly correlate with the vacuum within the tubes and can be estimated by the proposed formula. By the use of partial-draw vacuum blood collection tubes, hemolysis rates in IV catheter collections can be reduced to levels comparable with collections performed by aspiration systems.<\/jats:p><\/jats:sec>","DOI":"10.1515\/cclm-2016-0940","type":"journal-article","created":{"date-parts":[[2017,1,20]],"date-time":"2017-01-20T10:01:50Z","timestamp":1484906510000},"page":"1129-1134","source":"Crossref","is-referenced-by-count":21,"title":["The relationship between vacuum and hemolysis during catheter blood collection: a retrospective analysis of six large cohorts"],"prefix":"10.1515","volume":"55","author":[{"given":"Cornelia","family":"Mrazek","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ana-Maria","family":"Simundic","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Helmut","family":"Wiedemann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Florian","family":"Krahmer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas Klaus","family":"Felder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ulrike","family":"Kipman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Uta","family":"Hoppe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elisabeth","family":"Haschke-Becher","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Janne","family":"Cadamuro","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"374","reference":[{"key":"ref111","doi-asserted-by":"crossref","first-page":"1987","DOI":"10.1515\/cclm-2016-0175","article-title":"Hemolysis rates in blood samples: differences between blood collected by clinicians and nurses and the effect of phlebotomy training","volume":"54","year":"2016","journal-title":"Clin Chem Lab Med"},{"key":"ref31","doi-asserted-by":"crossref","first-page":"143","DOI":"10.3109\/10408363.2011.600228","article-title":"Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories","volume":"48","year":"2011","journal-title":"Crit Rev Cl Lab Sci"},{"key":"ref71","doi-asserted-by":"crossref","first-page":"e24","DOI":"10.1111\/ijlh.12135","article-title":"Prevalence and cost of hemolyzed samples in a large urban emergency department","volume":"36","year":"2014","journal-title":"Int J Lab Hematol"},{"key":"ref81","first-page":"e285","article-title":"The economic burden of hemolysis","volume":"53","year":"2015","journal-title":"Clin Chem Lab Med"},{"key":"ref231","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.clinbiochem.2013.12.004","article-title":"Low volume tubes are not effective to reduce the rate of hemolyzed specimens from the emergency department","volume":"47","year":"2014","journal-title":"Clin Biochem"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"248","DOI":"10.11613\/BM.2014.027","article-title":"Pre-analytical errors management in the clinical laboratory: a five-year study","volume":"24","year":"2014","journal-title":"Biochem Med (Zagreb)"},{"key":"ref211","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.jen.2004.10.004","article-title":"Blood samples drawn from IV catheters have less hemolysis when 5-mL (vs 10-mL) collection tubes are used","volume":"30","year":"2004","journal-title":"J Emerg Nurs"},{"key":"ref51","doi-asserted-by":"crossref","first-page":"1151","DOI":"10.1111\/acem.12245","article-title":"Use of butterfly needles to draw blood is independently associated with marked reduction in hemolysis compared to intravenous catheter","volume":"20","year":"2013","journal-title":"Acad Emerg Med"},{"key":"ref121","first-page":"69","article-title":"The use of s-monovette is effective to reduce the burden of hemolysis in a large urban emergency department","volume":"25","year":"2015","journal-title":"Biochem Med (Zagreb)"},{"key":"ref221","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.1016\/j.clinbiochem.2013.04.005","article-title":"Low vacuum and discard tubes reduce hemolysis in samples drawn from intravenous catheters","volume":"46","year":"2013","journal-title":"Clin Biochem"},{"key":"ref441","first-page":"153","article-title":"[Factors related to haemolysis in the extraction of blood samples]","volume":"31","year":"2008","journal-title":"An Sist Sanit Navar"},{"key":"ref571","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.cca.2009.03.025","article-title":"The ifcc working group on laboratory errors and patient safety","volume":"404","year":"2009","journal-title":"Clin Chim Acta"},{"key":"ref141","first-page":"216","volume":"6","year":"2010","journal-title":"Hemolysis by peripheral intravenous catheters: materials comparison. RIMeL\/IJLaM"},{"key":"ref531","doi-asserted-by":"crossref","first-page":"1142","DOI":"10.1016\/j.clinbiochem.2013.04.005","article-title":"Low vacuum and discard tubes reduce hemolysis in samples drawn from intravenous catheters","volume":"46","year":"2013","journal-title":"Clin Biochem"},{"key":"ref351","first-page":"311","article-title":"Influence of hemolysis on routine clinical chemistry testing","volume":"44","year":"2006","journal-title":"Clin Chem Lab Med"},{"key":"ref501","first-page":"193","article-title":"Critical review and meta-analysis of spurious hemolysis in blood samples collected from intravenous catheters","volume":"23","year":"2013","journal-title":"Biochem Med (Zagreb)"},{"key":"ref401","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1258\/acb.2009.008228","article-title":"A prospective study of causes of haemolysis during venepuncture: tourniquet time should be kept to a minimum","volume":"46","year":"2009","journal-title":"Ann Clin Biochem"},{"key":"ref421","doi-asserted-by":"crossref","first-page":"1987","DOI":"10.1515\/cclm-2016-0175","article-title":"Hemolysis rates in blood samples: differences between blood collected by clinicians and nurses and the effect of phlebotomy training","volume":"54","year":"2016","journal-title":"Clin Chem Lab Med"},{"key":"ref521","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.jen.2004.10.004","article-title":"Blood samples drawn from IV catheters have less hemolysis when 5-mL (vs 10-mL) collection tubes are used","volume":"30","year":"2004","journal-title":"J Emerg Nurs"},{"key":"ref191","first-page":"193","article-title":"Critical review and meta-analysis of spurious hemolysis in blood samples collected from intravenous catheters","volume":"23","year":"2013","journal-title":"Biochem Med (Zagreb)"},{"key":"ref601","doi-asserted-by":"crossref","first-page":"1344","DOI":"10.1016\/j.clinbiochem.2014.06.016","article-title":"Low vacuum versus low volume tubes and the reduction of hemolyzed specimens from the emergency department","volume":"47","year":"2014","journal-title":"Clin Biochem"},{"key":"ref251","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.cca.2013.10.012","article-title":"Harmonization of automated hemolysis index assessment and use: Is it possible?","volume":"432","year":"2014","journal-title":"Clin Chim Acta"},{"key":"ref471","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1093\/clinchem\/46.2.306","article-title":"Hemolyzed specimens: A reason for rejection or a clinical challenge?","volume":"46","year":"2000","journal-title":"Clin Chem"},{"key":"ref201","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.1016\/j.clinbiochem.2012.08.002","article-title":"Effectiveness of practices to reduce blood sample hemolysis in EDS: a laboratory medicine best practices systematic review and meta-analysis","volume":"45","year":"2012","journal-title":"Clin Biochem"},{"key":"ref491","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1016\/j.clinbiochem.2013.01.021","article-title":"Prevention of hemolysis in blood samples collected from intravenous catheters","volume":"46","year":"2013","journal-title":"Clin Biochem"},{"key":"ref551","doi-asserted-by":"crossref","first-page":"1717","DOI":"10.1373\/clinchem.2007.091421","article-title":"Measurements of free hemoglobin and hemolysis index: edta- or lithium-heparinate plasma?","volume":"53","year":"2007","journal-title":"Clin Chem"},{"key":"ref261","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.cca.2009.03.025","article-title":"The ifcc working group on laboratory errors and patient safety","volume":"404","year":"2009","journal-title":"Clin Chim Acta"},{"key":"ref561","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1016\/j.cca.2013.10.012","article-title":"Harmonization of automated hemolysis index assessment and use: Is it possible?","volume":"432","year":"2014","journal-title":"Clin Chim Acta"},{"key":"ref41","first-page":"311","article-title":"Influence of hemolysis on routine clinical chemistry testing","volume":"44","year":"2006","journal-title":"Clin Chem Lab Med"},{"key":"ref341","doi-asserted-by":"crossref","first-page":"143","DOI":"10.3109\/10408363.2011.600228","article-title":"Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories","volume":"48","year":"2011","journal-title":"Crit Rev Cl Lab Sci"},{"key":"ref541","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1016\/j.clinbiochem.2013.12.004","article-title":"Low volume tubes are not effective to reduce the rate of hemolyzed specimens from the emergency department","volume":"47","year":"2014","journal-title":"Clin Biochem"},{"key":"ref321","first-page":"105","article-title":"Harmonization of pre\u2013analytical quality indicators","volume":"24","year":"2014","journal-title":"Biochem Med (Zagreb)"},{"key":"ref411","first-page":"471","article-title":"Speed of sample transportation by a pneumatic tube system can influence the degree of hemolysis","volume":"50","year":"2012","journal-title":"Clin Chem Lab Med"},{"key":"ref331","doi-asserted-by":"crossref","first-page":"248","DOI":"10.11613\/BM.2014.027","article-title":"Pre-analytical errors management in the clinical laboratory: a five-year study","volume":"24","year":"2014","journal-title":"Biochem Med (Zagreb)"},{"key":"ref481","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1007\/s11739-011-0568-9","article-title":"Use of separate venipunctures for IV access and laboratory studies decreases hemolysis rates","volume":"6","year":"2011","journal-title":"Intern Emerg Med"},{"key":"ref301","doi-asserted-by":"crossref","first-page":"1344","DOI":"10.1016\/j.clinbiochem.2014.06.016","article-title":"Low vacuum versus low volume tubes and the reduction of hemolyzed specimens from the emergency department","volume":"47","year":"2014","journal-title":"Clin Biochem"},{"key":"ref61","first-page":"49","article-title":"In-vitro hemolysis and its financial impact using different blood collection systems","volume":"40","year":"2016","journal-title":"J Lab Med"},{"key":"ref371","first-page":"49","article-title":"In-vitro hemolysis and its financial impact using different blood collection systems","volume":"40","year":"2016","journal-title":"J Lab Med"},{"key":"ref611","doi-asserted-by":"crossref","first-page":"1344","DOI":"10.1016\/j.clinbiochem.2014.06.016","article-title":"Low vacuum versus low volume tubes and the reduction of hemolyzed specimens from the emergency department","volume":"47","year":"2014","journal-title":"Clin Biochem"},{"key":"ref591","year":"1861","journal-title":"A textbook on chemistry"},{"key":"ref361","doi-asserted-by":"crossref","first-page":"1151","DOI":"10.1111\/acem.12245","article-title":"Use of butterfly needles to draw blood is independently associated with marked reduction in hemolysis compared to intravenous catheter","volume":"20","year":"2013","journal-title":"Acad Emerg Med"},{"key":"ref01","first-page":"764","article-title":"Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories","volume":"46","year":"2008","journal-title":"Clin Chem Lab Med"},{"key":"ref181","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1016\/j.clinbiochem.2013.01.021","article-title":"Prevention of hemolysis in blood samples collected from intravenous catheters","volume":"46","year":"2013","journal-title":"Clin Biochem"},{"key":"ref101","first-page":"471","article-title":"Speed of sample transportation by a pneumatic tube system can influence the degree of hemolysis","volume":"50","year":"2012","journal-title":"Clin Chem Lab Med"},{"key":"ref131","first-page":"153","article-title":"[Factors related to haemolysis in the extraction of blood samples]","volume":"31","year":"2008","journal-title":"An Sist Sanit Navar"},{"key":"ref381","doi-asserted-by":"crossref","first-page":"e24","DOI":"10.1111\/ijlh.12135","article-title":"Prevalence and cost of hemolyzed samples in a large urban emergency department","volume":"36","year":"2014","journal-title":"Int J Lab Hematol"},{"key":"ref311","first-page":"764","article-title":"Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories","volume":"46","year":"2008","journal-title":"Clin Chem Lab Med"},{"key":"ref391","first-page":"e285","article-title":"The economic burden of hemolysis","volume":"53","year":"2015","journal-title":"Clin Chem Lab Med"},{"key":"ref241","doi-asserted-by":"crossref","first-page":"1717","DOI":"10.1373\/clinchem.2007.091421","article-title":"Measurements of free hemoglobin and hemolysis index: edta- or lithium-heparinate plasma?","volume":"53","year":"2007","journal-title":"Clin Chem"},{"key":"ref511","doi-asserted-by":"crossref","first-page":"1012","DOI":"10.1016\/j.clinbiochem.2012.08.002","article-title":"Effectiveness of practices to reduce blood sample hemolysis in EDS: a laboratory medicine best practices systematic review and meta-analysis","volume":"45","year":"2012","journal-title":"Clin Biochem"},{"key":"ref91","doi-asserted-by":"crossref","first-page":"244","DOI":"10.1258\/acb.2009.008228","article-title":"A prospective study of causes of haemolysis during venepuncture: tourniquet time should be kept to a minimum","volume":"46","year":"2009","journal-title":"Ann Clin Biochem"},{"key":"ref171","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1007\/s11739-011-0568-9","article-title":"Use of separate venipunctures for IV access and laboratory studies decreases hemolysis rates","volume":"6","year":"2011","journal-title":"Intern Emerg Med"},{"key":"ref291","doi-asserted-by":"crossref","first-page":"1344","DOI":"10.1016\/j.clinbiochem.2014.06.016","article-title":"Low vacuum versus low volume tubes and the reduction of hemolyzed specimens from the emergency department","volume":"47","year":"2014","journal-title":"Clin Biochem"},{"key":"ref431","first-page":"69","article-title":"The use of s-monovette is effective to reduce the burden of hemolysis in a large urban emergency department","volume":"25","year":"2015","journal-title":"Biochem Med (Zagreb)"},{"key":"ref161","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1093\/clinchem\/46.2.306","article-title":"Hemolyzed specimens: A reason for rejection or a clinical challenge?","volume":"46","year":"2000","journal-title":"Clin Chem"},{"key":"ref451","first-page":"216","volume":"6","year":"2010","journal-title":"Hemolysis by peripheral intravenous catheters: materials comparison. RIMeL\/IJLaM"},{"key":"ref281","year":"1861","journal-title":"A textbook on chemistry"},{"key":"ref11","first-page":"105","article-title":"Harmonization of pre\u2013analytical quality indicators","volume":"24","year":"2014","journal-title":"Biochem Med (Zagreb)"}],"container-title":["Clinical Chemistry and Laboratory Medicine (CCLM)"],"original-title":[],"link":[{"URL":"http:\/\/www.degruyter.com\/view\/j\/cclm.2017.55.issue-8\/cclm-2016-0940\/cclm-2016-0940.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/cclm-2016-0940\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,21]],"date-time":"2023-08-21T21:28:13Z","timestamp":1692653293000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/cclm-2016-0940\/html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,7,26]]},"references-count":58,"journal-issue":{"issue":"8"},"URL":"https:\/\/doi.org\/10.1515\/cclm-2016-0940","relation":{},"ISSN":["1437-4331","1434-6621"],"issn-type":[{"value":"1437-4331","type":"electronic"},{"value":"1434-6621","type":"print"}],"subject":[],"published":{"date-parts":[[2017,7,26]]}}}