{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,22]],"date-time":"2026-10-22T09:12:02Z","timestamp":1792660322727,"version":"4.5.0"},"reference-count":13,"publisher":"Walter de Gruyter GmbH","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,2,23]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:sec id=\"j_cclm-2017-0402_s_999_w2aab3b7c44b1b6b1aab1c15b1Aa\">\n                  <jats:title>Background:<\/jats:title>\n                  <jats:p>The need to satisfy high-throughput demands for laboratory tests continues to be a challenge. Therefore, we aimed to automate postanalytical phase in hematology and coagulation laboratory by autovalidation of complete blood count (CBC) and routine coagulation test results (prothrombin time [PT], international normalized ratio [PT-INR], activated partial thromboplastin time [APTT], fibrinogen, antithrombin activity [AT] and thrombin time [TT]). Work efficacy and turnaround time (TAT) before and after implementation of automated solutions will be compared.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec id=\"j_cclm-2017-0402_s_998_w2aab3b7c44b1b6b1aab1c15b2Aa\">\n                  <jats:title>Methods:<\/jats:title>\n                  <jats:p>Ordering panels tailored to specific patient populations were implemented. Rerun and reflex testing rules were set in the respective analyzers\u2019 software (Coulter DxH Connectivity 1601, Beckman Coulter, FL, USA; AutoAssistant, Siemens Healthcare Diagnostics, Germany), and sample status information was transferred into the laboratory information system. To evaluate if the automation improved TAT and efficacy, data from manually verified results in September and October of 2015 were compared with the corresponding period in 2016 when autovalidation was implemented.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec id=\"j_cclm-2017-0402_s_997_w2aab3b7c44b1b6b1aab1c15b3Aa\">\n                  <jats:title>Results:<\/jats:title>\n                  <jats:p>Autovalidation rates of 63% for CBC and 65% for routine coagulation test results were achieved. At the TAT of 120 min, the percentage of reported results increased substantially for all analyzed tests, being above 90% for CBC, PT, PT-INR and fibrinogen and 89% for APTT. This output was achieved with three laboratory technicians less compared with the period when the postanalytical phase was not automated.<\/jats:p>\n               <\/jats:sec>\n               <jats:sec id=\"j_cclm-2017-0402_s_996_w2aab3b7c44b1b6b1aab1c15b4Aa\">\n                  <jats:title>Conclusions:<\/jats:title>\n                  <jats:p>Automation allowed optimized laboratory workflow for specific patient populations, thereby ensuring standardized results reporting. Autovalidation of test results proved to be an efficient tool for improvement of laboratory work efficacy and TAT.<\/jats:p>\n               <\/jats:sec>","DOI":"10.1515\/cclm-2017-0402","type":"journal-article","created":{"date-parts":[[2017,9,23]],"date-time":"2017-09-23T10:00:49Z","timestamp":1506160849000},"page":"454-462","source":"Crossref","is-referenced-by-count":21,"title":["Autovalidation and automation of the postanalytical phase of routine hematology and coagulation analyses in a university hospital laboratory"],"prefix":"10.1515","volume":"56","author":[{"given":"Ana","family":"Mlinaric","sequence":"first","affiliation":[{"name":"Department of Laboratory Diagnostics , University Hospital Centre Zagreb , Kispaticeva 12 , Zagreb 10000 , Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marija","family":"Milos","sequence":"additional","affiliation":[{"name":"Department of Laboratory Diagnostics , University Hospital Centre Zagreb , Zagreb , Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D\u00e9sir\u00e9e","family":"Coen Herak","sequence":"additional","affiliation":[{"name":"Department of Laboratory Diagnostics , University Hospital Centre Zagreb , Zagreb , Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mirjana","family":"Fucek","sequence":"additional","affiliation":[{"name":"Department of Laboratory Diagnostics , University Hospital Centre Zagreb , Zagreb , Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vladimira","family":"Rimac","sequence":"additional","affiliation":[{"name":"Department of Transfusion Medicine and Transplantation Biology , University Hospital Centre Zagreb , Zagreb , Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Renata","family":"Zadro","sequence":"additional","affiliation":[{"name":"Department of Laboratory Diagnostics , University Hospital Centre Zagreb , Zagreb , Croatia"},{"name":"Department of Medical Biochemistry and Hematology, Faculty of Pharmacy and Biochemistry , University of Zagreb , Zagreb , Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dunja","family":"Rogic","sequence":"additional","affiliation":[{"name":"Department of Laboratory Diagnostics , University Hospital Centre Zagreb , Zagreb , Croatia"},{"name":"Department of Medical Biochemistry and Hematology, Faculty of Pharmacy and Biochemistry , University of Zagreb , Zagreb , Croatia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"374","published-online":{"date-parts":[[2017,9,23]]},"reference":[{"key":"2021021223263826781_j_cclm-2017-0402_ref_001_w2aab3b7c44b1b6b1ab2b2b1Aa","doi-asserted-by":"crossref","unstructured":"Shih MC, Chang HM, Tien N, Hsiao CT, Peng CT. Building and validating an autovalidation system in the clinical chemistry laboratory. Lab Med 2011;42:668\u201373.","DOI":"10.1309\/LM5AM4IIXC4OIETD"},{"key":"2021021223263826781_j_cclm-2017-0402_ref_002_w2aab3b7c44b1b6b1ab2b2b2Aa","doi-asserted-by":"crossref","unstructured":"Oosterhuis WP, Ulenkate HJ, Goldschmidt HM. Evaluation of lab respond, a new automated validation system for clinical laboratory test results. Clin Chem 2000;46:1811\u20137.","DOI":"10.1093\/clinchem\/46.11.1811"},{"key":"2021021223263826781_j_cclm-2017-0402_ref_003_w2aab3b7c44b1b6b1ab2b2b3Aa","unstructured":"Duca DJ. Autovalidation in a laboratory information system. Lab Med 2012;1:21\u20135."},{"key":"2021021223263826781_j_cclm-2017-0402_ref_004_w2aab3b7c44b1b6b1ab2b2b4Aa","doi-asserted-by":"crossref","unstructured":"Guidi GC, Poli G, Bassi A, Giobelli L, Benetollo PP, Lippi G. Development and implementation of an automatic system for verification, validation and delivery of laboratory test results. Clin Chem Lab Med 2009;47:1355\u201360.","DOI":"10.1515\/CCLM.2009.316"},{"key":"2021021223263826781_j_cclm-2017-0402_ref_005_w2aab3b7c44b1b6b1ab2b2b5Aa","doi-asserted-by":"crossref","unstructured":"Martinez-Nieto O, Lozano-Gait\u00e1n A, Beltr\u00e1n-Diaz P, Mojica-Figueroa IL, Morales-Reyes OL, Isaza-Ruget MA. Autovalidation of the automated blood cell counter (CBC) in a reference laboratory in Bogota, Colombia. J Bras Patol Med Lab 2015;51:369\u201375.","DOI":"10.5935\/1676-2444.20150058"},{"key":"2021021223263826781_j_cclm-2017-0402_ref_006_w2aab3b7c44b1b6b1ab2b2b6Aa","unstructured":"Croatian Chamber of Medical Biochemists. Recommendation for critical results reporting. Available at: http:\/\/www.hkmb.hr\/dokumenti\/povjerenstva\/HKMB%20PPSP%208.pdf. Accessed: 30 May 2017."},{"key":"2021021223263826781_j_cclm-2017-0402_ref_007_w2aab3b7c44b1b6b1ab2b2b7Aa","doi-asserted-by":"crossref","unstructured":"Barnes PW, McFadden SL, Machin SJ, Simson E. The international consensus group for hematology review. Suggested criteria for action following automated CBC and WBC differential analysis. Lab Hematol 2005;11:83\u201390.","DOI":"10.1532\/LH96.05019"},{"key":"2021021223263826781_j_cclm-2017-0402_ref_008_w2aab3b7c44b1b6b1ab2b2b8Aa","unstructured":"Fraser CG. Reference change values. Clin Chem Lab Med 2011;50:807\u201312."},{"key":"2021021223263826781_j_cclm-2017-0402_ref_009_w2aab3b7c44b1b6b1ab2b2b9Aa","doi-asserted-by":"crossref","unstructured":"Ricos C, Alvarez V, Cava F, Garcia-Lario JV, Hernandez A, Jimenez CV, et al. Current databases on biologic variation: pros, cons and progress. Scand J Clin Lab Invest 1999;59: 491\u2013500.","DOI":"10.1080\/00365519950185229"},{"key":"2021021223263826781_j_cclm-2017-0402_ref_010_w2aab3b7c44b1b6b1ab2b2c10Aa","doi-asserted-by":"crossref","unstructured":"Buttarello M. Quality specification in hematology: the automated blood cell count. Clin Chim Acta 2004;346: 45\u201354.","DOI":"10.1016\/j.cccn.2004.02.038"},{"key":"2021021223263826781_j_cclm-2017-0402_ref_011_w2aab3b7c44b1b6b1ab2b2c11Aa","doi-asserted-by":"crossref","unstructured":"Froom P, Barak M. Auto-validation of complete blood counts in an outpatient\u2019s regional laboratory. Clin Chem Lab Med 2015;53:275\u20139.","DOI":"10.1515\/cclm-2014-0572"},{"key":"2021021223263826781_j_cclm-2017-0402_ref_012_w2aab3b7c44b1b6b1ab2b2c12Aa","doi-asserted-by":"crossref","unstructured":"Froom P, Saffuri-Elias E, Barak M. Autovalidation rates in an outpatient coagulation laboratory. Int J Lab Hem 2015;37:380\u20135.","DOI":"10.1111\/ijlh.12386"},{"key":"2021021223263826781_j_cclm-2017-0402_ref_013_w2aab3b7c44b1b6b1ab2b2c13Aa","doi-asserted-by":"crossref","unstructured":"Onel\u00f6v L, Gustafsson E, Gr\u00f6nlund E, Andersson H, Hellberg G, J\u00e4rnberg I, et al. Autoverification of routine coagulation assays in a multi-center laboratory. Scand J Clin Lab 2016;76:500\u20132.","DOI":"10.1080\/00365513.2016.1200135"}],"container-title":["Clinical Chemistry and Laboratory Medicine (CCLM)"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.degruyter.com\/view\/j\/cclm.2018.56.issue-3\/cclm-2017-0402\/cclm-2017-0402.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/cclm-2017-0402\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/cclm-2017-0402\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,21]],"date-time":"2021-04-21T23:58:22Z","timestamp":1619049502000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/cclm-2017-0402\/html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,9,23]]},"references-count":13,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2017,9,23]]},"published-print":{"date-parts":[[2018,2,23]]}},"alternative-id":["10.1515\/cclm-2017-0402"],"URL":"https:\/\/doi.org\/10.1515\/cclm-2017-0402","relation":{},"ISSN":["1437-4331","1434-6621"],"issn-type":[{"value":"1437-4331","type":"electronic"},{"value":"1434-6621","type":"print"}],"subject":[],"published":{"date-parts":[[2017,9,23]]}}}