{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T02:36:08Z","timestamp":1790649368918,"version":"4.1.0"},"reference-count":37,"publisher":"Walter de Gruyter GmbH","issue":"12","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,11,26]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Stability of a measurand in a specimen is a function of the property variation over time in specific storage conditions, which can be expressed as a stability equation, and is usually simplified to stability limits (SLs). Stability studies show differences or even inconsistent results due to the lack of standardized experimental designs and heterogeneity of the chosen specifications. Although guidelines for the validation of sample collection tubes have been published recently, the measurand stability evaluation is not addressed. This document provides an easy guideline for the development of a stability test protocol based on a two-step process. A preliminary test is proposed to evaluate the stability under laboratory habitual conditions. The loss of stability is assessed by comparing measurement values of two samples obtained from the same patient and analyzed at different time points. One of them is analyzed under optimal conditions (basal sample). The other is stored under specific stability conditions for a time set by the laboratory (test sample). Differences are expressed using percentage deviation (PD%) to facilitate comparison with specifications. When the preliminary test demonstrates instability, a comprehensive test is proposed in order to define the stability equation and to specify SLs. Several samples are collected from a set of patients. The basal sample is analyzed under optimal conditions, whereas analysis of test samples is delayed at time intervals. For each patient PD% is calculated as the difference between measurements for every test sample and its basal one and represented in a coordinate graph versus time.<\/jats:p>","DOI":"10.1515\/cclm-2019-0586","type":"journal-article","created":{"date-parts":[[2019,7,26]],"date-time":"2019-07-26T09:02:16Z","timestamp":1564131736000},"page":"1829-1836","source":"Crossref","is-referenced-by-count":51,"title":["A protocol for testing the stability of biochemical analytes. Technical document"],"prefix":"10.1515","volume":"57","author":[{"given":"Rub\u00e9n","family":"G\u00f3mez-Rioja","sequence":"first","affiliation":[{"name":"Laboratory Medicine Department , La Paz-Cantoblanco-Carlos III University Hospital , Madrid , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marta","family":"Segovia Amaro","sequence":"additional","affiliation":[{"name":"Laboratory Medicine Department , La Paz-Cantoblanco-Carlos III University Hospital , Madrid , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jorge","family":"Diaz-Garz\u00f3n","sequence":"additional","affiliation":[{"name":"Laboratory Medicine Department , La Paz-Cantoblanco-Carlos III University Hospital , Madrid , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Josep Miquel","family":"Bau\u00e7\u00e0","sequence":"additional","affiliation":[{"name":"Laboratory Medicine Department , Hospital Universitari Son Espases , Palma , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D\u00e9bora","family":"Mart\u00ednez Espartosa","sequence":"additional","affiliation":[{"name":"Laboratory Department , Cl\u00ednica Universitaria de Navarra , Madrid , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pilar","family":"Fern\u00e1ndez-Calle","sequence":"additional","affiliation":[{"name":"Laboratory Medicine Department , La Paz-Cantoblanco-Carlos III University Hospital , Madrid , Spain"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"374","published-online":{"date-parts":[[2019,7,26]]},"reference":[{"key":"2023033110125178874_j_cclm-2019-0586_ref_001_w2aab3b7d172b1b6b1ab2b1b1Aa","unstructured":"Guder WG, Fiedler M, daFonseca Wollheim F, Schmitt Y, T\u00f6pfer G, Wisser H, et al. The quality of diagnostic samples. 4th completely revised ed. 2005. Oxford: BD Diagnostics."},{"key":"2023033110125178874_j_cclm-2019-0586_ref_002_w2aab3b7d172b1b6b1ab2b1b2Aa","unstructured":"Effects of Disease on Clinical Laboratory Tests, 4th Edition, Vol. 1 and 2. D.S. Young and R.B. Friedman, eds. Washington, DC: AACC Press, 2001."},{"key":"2023033110125178874_j_cclm-2019-0586_ref_003_w2aab3b7d172b1b6b1ab2b1b3Aa","doi-asserted-by":"crossref","unstructured":"G\u00f3mez-Rioja R, Mart\u00ednez Espartosa D, Segovia M, Ibarz M, LlopisMA, Bau\u00e7a JM, et al. Laboratory sample stability. Is it possible to define a consensus stability function? An example of five blood magnitudes. Clin Chem Lab Med 2018;56:1806\u201318.","DOI":"10.1515\/cclm-2017-1189"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_004_w2aab3b7d172b1b6b1ab2b1b4Aa","unstructured":"CLSI. Procedures for the Handling and Processing of Blood Specimens for Common Laboratory Tests; Approved Guideline 4th Edition. CLSI document GP44-A4. Wayne, PA: Clinical and Laboratory Standards Institute; 2010."},{"key":"2023033110125178874_j_cclm-2019-0586_ref_005_w2aab3b7d172b1b6b1ab2b1b5Aa","unstructured":"CLSI. Procedures for de Collection of Arterial Blood Specimens; Approved Standard-4th Edition. CLSI document GP43-A4. Wayne, PA: Clinical and Laboratory Standards Institute; 2004."},{"key":"2023033110125178874_j_cclm-2019-0586_ref_006_w2aab3b7d172b1b6b1ab2b1b6Aa","unstructured":"CLSI. Urinalysis; Approved Guideline-Third Edition CLSI document GP16-A3. Wayne, PA: Clinical and Laboratory Standards Institute; Clinical and Laboratory Standards Institute; 2009."},{"key":"2023033110125178874_j_cclm-2019-0586_ref_007_w2aab3b7d172b1b6b1ab2b1b7Aa","unstructured":"UNE-EN ISO 15189:2012. Medical laboratories \u2013 articular requirements for quality and competence. http:\/\/www.iso.org\/iso\/iso_catalogue\/catalogue_tc\/catalogue_detail.htm?csnumber=42641."},{"key":"2023033110125178874_j_cclm-2019-0586_ref_008_w2aab3b7d172b1b6b1ab2b1b8Aa","unstructured":"Directive 98\/79\/EC of the European Parliament and of the Council of 27 October 1998 on in vitro diagnostic medical devices. OJ L 331, 7.12.1998, p. 1\u201337. https:\/\/eur-lex.europa.eu\/legal-content\/EN\/TXT\/?qid=1563093961598&uri=CELEX:31998L0079."},{"key":"2023033110125178874_j_cclm-2019-0586_ref_009_w2aab3b7d172b1b6b1ab2b1b9Aa","unstructured":"CLSI. Validation and Verification of Tubes for Venous and Capillary Blood Specimen Collection; Approved Guideline. CLSI document GP34-A. Wayne, PA: Clinical and Laboratory Standards Institute; 2010."},{"key":"2023033110125178874_j_cclm-2019-0586_ref_010_w2aab3b7d172b1b6b1ab2b1c10Aa","doi-asserted-by":"crossref","unstructured":"Lippi G, Cornes MP, Grankvist K, Nybo M, Simundic AM. EFLM WG-Preanalytical phase opinion paper: local validation of blood collection tubes in clinical laboratories. Clin Chem Lab Med 2016;54:755\u201360.","DOI":"10.1515\/cclm-2015-1274"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_011_w2aab3b7d172b1b6b1ab2b1c11Aa","unstructured":"Alsina MJ, \u00c1lvarez V, Bueno M, Cort\u00e9s M, Garc\u00eda Lario JV, Jim\u00e9nez CV, et al. Protocolo para el estudio de la estabilidad de las magnitudes biol\u00f3gicas. Documento A, Fase 3, Versi\u00f3n 1. Qu\u00edmica Cl\u00ednica 2006;25:86\u20139."},{"key":"2023033110125178874_j_cclm-2019-0586_ref_012_w2aab3b7d172b1b6b1ab2b1c12Aa","doi-asserted-by":"crossref","unstructured":"Monneret D, Godmer A, Le Guen R, Bravetti C, Emeraud C, Marteau A, et al. Stability of routine biochemical analytes in whole blood and plasma from lithium heparin gel tubes during 6-hr storage. J Clin Lab Anal 2016;30:602\u20139.","DOI":"10.1002\/jcla.21909"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_013_w2aab3b7d172b1b6b1ab2b1c13Aa","doi-asserted-by":"crossref","unstructured":"Dupuy AM, Cristol JP, Vincent B, Bargnoux AS, Mendes M, Philibert P, et al. Stability of routine biochemical analytes in whole blood and plasma\/serum: focus on potassium stability from lithium heparin. Clin Chem Lab Med 2018;56:413\u201321.","DOI":"10.1515\/cclm-2017-0292"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_014_w2aab3b7d172b1b6b1ab2b1c14Aa","doi-asserted-by":"crossref","unstructured":"Zhang DJ, Elswick RK, Miller WG, Bailey JL. Effect of serum-clot contact time on clinical chemistry laboratory results. Clin Chem 1998;44:1325\u201333.","DOI":"10.1093\/clinchem\/44.6.1325"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_015_w2aab3b7d172b1b6b1ab2b1c15Aa","doi-asserted-by":"crossref","unstructured":"Sureda-Vives M, Morell-Garcia D, Rubio-Alaejos A, Vali\u00f1a L, Robles J, Bau\u00e7a JM. Stability of serum, plasma and urine osmolality in different storage conditions: relevance of temperature and centrifugation. Clin Biochem 2017;50:772\u20136.","DOI":"10.1016\/j.clinbiochem.2017.03.019"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_016_w2aab3b7d172b1b6b1ab2b1c16Aa","doi-asserted-by":"crossref","unstructured":"Remer T, Montenegro-Bethancourt G, Shi L. Long-term urine biobanking: storage stability of clinical chemical parameters under moderate freezing conditions without use of preservatives. Clin Biochem 2014;47:307\u201311.","DOI":"10.1016\/j.clinbiochem.2014.09.009"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_017_w2aab3b7d172b1b6b1ab2b1c17Aa","unstructured":"Sibilia R, Lohff M. Analyte stability in closed containers after 6 days storage. Clin Chem 1989;35:1158."},{"key":"2023033110125178874_j_cclm-2019-0586_ref_018_w2aab3b7d172b1b6b1ab2b1c18Aa","doi-asserted-by":"crossref","unstructured":"Smeenk FW, Janssen JD, Arends BJ, Harff GA, van den Bosch JA, Sch\u00f6nberger JP, et al. Effects of four different methods of sampling arterial blood and storage time on gas tensions and shunt calculations in the 100% oxygen test. Eur Respir J 1997;10:910\u20133.","DOI":"10.1183\/09031936.97.10040910"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_019_w2aab3b7d172b1b6b1ab2b1c19Aa","doi-asserted-by":"crossref","unstructured":"Harsten A, Berg IS, Muth L. Importance of correct handling of samples for the result of blood gas analysis. Acta Anaesthesiol Scand 1988;32:365.","DOI":"10.1111\/j.1399-6576.1988.tb02746.x"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_020_w2aab3b7d172b1b6b1ab2b1c20Aa","doi-asserted-by":"crossref","unstructured":"Muller-Plathe O, Heyduck S. Stability of blood gases, electrolytes, and hemoglobin in heparinized whole blood samples: influence of the type of syringe. Eur J Clin Chem Clin Biochem 1992;30:349\u201355.","DOI":"10.1515\/cclm.1992.30.6.349"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_021_w2aab3b7d172b1b6b1ab2b1c21Aa","doi-asserted-by":"crossref","unstructured":"Baulieu M, Lapointe Y, Vinet B. Stability of PO2, PCO2, and pH in fresh blood samples stored in a plastic syringe with low heparin in relation to various blood-gas and hematological parameters. Clin Biochem 1999;32:101\u20137.","DOI":"10.1016\/S0009-9120(98)00098-8"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_022_w2aab3b7d172b1b6b1ab2b1c22Aa","doi-asserted-by":"crossref","unstructured":"Sofronescu AG, Loebs T, Zhu Y. Effects of temperature and light on the stability of bilirubin in plasma samples. Clin Chim Acta 2012;413:463\u20136.","DOI":"10.1016\/j.cca.2011.10.036"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_023_w2aab3b7d172b1b6b1ab2b1c23Aa","unstructured":"Calam RR. Specimen processing separator gels: an update. J Clin Immunoassay 1988;11:86\u201390."},{"key":"2023033110125178874_j_cclm-2019-0586_ref_024_w2aab3b7d172b1b6b1ab2b1c24Aa","doi-asserted-by":"crossref","unstructured":"Hepburn S, Wright MJ, Boyder C, Sahertian RC, Lu B, Zhang R, et al. Sex steroid hormone stability in serum tubes with and without separator gels. Clin Chem Lab Med 2016;54:1451\u20139.","DOI":"10.1515\/cclm-2015-1133"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_025_w2aab3b7d172b1b6b1ab2b1c25Aa","doi-asserted-by":"crossref","unstructured":"Shah VP, Knapp G, Skully JP, Cabana BE. Interference with measurements of certain drugs in plasma by a plasticizer in vacutainer tubes. Clin Chem 1982;28:2327\u20138.","DOI":"10.1093\/clinchem\/28.11.2327"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_026_w2aab3b7d172b1b6b1ab2b1c26Aa","doi-asserted-by":"crossref","unstructured":"Haller MJ, Schuster JJ, Schatz D, Melker RJ. Adverse impact of temperature and humidity on blood glucose monitoring reliability: a pilot study. Diabetes Technol Ther 2007;9:1\u20139.","DOI":"10.1089\/dia.2006.0051"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_027_w2aab3b7d172b1b6b1ab2b1c27Aa","doi-asserted-by":"crossref","unstructured":"Briscoe CJ, Hage DS. Factors affecting the stability of drugs and drug metabolites in biological matrices. Bioanalysis 2009;1:205\u201320.","DOI":"10.4155\/bio.09.20"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_028_w2aab3b7d172b1b6b1ab2b1c28Aa","doi-asserted-by":"crossref","unstructured":"Ellis JM, Livesey JH, Evans MJ. Hormone stability in human whole blood. Clin Biochem 2003;36:109\u201312.","DOI":"10.1016\/S0009-9120(02)00440-X"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_029_w2aab3b7d172b1b6b1ab2b1c29Aa","doi-asserted-by":"crossref","unstructured":"Diver MJ, Hughes JG, Hutton JL, West CR, Hipkin LJ. The long-term stability in whole blood of 14 commonly-requested hormone analytes. Ann Clin Biochem 1994;31:561\u20135.","DOI":"10.1177\/000456329403100606"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_030_w2aab3b7d172b1b6b1ab2b1c30Aa","doi-asserted-by":"crossref","unstructured":"Livesey JH, Hodgkinson SC, Roud HR, Donald RA. Effect of time, temperature and freezing on the stability of immunoreactive LH, FSH, TSH, growth hormone, prolactin and insulin in plasma. Clin Biochem 1980;13:151\u20135.","DOI":"10.1016\/S0009-9120(80)91040-1"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_031_w2aab3b7d172b1b6b1ab2b1c31Aa","doi-asserted-by":"crossref","unstructured":"Thummel KE, Lin YS. Sources of interindividual variability. Methods Mol Biol 2014;1113:363\u2013415.","DOI":"10.1007\/978-1-62703-758-7_17"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_032_w2aab3b7d172b1b6b1ab2b1c32Aa","unstructured":"Simundic AM, B\u00f6lenius K, Cadamuro J, Church S, Cornes MP, van Dongen-Lases EC, et al. Joint EFLM-COLABIOCLI Recommendation for venous blood sampling. https:\/\/www.eflm.eu\/site\/api\/download\/1453-2.CCLM_2018_EFLM_Guidelines.pdf\/publications\/Joint%20EFLM-COLABIOCLI%20Recommendation%20for%20venous%20blood%20sampling%20v%201.1,%20June%202018."},{"key":"2023033110125178874_j_cclm-2019-0586_ref_033_w2aab3b7d172b1b6b1ab2b1c33Aa","doi-asserted-by":"crossref","unstructured":"Sandberg S, Fraser CG, Horvath AR, Jansen R, Jones G, Oosterhuis W, et al. Defining analytical performance specifications: Consensus Statement from the 1st Strategic Conference of the European Federation of Clinical Chemistry and Laboratory Medicine. Clin Chem Lab Med 2015;53:833\u20135.","DOI":"10.1515\/cclm-2015-0067"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_034_w2aab3b7d172b1b6b1ab2b1c34Aa","doi-asserted-by":"crossref","unstructured":"Aarsand AK, R\u00f8raas T, Fernandez-Calle P, Ricos C, D\u00edaz Garz\u00f3n J, Jonker N, et al. The biological variation data critical appraisal checklist: a standard for evaluating studies on biological variation. Clin Chem 2018;64:501\u201314.","DOI":"10.1373\/clinchem.2017.281808"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_035_w2aab3b7d172b1b6b1ab2b1c35Aa","unstructured":"CLSI. Interference testing in Clinical Chemistry. 3rd ed. CLSI document EP07. Wayne, PA: Clinical and Laboratory Standards Institute, 2018."},{"key":"2023033110125178874_j_cclm-2019-0586_ref_036_w2aab3b7d172b1b6b1ab2b1c36Aa","doi-asserted-by":"crossref","unstructured":"Petersen PH, Fraser CG, Westgard JO, Larsen ML. Analytical goal-setting for monitoring patients when two analytical methods are used. Clin Chem 1992;38:2256\u201360.","DOI":"10.1093\/clinchem\/38.11.2256"},{"key":"2023033110125178874_j_cclm-2019-0586_ref_037_w2aab3b7d172b1b6b1ab2b1c37Aa","unstructured":"Minchinela J, Ric\u00f3s C, Perich C, Fern\u00e1ndez-Calle P, Alvarez V, Dom\u00e9nech MV, et al. Base de datos de los componentes de Variaci\u00f3n Biol\u00f3gica, con las especificaciones de la calidad anal\u00edtica (deseable, m\u00ednima y \u00f3ptima). Actualizaci\u00f3n del a\u00f1o 2014. http:\/\/www.seqc.es\/es\/comisiones\/comision-de-calidad-analitica\/_id:4\/."}],"container-title":["Clinical Chemistry and Laboratory Medicine (CCLM)"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/www.degruyter.com\/view\/j\/cclm.2019.57.issue-12\/cclm-2019-0586\/cclm-2019-0586.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/cclm-2019-0586\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/cclm-2019-0586\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,31]],"date-time":"2023-03-31T11:45:00Z","timestamp":1680263100000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/cclm-2019-0586\/html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7,26]]},"references-count":37,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2019,6,7]]},"published-print":{"date-parts":[[2019,11,26]]}},"alternative-id":["10.1515\/cclm-2019-0586"],"URL":"https:\/\/doi.org\/10.1515\/cclm-2019-0586","relation":{},"ISSN":["1437-4331","1434-6621"],"issn-type":[{"value":"1437-4331","type":"electronic"},{"value":"1434-6621","type":"print"}],"subject":[],"published":{"date-parts":[[2019,7,26]]}}}