{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T22:10:49Z","timestamp":1773958249438,"version":"3.50.1"},"reference-count":8,"publisher":"Walter de Gruyter GmbH","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,1,29]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec id=\"j_cclm-2025-1011_abs_001\">\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>The European Organization for External Quality Assurance Providers in Laboratory Medicine (EQALM) Haematology Working Group (WG) has previously provided two guidelines to support the standardization of hematology blood smear external quality assessment (EQA) (Vives CJL, Albar\u00e8de S, Flandrin G, Heller S, Horvath K, Houwen B, et\u00a0al. Guidelines for blood smear preparation and staining procedure for setting up an external quality assessment scheme for blood smear interpretation. Part I: control material. Clin Chem Lab Med 2004;42:922\u20136; Vives CJL, Van Blerk M, Albar\u00e8de S, Gutierrez G, Heller S, Nordin G, et\u00a0al. Guidelines for setting up an external quality assessment scheme for blood smear interpretation. Part II: survey preparation, statistical evaluation and reporting. Clin Chem Lab Med 2006;44:1039\u201343) but these recommendations did not include analytical performance specifications. In this paper the WG provides advice on the performance specifications for the evaluation of blood cell identification, comments on morphological characteristics and diagnostic hypothesis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"j_cclm-2025-1011_abs_002\">\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>To develop these specifications, the WG made a survey of the practices in use by EQALM members and provided a standard set of EQA data, provided by one of the members, for performance evaluation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"j_cclm-2025-1011_abs_003\">\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The results of this exercise show a variation in the performance assessment outcomes from one EQA provider to another, suggesting that a degree of standardization would be of benefit to participating laboratories.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec id=\"j_cclm-2025-1011_abs_004\">\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The WG has provided advice on common performance specifications, based on model 1 of the Milan Consensus (Sandberg S, Fraser CG, Horvath AR, Jansen R, Jones G, Oosterhuis W, et\u00a0al. Defining analytical performance specifications: consensus statement from the 1st strategic conference of the European federation of clinical chemistry and laboratory medicine. Clin Chem Lab Med 2015;53:833\u20135).<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1515\/cclm-2025-1011","type":"journal-article","created":{"date-parts":[[2025,9,23]],"date-time":"2025-09-23T08:57:47Z","timestamp":1758617867000},"page":"479-488","source":"Crossref","is-referenced-by-count":1,"title":["EQALM recommendations for the analytical performance specifications for blood smear interpretation in hematology: a need for standardization"],"prefix":"10.1515","volume":"64","author":[{"given":"St\u00e9phanie","family":"Albar\u00e8de","sequence":"first","affiliation":[{"name":"CTCB , Toulouse , France"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erika","family":"S\u00e1rk\u00e0ny","sequence":"additional","affiliation":[{"name":"QualiCont In\u00a0Vitro Diagnostic Quality Control Nonprofit Ltd , Szeged , Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Barbara","family":"De la Salle","sequence":"additional","affiliation":[{"name":"UK NEQAS Haematology and Transfusion Operated by the West Herts Teaching Hospitals NHS Trust , Watford , UK"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"374","published-online":{"date-parts":[[2025,9,24]]},"reference":[{"key":"2026031918102570317_j_cclm-2025-1011_ref_001","doi-asserted-by":"crossref","unstructured":"Stavelin, A, Albe, X, Meijer, P, Sarkany, E, MacKenzie, F. An overview of the European organization for external quality assurance providers in laboratory medicine (EQALM). Biochem Med (Zagreb). 2017;27:30\u20136. https:\/\/doi.org\/10.11613\/bm.2017.005.","DOI":"10.11613\/BM.2017.005"},{"key":"2026031918102570317_j_cclm-2025-1011_ref_002","doi-asserted-by":"crossref","unstructured":"Vives, CJL, Albar\u00e8de, S, Flandrin, G, Heller, S, Horvath, K, Houwen, B, et al.. Guidelines for blood smear preparation and staining procedure for setting up an external quality assessment scheme for blood smear interpretation. Part I: control material. Clin Chem Lab Med 2004;42:922\u20136. https:\/\/doi.org\/10.1515\/cclm.2004.149.","DOI":"10.1515\/CCLM.2004.149"},{"key":"2026031918102570317_j_cclm-2025-1011_ref_003","doi-asserted-by":"crossref","unstructured":"Vives, CJL, Van Blerk, M, Albar\u00e8de, S, Gutierrez, G, Heller, S, Nordin, G, et al.. Guidelines for setting up an external quality assessment scheme for blood smear interpretation. Part II: survey preparation, statistical evaluation and reporting. Clin Chem Lab Med 2006;44:1039\u201343. https:\/\/doi.org\/10.1515\/CCLM.2006.174.","DOI":"10.1515\/CCLM.2006.174"},{"key":"2026031918102570317_j_cclm-2025-1011_ref_004","doi-asserted-by":"crossref","unstructured":"Soumali, MR, Van Blerk, M, Akharif, A, Albar\u00e8de, S, Kesseler, D, Gutierrez, G, et al.. A new approach to define acceptance limits for hematology in external quality assessment schemes. Clin Chem Lab Med 2017;55:1936\u201342. https:\/\/doi.org\/10.1515\/cclm-2016-1048.","DOI":"10.1515\/cclm-2016-1048"},{"key":"2026031918102570317_j_cclm-2025-1011_ref_005","doi-asserted-by":"crossref","unstructured":"Sandberg, S, Fraser, CG, Horvath, AR, Jansen, R, Jones, G, Oosterhuis, W, et al.. Defining analytical performance specifications: consensus statement from the 1st strategic conference of the European federation of clinical chemistry and laboratory medicine. Clin Chem Lab Med 2015;53:833\u20135. https:\/\/doi.org\/10.1515\/cclm-2015-0067.","DOI":"10.1515\/cclm-2015-0067"},{"key":"2026031918102570317_j_cclm-2025-1011_ref_006","doi-asserted-by":"crossref","unstructured":"Jones, GRD, Albar\u00e8de, S, Kesseler, D, MacKenzie, F, Mammen, J, Pedersen, M, et al.. Analytical performance specifications for external quality assessment\u00a0\u2013\u00a0definitions and descriptions. Clin Chem Lab Med 2017;55:949\u201355. https:\/\/doi.org\/10.1515\/cclm-2017-0151.","DOI":"10.1515\/cclm-2017-0151"},{"key":"2026031918102570317_j_cclm-2025-1011_ref_007","doi-asserted-by":"crossref","unstructured":"Palmer, L, Briggs, C, McFadden, S, Zini, G, Burthe, J, Rozenberg, G, et al.. ICSH recommendations for standardization of nomenclature and grading of peripheral blood cell morphological features. Int J Lab Hematol 2015;37:287\u2013303. https:\/\/doi.org\/10.1111\/ijlh.12327.","DOI":"10.1111\/ijlh.12327"},{"key":"2026031918102570317_j_cclm-2025-1011_ref_008","doi-asserted-by":"crossref","unstructured":"Zhang, L, Albar\u00e8de, S, Dumont, G, Van Campenhout, C, Libeer, JC, Albert, A. The multivariate coefficient of variation for comparing serum protein electrophoresis techniques in external quality assessment schemes. Accred Qual Assur 2010;15:3\u201310.","DOI":"10.1007\/s00769-009-0627-3"}],"container-title":["Clinical Chemistry and Laboratory Medicine (CCLM)"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.degruyterbrill.com\/document\/doi\/10.1515\/cclm-2025-1011\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.degruyterbrill.com\/document\/doi\/10.1515\/cclm-2025-1011\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,19]],"date-time":"2026-03-19T18:12:31Z","timestamp":1773943951000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.degruyterbrill.com\/document\/doi\/10.1515\/cclm-2025-1011\/html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9,24]]},"references-count":8,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025,9,12]]},"published-print":{"date-parts":[[2026,1,29]]}},"alternative-id":["10.1515\/cclm-2025-1011"],"URL":"https:\/\/doi.org\/10.1515\/cclm-2025-1011","relation":{},"ISSN":["1434-6621","1437-4331"],"issn-type":[{"value":"1434-6621","type":"print"},{"value":"1437-4331","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,9,24]]}}}