{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,6,23]],"date-time":"2023-06-23T00:30:12Z","timestamp":1687480212721},"reference-count":54,"publisher":"Walter de Gruyter GmbH","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2019,8,27]]},"abstract":"<jats:title>Abstract<\/jats:title>\n<jats:sec id=\"j_jpm-2019-0083_s_999\">\n<jats:title id=\"d11421495e40178\">Objective<\/jats:title>\n<jats:p>To understand the impact of the measurement method to predict actual birthweight in pregnancies complicated with isolated polyhydramnios in the third trimester.<\/jats:p><\/jats:sec>\n<jats:sec id=\"j_jpm-2019-0083_s_998\">\n<jats:title id=\"d11421495e40186\">Methods<\/jats:title>\n<jats:p>A prospective study was conducted with 60 pregnant women between the 37<jats:sup>th<\/jats:sup> and 40<jats:sup>th<\/jats:sup> weeks of gestation. Routine biometric measurements were obtained by two-dimensional (2D) ultrasonography. When a satisfactory image was obtained, the image was frozen to get two measurements. First, calipers were placed to get the manual measurement. Then automated measurement was captured by the ultrasonography machine in the same image. The fetal weight was estimated by using the Hadlock II formula.<\/jats:p><\/jats:sec>\n<jats:sec id=\"j_jpm-2019-0083_s_997\">\n<jats:title id=\"d11421495e40200\">Results<\/jats:title>\n<jats:p>The mean difference was found to be 0.03, \u22120.77, \u22120.02 and 0.17 for biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur length (FL), respectively. Pearson\u2019s correlation coefficient between automated and manual estimated fetal weights (EFWs) and the actual birthweight was 0.919 and 0.796, respectively. The mean difference between actual and manual EFW measurement values was 46.16 \u00b1 363.81 g (range between \u2212745 g and 685 g) (P = 0.330). Also, the mean difference between actual and automated EFW measurement values was found to be 31.98 \u00b1 218.65 g (range between \u2212378 g and 742 g) (P = 0.262). The Bland-Altman test results have shown that, 666 g lower or 759 g higher values were obtained when the measurement was performed manually. On the other hand, EFW results were 396 g lower or 460 g higher than the actual birthweight with automated measurement tools.<\/jats:p><\/jats:sec>\n<jats:sec id=\"j_jpm-2019-0083_s_996\">\n<jats:title id=\"d11421495e40208\">Conclusion<\/jats:title>\n<jats:p>The accuracy rate of fetal weight estimation with ultrasonography is high for both automated and manual measurements. Automated tools have a higher success to predict the EFW.<\/jats:p><\/jats:sec>","DOI":"10.1515\/jpm-2019-0083","type":"journal-article","created":{"date-parts":[[2019,5,29]],"date-time":"2019-05-29T09:03:03Z","timestamp":1559120583000},"page":"592-597","source":"Crossref","is-referenced-by-count":2,"title":["Comparison of automated vs. manual measurement to estimate fetal weight in isolated polyhydramnios"],"prefix":"10.1515","volume":"47","author":[{"given":"Hasan","family":"Eroglu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gokcen","family":"Orgul","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emine","family":"Avc\u0131","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Orhan","family":"Alt\u0131nboga","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gokhan","family":"Karakoc","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Aykan","family":"Yucel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"374","reference":[{"key":"ref91","article-title":"Evaluation of automated tool for 2D fetal biometry","year":"2018","journal-title":"Ultrasound Obstet Gynecol"},{"key":"ref451","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/S0002-9378(00)70513-8","article-title":"Morbidity and mortality among very-low-birth-weight neonates with intrauterine growth restriction","volume":"182","year":"2000","journal-title":"Am J Obstet Gynecol"},{"key":"ref461","doi-asserted-by":"crossref","first-page":"381","DOI":"10.7863\/jum.1991.10.7.381","article-title":"Automatic measurements of fetal long bones. A feasibility study","volume":"10","year":"1991","journal-title":"J Ultrasound Med"},{"key":"ref291","first-page":"1","article-title":"Importance of routine ultrasonography in detecting fetal karyotype abnormalities in low risk pregnancies","volume":"18","year":"2012","journal-title":"Gynecol Obstet Reprod Med"},{"key":"ref201","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1016\/S1076-6332(96)80187-5","article-title":"Automatic fetal head measurements from sonographic images","volume":"3","year":"1996","journal-title":"Acad Radiol"},{"key":"ref171","doi-asserted-by":"crossref","first-page":"198","DOI":"10.1016\/S0002-9378(00)70513-8","article-title":"Morbidity and mortality among very-low-birth-weight neonates with intrauterine growth restriction","volume":"182","year":"2000","journal-title":"Am J Obstet Gynecol"},{"key":"ref501","first-page":"145","article-title":"Incidence and sonographic detection of fetal anomalies in pregnancies complicated by polyhydramnios","volume":"14","year":"2008","journal-title":"Gynecol Obstet Reprod Med"},{"key":"ref251","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1177\/8756479305278267","article-title":"The effect of amniotic fluid index on the accuracy of sonographic estimated fetal weight","volume":"21","year":"2005","journal-title":"J Diagn Med Sonogr"},{"key":"ref261","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1097\/RUQ.0000000000000275","article-title":"The effect of the amniotic fluid index on the accuracy of ultrasonographic-estimated fetal weight","volume":"33","year":"2017","journal-title":"Ultrasound Q"},{"key":"ref101","doi-asserted-by":"crossref","first-page":"847","DOI":"10.7863\/jum.2013.32.5.847","article-title":"Does the use of automated fetal biometry improve clinical work flow efficiency?","volume":"32","year":"2013","journal-title":"J Ultrasound Med"},{"key":"ref281","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1186\/s12978-018-0571-y","article-title":"Obstetric ultrasound use in low and middle income countries: a narrative review","volume":"15","year":"2018","journal-title":"Reprod Health"},{"key":"ref321","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1002\/uog.19066","article-title":"Ultrasonographic estimation of fetal weight: development of new model and assessment of performance of previous models","volume":"52","year":"2018","journal-title":"Ultrasound Obstet Gynecol"},{"key":"ref531","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1177\/8756479305278267","article-title":"The effect of amniotic fluid index on the accuracy of sonographic estimated fetal weight","volume":"21","year":"2005","journal-title":"J Diagn Med Sonogr"},{"key":"ref521","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1111\/j.1447-0756.2009.01145.x","article-title":"Peripartum outcomes of high-risk pregnancies complicated by oligo- and polyhydramnios: a prospective longitudinal study","volume":"36","year":"2010","journal-title":"J Obstet Gynaecol Res"},{"key":"ref401","first-page":"815","article-title":"Assessment of the accuracy of multiple sonographic fetal weight estimation formulas: a 10-year experience from a single center","volume":"32","year":"2013","journal-title":"J Ultrasound Med"},{"key":"ref51","doi-asserted-by":"crossref","first-page":"103","DOI":"10.7863\/ultra.15.02040","article-title":"Third-trimester fetal biometry and neonatal outcomes in term and preterm deliveries","volume":"35","year":"2016","journal-title":"J Ultrasound Med"},{"key":"ref391","doi-asserted-by":"crossref","first-page":"2","DOI":"10.4103\/2156-7514.106614","article-title":"Relationship between amniotic fluid index and ultrasound estimated fetal weight in healthy pregnant African women","volume":"3","year":"2013","journal-title":"J Clin Imaging Sci"},{"key":"ref491","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.ajog.2018.07.016","article-title":"SMFM Consult Series #46: evaluation and management of polyhydramnios","volume":"219","year":"2018","journal-title":"Am J Obstet Gynecol"},{"key":"ref31","doi-asserted-by":"crossref","first-page":"7093","DOI":"10.1038\/s41598-018-25497-3","article-title":"Association between amniotic fluid evaluation and fetal biometry: a prospective French \u201cFlash\u201d study","volume":"8","year":"2018","journal-title":"Sci Rep"},{"key":"ref111","doi-asserted-by":"crossref","first-page":"2","DOI":"10.4103\/2156-7514.106614","article-title":"Relationship between amniotic fluid index and ultrasound estimated fetal weight in healthy pregnant African women","volume":"3","year":"2013","journal-title":"J Clin Imaging Sci"},{"key":"ref271","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.7863\/jum.2009.28.8.1019","article-title":"Is sonographic assessment of fetal weight influenced by formula selection?","volume":"28","year":"2009","journal-title":"J Ultrasound Med"},{"key":"ref331","doi-asserted-by":"crossref","first-page":"103","DOI":"10.7863\/ultra.15.02040","article-title":"Third-trimester fetal biometry and neonatal outcomes in term and preterm deliveries","volume":"35","year":"2016","journal-title":"J Ultrasound Med"},{"key":"ref421","first-page":"1","article-title":"Amniotic fluid index versus single deepest vertical pocket as a screening test for preventing adverse pregnancy outcome","volume":"3","year":"2008","journal-title":"Cochrane Database Syst"},{"key":"ref141","first-page":"1","article-title":"Amniotic fluid index versus single deepest vertical pocket as a screening test for preventing adverse pregnancy outcome","volume":"3","year":"2008","journal-title":"Cochrane Database Syst"},{"key":"ref371","article-title":"Evaluation of automated tool for 2D fetal biometry","year":"2018","journal-title":"Ultrasound Obstet Gynecol"},{"key":"ref551","doi-asserted-by":"crossref","first-page":"1019","DOI":"10.7863\/jum.2009.28.8.1019","article-title":"Is sonographic assessment of fetal weight influenced by formula selection?","volume":"28","year":"2009","journal-title":"J Ultrasound Med"},{"key":"ref21","doi-asserted-by":"crossref","first-page":"113S","DOI":"10.1097\/01.AOG.0000483465.54962.f0","article-title":"Accuracy of sonographic fetal biometry measurements [26M]","volume":"127","year":"2016","journal-title":"Obstet Gynecol"},{"key":"ref301","doi-asserted-by":"crossref","first-page":"113S","DOI":"10.1097\/01.AOG.0000483465.54962.f0","article-title":"Accuracy of sonographic fetal biometry measurements [26M]","volume":"127","year":"2016","journal-title":"Obstet Gynecol"},{"key":"ref211","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.ajog.2018.07.016","article-title":"SMFM Consult Series #46: evaluation and management of polyhydramnios","volume":"219","year":"2018","journal-title":"Am J Obstet Gynecol"},{"key":"ref351","doi-asserted-by":"crossref","first-page":"710","DOI":"10.3109\/01443615.2016.1148126","article-title":"Intrapartum, postpartum characteristics and early neonatal outcomes of idiopathic polyhydramnios","volume":"36","year":"2016","journal-title":"J Obstet Gynaecol"},{"key":"ref411","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1002\/pd.4250","article-title":"Sonographic fetal weight estimation\u2013is there more to it than just fetal measurements?","volume":"34","year":"2014","journal-title":"Prenat Diagn"},{"key":"ref311","doi-asserted-by":"crossref","first-page":"7093","DOI":"10.1038\/s41598-018-25497-3","article-title":"Association between amniotic fluid evaluation and fetal biometry: a prospective French \u201cFlash\u201d study","volume":"8","year":"2018","journal-title":"Sci Rep"},{"key":"ref361","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1080\/14767050802415736","article-title":"Fetal biometry: a comparison between experienced sonographers and automated measurements","volume":"22","year":"2009","journal-title":"J Matern Fetal Neonatal Med"},{"key":"ref191","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1016\/j.ultrasmedbio.2018.09.015","article-title":"Automated fetal head detection and circumference estimation from free-hand ultrasound sweeps using deep learning in resource-limited countries","volume":"45","year":"2019","journal-title":"Ultrasound Med Biol"},{"key":"ref61","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1159\/000338659","article-title":"Idiopathic polyhydramnios and postnatal abnormalities","volume":"32","year":"2012","journal-title":"Fetal Diag Ther"},{"key":"ref41","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1002\/uog.19066","article-title":"Ultrasonographic estimation of fetal weight: development of new model and assessment of performance of previous models","volume":"52","year":"2018","journal-title":"Ultrasound Obstet Gynecol"},{"key":"ref71","doi-asserted-by":"crossref","first-page":"710","DOI":"10.3109\/01443615.2016.1148126","article-title":"Intrapartum, postpartum characteristics and early neonatal outcomes of idiopathic polyhydramnios","volume":"36","year":"2016","journal-title":"J Obstet Gynaecol"},{"key":"ref241","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1111\/j.1447-0756.2009.01145.x","article-title":"Peripartum outcomes of high-risk pregnancies complicated by oligo- and polyhydramnios: a prospective longitudinal study","volume":"36","year":"2010","journal-title":"J Obstet Gynaecol Res"},{"key":"ref181","doi-asserted-by":"crossref","first-page":"381","DOI":"10.7863\/jum.1991.10.7.381","article-title":"Automatic measurements of fetal long bones. A feasibility study","volume":"10","year":"1991","journal-title":"J Ultrasound Med"},{"key":"ref381","doi-asserted-by":"crossref","first-page":"847","DOI":"10.7863\/jum.2013.32.5.847","article-title":"Does the use of automated fetal biometry improve clinical work flow efficiency?","volume":"32","year":"2013","journal-title":"J Ultrasound Med"},{"key":"ref221","first-page":"145","article-title":"Incidence and sonographic detection of fetal anomalies in pregnancies complicated by polyhydramnios","volume":"14","year":"2008","journal-title":"Gynecol Obstet Reprod Med"},{"key":"ref161","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/S0002-9378(97)70435-6","article-title":"Incidence of persistent birth injury in macrosomic infants: association with mode of delivery","volume":"177","year":"1997","journal-title":"Am J Obstet Gynecol"},{"key":"ref541","doi-asserted-by":"crossref","first-page":"148","DOI":"10.1097\/RUQ.0000000000000275","article-title":"The effect of the amniotic fluid index on the accuracy of ultrasonographic-estimated fetal weight","volume":"33","year":"2017","journal-title":"Ultrasound Q"},{"key":"ref11","first-page":"1","article-title":"Importance of routine ultrasonography in detecting fetal karyotype abnormalities in low risk pregnancies","volume":"18","year":"2012","journal-title":"Gynecol Obstet Reprod Med"},{"key":"ref231","doi-asserted-by":"crossref","first-page":"1115","DOI":"10.1111\/j.1471-0528.1990.tb02499.x","article-title":"Polyhydramnios and associated maternal and fetal complications in singleton pregnancies","volume":"97","year":"1990","journal-title":"Br J Obstect Gynecol"},{"key":"ref01","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1186\/s12978-018-0571-y","article-title":"Obstetric ultrasound use in low and middle income countries: a narrative review","volume":"15","year":"2018","journal-title":"Reprod Health"},{"key":"ref81","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1080\/14767050802415736","article-title":"Fetal biometry: a comparison between experienced sonographers and automated measurements","volume":"22","year":"2009","journal-title":"J Matern Fetal Neonatal Med"},{"key":"ref511","doi-asserted-by":"crossref","first-page":"1115","DOI":"10.1111\/j.1471-0528.1990.tb02499.x","article-title":"Polyhydramnios and associated maternal and fetal complications in singleton pregnancies","volume":"97","year":"1990","journal-title":"Br J Obstect Gynecol"},{"key":"ref481","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1016\/S1076-6332(96)80187-5","article-title":"Automatic fetal head measurements from sonographic images","volume":"3","year":"1996","journal-title":"Acad Radiol"},{"key":"ref341","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1159\/000338659","article-title":"Idiopathic polyhydramnios and postnatal abnormalities","volume":"32","year":"2012","journal-title":"Fetal Diag Ther"},{"key":"ref441","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/S0002-9378(97)70435-6","article-title":"Incidence of persistent birth injury in macrosomic infants: association with mode of delivery","volume":"177","year":"1997","journal-title":"Am J Obstet Gynecol"},{"key":"ref121","first-page":"815","article-title":"Assessment of the accuracy of multiple sonographic fetal weight estimation formulas: a 10-year experience from a single center","volume":"32","year":"2013","journal-title":"J Ultrasound Med"},{"key":"ref131","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1002\/pd.4250","article-title":"Sonographic fetal weight estimation\u2013is there more to it than just fetal measurements?","volume":"34","year":"2014","journal-title":"Prenat Diagn"},{"key":"ref471","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1016\/j.ultrasmedbio.2018.09.015","article-title":"Automated fetal head detection and circumference estimation from free-hand ultrasound sweeps using deep learning in resource-limited countries","volume":"45","year":"2019","journal-title":"Ultrasound Med Biol"}],"container-title":["Journal of Perinatal Medicine"],"original-title":[],"link":[{"URL":"http:\/\/www.degruyter.com\/view\/j\/jpme.2019.47.issue-6\/jpm-2019-0083\/jpm-2019-0083.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/jpm-2019-0083\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,22]],"date-time":"2021-04-22T01:36:34Z","timestamp":1619055394000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/jpm-2019-0083\/html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,8,27]]},"references-count":54,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.1515\/jpm-2019-0083","relation":{},"ISSN":["1619-3997","0300-5577"],"issn-type":[{"value":"1619-3997","type":"electronic"},{"value":"0300-5577","type":"print"}],"subject":[],"published":{"date-parts":[[2019,8,27]]}}}