{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,25]],"date-time":"2025-07-25T10:24:58Z","timestamp":1753439098158,"version":"3.34.0"},"reference-count":23,"publisher":"Walter de Gruyter GmbH","issue":"1","license":[{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/3.0"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,8,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Clinicians often rely on selected small molecular compounds from body fluids for the detection, screening or monitoring of numerous life-threatening diseases. Among others, important monoamines \u2013 biogenic amines (BAs) \u2013 and their metabolites serve as sensitive biomarkers to study the progression or even early detection of on-going brain pathologies or tumors of neuroendocrine origins. Undertaking the task to optimize a reliable method for the simultaneous analysis of the most relevant BAs in biological matrices is of utmost importance for scientists.<\/jats:p>\n               <jats:p>Hydrophilic interaction liquid chromatography (HILIC) with mass spectrometry (MS) detection provides a specific and sensitive technique for the separation and assessment of several neurotransmitter concentrations in body fluids (blood, urine, tissues). The present study was focused on the optimization of a straightforward, sensitive and reliable method for the simultaneous analysis of the ten most important BAs and their acidic metabolites from homogenates of rat brain tissues by use of HILIC-MS. Here, we present the optimized experimental workflow in terms of sample preparation, buffer compositions, HILIC and MS settings and data analysis.<\/jats:p>\n               <jats:p>The presented method is reliable, straightforward and sensitive. Our method permits the unbiased, qualitative and quantitative determination of several BAs and their metabolites simultaneously. The optimized method was applied to the analysis of rat brain tissue samples from healthy hemispheres or those with induced transient ischemic attack (TIA). The undertaken pilot study demonstrated that the proposed approach could be applied to reveal the perturbation in neurotransmitters concentration after TIA in rat brains.<\/jats:p>","DOI":"10.1515\/tnsci-2017-0012","type":"journal-article","created":{"date-parts":[[2017,8,13]],"date-time":"2017-08-13T10:02:40Z","timestamp":1502618560000},"page":"70-75","source":"Crossref","is-referenced-by-count":6,"title":["HILIC-MS rat brain analysis, a new approach for the study of ischemic attack"],"prefix":"10.1515","volume":"8","author":[{"given":"Natalia","family":"Mi\u0119kus","sequence":"first","affiliation":[{"name":"Department of Animal and Human Physiology , University of Gda\u0144sk , Wita Stwosza 59, 80-308 Gda\u0144sk , Poland"},{"name":"Department of Pharmaceutical Chemistry , Medical University of Gda\u0144sk , Gen. J. Hallera 107, 80-416 Gda\u0144sk , Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lucyna","family":"Konieczna","sequence":"additional","affiliation":[{"name":"Department of Pharmaceutical Chemistry , Medical University of Gda\u0144sk , Gen. J. Hallera 107, 80-416 Gda\u0144sk , Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Przemys\u0142aw","family":"Kowia\u0144ski","sequence":"additional","affiliation":[{"name":"Department of Anatomy and Neurobiology , Medical University of Gda\u0144sk , D\u0119binki 1, 80-211 Gda\u0144sk , Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Janusz","family":"Mory\u015b","sequence":"additional","affiliation":[{"name":"Department of Anatomy and Neurobiology , Medical University of Gda\u0144sk , D\u0119binki 1, 80-211 Gda\u0144sk , Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomasz","family":"B\u0105czek","sequence":"additional","affiliation":[{"name":"Department of Pharmaceutical Chemistry , Medical University of Gda\u0144sk , Gen. J. Hallera 107, 80-416 Gda\u0144sk , Poland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"374","published-online":{"date-parts":[[2017,8,12]]},"reference":[{"key":"2025012923072366068_j_tnsci-2017-0012_ref_001_w2aab2b8d144b1b7b1ab2b2b1Aa","doi-asserted-by":"crossref","unstructured":"Mi\u0119kus N., Kowalski P., Ol\u0119dzka I., Plenis A., Bie\u0144 E., Mi\u0119kus A., et al., Cyclodextrin-modified MEKC method for quantification of selected acidic metabolites of catecholamines in the presence of various biogenic amines. Application to diagnosis of neuroblastoma, J. Chromatogr. B. Analyt. Technol. Biomed. Life Sci.1003, 2015, 27\u201334.","DOI":"10.1016\/j.jchromb.2015.09.003"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_002_w2aab2b8d144b1b7b1ab2b2b2Aa","doi-asserted-by":"crossref","unstructured":"Salkovic-Petrisic M., Knezovic A., Hoyer S., Riederer P., What have we learned from the streptozotocin-induced animal model of sporadic Alzheimer\u2019s disease, about the therapeutic strategies in Alzheimer\u2019s research, J. Neural Transm. 120, 2013, 233\u2013252.","DOI":"10.1007\/s00702-012-0877-9"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_003_w2aab2b8d144b1b7b1ab2b2b3Aa","doi-asserted-by":"crossref","unstructured":"Chirita R.I., West C., Finaru A.L., Elfakir C., Approach to hydrophilic interaction chromatography column selection: Application to neurotransmitters analysis, J. Chromatogr. A. 1217, 2010, 3091\u20133104.","DOI":"10.1016\/j.chroma.2010.03.001"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_004_w2aab2b8d144b1b7b1ab2b2b4Aa","doi-asserted-by":"crossref","unstructured":"Montaner J., Perea-Gainza M., Delgado P., Rib\u00f3 M., Chac\u00f3n P., Rosell A., et al., Etiologic Diagnosis of Ischemic Stroke Subtypes With Plasma Biomarkers, Stroke. 39, 2008, 2280-2287.","DOI":"10.1161\/STROKEAHA.107.505354"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_005_w2aab2b8d144b1b7b1ab2b2b5Aa","doi-asserted-by":"crossref","unstructured":"Whiteley W., Wardlaw J., Dennis M., Lowe G., Rumley A., Sattar N., et al., The Use of Blood Biomarkers to Predict Poor Outcome After Acute Transient Ischemic Attack or Ischemic Stroke, Stroke. 43, 2011, 86-91.","DOI":"10.1161\/STROKEAHA.111.634089"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_006_w2aab2b8d144b1b7b1ab2b2b6Aa","doi-asserted-by":"crossref","unstructured":"Laskowitz D.T., Kasner S.E., Saver J., Remmel K.S., Clinical usefulness of a biomarker-based diagnostic test for acute stroke: the Biomarker Rapid Assessment in Ischemic Injury (BRAIN) study., Stroke. 1217, 2009, 3091-3104.","DOI":"10.1161\/STROKEAHA.108.516377"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_007_w2aab2b8d144b1b7b1ab2b2b7Aa","doi-asserted-by":"crossref","unstructured":"Feng C., Fang M., Liu X.Y., The neurobiological pathogenesis of poststroke depression., Scientific World Journal, 2014, 1-8.","DOI":"10.1155\/2014\/521349"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_008_w2aab2b8d144b1b7b1ab2b2b8Aa","doi-asserted-by":"crossref","unstructured":"Ferrarese C., Bassi S., Frattola L., Locatelli P., Piolti R., Trabucchi M., Different patterns of CSF neurotransmitter metabolism in patients with left or right hemispheric stroke, Acta Neurol. Scand. 73, 1986, 581\u2013585.","DOI":"10.1111\/j.1600-0404.1986.tb04603.x"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_009_w2aab2b8d144b1b7b1ab2b2b9Aa","doi-asserted-by":"crossref","unstructured":"Gianotti V., Chiuminatto U., Mazzucco E., Gosetti F., Bottaro M., Frascarolo P., et al. A new hydrophilic interaction liquid chromatography tandem mass spectrometry method for the simultaneous determination of seven biogenic amines in cheese, J. Chromatogr. A. 1185, 2008, 296\u2013300.","DOI":"10.1016\/j.chroma.2008.02.038"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_010_w2aab2b8d144b1b7b1ab2b2c10Aa","doi-asserted-by":"crossref","unstructured":"Danaceau J.P., Chambers E.E., Fountain K.J., Hydrophilic interaction chromatography (HILIC) for LC-MS\/MS analysis of monoamine neurotransmitters, Bioanalysis. 4, 2012, 783\u2013794.","DOI":"10.4155\/bio.12.46"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_011_w2aab2b8d144b1b7b1ab2b2c11Aa","doi-asserted-by":"crossref","unstructured":"Gosetti F., Mazzucco E., Gennaro M.C., Marengo E., Simultaneous determination of sixteen underivatized biogenic amines in human urine by HPLC-MS\/MS, Anal. Bioanal. Chem. 405, 2013, 907\u2013916.","DOI":"10.1007\/s00216-012-6269-z"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_012_w2aab2b8d144b1b7b1ab2b2c12Aa","doi-asserted-by":"crossref","unstructured":"Hasanzadeh M., Shadjou N., Omidinia E., A novel electroanalytical method for simultaneous detection of two neurotransmitter dopamine and serotonin in human serum, J. Neurosci. Methods. 219, 2013, 52\u201360.","DOI":"10.1016\/j.jneumeth.2013.07.007"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_013_w2aab2b8d144b1b7b1ab2b2c13Aa","doi-asserted-by":"crossref","unstructured":"Kema I.P., Meijer W.G., Meiborg G., Ooms B., Willemse P.H., de Vries E.G., Profiling of tryptophan-related plasma indoles in patients with carcinoid tumors by automated, on-line, solid-phase extraction and HPLC with fluorescence detection., Clin. Chem. 47, 2001, 1811\u20131820.","DOI":"10.1093\/clinchem\/47.10.1811"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_014_w2aab2b8d144b1b7b1ab2b2c14Aa","doi-asserted-by":"crossref","unstructured":"Vl\u010dkov\u00e1 M., Schwarz M.A., Determination of cationic neurotransmitters and metabolites in brain homogenates by microchip electrophoresis and carbon nanotube-modified amperometry, J. Chromatogr. A. 1142, 2007, 214\u2013221.","DOI":"10.1016\/j.chroma.2006.12.040"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_015_w2aab2b8d144b1b7b1ab2b2c15Aa","doi-asserted-by":"crossref","unstructured":"Rom\u00e1n D.A., Carretero A.S., Blanco C.C., Guti\u00e9rrez A.F., Subminute and sensitive determination of the neurotransmitter serotonin in urine by capillary electrophoresis with laser-inducedfluorescence detection, Biomed. Chromatogr.18, 2004, 422\u2013426.","DOI":"10.1002\/bmc.330"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_016_w2aab2b8d144b1b7b1ab2b2c16Aa","doi-asserted-by":"crossref","unstructured":"de Jong W.H.A., de Vries E.G.E., Kema I.P., Current status and future developments of LC-MS\/MS in clinical chemistry for quantification of biogenic amines, Clin. Biochem. 44, 2011, 95\u2013103.","DOI":"10.1016\/j.clinbiochem.2010.07.006"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_017_w2aab2b8d144b1b7b1ab2b2c17Aa","doi-asserted-by":"crossref","unstructured":"Fluri F., Schuhmann M.K., Kleinschnitz C., Animal models of ischemic stroke and their application in clinical research., Drug Des. Devel. Ther. 9, 2015, 3445\u20133454.","DOI":"10.2147\/DDDT.S56071"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_018_w2aab2b8d144b1b7b1ab2b2c18Aa","doi-asserted-by":"crossref","unstructured":"Bederson J.B., Pitts L.H., Tsuji M., Nishimura M.C., Davis R.L., Bartkowski H., Rat middle cerebral artery occlusion: evaluation of the model and development of a neurologic examination, Stroke. 17, 1986, 472\u2013476.","DOI":"10.1161\/01.STR.17.3.472"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_019_w2aab2b8d144b1b7b1ab2b2c19Aa","doi-asserted-by":"crossref","unstructured":"Mallet C.R., Lu Z., Mazzeo J.R., A study of ion suppression effects in electrospray ionization from mobile phase additives and solid-phase extracts, Rapid Commun. Mass Spectrom.18, 2004, 49\u201358.","DOI":"10.1002\/rcm.1276"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_020_w2aab2b8d144b1b7b1ab2b2c20Aa","doi-asserted-by":"crossref","unstructured":"Guzman D.C., Garcia E.H., Mejia G.B., Olguin H.J., Gonzalez J.A.S., Labra Ruiz N.A., Effect of morphine and lacosamide on levels of dopamine and 5-HIAA in brain regions of rats with induced hypoglycemia., Pakistan J. Biol. Sci.17, 2014, 292\u2013296.","DOI":"10.3923\/pjbs.2014.292.296"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_021_w2aab2b8d144b1b7b1ab2b2c21Aa","doi-asserted-by":"crossref","unstructured":"Alpert A.J., Hydrophilic-interaction chromatography for the separation of peptides, nucleic acids and other polar compounds., J. Chromatogr. 499, 1990, 177\u2013196.","DOI":"10.1016\/S0021-9673(00)96972-3"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_022_w2aab2b8d144b1b7b1ab2b2c22Aa","doi-asserted-by":"crossref","unstructured":"Hemstr\u00f6m P., Irgum K., Hydrophilic interaction chromatography, J. Sep. Sci. 29, 2006, 1784\u20131821.","DOI":"10.1002\/jssc.200600199"},{"key":"2025012923072366068_j_tnsci-2017-0012_ref_023_w2aab2b8d144b1b7b1ab2b2c23Aa","doi-asserted-by":"crossref","unstructured":"Buszewski B., Noga S., Hydrophilic interaction liquid chromatography (HILIC) - a powerful separation technique, Anal. Bioanal. Chem. 402, 2012, 231\u2013247.","DOI":"10.1007\/s00216-011-5308-5"}],"container-title":["Translational Neuroscience"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.degruyter.com\/view\/journals\/tnsci\/8\/1\/article-p70.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/tnsci-2017-0012\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/tnsci-2017-0012\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,1,29]],"date-time":"2025-01-29T23:07:34Z","timestamp":1738192054000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/tnsci-2017-0012\/html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1,1]]},"references-count":23,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2017,8,12]]},"published-print":{"date-parts":[[2017,8,12]]}},"alternative-id":["10.1515\/tnsci-2017-0012"],"URL":"https:\/\/doi.org\/10.1515\/tnsci-2017-0012","relation":{},"ISSN":["2081-6936"],"issn-type":[{"type":"electronic","value":"2081-6936"}],"subject":[],"published":{"date-parts":[[2017,1,1]]}}}