{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T17:36:53Z","timestamp":1790789813361,"version":"4.1.0"},"reference-count":19,"publisher":"Walter de Gruyter GmbH","issue":"1","license":[{"start":{"date-parts":[[2022,11,23]],"date-time":"2022-11-23T00:00:00Z","timestamp":1669161600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100010661","name":"Horizon 2020 Framework Programme","doi-asserted-by":"publisher","award":["18HLT08 MeDD II"],"award-info":[{"award-number":["18HLT08 MeDD II"]}],"id":[{"id":"10.13039\/100010661","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,2,23]]},"abstract":"<jats:title>Abstract<\/jats:title>\n               <jats:p>Almost every medical department in hospitals around the world uses infusion devices to administer fluids, nutrition, and medications to patients to treat many different diseases and ailments. There have been several reports on adverse incidents caused by medication errors associated with infusion equipment. Such errors can result from malfunction or improper use, or even inaccuracy of\u00a0the equipment, and can cause harm to patients\u2019 health. Depending on the intended use of the equipment, e.g. if it is used for anaesthesia of adults or for medical treatment of premature infants, the accuracy of the equipment may be more or less important. A well-defined metrological infrastructure can help to ensure that infusion devices function properly and are as accurate as needed for their use. However, establishing a metrological infrastructure requires adequate knowledge of the performance of infusion devices in use. This paper presents the results of various tests conducted with two types of devices.<\/jats:p>","DOI":"10.1515\/bmt-2022-0053","type":"journal-article","created":{"date-parts":[[2022,11,23]],"date-time":"2022-11-23T17:34:25Z","timestamp":1669224865000},"page":"51-65","source":"Crossref","is-referenced-by-count":6,"title":["Assessment of drug delivery devices working at microflow rates"],"prefix":"10.1515","volume":"68","author":[{"given":"Anders Koustrup","family":"Niemann","sequence":"first","affiliation":[{"name":"Calibration and Measurement Technology , Danish Technological Institute , Aarhus C , Denmark"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elsa","family":"Batista","sequence":"additional","affiliation":[{"name":"Metrology Department , Portuguese Institute for Quality , Caparica , Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jan","family":"Ger\u0161l","sequence":"additional","affiliation":[{"name":"Department of Primary Metrology of Liquids Flow, Flow Velocity and Heat , CMI , Brno , Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hugo","family":"Bissig","sequence":"additional","affiliation":[{"name":"Physics , Federal Institute of Metrology METAS , Bern-Wabern , Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5118-0150","authenticated-orcid":false,"given":"Oliver","family":"B\u00fcker","sequence":"additional","affiliation":[{"name":"RISE Research Institutes of Sweden , Bor\u00e5s , Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seok Hwan","family":"Lee","sequence":"additional","affiliation":[{"name":"Thermometry and Fluid Flow Metrology Group, Division of Physical Metrology , KRISS , Daejeon , South Korea"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emmelyn","family":"Graham","sequence":"additional","affiliation":[{"name":"Life Sciences & Healthcare , TUV SUD NEL , East Kilbride, Glasgow , UK"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Krister","family":"Stolt","sequence":"additional","affiliation":[{"name":"RISE Research Institutes of Sweden , Bor\u00e5s , Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joana","family":"Afonso","sequence":"additional","affiliation":[{"name":"UNIDEMI, Department of Mechanical and Industrial Engineering , NOVA School of Science and Technology , Caparica , Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Miroslava","family":"Benkov\u00e1","sequence":"additional","affiliation":[{"name":"Department of Primary Metrology of Liquids Flow, Flow Velocity and Heat , CMI , Brno , Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stanislav","family":"Knotek","sequence":"additional","affiliation":[{"name":"Department of Primary Metrology of Liquids Flow, Flow Velocity and Heat , CMI , Brno , Czech Republic"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"374","published-online":{"date-parts":[[2022,11,23]]},"reference":[{"key":"2023033113282394433_j_bmt-2022-0053_ref_001","unstructured":"White paper: infusion pump improvement initiative: Center for Devices and Radiological Health U.S. Food and Drug Administration; 2010. Available from: https:\/\/www.fda.gov\/medical-devices\/infusion-pumps\/white-paper-infusion-pump-improvement-initiative."},{"key":"2023033113282394433_j_bmt-2022-0053_ref_002","doi-asserted-by":"crossref","unstructured":"Taylor, MA, Jones, R. Risk of medication errors with infusion pumps: a study of 1,004 events from 132 hospitals across pennsylvania. Patient\u00a0Safety 2019;1. https:\/\/doi.org\/10.33940\/biomed\/2019.12.7.","DOI":"10.33940\/biomed\/2019.12.7"},{"key":"2023033113282394433_j_bmt-2022-0053_ref_003","unstructured":"Top 10 Health Technology Hazards for 2017 \u2013 A Report from Health Devices, November 2016. Available from: https:\/\/www.ecri.org\/Resources\/Whitepapers_and_reports\/Haz17.pdf."},{"key":"2023033113282394433_j_bmt-2022-0053_ref_004","unstructured":"Agres, Ted. FDA seeking safer infusion pumps. Pharm Pract News 2010;37:4."},{"key":"2023033113282394433_j_bmt-2022-0053_ref_005","unstructured":"American Nurse Today. High-alert drugs: strategies for safe I.V. infusions. Doylestown, Pennsylvania, US: American Nurse Journal; 2006."},{"key":"2023033113282394433_j_bmt-2022-0053_ref_006","doi-asserted-by":"crossref","unstructured":"Ma, H, Lovich, MA, Peterfreund, RA. Quantitative analysis of continuous intravenous infusions in pediatric anesthesia: safety implications of dead volume, flow rates, and fluid delivery. Paediatr Anaesth 2011;21:78\u201386. https:\/\/doi.org\/10.1111\/j.1460-9592.2010.03475.x.","DOI":"10.1111\/j.1460-9592.2010.03475.x"},{"key":"2023033113282394433_j_bmt-2022-0053_ref_007","doi-asserted-by":"crossref","unstructured":"Fonzo-Christe, C, Bochaton, N, Kiener, A, Rimensberger, P, Bonnabry, P. Incidence and causes of infusion and pediatric intensive care unit: a prospective pilot study. J Pediatr Pharmacol Therapeut 2020;25:500\u20136.","DOI":"10.5863\/1551-6776-25.6.500"},{"key":"2023033113282394433_j_bmt-2022-0053_ref_008","doi-asserted-by":"crossref","unstructured":"Lucas, P, Klein, S. Metrology for drug delivery. Biomed Tech 2015;60:271\u20135. https:\/\/doi.org\/10.1515\/bmt-2014-0155.","DOI":"10.1515\/bmt-2014-0155"},{"key":"2023033113282394433_j_bmt-2022-0053_ref_009","unstructured":"Niemann, A. Video on calibration of drug delivery devices; 2021. Available from: https:\/\/drugmetrology.com\/wp-content\/uploads\/2021\/12\/MeDDII_metrologyVideoHD.mp4."},{"key":"2023033113282394433_j_bmt-2022-0053_ref_010","doi-asserted-by":"crossref","unstructured":"Batista, E. New EMPIR project \u2013 metrology for drug delivery. Flow Meas Instrum 2020;72:101716. https:\/\/doi.org\/10.1016\/j.flowmeasinst.2020.101716.","DOI":"10.1016\/j.flowmeasinst.2020.101716"},{"key":"2023033113282394433_j_bmt-2022-0053_ref_011","doi-asserted-by":"crossref","unstructured":"Graham, E. Ultra-low flow rate measurement techniques. Measurement Sensors 2021;18. https:\/\/doi.org\/10.1016\/j.measen.2021.100279.","DOI":"10.1016\/j.measen.2021.100279"},{"key":"2023033113282394433_j_bmt-2022-0053_ref_012","doi-asserted-by":"crossref","unstructured":"Bissig, H. Primary standards for measuring flow rates from 100 nL\/min to 1 mL\/min \u2013 gravimetric principle. Biomed Tech 2015;60:301\u201316. https:\/\/doi.org\/10.1515\/bmt-2014-0145.","DOI":"10.1515\/bmt-2014-0145"},{"key":"2023033113282394433_j_bmt-2022-0053_ref_013","doi-asserted-by":"crossref","unstructured":"Tanaka, M. Recommended table for the density of water between 0 \u00b0C and 40 \u00b0C based on recent experimental reports. Metrologia 2001;38:301\u20139. https:\/\/doi.org\/10.1088\/0026-1394\/38\/4\/3.","DOI":"10.1088\/0026-1394\/38\/4\/3"},{"key":"2023033113282394433_j_bmt-2022-0053_ref_014","unstructured":"Benkov\u00e1, M, Schweitzer, F. New primary standard with piston prover for microflow of liquids. In: Proceedings of 18th International Flow Measurement Conference, FLOMEKO 2019. Lisabon: FLOMEKO; 2019."},{"key":"2023033113282394433_j_bmt-2022-0053_ref_015","unstructured":"JCGM 200:2012 - International vocabulary of metrology \u2013 Basic and general concepts and associated terms (VIM), 3rd ed. S\u00e8vres Cedex, France: Joint Committee for Guides in Metrology (JCGM); 2012."},{"key":"2023033113282394433_j_bmt-2022-0053_ref_016","unstructured":"IEC 60601-2-24, medical electrical equipment \u2013 part 2-24:2015\u00a0particular requirements for the basic safety and essential\u00a0performance of infusion pumps and controllers. Geneva, Switzerland: International Electrotechnical Commission [IEC]."},{"key":"2023033113282394433_j_bmt-2022-0053_ref_017","unstructured":"AAMI TIR101. fluid delivery performance testing for infusion pumps. Arlington, Virginia, US: Association for the Advancement of Medical Instrumentation [AAMI]; 2021."},{"key":"2023033113282394433_j_bmt-2022-0053_ref_018","unstructured":"ISO 7886-2:2020, sterile hypodermic syringes for single use \u2013 part 2: syringes for use with power-driven syringe pumps, 2020. Geneva, Switzerland: ISO\/TC 84."},{"key":"2023033113282394433_j_bmt-2022-0053_ref_019","doi-asserted-by":"crossref","unstructured":"Cox, MG. Evaluation of key comparison data. Metrologia 2002;39:589\u201395. https:\/\/doi.org\/10.1088\/0026-1394\/39\/6\/10.","DOI":"10.1088\/0026-1394\/39\/6\/10"}],"container-title":["Biomedical Engineering \/ Biomedizinische Technik"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/bmt-2022-0053\/xml","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/bmt-2022-0053\/pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,31]],"date-time":"2023-03-31T18:23:54Z","timestamp":1680287034000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.degruyter.com\/document\/doi\/10.1515\/bmt-2022-0053\/html"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,11,23]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12,16]]},"published-print":{"date-parts":[[2023,2,23]]}},"alternative-id":["10.1515\/bmt-2022-0053"],"URL":"https:\/\/doi.org\/10.1515\/bmt-2022-0053","relation":{},"ISSN":["0013-5585","1862-278X"],"issn-type":[{"value":"0013-5585","type":"print"},{"value":"1862-278X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,11,23]]}}}