{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,6]],"date-time":"2026-03-06T10:03:16Z","timestamp":1772791396895,"version":"3.50.1"},"reference-count":42,"publisher":"SAGE Publications","issue":"4","license":[{"start":{"date-parts":[[2002,12,1]],"date-time":"2002-12-01T00:00:00Z","timestamp":1038700800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Hum Factors"],"published-print":{"date-parts":[[2002,12]]},"abstract":"<jats:p> Acceptable limits derived from psychophysical methodologies have been proposed, measured, and employed in a range of applications. There is little existing work, however, on such limits for single-digit exertions and relatively limited evidence on several fundamental issues related to data collection and processing of a sequence of self-regulated exertion levels. An experimental study was conducted using 14 male and 10 female participants (age range 18--31 years) from whom maximal voluntary exertions and maximal acceptable limits (MALs) were obtained using the index finger and thumb. Moderate to high levels of consistency were found for both measures between sessions separated by one day. Single MAL values, determined from a time series of exertions, were equivalent across three divergent processing methods and between values obtained from 5- and 25-min samples. A critical interpretation of these and earlier results supports continued use of acceptable limits but also suggests that they should be used with some caution and not equated with safe limits. This research can be applied toward future development of exertion limits based on perceived acceptability. <\/jats:p>","DOI":"10.1518\/0018720024496908","type":"journal-article","created":{"date-parts":[[2005,7,20]],"date-time":"2005-07-20T12:03:03Z","timestamp":1121860983000},"page":"545-556","source":"Crossref","is-referenced-by-count":15,"title":["Determination and Evaluation of Acceptable Force Limits in Single-Digit Tasks"],"prefix":"10.1177","volume":"44","author":[{"given":"Maury A.","family":"Nussbaum","sequence":"first","affiliation":[{"name":"Virginia Polytechnic Institute and State University, Blacksburg, Virginia"}]},{"given":"Hope","family":"Johnson","sequence":"additional","affiliation":[{"name":"Virginia Polytechnic Institute and State University, Blacksburg, Virginia"}]}],"member":"179","published-online":{"date-parts":[[2002,12,1]]},"reference":[{"key":"atypb1","doi-asserted-by":"publisher","DOI":"10.1080\/15298667991430721"},{"key":"atypb2","doi-asserted-by":"publisher","DOI":"10.1177\/001872088002200301"},{"key":"atypb3","doi-asserted-by":"publisher","DOI":"10.1177\/001872088302500505"},{"key":"atypb4","doi-asserted-by":"publisher","DOI":"10.1080\/00140138608967222"},{"key":"atypb5","doi-asserted-by":"publisher","DOI":"10.1080\/00140139208967375"},{"key":"atypb6","doi-asserted-by":"publisher","DOI":"10.1177\/001872088302500502"},{"key":"atypb7","doi-asserted-by":"publisher","DOI":"10.1016\/S0169-8141(99)00005-0"},{"key":"atypb8","unstructured":"Fernandez, J. E., Fredericks, T. K. & Marley, R. J. (1995). The psychophysical approach in upper extremities work. In Contemporary Ergonomics: Proceedings of the Ergonomics Society's Annual Conference (pp. 456\u2013461). Leicestershire, England: Ergonomics Society."},{"key":"atypb9","doi-asserted-by":"publisher","DOI":"10.1080\/00140138408963609"},{"key":"atypb10","doi-asserted-by":"publisher","DOI":"10.1016\/0003-6870(87)90139-6"},{"key":"atypb11","doi-asserted-by":"publisher","DOI":"10.1177\/001872088002200408"},{"key":"atypb12","doi-asserted-by":"publisher","DOI":"10.1080\/00140138608967200"},{"key":"atypb13","doi-asserted-by":"publisher","DOI":"10.1080\/00140139408964915"},{"key":"atypb14","first-page":"272","volume":"14","author":"Garg, A.","year":"1982","journal-title":"IIE Transactions"},{"key":"atypb15","doi-asserted-by":"publisher","DOI":"10.1080\/00140138408963492"},{"key":"atypb16","doi-asserted-by":"publisher","DOI":"10.1080\/15298668691389829"},{"key":"atypb17","doi-asserted-by":"publisher","DOI":"10.1177\/001872088602800607"},{"key":"atypb18","doi-asserted-by":"crossref","unstructured":"Jones, L. A. (1998). Perception and control of finger forces. In R. J. Furness (Eds.), Proceedings of the ASME Dynamic Systems and Control Division (DSC Vol. 64, pp. 133\u2013137). New York: ASME International.","DOI":"10.1115\/IMECE1998-0244"},{"key":"atypb19","doi-asserted-by":"publisher","DOI":"10.1177\/001872089303500207"},{"key":"atypb20","doi-asserted-by":"crossref","unstructured":"Karwowski, W. (1996). Maximum safe weights of lift: A new paradigm for setting design limits in manual lifting tasks based on the psychophysical approach. In Proceedings of the Human Factors and Ergonomics Society 40th Annual Meeting (pp. 614\u2013618). Santa Monica, CA: Human Factors and Ergonomics Society.","DOI":"10.1177\/154193129604001307"},{"key":"atypb21","doi-asserted-by":"publisher","DOI":"10.1080\/001401399185793"},{"key":"atypb22","doi-asserted-by":"publisher","DOI":"10.1080\/00140138608968262"},{"key":"atypb23","doi-asserted-by":"publisher","DOI":"10.1080\/00140138108924913"},{"key":"atypb24","doi-asserted-by":"publisher","DOI":"10.1080\/00140138208925031"},{"key":"atypb25","doi-asserted-by":"publisher","DOI":"10.1016\/0169-8141(94)90064-7"},{"key":"atypb26","doi-asserted-by":"publisher","DOI":"10.1177\/001872088302500503"},{"key":"atypb27","doi-asserted-by":"publisher","DOI":"10.1080\/00140138408963595"},{"key":"atypb28","doi-asserted-by":"publisher","DOI":"10.1016\/0003-6870(83)90004-2"},{"key":"atypb29","doi-asserted-by":"publisher","DOI":"10.1080\/00140138808966663"},{"key":"atypb30","doi-asserted-by":"publisher","DOI":"10.1080\/00140138908966879"},{"key":"atypb31","doi-asserted-by":"publisher","DOI":"10.1016\/S0169-8141(00)00031-7"},{"key":"atypb32","doi-asserted-by":"publisher","DOI":"10.1016\/0169-8141(93)90051-E"},{"key":"atypb33","first-page":"49","volume-title":"Repetitive motion disorders of the upper extremity","author":"Putz-Anderson, V.","year":"1994"},{"key":"atypb34","doi-asserted-by":"publisher","DOI":"10.1080\/00140138508963140"},{"key":"atypb35","doi-asserted-by":"publisher","DOI":"10.1097\/00043764-197807000-00009"},{"key":"atypb36","doi-asserted-by":"publisher","DOI":"10.1016\/S0169-8141(98)00064-X"},{"key":"atypb37","doi-asserted-by":"publisher","DOI":"10.1080\/00028896709342530"},{"key":"atypb38","doi-asserted-by":"publisher","DOI":"10.1080\/00028896809343050"},{"key":"atypb39","doi-asserted-by":"publisher","DOI":"10.1080\/00140139508925204"},{"key":"atypb40","doi-asserted-by":"crossref","first-page":"645","DOI":"10.1097\/00007632-198709000-00003","volume":"12","author":"Troup, J. D. G.","year":"1987","journal-title":"Spine"},{"key":"atypb41","doi-asserted-by":"publisher","DOI":"10.1016\/0003-6870(96)00006-3"},{"key":"atypb42","doi-asserted-by":"publisher","DOI":"10.1016\/0003-6870(93)90459-M"}],"container-title":["Human Factors: The Journal of the Human Factors and Ergonomics Society"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1518\/0018720024496908","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1518\/0018720024496908","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,11]],"date-time":"2025-03-11T05:35:45Z","timestamp":1741671345000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1518\/0018720024496908"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2002,12]]},"references-count":42,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2002,12]]}},"alternative-id":["10.1518\/0018720024496908"],"URL":"https:\/\/doi.org\/10.1518\/0018720024496908","relation":{},"ISSN":["0018-7208","1547-8181"],"issn-type":[{"value":"0018-7208","type":"print"},{"value":"1547-8181","type":"electronic"}],"subject":[],"published":{"date-parts":[[2002,12]]}}}