{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T21:02:55Z","timestamp":1777669375935,"version":"3.51.4"},"reference-count":58,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2006,3,1]],"date-time":"2006-03-01T00:00:00Z","timestamp":1141171200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Hum Factors"],"published-print":{"date-parts":[[2006,3]]},"abstract":"<jats:p>Objectives: The objectives were to measure the impact of specific features of imaging devices on tasks relevant to minimally invasive surgery (MIS) and to investigate cognitive and perceptual factors in such tasks. Background: Although image-guided interventions used in MIS provide benefits for patients, they pose drawbacks for surgeons, including degraded depth perception and reduced field of view (FOV). It is important to identify design factors that affect performance. Method: In two navigation experiments, observers fed a borescope through an object until it reached a target. Task completion time and object shape judgments were measured. In a motion perception experiment, observers reported the direction of a line that moved behind an aperture. A motion illusion associated with reduced FOV was measured. Results: Navigation through an object was faster when a preview of the object's exterior was provided. Judgments about the object's shape were more accurate with a preview (compared with none) and with active viewing (compared with passive viewing). The motion illusion decreased with a rectangular or rotating octagonal viewing aperture (compared with circular). Conclusions: Navigation performance may be enhanced when surgeons develop a mental model of the surgical environment, when surgeons (rather than assistants) control the camera, and when the shape of the image is designed to reduce visual illusions. Application: Unintentional contact between surgical tools and healthy tissues may be reduced during MIS when (a) visual aids permit surgeons to maintain a mental model of the surgical environment, (b) images are bound by noncircular apertures, and (c) surgeons manually control the camera.<\/jats:p>","DOI":"10.1518\/001872006776412162","type":"journal-article","created":{"date-parts":[[2006,4,3]],"date-time":"2006-04-03T17:14:38Z","timestamp":1144084478000},"page":"23-38","source":"Crossref","is-referenced-by-count":22,"title":["Toward the Improvement of Image-Guided Interventions for Minimally Invasive Surgery: Three Factors That Affect Performance"],"prefix":"10.1177","volume":"48","author":[{"given":"Patricia R.","family":"DeLucia","sequence":"first","affiliation":[{"name":"Texas Tech University, Lubbock, Texas"}]},{"given":"Robert D.","family":"Mather","sequence":"additional","affiliation":[{"name":"Texas Tech University, Lubbock, Texas"}]},{"given":"John A.","family":"Griswold","sequence":"additional","affiliation":[{"name":"Texas Tech University Health Sciences Center, Lubbock, Texas"}]},{"given":"Sunanda","family":"Mitra","sequence":"additional","affiliation":[{"name":"Texas Tech University, Lubbock, Texas"}]}],"member":"179","published-online":{"date-parts":[[2006,3,1]]},"reference":[{"key":"atypb1","doi-asserted-by":"publisher","DOI":"10.1097\/00006123-199809000-00072"},{"key":"atypb2","doi-asserted-by":"publisher","DOI":"10.1055\/s-2007-1010697"},{"key":"atypb3","volume-title":"Visual perception: Physiology, psychology, and ecology","author":"Bruce, V.","year":"1996","edition":"3"},{"key":"atypb4","doi-asserted-by":"crossref","unstructured":"Cao, C. G. L. (2001). Designing for spatial orientation in endoscopic environments. In Proceedings of the Human Factors and Ergonomics Society 45th Annual Meeting (pp. 1259\u20131263). Santa Monica, CA: Human Factors and Ergonomics Society.","DOI":"10.1177\/154193120104501701"},{"key":"atypb5","doi-asserted-by":"crossref","unstructured":"Cao, C. G. L. & Milgram, P. (2000). Disorientation in minimal access surgery: A case study. In Proceedings of the XIVth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Society (pp. 4.169\u20134.172). Santa Monica, CA: Human Factors and Ergonomics Society.","DOI":"10.1177\/154193120004402610"},{"key":"atypb6","doi-asserted-by":"publisher","DOI":"10.1007\/s004649900385"},{"key":"atypb7","doi-asserted-by":"publisher","DOI":"10.1007\/s004649900795"},{"key":"atypb8","volume-title":"Endoscopy of the colon, rectum, and anus.","author":"Church, J. M.","year":"1995"},{"key":"atypb9","doi-asserted-by":"publisher","DOI":"10.1068\/p260287"},{"key":"atypb10","volume-title":"Sensation and perception","author":"Coren, S.","year":"1999","edition":"5"},{"key":"atypb11","volume-title":"Practical gastrointestinal endoscopy","author":"Cotton, P. B.","year":"1996","edition":"4"},{"key":"atypb12","doi-asserted-by":"crossref","unstructured":"DeLucia, P. R., Hoskins, M. L. & Griswold, J. A. (2004). Laparoscopic surgery: Are multiple viewing perspectives better than one? In Proceedings of the Human Factors and Ergonomics Society 48th Annual Meeting (pp. 1661\u20131664). Santa Monica, CA: Human Factors and Ergonomics Society.","DOI":"10.1177\/154193120404801507"},{"key":"atypb13","doi-asserted-by":"publisher","DOI":"10.1207\/s15327108ijap0504_3"},{"key":"atypb14","first-page":"121","volume-title":"Cybersurgery: Advanced technologies for surgical practice","author":"Digioia, A. M.","year":"1998"},{"key":"atypb15","volume-title":"Living in a world transformed: Perceptual and performatory adaptation to visual distortion.","author":"Dolezal, H.","year":"1982"},{"key":"atypb16","unstructured":"Ellis, S. R. & Grunwald, A. (1989). Head-mounted spatial instruments: II. Synthetic reality or impossible dream (Vol. 3, pp. 521\u2013532). In Proceedings of the NASA Conference on Space Telerobotics. Moffett Field, CA: NASA-Ames Research Center."},{"key":"atypb17","doi-asserted-by":"publisher","DOI":"10.1002\/mrm.1910390215"},{"key":"atypb18","first-page":"146","volume-title":"Medicine meets virtual reality: Vol. 81. Studies in health technology and informatics","author":"Eyal, R.","year":"2001"},{"key":"atypb19","doi-asserted-by":"publisher","DOI":"10.1207\/s15326969eco0202_1"},{"key":"atypb20","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-002-8569-4"},{"key":"atypb21","doi-asserted-by":"publisher","DOI":"10.1007\/s00464-003-8176-z"},{"key":"atypb22","doi-asserted-by":"publisher","DOI":"10.1007\/s00268-001-0133-1"},{"key":"atypb23","doi-asserted-by":"publisher","DOI":"10.1037\/h0046962"},{"key":"atypb24","first-page":"171","volume-title":"Medicine meets virtual reality: Vol. 81. Studies in health technology and informatics","author":"Haluck, R. S.","year":"2001"},{"key":"atypb25","doi-asserted-by":"publisher","DOI":"10.1016\/S0960-9822(00)80053-6"},{"key":"atypb26","volume-title":"Perception","author":"Hochberg, J. E.","year":"1978","edition":"2"},{"key":"atypb27","doi-asserted-by":"publisher","DOI":"10.1007\/s004649900920"},{"key":"atypb28","doi-asserted-by":"publisher","DOI":"10.1177\/001872089203400402"},{"key":"atypb29","volume-title":"To err is human: Building a safer health system.","author":"Kohn, L. T.","year":"2000"},{"key":"atypb30","doi-asserted-by":"publisher","DOI":"10.1097\/00006123-199809000-00075"},{"key":"atypb31","doi-asserted-by":"publisher","DOI":"10.1097\/00006123-199808000-00141"},{"key":"atypb32","doi-asserted-by":"crossref","unstructured":"MacKenzie, C. L. & Ibbotson, J. A. (2000). Survey of surgeons' use, assessment and look-ahead of endoscopic surgical technologies. In Proceedings of the XIVth Triennial Congress of the International Ergonomics Association and 44th Annual Meeting of the Human Factors and Ergonomics Society (pp. 4.165-\u20134.168). Santa Monica, CA: Human Factors and Ergonomics Society.","DOI":"10.1177\/154193120004402609"},{"key":"atypb33","doi-asserted-by":"publisher","DOI":"10.1089\/end.1996.10.371"},{"key":"atypb34","doi-asserted-by":"publisher","DOI":"10.1177\/001872088602800406"},{"key":"atypb35","doi-asserted-by":"publisher","DOI":"10.1109\/VBC.1990.109348"},{"key":"atypb36","doi-asserted-by":"publisher","DOI":"10.1080\/10255840008907997"},{"key":"atypb37","volume-title":"Human factors in simple and complex systems.","author":"Proctor, R. W.","year":"1994"},{"key":"atypb38","first-page":"1","volume":"12","author":"Rachlin, J. A.","year":"1995","journal-title":"Food and Drug Administration User Facility Reporting"},{"key":"atypb39","volume-title":"Do it by design: An introduction to human factors in medical devices.","author":"Sawyer, D.","year":"1997"},{"key":"atypb40","doi-asserted-by":"publisher","DOI":"10.1002\/0471214426.pas0104"},{"key":"atypb41","doi-asserted-by":"publisher","DOI":"10.1097\/00000658-200210000-00008"},{"key":"atypb42","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(89)90047-3"},{"key":"atypb43","doi-asserted-by":"publisher","DOI":"10.2466\/pms.1989.68.1.243"},{"key":"atypb44","doi-asserted-by":"publisher","DOI":"10.2214\/ajr.168.5.9129406"},{"key":"atypb45","first-page":"124","volume-title":"Medicine meets virtual reality","author":"Taffinder, N.","year":"1998"},{"key":"atypb46","doi-asserted-by":"publisher","DOI":"10.3109\/10929089709149080"},{"key":"atypb47","doi-asserted-by":"publisher","DOI":"10.1109\/IEMBS.1997.756904"},{"key":"atypb48","doi-asserted-by":"publisher","DOI":"10.1162\/105474600566772"},{"key":"atypb49","doi-asserted-by":"publisher","DOI":"10.1162\/pres.1993.2.1.66"},{"key":"atypb50","first-page":"488","volume-title":"Endoscopic surgery","author":"Treat, M. R.","year":"1994"},{"key":"atypb51","doi-asserted-by":"publisher","DOI":"10.3122\/jabfm.11.6.426"},{"key":"atypb52","volume-title":"Human factors points to consider for IDE devices.","author":"U.S. Food and Drug Administration Center for Devices and Radiological Health.","year":"1997"},{"key":"atypb53","volume-title":"Device use safety: Incorporating human factors in risk management.","author":"U.S. Food and Drug Administration Center for Devices and Radiological Health.","year":"1999"},{"key":"atypb54","doi-asserted-by":"publisher","DOI":"10.1016\/S0039-6060(03)00248-4"},{"key":"atypb55","doi-asserted-by":"crossref","unstructured":"Wickens, C. D. (1999). Frames of reference for navigation. In International Symposium on Attention and Performance (Ed.), Attention and performance XVII: Cognitive regulation of performance, interaction of theory and application (pp. 113\u2013144). Cambridge, MA: MIT Press.","DOI":"10.7551\/mitpress\/1480.003.0010"},{"key":"atypb56","doi-asserted-by":"publisher","DOI":"10.1177\/001872088803000505"},{"key":"atypb57","doi-asserted-by":"publisher","DOI":"10.1016\/0140-6736(93)90489-4"},{"key":"atypb58","unstructured":"Woods, D. (2000, September).\n                      Human factors research to improve patient safety\n                      [Oral testimony at the National Summit on Medical Errors and Patient Safety Research]. Retrieved January 5, 2006, from the American Psychological Association Public Policy Office Web site: http:\/\/www.apa.org\/ppo\/issues\/shumfactors.html"}],"container-title":["Human Factors: The Journal of the Human Factors and Ergonomics Society"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1518\/001872006776412162","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1518\/001872006776412162","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T07:52:56Z","timestamp":1777449176000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1518\/001872006776412162"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,3]]},"references-count":58,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2006,3]]}},"alternative-id":["10.1518\/001872006776412162"],"URL":"https:\/\/doi.org\/10.1518\/001872006776412162","relation":{},"ISSN":["0018-7208","1547-8181"],"issn-type":[{"value":"0018-7208","type":"print"},{"value":"1547-8181","type":"electronic"}],"subject":[],"published":{"date-parts":[[2006,3]]}}}