{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,3,11]],"date-time":"2025-03-11T04:37:29Z","timestamp":1741667849542,"version":"3.38.0"},"reference-count":38,"publisher":"SAGE Publications","issue":"3","license":[{"start":{"date-parts":[[1996,9,1]],"date-time":"1996-09-01T00:00:00Z","timestamp":841536000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Hum Factors"],"published-print":{"date-parts":[[1996,9]]},"abstract":"<jats:p> A sequential or RAP COM (rapid communication) display was compared with a more conventional spatial display as participants monitored dynamically changing sets of three-digit numbers and responded to occasional target stimuli. In an effort to equate the stimulus-response compatibility of the two displays, we had participants respond to the targets with a chord keyboard in Experiment 1 and vocally in Experiment 2. We examined the influence of display duration on performance with the RAP COM and spatial formats by presenting stimuli at three different durations (400, 800, and 1200 ms). The influence of practice on performance with the RAP COM and spatial displays was also investigated. Participants responded to targets more quickly in the RAP COM than in the spatial displays at each of the three presentation durations and across more than 2000 trials of practice. Accuracy was influenced by the display presentation duration. Accuracy was higher for the RAP COM than for the spatial display at the 800-ms stimulus presentation duration in Experiment 1 and at the 800- and 1200-ms presentation durations in Experiment 2. The results are discussed in terms of the potential utility of RAP COM displays for complex, real-world systems. <\/jats:p>","DOI":"10.1518\/001872096778702015","type":"journal-article","created":{"date-parts":[[2006,10,24]],"date-time":"2006-10-24T14:06:29Z","timestamp":1161698789000},"page":"464-483","source":"Crossref","is-referenced-by-count":3,"title":["A Comparison of Sequential and Spatial Displays in a Complex Monitoring Task"],"prefix":"10.1177","volume":"38","author":[{"given":"Christopher M.","family":"Konrad","sequence":"first","affiliation":[{"name":"University of Illinois at Urbana-Champaign, Urbana, Illinois"}]},{"given":"Arthur F.","family":"Kramer","sequence":"additional","affiliation":[{"name":"University of Illinois at Urbana-Champaign, Urbana, Illinois"}]},{"given":"Stephen E.","family":"Watson","sequence":"additional","affiliation":[{"name":"University of Illinois at Urbana-Champaign, Urbana, Illinois"}]},{"given":"Timothy A.","family":"Weber","sequence":"additional","affiliation":[{"name":"University of Illinois at Urbana-Champaign, Urbana, Illinois"}]}],"member":"179","published-online":{"date-parts":[[1996,9,1]]},"reference":[{"key":"atypb1","first-page":"155","volume":"194","author":"Bourne, L. E.","year":"1986","journal-title":"Zeitschrift fur Psychologie,"},{"key":"atypb2","doi-asserted-by":"publisher","DOI":"10.3758\/BF03210498"},{"key":"atypb3","doi-asserted-by":"publisher","DOI":"10.1016\/0042-6989(74)90077-7"},{"key":"atypb4","doi-asserted-by":"publisher","DOI":"10.3758\/BF03197693"},{"key":"atypb5","doi-asserted-by":"publisher","DOI":"10.3758\/BF03198304"},{"key":"atypb6","doi-asserted-by":"publisher","DOI":"10.1037\/h0062827"},{"key":"atypb7","doi-asserted-by":"publisher","DOI":"10.3758\/BF03210208"},{"key":"atypb8","doi-asserted-by":"publisher","DOI":"10.1109\/21.17378"},{"key":"atypb9","doi-asserted-by":"publisher","DOI":"10.1016\/0001-6918(85)90051-4"},{"key":"atypb10","doi-asserted-by":"publisher","DOI":"10.1037\/0096-1523.11.4.431"},{"key":"atypb11","first-page":"98","volume":"15","author":"Intraub, H.","year":"1989","journal-title":"Journal of Experimental Psychology: Human Perception and Performance,"},{"key":"atypb12","doi-asserted-by":"crossref","unstructured":"Joseph, K. M. & Uhlarik, J. (1992). The effects of legibility and display size on performance for RAP COM and spatial display formats. In Proceeding of the Human Factors Society 36th Annual Meeting (pp. 1388\u20131391). Santa Monica, CA: Human Factors and Ergonomics Society.","DOI":"10.1177\/154193129203601806"},{"key":"atypb13","doi-asserted-by":"publisher","DOI":"10.1002\/acp.2350020108"},{"key":"atypb14","doi-asserted-by":"publisher","DOI":"10.1016\/B978-0-444-70113-8.50071-0"},{"key":"atypb15","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1037\/0096-3445.111.2.208","volume":"111","author":"Juola, J. F.","year":"1982","journal-title":"Journal of Experimental Psychology: Human Perception and Performance,"},{"key":"atypb16","doi-asserted-by":"publisher","DOI":"10.1037\/0096-3445.111.2.228"},{"key":"atypb17","doi-asserted-by":"publisher","DOI":"10.1016\/S0166-4115(08)61231-5"},{"key":"atypb18","doi-asserted-by":"publisher","DOI":"10.1016\/0010-0277(87)90016-3"},{"key":"atypb19","doi-asserted-by":"publisher","DOI":"10.3758\/BF03197061"},{"key":"atypb20","doi-asserted-by":"publisher","DOI":"10.1037\/0096-1523.16.1.30"},{"key":"atypb21","doi-asserted-by":"publisher","DOI":"10.1080\/00140136208930601"},{"key":"atypb22","doi-asserted-by":"publisher","DOI":"10.1016\/0749-596X(86)90013-6"},{"key":"atypb23","doi-asserted-by":"publisher","DOI":"10.1177\/001872088803000205"},{"key":"atypb24","doi-asserted-by":"crossref","unstructured":"Matin, E., Boff, K. & Donovan, R. (1987). Raising control\/display efficiency with rapid communication display technology. In Proceedings of the Human Factors Society 31st Annual Meeting (pp. 258\u2013262). Santa Monica, CA: Human Factors and Ergonomics Society.","DOI":"10.1177\/154193128703100227"},{"key":"atypb25","doi-asserted-by":"publisher","DOI":"10.1080\/14640748308402123"},{"key":"atypb26","doi-asserted-by":"crossref","unstructured":"Osgood, S. S., Boff, K. R. & Donovan, R. S. (1988). Rapid communication display technology efficiency in a multitask environment. In Proceedings of the Human Factors Society 32nd Annual Meeting (pp. 1395\u20131399). Santa Monica, CA: Human Factors and Ergonomics Society.","DOI":"10.1177\/154193128803201919"},{"key":"atypb27","doi-asserted-by":"publisher","DOI":"10.1177\/001872089103300406"},{"key":"atypb28","first-page":"395","volume-title":"Attention and performance VIII","author":"Potter, M. C","year":"1980"},{"key":"atypb29","doi-asserted-by":"crossref","unstructured":"Raij, D., Gopher, D. & Kimchi, R. (1987). Perceptual and motor determinants of efficient data entry. In Proceedings of the Human Factors Society 31st Annual Meeting (pp. 820\u2013824). Santa Monica, CA: Human Factors and Ergonomics Society.","DOI":"10.1177\/154193128703100730"},{"volume-title":"An investigation of the relationship between eye movements and comprehension in fluent reading.","year":"1974","author":"Raygor, R.","key":"atypb30"},{"key":"atypb31","doi-asserted-by":"publisher","DOI":"10.1037\/0096-1523.18.3.849"},{"key":"atypb32","doi-asserted-by":"publisher","DOI":"10.1016\/0010-0285(80)90005-5"},{"key":"atypb33","doi-asserted-by":"publisher","DOI":"10.1016\/0010-0285(82)90006-8"},{"key":"atypb34","doi-asserted-by":"publisher","DOI":"10.1037\/0096-1523.12.1.3"},{"key":"atypb35","doi-asserted-by":"crossref","unstructured":"Uhlarik, J. & Joseph, K. M. (1992). Spatial and temporal (RAP COM) visual display formats and the proximity compatibility principle. In Proceedings of the Human Factors Society 36th Annual Meeting (pp. 1383\u20131387). Santa Monica, CA: Human Factors and Ergonomics Society.","DOI":"10.1177\/154193129203601805"},{"key":"atypb36","doi-asserted-by":"crossref","unstructured":"Uhlarik, J., Joseph, K. M. & Renfro, M. D. (1991). Effects of concurrent information load on serial and simultaneous visual display formats. In Proceedings of the Human Factors Society 35th Annual Meeting (pp. 1527\u20131531). Santa Monica, CA: Human Factors and Ergonomics Society.","DOI":"10.1177\/154193129103502023"},{"key":"atypb37","doi-asserted-by":"publisher","DOI":"10.1037\/0096-3445.111.2.239"},{"key":"atypb38","doi-asserted-by":"publisher","DOI":"10.3758\/BF03202369"}],"container-title":["Human Factors: The Journal of the Human Factors and Ergonomics Society"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1518\/001872096778702015","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1518\/001872096778702015","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,10]],"date-time":"2025-03-10T23:00:50Z","timestamp":1741647650000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.1518\/001872096778702015"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[1996,9]]},"references-count":38,"journal-issue":{"issue":"3","published-print":{"date-parts":[[1996,9]]}},"alternative-id":["10.1518\/001872096778702015"],"URL":"https:\/\/doi.org\/10.1518\/001872096778702015","relation":{},"ISSN":["0018-7208","1547-8181"],"issn-type":[{"type":"print","value":"0018-7208"},{"type":"electronic","value":"1547-8181"}],"subject":[],"published":{"date-parts":[[1996,9]]}}}