{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,19]],"date-time":"2025-11-19T02:21:44Z","timestamp":1763518904075,"version":"3.45.0"},"reference-count":16,"publisher":"ASTM International100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959","isbn-type":[{"type":"print","value":"0803134126"},{"type":"print","value":"9780803134126"},{"type":"electronic","value":"9780803162426"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2007,1,1]]},"abstract":"<jats:p>Paired thermoluminescence dosimeters and ionization chambers were used for characterizing mixed (neutron and photon) radiation fields at the LR-0, a zero power model of VVER reactors. Detector responses were investigated in standard photon and thermal neutron fields. A good agreement was obtained among the doses measured with the two methods. Furthermore, the measured photon and neutron attenuation values are consistent with those from evaluated, independent data.<\/jats:p>","DOI":"10.1520\/stp45438s","type":"book-chapter","created":{"date-parts":[[2009,9,14]],"date-time":"2009-09-14T16:42:14Z","timestamp":1252946534000},"page":"151-159","source":"Crossref","is-referenced-by-count":1,"title":["Neutron and Photon Dosimetry at the LR-0 Reactor Using Paired Detectors"],"prefix":"10.1520","author":[{"given":"Ana C.","family":"Fernandes","sequence":"first","affiliation":[{"name":"Reactor Sector, Nuclear and Technological Institute 1 Postdoctoral Fellow and Auxiliary Researcher , respectively, , Estrada National 10, P-2686-953 Sacav\u00e9m\u2014Portugal and Members of the University of Lisbon Nuclear Physics Centre, Av. Prof. Gama Pinto, 2, P-1649-003Lisbon, Portugal ."}]},{"given":"Ev\u017een","family":"Nov\u00e1k","sequence":"additional","affiliation":[{"name":"Nuclear Research Institute \u0158e\u017e plc 2 Engineer and Senior Researcher , respectively, Nuclear Power and Safety Division, , Husinec \u0158e\u017e 130, 250-68\u0158e\u017e u. Prahy \u2014 Czech Republic ."}]},{"given":"Jo\u00e3o","family":"Cardoso","sequence":"additional","affiliation":[{"name":"Nuclear and Technological Institute 3 Laboratory Head and Technician , respectively, Department of Radiological Protection and Nuclear Safety, , Estrada Nacional 10, P-2686-953Sacav\u00e9m \u2014 Portugal ."}]},{"given":"Luis","family":"Santos","sequence":"additional","affiliation":[{"name":"Nuclear and Technological Institute 3 Laboratory Head and Technician , respectively, Department of Radiological Protection and Nuclear Safety, , Estrada Nacional 10, P-2686-953Sacav\u00e9m \u2014 Portugal ."}]},{"given":"Jos\u00e9 G.","family":"Marques","sequence":"additional","affiliation":[{"name":"Reactor Sector, Nuclear and Technological Institute 1 Postdoctoral Fellow and Auxiliary Researcher , respectively, , Estrada National 10, P-2686-953 Sacav\u00e9m\u2014Portugal and Members of the University of Lisbon Nuclear Physics Centre, Av. Prof. Gama Pinto, 2, P-1649-003Lisbon, Portugal ."}]},{"given":"Vojt\u0115ch","family":"R\u00fdpar","sequence":"additional","affiliation":[{"name":"Nuclear Research Institute \u0158e\u017e plc 2 Engineer and Senior Researcher , respectively, Nuclear Power and Safety Division, , Husinec \u0158e\u017e 130, 250-68\u0158e\u017e u. Prahy \u2014 Czech Republic ."}]}],"member":"381","reference":[{"article-title":"WWER-1000 Mock-up Experiment","year":"2002","author":"O\u0161mera","key":"2025111821165412200_p151_c1"},{"article-title":"The Results of Photon Spectra Measurements Over the Reactor Pressure Vessel Simulator in WWER-100 Model in the LR-0 Experimental Reactor","year":"2004","author":"O\u0161mera","key":"2025111821165412200_p151_c2"},{"key":"2025111821165412200_p151_c3","unstructured":"Clinical Neutron Dosimetry Part 1: Determination of Absorbed Dose in a Patient Treated by External Beams of Fast Neutrons, ICRU Report 45, International Commission on Radiation Units and Measurements, Bethesda, MD, 1989."},{"key":"2025111821165412200_p151_c4","doi-asserted-by":"crossref","DOI":"10.1118\/1.597737","article-title":"The Neutron Sensitivity of Dosimeters Applied to Boron Neutron Capture Therapy","volume":"23","author":"Raaijmakers","year":"1996","journal-title":"Med. Phys.","ISSN":"https:\/\/id.crossref.org\/issn\/0094-2405","issn-type":"print"},{"issue":"3","key":"2025111821165412200_p151_c5","doi-asserted-by":"crossref","DOI":"10.1093\/oxfordjournals.rpd.a032585","article-title":"Twin Ionisation Chambers for Dose Determinations in Phantom in an Epithermal Neutron Beam","volume":"81","author":"Kosunen","year":"1999","journal-title":"Radiat. Prot. Dosim.","ISSN":"https:\/\/id.crossref.org\/issn\/0144-8420","issn-type":"print"},{"issue":"12","key":"2025111821165412200_p151_c6","article-title":"Characteristics of Mg\/Ar Ionisation Chambers Used as Gamma-Ray Dosemeters in Mixed Neutron-Photon Fields","volume":"3","author":"Zoetlief","year":"1986","journal-title":"Phys. Med. Biol.","ISSN":"https:\/\/id.crossref.org\/issn\/0031-9155","issn-type":"print"},{"issue":"4","key":"2025111821165412200_p151_c7","doi-asserted-by":"publisher","DOI":"10.1088\/0031-9155\/24\/4\/004","article-title":"Energy Dependence of the Neutron Sensitivity of C-CO2, Mg-Ar and TE-TE Ionisation Chambers","volume":"24","author":"Waterman","year":"1979","journal-title":"Phys. Med. Biol.","ISSN":"https:\/\/id.crossref.org\/issn\/0031-9155","issn-type":"print"},{"key":"2025111821165412200_p151_c8","unstructured":"Absorbed Dose Determination in Photon and Electron Beams, Technical Reports Series No. 277, International Atomic Energy Agency, Vienna, 1987."},{"key":"2025111821165412200_p151_c9","article-title":"Neutron Dosimetry","volume-title":"Thermoluminescence and Thermoluminescent Dosimetry Vol. II","author":"Horowitz","year":"1984"},{"issue":"1\u20134","key":"2025111821165412200_p151_c10","article-title":"Neutron Response of LiF TL Detectors","volume":"44","author":"Hahn","year":"1992","journal-title":"Radiat. Prot. Dosim.","ISSN":"https:\/\/id.crossref.org\/issn\/0144-8420","issn-type":"print"},{"key":"2025111821165412200_p151_c11","doi-asserted-by":"crossref","DOI":"10.1007\/978-94-011-2781-3_61","article-title":"Assessment of the Fast Neutron Sensitivity of Thermoluminescent Gamma Dosimeters","volume-title":"Proc. 7th ASTM Symp. Reactor Dosimetry, Strasbourg, 1990","author":"A\u00eft Abderrahim","year":"1992"},{"issue":"1\u20134","key":"2025111821165412200_p151_c12","article-title":"Thermoluminescence Response of 6LiF (Mg,Cu,P) and 6LiF (Mg,Cu,P) TL Chips in Neutron and Gamma Ray Mixed Fields","volume":"33","author":"Wang","year":"1990","journal-title":"Radiat. Prot. Dosim.","ISSN":"https:\/\/id.crossref.org\/issn\/0144-8420","issn-type":"print"},{"key":"2025111821165412200_p151_c13","unstructured":"Photon, Electron, Proton and Neutron Interaction Data for Body Tissues, Report 46, International Commission on Radiation Units and Measurements, Bethesda, MD, 1992."},{"key":"2025111821165412200_p151_c14","doi-asserted-by":"crossref","DOI":"10.1007\/978-94-011-2781-3_27","article-title":"PC Programs for the Conversion of Neutron Spectra and Cross Sections Between Different Group and Point Representations","volume-title":"Proc. 7th ASTM Symp. Reactor Dosimetry, Strasbourg, 1990","author":"Ser\u00e9n","year":"1992"},{"key":"2025111821165412200_p151_c15","unstructured":"Stallmann, F. W., \u201cLSL-M2: A Computer Program for Least-Squares Logarithmic Adjustment of Neutron Spectra,\u201d NUREG\/CR-4349, ORNL\/TM-9933, Oak Ridge National Laboratory, 1986."},{"key":"2025111821165412200_p151_c16","article-title":"The Gamma Ray Spectra Measurement in Reactor Pressure Vessel Simulator in WWER-1000 Engineering Benchmark","volume-title":"Proc. 11th Intl. Symp. Reactor Dosimetry, Brussels, 2002","author":"Osmera","year":"2003"}],"container-title":["Reactor Dosimetry: 12th International Symposium"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/dl.astm.org\/stps\/book\/chapter-pdf\/214289\/10_1520_stp45438s.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,19]],"date-time":"2025-11-19T02:17:21Z","timestamp":1763518641000},"score":1,"resource":{"primary":{"URL":"https:\/\/dl.astm.org\/stps\/book\/1787\/chapter\/644478\/Neutron-and-Photon-Dosimetry-at-the-LR-0-Reactor"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,1,1]]},"ISBN":["0803134126","9780803134126","9780803162426"],"references-count":16,"URL":"https:\/\/doi.org\/10.1520\/stp45438s","relation":{},"subject":[],"published":{"date-parts":[[2007,1,1]]}}}