{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,2]],"date-time":"2026-05-02T13:48:50Z","timestamp":1777729730900,"version":"3.51.4"},"reference-count":25,"publisher":"SAGE Publications","issue":"6","license":[{"start":{"date-parts":[[2014,1,1]],"date-time":"2014-01-01T00:00:00Z","timestamp":1388534400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Interv Neuroradiol"],"published-print":{"date-parts":[[2014,11]]},"abstract":"<jats:p>Endovascular treatment of wide-neck bifurcation aneurysms is challenging and often requires adjunctive techniques and devices. We report our experience with the hybrid Y stenting with the waffle-cone technique, combining Y stent-assisted coiling and waffle-cone stenting techniques. This approach has been described only in a single case report using a combination of open and closed cell stents. We describe four cases treated by hybrid Y stenting with the waffle-cone procedure with a variation from the originally reported technique, consisting in deploying two closed cell stents. All patients were successfully treated without complications. We propose hybrid Y stenting with the waffle-cone for the treatment of wide-neck bifurcation aneurysms as a bailout technique after failure of Y stent-assisted coiling.<\/jats:p>","DOI":"10.15274\/inr-2014-10065","type":"journal-article","created":{"date-parts":[[2014,6,26]],"date-time":"2014-06-26T03:33:30Z","timestamp":1403753610000},"page":"677-685","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":5,"title":["Hybrid Y Stenting with the Waffle-Cone"],"prefix":"10.1177","volume":"20","author":[{"given":"Nicola","family":"Limbucci","sequence":"first","affiliation":[{"name":"Interventional Neuroradiology Unit, Careggi University Hospital; Florence, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sergio","family":"Nappini","sequence":"additional","affiliation":[{"name":"Interventional Neuroradiology Unit, Careggi University Hospital; Florence, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Leonardo","family":"Renieri","sequence":"additional","affiliation":[{"name":"Interventional Neuroradiology Unit, Careggi University Hospital; Florence, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arturo","family":"Consoli","sequence":"additional","affiliation":[{"name":"Interventional Neuroradiology Unit, Careggi University Hospital; Florence, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrea","family":"Rosi","sequence":"additional","affiliation":[{"name":"Interventional Neuroradiology Unit, Careggi University Hospital; Florence, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giovanni","family":"Grillea","sequence":"additional","affiliation":[{"name":"Neuroradiology Unit, Neuromed Institute; Pozzilli Isernia, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcello","family":"Bartolo","sequence":"additional","affiliation":[{"name":"Neuroradiology Unit, Neuromed Institute; Pozzilli Isernia, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Salvatore","family":"Mangiafico","sequence":"additional","affiliation":[{"name":"Interventional Neuroradiology Unit, Careggi University Hospital; Florence, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2014,1,1]]},"reference":[{"key":"bibr1-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A2403"},{"key":"bibr2-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3574"},{"issue":"3","key":"bibr3-INR-2014-10065","first-page":"509","volume":"25","author":"Chow MM","year":"2004","journal-title":"Am J Neuroradiol"},{"key":"bibr4-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.1179\/016164104225013969"},{"issue":"5","key":"bibr5-INR-2014-10065","first-page":"1035","volume":"56","author":"Thorell WE","year":"2005","journal-title":"Neurosurgery"},{"key":"bibr6-INR-2014-10065","doi-asserted-by":"crossref","unstructured":"Conrad MD, Brasiliense LB, Richie AN, Y stenting assisted coiling using a new low profile visible intraluminal support device for wide necked basilar tip aneurysms: a technical report. J Neurointerv Surg. 2013. [Epub ahead of print].","DOI":"10.1136\/neurintsurg-2013-010818"},{"key":"bibr7-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3464"},{"key":"bibr8-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0000000000000015"},{"issue":"4","key":"bibr9-INR-2014-10065","first-page":"ONS258","volume":"58","author":"Horowitz M","year":"2006","journal-title":"Neurosurgery"},{"key":"bibr10-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.1177\/15910199080140S210"},{"key":"bibr11-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.1007\/s00234-010-0766-6"},{"key":"bibr12-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.3340\/jkns.2012.51.4.222"},{"key":"bibr13-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.1007\/s00701-010-0934-9"},{"key":"bibr14-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.1177\/159101991201800103"},{"key":"bibr15-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.4103\/2152-7806.106268"},{"key":"bibr16-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.3340\/jkns.2011.50.6.517"},{"key":"bibr17-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.1016\/j.ejrad.2012.11.005"},{"key":"bibr18-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.1136\/jnis.2010.004275"},{"key":"bibr19-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3692"},{"key":"bibr20-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3869"},{"key":"bibr21-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.1136\/jnis.2010.002931"},{"key":"bibr22-INR-2014-10065","doi-asserted-by":"crossref","unstructured":"Aguilar-P\u00e9rez M, Kurre W, Fischer S, Coil occlusion of wide-neck bifurcation aneurysms assisted by a novel intra- to extra-aneurysmatic neck-bridging device (pCONus): initial experience. Am J Neuroradiol. 2013. doi: 10.3174\/ajnr.A3807. [Epub ahead of print].","DOI":"10.3174\/ajnr.A3807"},{"key":"bibr23-INR-2014-10065","doi-asserted-by":"crossref","unstructured":"Mpotsaris A, Henkes H, Weber W, Waffle Y Technique: pCONus for tandem bifurcation aneurysms of the middle cerebral artery. J Neurointerv Surg. 2013. doi: 10.1136\/neurintsurg-2013-010921.rep. [Epub ahead of print].","DOI":"10.1136\/bcr-2013-010921"},{"key":"bibr24-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.3174\/ajnr.A3479"},{"key":"bibr25-INR-2014-10065","doi-asserted-by":"publisher","DOI":"10.1227\/NEU.0b013e3182846d9f"}],"container-title":["Interventional Neuroradiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.15274\/INR-2014-10065","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.15274\/INR-2014-10065","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,29]],"date-time":"2026-04-29T10:56:13Z","timestamp":1777460173000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/10.15274\/INR-2014-10065"}},"subtitle":["A Technical Note"],"short-title":[],"issued":{"date-parts":[[2014,1,1]]},"references-count":25,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2014,11]]}},"alternative-id":["10.15274\/INR-2014-10065"],"URL":"https:\/\/doi.org\/10.15274\/inr-2014-10065","relation":{},"ISSN":["1591-0199","2385-2011"],"issn-type":[{"value":"1591-0199","type":"print"},{"value":"2385-2011","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,1,1]]}}}