{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T13:28:37Z","timestamp":1786973317797,"version":"build-2736575974"},"reference-count":55,"publisher":"Bioscientifica","issue":"7","license":[{"start":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T00:00:00Z","timestamp":1783036800000},"content-version":"vor","delay-in-days":2,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["journals.bioscientifica.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7,1]]},"abstract":"<jats:p>This review presents how surgeons should choose femoral interference screw in anterior cruciate ligament (ACL) reconstruction \u2013 insertion direction (inside-out vs outside-in), tunnel shape (round vs rectangular), screw position (anterior vs posterior), and screw material (metal, bioabsorbable, PEEK, magnesium) \u2013 to balance fixation strength, anatomic fidelity, and revision feasibility. Inside-out maximizes aperture compression and preserves the lateral femoral cortex but requires deep flexion and precise trajectory (risk of iatrogenic cartilage contact\/posterior wall breach). Outside-in improves visualization and guide control yet needs a large lateral cortical socket and can push the bone plug intra-articularly as the screw advances from cortex to joint. Rectangular tunnels better match the native footprint, improving rotational control and interface congruity, while round tunnels simplify preparation but allow plug rotation and may use bone less efficiently at the aperture. Posterior screw placement (particularly with the inside-out technique) enhances cancellous-to-cancellous compression but risks posterior cortical breach injury; anterior placement protects fibers and favors footprint fidelity but may reduce cancellous compression. Metal offers high stiffness and no tapping but creates MRI artifact and requires removal if present at revision. Bioabsorbable materials avoid artifact\/removal yet are weaker and may fracture in sclerotic tunnels. PEEK (metal-like without artifact) and magnesium (osteoconductive\/resorbable) are promising but lack long-term data. No single method is universally optimal. Decisions should be individualized to visualization needs, cortical\/bone-stock preservation, expected revision strategy, and patient factors (age, activity, bone quality).<\/jats:p>","DOI":"10.1530\/eor-2025-0247","type":"journal-article","created":{"date-parts":[[2026,7,1]],"date-time":"2026-07-01T12:52:44Z","timestamp":1782910364000},"page":"827-836","update-policy":"https:\/\/doi.org\/10.1530\/crossmarkpolicy-16","source":"Crossref","is-referenced-by-count":0,"title":["No single best technique: trade-offs in femoral interference screw fixation for bone\u2013patellar tendon\u2013bone anterior cruciate ligament reconstruction"],"prefix":"10.1530","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3503-0360","authenticated-orcid":true,"given":"Seikai","family":"Toyooka","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Teikyo University School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yutoshi","family":"Osaki","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Teikyo University School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Noriaki","family":"Arai","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Teikyo University School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hirotaka","family":"Kawano","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Teikyo University School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takumi","family":"Nakagawa","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Teikyo University School of Medicine, Tokyo, Japan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"416","published-online":{"date-parts":[[2026,7,1]]},"reference":[{"key":"2026081709033161300_bib1","doi-asserted-by":"crossref","first-page":"3071","DOI":"10.1016\/j.arthro.2018.07.041","article-title":"Editorial commentary: the search for the perfect fixation method in anterior cruciate ligament reconstruction continues","volume":"34","author":"Nuelle","year":"2018","journal-title":"Arthroscopy"},{"key":"2026081709033161300_bib2","article-title":"ACL reconstruction with quadriceps soft tissue autograft versus bone-patellar tendon-bone autograft in cutting and pivoting athletes: outcomes at minimum 2-year follow-up","volume":"11","author":"Renfree","year":"2023","journal-title":"Orthop J Sports Med"},{"key":"2026081709033161300_bib3","doi-asserted-by":"crossref","DOI":"10.1002\/jeo2.70439","article-title":"Superior long-term stability and function associated with femoral cortical button versus interference screw fixation in ACL reconstruction: a systematic review and meta-analysis","volume":"12","author":"Elias","year":"2025","journal-title":"J Exp Orthop"},{"key":"2026081709033161300_bib4","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.arthro.2023.11.005","article-title":"Anterior cruciate ligament reconstruction: fixation techniques","volume":"40","author":"McDermott","year":"2024","journal-title":"Arthroscopy"},{"key":"2026081709033161300_bib5","doi-asserted-by":"crossref","first-page":"220","DOI":"10.1136\/jisakos-2018-000206","article-title":"Varying femoral-sided fixation techniques in anterior cruciate ligament reconstruction have similar clinical outcomes: a network meta-analysis","volume":"3","author":"Shah","year":"2018","journal-title":"J ISAKOS"},{"key":"2026081709033161300_bib6","doi-asserted-by":"crossref","first-page":"3518","DOI":"10.1007\/s00167-019-05431-4","article-title":"Femoral-tibial fixation affects risk of revision and reoperation after anterior cruciate ligament reconstruction using hamstring autograft","volume":"27","author":"Spragg","year":"2019","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2026081709033161300_bib7","doi-asserted-by":"crossref","first-page":"1388","DOI":"10.1007\/s00167-021-06607-7","article-title":"Non-anatomic tunnel position increases the risk of revision anterior cruciate ligament reconstruction","volume":"30","author":"Byrne","year":"2022","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2026081709033161300_bib8","doi-asserted-by":"crossref","DOI":"10.2106\/JBJS.RVW.19.00066","article-title":"Femoral interference screw fixation in ACL reconstruction using bone-patellar tendon-bone grafts","volume":"8","author":"Su","year":"2020","journal-title":"JBJS Rev"},{"key":"2026081709033161300_bib9","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1186\/s13018-021-02872-x","article-title":"Transportal versus all-inside techniques of anterior cruciate ligament reconstruction: a systematic review","volume":"16","author":"Bhimani","year":"2021","journal-title":"J Orthop Surg Res"},{"key":"2026081709033161300_bib10","doi-asserted-by":"crossref","first-page":"2371","DOI":"10.1007\/s00167-017-4786-1","article-title":"The transportal technique shows better clinical results than the transtibial techniques for single-bundle anterior cruciate ligament reconstruction","volume":"26","author":"Ro","year":"2018","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2026081709033161300_bib11","doi-asserted-by":"crossref","first-page":"e131","DOI":"10.1016\/j.eats.2019.09.011","article-title":"Positioning technique of the fixed knee in hyperflexion for the transportal femoral tunnel during reconstruction of the anterior cruciate ligament","volume":"9","author":"Rocha de Faria","year":"2020","journal-title":"Arthrosc Tech"},{"key":"2026081709033161300_bib12","article-title":"Hyperflexion and femoral interference screw insertion in ACL reconstruction","volume":"6","author":"Steiner","year":"2018","journal-title":"Orthop J Sports Med"},{"key":"2026081709033161300_bib13","article-title":"The relationship between lateral femoral anatomic structures and the femoral tunnel outlet in anterior cruciate ligament reconstruction using the transportal technique: a 3-dimensional simulation analysis","volume":"8","author":"Chung","year":"2020","journal-title":"Orthop J Sports Med"},{"key":"2026081709033161300_bib14","first-page":"1","article-title":"Optimal condition to create femoral tunnel considering combined influence of knee flexion and transverse drill angle in anatomical single-bundle ACL reconstruction using medial portal technique: 3D simulation study","volume":"2018","author":"Kim","year":"2018","journal-title":"Biomed Res Int"},{"key":"2026081709033161300_bib15","doi-asserted-by":"crossref","first-page":"1154","DOI":"10.2174\/1874325001711011154","article-title":"Anatomic outside-in reconstruction of the anterior cruciate ligament using femoral fixation with metallic interference screw and surgical staples (Agrafe) in the tibia: an effective low-cost technique","volume":"11","author":"Diego","year":"2017","journal-title":"Open Orthop J"},{"key":"2026081709033161300_bib16","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1186\/s40634-021-00373-8","article-title":"Technical note: rectangular femoral tunnel for anterior cruciate ligament reconstruction using a new ultrasonic device: a feasibility study","volume":"8","author":"Seil","year":"2021","journal-title":"J Exp Orthop"},{"key":"2026081709033161300_bib17","doi-asserted-by":"crossref","first-page":"e1889","DOI":"10.1016\/j.eats.2022.07.001","article-title":"Anterior cruciate ligament reconstruction using bone-patella tendon-bone autograft with press-fit femoral fixation: the original chambat technique","volume":"11","author":"Levy","year":"2022","journal-title":"Arthrosc Tech"},{"key":"2026081709033161300_bib18","doi-asserted-by":"crossref","first-page":"e1481","DOI":"10.1016\/j.eats.2016.08.026","article-title":"A surgical technique for posterolateral placement of interference screw accurately in tibial tunnel in single-bundle anterior cruciate ligament reconstruction","volume":"5","author":"Parate","year":"2016","journal-title":"Arthrosc Tech"},{"key":"2026081709033161300_bib19","doi-asserted-by":"crossref","first-page":"1804","DOI":"10.1016\/j.arthro.2013.07.263","article-title":"Effects of tunnel dilation and interference screw position on the biomechanical properties of tendon graft fixation for anterior cruciate ligament reconstruction","volume":"29","author":"Higano","year":"2013","journal-title":"Arthroscopy"},{"key":"2026081709033161300_bib20","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1016\/S0749-8063(96)90223-6","article-title":"Comparison of \u2018inside-out\u2019 and \u2018outside-in\u2019 interference screw fixation for anterior cruciate ligament surgery in a bovine knee","volume":"12","author":"Bryan","year":"1996","journal-title":"Arthroscopy"},{"key":"2026081709033161300_bib21","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1007\/s00167-017-4732-2","article-title":"Contact area between femoral tunnel and interference screw in anatomic rectangular tunnel ACL reconstruction: a comparison of outside-in and trans-portal inside-out techniques","volume":"26","author":"Hiramatsu","year":"2018","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2026081709033161300_bib22","article-title":"Influence of graft bending angle on femoral tunnel widening after double-bundle ACL reconstruction: Comparison of transportal and outside-in techniques","volume":"9","author":"Lee","year":"2021","journal-title":"Orthop J Sports Med"},{"key":"2026081709033161300_bib23","doi-asserted-by":"crossref","first-page":"2338","DOI":"10.1007\/s00167-017-4655-y","article-title":"No difference in graft healing or clinical outcome between trans-portal and outside-in techniques after anterior cruciate ligament reconstruction","volume":"26","author":"Sim","year":"2018","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2026081709033161300_bib24","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1007\/s00776-015-0705-9","article-title":"Anatomic ACL reconstruction: rectangular tunnel\/bone-patellar tendon-bone or triple-bundle\/semitendinosus tendon grafting","volume":"20","author":"Shino","year":"2015","journal-title":"J Orthop Sci"},{"key":"2026081709033161300_bib25","doi-asserted-by":"crossref","first-page":"886","DOI":"10.1016\/j.jos.2017.05.006","article-title":"Biomechanical characteristics of the anatomic rectangular tunnel anterior cruciate ligament reconstruction with a bone-patellar tendon-bone graft","volume":"22","author":"Mae","year":"2017","journal-title":"J Orthop Sci"},{"key":"2026081709033161300_bib26","doi-asserted-by":"crossref","first-page":"1294","DOI":"10.1016\/j.arthro.2014.05.027","article-title":"Biomechanical comparison between the rectangular-tunnel and the round-tunnel anterior cruciate ligament reconstruction procedures with a bone-patellar tendon-bone graft","volume":"30","author":"Suzuki","year":"2014","journal-title":"Arthroscopy"},{"key":"2026081709033161300_bib27","doi-asserted-by":"crossref","first-page":"925","DOI":"10.4055\/cios24081","article-title":"Oval tunnel shows better rotational stability than round tunnel in anatomical single-bundle anterior cruciate ligament reconstruction: biomechanical study in a porcine model","volume":"16","author":"Kim","year":"2024","journal-title":"Clin Orthop Surg"},{"key":"2026081709033161300_bib28","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1136\/jisakos-2018-000213","article-title":"No difference in initial fixation or 1-year outcomes with outside in metallic or bioabsorbable interference femoral screws in rectangular tunnel bone-patellar tendon-bone graft for anterior cruciate ligament reconstruction","volume":"3","author":"Shiwaku","year":"2018","journal-title":"J ISAKOS"},{"key":"2026081709033161300_bib29","doi-asserted-by":"crossref","first-page":"e1271","DOI":"10.1016\/j.eats.2023.03.018","article-title":"Ultrasonic technique for femoral tunnel creation in anterior cruciate ligament reconstruction","volume":"12","author":"Mae","year":"2023","journal-title":"Arthrosc Tech"},{"key":"2026081709033161300_bib30","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1186\/s12891-020-03913-y","article-title":"Clinical study of anatomical ACL reconstruction using a rounded rectangular dilator","volume":"22","author":"Nakase","year":"2021","journal-title":"BMC Musculoskelet Disord"},{"key":"2026081709033161300_bib31","doi-asserted-by":"crossref","first-page":"e417","DOI":"10.1016\/j.eats.2014.04.003","article-title":"Avoiding graft-tunnel length mismatch in anterior cruciate ligament reconstruction: the single-bone plug technique","volume":"3","author":"Grawe","year":"2014","journal-title":"Arthrosc Tech"},{"key":"2026081709033161300_bib32","doi-asserted-by":"crossref","first-page":"e551","DOI":"10.1016\/j.eats.2016.02.003","article-title":"Posterior wall blowout during anterior cruciate ligament reconstruction: suspensory cortical fixation with a screw and washer post","volume":"5","author":"Mitchell","year":"2016","journal-title":"Arthrosc Tech"},{"key":"2026081709033161300_bib33","doi-asserted-by":"crossref","first-page":"843","DOI":"10.1007\/s11999-011-1948-1","article-title":"Surgical technique: revision ACL reconstruction with a rectangular tunnel technique","volume":"470","author":"Shino","year":"2012","journal-title":"Clin Orthop Relat Res"},{"key":"2026081709033161300_bib34","doi-asserted-by":"crossref","first-page":"139","DOI":"10.4103\/jajs.jajs_131_22","article-title":"A systematic review of noncircular (rectangle, oval) femoral tunnel anterior cruciate ligament reconstruction: does it improve outcomes?","volume":"10","author":"Ghasemi","year":"2023","journal-title":"J Arthrosc Joint Surg"},{"key":"2026081709033161300_bib35","doi-asserted-by":"crossref","first-page":"1933","DOI":"10.1016\/j.arthro.2021.11.050","article-title":"No differences in clinical outcomes between rectangular and round tunnel techniques for anterior crucial ligament reconstruction","volume":"38","author":"Kim","year":"2022","journal-title":"Arthroscopy"},{"key":"2026081709033161300_bib36","doi-asserted-by":"crossref","first-page":"1875","DOI":"10.1016\/j.arthro.2020.01.050","article-title":"Does bone plug and graft orientation (inferior versus posterior) alter native femoral footprint coverage in bone patellar tendon bone anterior cruciate ligament reconstruction?","volume":"36","author":"Bedi","year":"2020","journal-title":"Arthroscopy"},{"key":"2026081709033161300_bib37","doi-asserted-by":"crossref","first-page":"e2783","DOI":"10.1016\/j.eats.2021.08.025","article-title":"Transtibial anterior cruciate ligament reconstruction: tips for a successful anatomic reconstruction","volume":"10","author":"Manderle","year":"2021","journal-title":"Arthrosc Tech"},{"key":"2026081709033161300_bib38","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1186\/s40634-023-00677-x","article-title":"Increased ACL direct insertion coverage provided more positive biomechanical effects on graft and bone tunnel during knee flexion: a simulation study","volume":"10","author":"Xiao","year":"2023","journal-title":"J Exp Orthop"},{"key":"2026081709033161300_bib39","article-title":"Posterior wall blowout in anterior cruciate ligament reconstruction: a review of anatomic and surgical considerations: a review of anatomic and surgical considerations","volume":"4","author":"Mitchell","year":"2016","journal-title":"Orthop J Sports Med"},{"key":"2026081709033161300_bib40","doi-asserted-by":"crossref","first-page":"7","DOI":"10.25259\/JASSM_20_2021","article-title":"Accuracy of transportal femoral aimer in placement of femoral tunnel during arthroscopic anterior cruciate ligament reconstruction: an observational study","volume":"3","author":"Thapa","year":"2021","journal-title":"J Arthroscopic Surg Sports Med"},{"key":"2026081709033161300_bib41","doi-asserted-by":"crossref","DOI":"10.1016\/j.eats.2025.103796","article-title":"Anterior cruciate ligament reconstruction with bone-patellar tendon-bone autograft: top 10 pearls","volume":"14","author":"Rechter","year":"2025","journal-title":"Arthrosc Tech"},{"key":"2026081709033161300_bib42","doi-asserted-by":"crossref","first-page":"390","DOI":"10.3390\/medicina59020390","article-title":"Anterior screw insertion results in greater tibial tunnel enlargement rates after single-bundle anterior cruciate ligament reconstruction than posterior insertion: a retrospective study","volume":"59","author":"Kong","year":"2023","journal-title":"Medicina"},{"key":"2026081709033161300_bib43","article-title":"Comparison of bioabsorbable and metallic interference screws for graft fixation during ACL reconstruction: a meta-analysis of randomized controlled trials","volume":"9","author":"Xu","year":"2021","journal-title":"Orthop J Sports Med"},{"key":"2026081709033161300_bib44","doi-asserted-by":"crossref","first-page":"e53","DOI":"10.1016\/j.asmr.2019.10.001","article-title":"Biocomposite interference screws in anterior cruciate ligament reconstruction: osteoconductivity and degradation","volume":"2","author":"Barber","year":"2020","journal-title":"Arthrosc Sports Med Rehabil"},{"key":"2026081709033161300_bib45","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1016\/j.arthro.2014.11.011","article-title":"Bioabsorbable versus metallic interference screws in anterior cruciate ligament reconstruction: a systematic review of overlapping meta-analyses","volume":"31","author":"Mascarenhas","year":"2015","journal-title":"Arthroscopy"},{"key":"2026081709033161300_bib46","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1007\/s00167-018-5037-9","article-title":"Bioabsorbable screws, whatever the composition, can result in symptomatic intra-osseous tibial tunnel cysts after ACL reconstruction","volume":"27","author":"Chevallier","year":"2019","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2026081709033161300_bib47","doi-asserted-by":"crossref","first-page":"2577","DOI":"10.1007\/s00167-018-5275-x","article-title":"Anterior cruciate ligament reconstruction is associated with greater tibial tunnel widening when using a bioabsorbable screw compared to an all-inside technique with suspensory fixation","volume":"27","author":"Monaco","year":"2019","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2026081709033161300_bib48","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1016\/j.arthro.2009.12.011","article-title":"Bioabsorbable versus metallic interference screw fixation in anterior cruciate ligament reconstruction: a meta-analysis of randomized controlled trials","volume":"26","author":"Shen","year":"2010","journal-title":"Arthroscopy"},{"key":"2026081709033161300_bib49","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.jor.2025.06.005","article-title":"Bioabsorbable implants are a viable alternative to traditional metallic implants in orthopaedic surgery: a systematic review and meta-analysis","volume":"65","author":"Blackman","year":"2025","journal-title":"J Orthop"},{"key":"2026081709033161300_bib50","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1007\/s43465-023-01029-8","article-title":"PEEK interference screws show significant tunnel enlargement after ACL reconstruction and is comparable to adjustable-length loop cortical button fixation","volume":"58","author":"Coppola","year":"2024","journal-title":"Indian J Orthop"},{"key":"2026081709033161300_bib51","doi-asserted-by":"crossref","DOI":"10.3389\/fpubh.2022.1003591","article-title":"The safety and effectiveness comparison of Delta Medical\u2019s PEEK interface screw and endobutton and that of Smith & Nephew\u2019s in arthroscopic anterior cruciate ligament reconstruction: a multicenter prospective double-blind randomized controlled clinical trial","volume":"10","author":"Gao","year":"2022","journal-title":"Front Public Health"},{"key":"2026081709033161300_bib52","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1186\/s40634-023-00663-3","article-title":"Interference screws manufactured from magnesium display similar primary stability for soft tissue anterior cruciate ligament graft fixation compared to a biocomposite material - a biomechanical study","volume":"10","author":"Deichsel","year":"2023","journal-title":"J Exp Orthop"},{"key":"2026081709033161300_bib53","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-023-39513-8","article-title":"Mechanical properties of a bioabsorbable magnesium interference screw for anterior cruciate ligament reconstruction in various testing bone materials","volume":"13","author":"Siroros","year":"2023","journal-title":"Sci Rep"},{"key":"2026081709033161300_bib54","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1007\/s00167-011-1814-4","article-title":"A CT-based classification of prior ACL femoral tunnel location for planning revision ACL surgery","volume":"20","author":"Magnussen","year":"2012","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"2026081709033161300_bib55","doi-asserted-by":"crossref","first-page":"1458","DOI":"10.2106\/JBJS.22.01321","article-title":"Management of bone loss and tunnel widening in revision ACL reconstruction","volume":"105","author":"McMellen","year":"2023","journal-title":"J Bone Joint Surg Am"}],"container-title":["EFORT Open Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/eor.bioscientifica.com\/view\/journals\/eor\/11\/7\/EOR-2025-0247.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/eor.bioscientifica.com\/downloadpdf\/journals\/eor\/11\/7\/EOR-2025-0247.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/journals.bioscientifica.com\/eor\/article-pdf\/11\/7\/827\/519764\/eor-2025-0247.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/journals.bioscientifica.com\/eor\/article-pdf\/11\/7\/827\/519764\/eor-2025-0247.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T13:03:59Z","timestamp":1786971839000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.bioscientifica.com\/eor\/article\/11\/7\/827\/77538\/No-single-best-technique-trade-offs-in-femoral"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,1]]},"references-count":55,"journal-issue":{"issue":"7","published-online":{"date-parts":[[2026,7,1]]},"published-print":{"date-parts":[[2026,7,1]]}},"URL":"https:\/\/doi.org\/10.1530\/eor-2025-0247","relation":{},"ISSN":["2058-5241"],"issn-type":[{"value":"2058-5241","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,1]]}}}