{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T09:56:32Z","timestamp":1790934992387,"version":"4.1.0"},"reference-count":95,"publisher":"Bioscientifica","issue":"10","license":[{"start":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T00:00:00Z","timestamp":1790899200000},"content-version":"vor","delay-in-days":1,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["journals.bioscientifica.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,10,1]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:p>Digital orthopedics integrates artificial intelligence, finite element analysis, virtual surgical planning, intraoperative navigation, robotics, and three-dimensional printing into a precise, individualized workflow for scaphoid fracture management. Artificial intelligence-based algorithms achieve high diagnostic accuracy for scaphoid fractures on plain radiographs, aid in detecting occult fractures, and support treatment decisions. Three-dimensional fracture mapping and finite element analysis enable quantitative assessment of fracture morphology and biomechanical stability, supporting individualized preoperative planning. Computer-assisted navigation reduces radiation exposure and guidewire attempts compared with conventional fluoroscopy but remains limited by registration inaccuracy and dependence on manual execution. Robot-assisted surgery improves procedural consistency and screw accuracy, with a learning curve of approximately 10\u201320 cases; however, it is constrained by longer setup times, high costs, and predominantly level IV evidence. Virtual surgical planning combined with three-dimensional printing provides patient-specific percutaneous guides, reduction templates, anatomical models, and custom prostheses, improving accuracy, reducing radiation exposure, and enabling motion-preserving salvage for scaphoid nonunions and scaphoid nonunion advanced collapse. Current evidence is largely based on small case series and cadaveric studies, highlighting the need for standardized protocols and high-quality comparative trials to support widespread adoption.<\/jats:p>","DOI":"10.1530\/eor-2026-0084","type":"journal-article","created":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T09:13:21Z","timestamp":1790932401000},"page":"1048-1063","update-policy":"https:\/\/doi.org\/10.1530\/crossmarkpolicy-16","source":"Crossref","is-referenced-by-count":0,"title":["A review of digital orthopedic techniques in pre- and intra-operative management of scaphoid fracture"],"prefix":"10.1530","volume":"11","author":[{"ORCID":"https:\/\/orcid.org\/0009-0007-8283-4680","authenticated-orcid":true,"given":"Shuai","family":"Wang","sequence":"first","affiliation":[{"name":"Department of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University 1 , ,","place":["Beijing, China"]},{"name":"Department of Hand Surgery, Beijing Jishuitan Hospital, Peking University Fourth School of Clinical Medicine 2 , ,","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7788-8165","authenticated-orcid":true,"given":"Zhe","family":"Yi","sequence":"additional","affiliation":[{"name":"Department of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University 1 , ,","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9286-9285","authenticated-orcid":true,"given":"Wei","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University 1 , ,","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0778-1017","authenticated-orcid":true,"given":"Bo","family":"Liu","sequence":"additional","affiliation":[{"name":"Department of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University 1 , ,","place":["Beijing, China"]},{"name":"Department of Hand Surgery, Beijing Jishuitan Hospital, Peking University Fourth School of Clinical Medicine 2 , ,","place":["Beijing, China"]},{"name":"Beijing Research Institute of Traumatology and Orthopaedics 3 , ,","place":["Beijing, China"]}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"416","published-online":{"date-parts":[[2026,10,1]]},"reference":[{"key":"2026100205131803900_bib1","doi-asserted-by":"crossref","first-page":"2553","DOI":"10.1007\/s11999-010-1261-4","article-title":"Fractures in brief: scaphoid fractures","volume":"468","author":"Tysver","year":"2010","journal-title":"Clin Orthop Relat Res"},{"key":"2026100205131803900_bib2","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1302\/0301-620X.98B5.36938","article-title":"The epidemiology of fractures of the scaphoid: impact of age, gender, deprivation and seasonality","volume":"98-b","author":"Garala","year":"2016","journal-title":"Bone Jt J"},{"key":"2026100205131803900_bib3","doi-asserted-by":"crossref","first-page":"1797","DOI":"10.1016\/j.jhsa.2015.05.003","article-title":"Treatment of scaphoid nonunion: a systematic review of the existing evidence","volume":"40","author":"Pinder","year":"2015","journal-title":"J Hand Surg Am"},{"key":"2026100205131803900_bib4","doi-asserted-by":"crossref","first-page":"S68","DOI":"10.1016\/j.arth.2020.04.048","article-title":"Digital orthopaedics: a glimpse into the future in the midst of a pandemic","volume":"35","author":"Bini","year":"2020","journal-title":"J Arthroplast"},{"key":"2026100205131803900_bib5","doi-asserted-by":"crossref","first-page":"2425","DOI":"10.3390\/diagnostics14212425","article-title":"The detection and classification of scaphoid fractures in radiograph by using a convolutional neural network","volume":"14","author":"Yang","year":"2024","journal-title":"Diagnostics"},{"key":"2026100205131803900_bib6","doi-asserted-by":"crossref","first-page":"895","DOI":"10.3390\/diagnostics12040895","article-title":"Scaphoid fracture detection by using convolutional neural network","volume":"12","author":"Yang","year":"2022","journal-title":"Diagnostics"},{"key":"2026100205131803900_bib7","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1177\/17531934211026139","article-title":"Application of deep learning: detection of obsolete scaphoid fractures with artificial neural networks","volume":"46","author":"Yoon","year":"2021","journal-title":"J Hand Surg Eur Vol"},{"key":"2026100205131803900_bib8","doi-asserted-by":"crossref","first-page":"1575","DOI":"10.1007\/s00330-022-09205-4","article-title":"Musculoskeletal radiologist-level performance by using deep learning for detection of scaphoid fractures on conventional multi-view radiographs of hand and wrist","volume":"33","author":"Hendrix","year":"2023","journal-title":"Eur Radiol"},{"key":"2026100205131803900_bib9","doi-asserted-by":"crossref","DOI":"10.1148\/ryai.2021200260","article-title":"Development and validation of a convolutional neural network for automated detection of scaphoid fractures on conventional radiographs","volume":"3","author":"Hendrix","year":"2021","journal-title":"Radiol Artif Intell"},{"key":"2026100205131803900_bib10","doi-asserted-by":"crossref","DOI":"10.1001\/jamanetworkopen.2021.6096","article-title":"Development and validation of a deep learning model using convolutional neural networks to identify scaphoid fractures in radiographs","volume":"4","author":"Yoon","year":"2021","journal-title":"JAMA Netw Open"},{"key":"2026100205131803900_bib11","doi-asserted-by":"crossref","first-page":"1836","DOI":"10.1097\/CORR.0000000000002663","article-title":"CORR insights(R): can a deep learning algorithm improve detection of occult scaphoid fractures in plain radiographs? A clinical validation study","volume":"481","author":"Wilson","year":"2023","journal-title":"Clin Orthop Relat Res"},{"key":"2026100205131803900_bib12","doi-asserted-by":"crossref","first-page":"1850","DOI":"10.3390\/jcm14061850","article-title":"Deep learning in scaphoid nonunion treatment","volume":"14","author":"Tumen","year":"2025","journal-title":"J Clin Med"},{"key":"2026100205131803900_bib13","doi-asserted-by":"crossref","first-page":"1198","DOI":"10.3390\/biomedicines12061198","article-title":"Deep learning-based surgical treatment recommendation and nonsurgical prognosis status classification for scaphoid fractures by automated X-ray image recognition","volume":"12","author":"Su","year":"2024","journal-title":"Biomedicines"},{"key":"2026100205131803900_bib14","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1007\/s00068-020-01468-0","article-title":"Evaluation of an artificial intelligence system for diagnosing scaphoid fracture on direct radiography","volume":"48","author":"Ozkaya","year":"2022","journal-title":"Eur J Trauma Emerg Surg"},{"key":"2026100205131803900_bib15","article-title":"Application of artificial intelligence and machine learning in diagnosing scaphoid fractures: a systematic review","volume":"15","author":"Orji","year":"2023","journal-title":"Cureus"},{"key":"2026100205131803900_bib16","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1016\/j.jhsa.2024.01.020","article-title":"Diagnostic performance of artificial intelligence for detection of scaphoid and distal radius fractures: a systematic review","volume":"49","author":"Oeding","year":"2024","journal-title":"J Hand Surg Am"},{"key":"2026100205131803900_bib17","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1177\/17531934241312896","article-title":"Artificial intelligence and machine learning capabilities in the detection of acute scaphoid fracture: a critical review","volume":"50","author":"Miller","year":"2025","journal-title":"J Hand Surg"},{"key":"2026100205131803900_bib18","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1177\/17531934221127092","article-title":"Evaluation of a convolutional neural network to identify scaphoid fractures on radiographs","volume":"48","author":"Li","year":"2023","journal-title":"J Hand Surg Eur Vol"},{"key":"2026100205131803900_bib19","doi-asserted-by":"crossref","first-page":"1657","DOI":"10.3390\/diagnostics13091657","article-title":"Clinical validation of an artificial intelligence model for detecting distal radius, ulnar styloid, and scaphoid fractures on conventional wrist radiographs","volume":"13","author":"Lee","year":"2023","journal-title":"Diagnostics"},{"key":"2026100205131803900_bib20","doi-asserted-by":"crossref","first-page":"2653","DOI":"10.1097\/CORR.0000000000001318","article-title":"Is deep learning on par with human observers for detection of radiographically visible and occult fractures of the scaphoid?","volume":"478","author":"Langerhuizen","year":"2020","journal-title":"Clin Orthop Relat Res"},{"key":"2026100205131803900_bib21","doi-asserted-by":"crossref","first-page":"4341","DOI":"10.1007\/s00330-023-10473-x","article-title":"Artificial intelligence for X-ray scaphoid fracture detection: a systematic review and diagnostic test accuracy meta-analysis","volume":"34","author":"Kraus","year":"2024","journal-title":"Eur Radiol"},{"key":"2026100205131803900_bib22","doi-asserted-by":"crossref","first-page":"451","DOI":"10.1177\/17531934221143434","article-title":"Commentary on: Li et al. Evaluation of a convolutional neural network to identify scaphoid fractures on radiographs. J Hand Surg Eur. 2022, 48","volume":"48","author":"Horwitz","year":"2023","journal-title":"J Hand Surg Eur"},{"key":"2026100205131803900_bib23","doi-asserted-by":"crossref","first-page":"1633","DOI":"10.1007\/s11547-025-02028-5","article-title":"Application of artificial intelligence in the diagnosis of scaphoid fractures: impact of automated detection of scaphoid fractures in a real-life study","volume":"130","author":"Hern\u00e1iz Ferrer","year":"2025","journal-title":"La Radiologia Med"},{"key":"2026100205131803900_bib24","first-page":"210","article-title":"Automatic annotation tool to support supervised machine learning for scaphoid fracture detection. Decision support systems and education","volume":"255","author":"Foufi","year":"2018","journal-title":"Stud Health Technol Inf"},{"key":"2026100205131803900_bib25","doi-asserted-by":"crossref","DOI":"10.1016\/j.ejrad.2025.112309","article-title":"A novel segmentation-based deep learning model for enhanced scaphoid fracture detection","volume":"191","author":"Butzow","year":"2025","journal-title":"Eur J Radiol"},{"key":"2026100205131803900_bib26","doi-asserted-by":"crossref","first-page":"711","DOI":"10.1016\/j.jhsa.2025.01.021","article-title":"A machine learning algorithm to estimate the probability of a true scaphoid fracture after wrist trauma","volume":"50","author":"Bulstra","year":"2025","journal-title":"J Hand Surg Am"},{"key":"2026100205131803900_bib27","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1055\/s-0039-1693050","article-title":"Scaphoid fracture patterns-part one: three-dimensional computed tomography analysis","volume":"08","author":"Drijkoningen","year":"2019","journal-title":"J Wrist Surg"},{"key":"2026100205131803900_bib28","doi-asserted-by":"crossref","first-page":"1633","DOI":"10.1007\/s00256-020-03457-1","article-title":"3D mapping of scaphoid fractures and comminution","volume":"49","author":"Turow","year":"2020","journal-title":"Skelet Radiol"},{"key":"2026100205131803900_bib29","doi-asserted-by":"crossref","first-page":"141","DOI":"10.2106\/JBJS.16.00021","article-title":"Three-dimensional analysis of acute scaphoid fracture displacement: proximal extension deformity of the scaphoid","volume":"99","author":"Schwarcz","year":"2017","journal-title":"J Bone Joint Surg Am"},{"key":"2026100205131803900_bib30","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1177\/17531934221145516","article-title":"Mechanism of scaphoid waist fracture: finite element analysis","volume":"48","author":"Santoshi","year":"2023","journal-title":"J Hand Surg Eur Vol"},{"key":"2026100205131803900_bib31","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1016\/j.otsr.2018.07.013","article-title":"Comparison of volar versus dorsal screw fixation for scaphoid waist fractures: a finite element analysis","volume":"104","author":"Acar","year":"2018","journal-title":"Orthop Traumatol Surg Res"},{"key":"2026100205131803900_bib32","first-page":"73","article-title":"Single versus double screw fixation for the treatment of scaphoid waist fractures: finite element analysis and preliminary clinical results in scaphoid nonunion","volume":"31","author":"Acar","year":"2020","journal-title":"Jt Dis Relat Surg"},{"key":"2026100205131803900_bib33","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1007\/s43465-024-01156-w","article-title":"Finite element analysis of postoperative stability of transverse scaphoid waist fracture","volume":"58","author":"Srivastav","year":"2024","journal-title":"Indian J Orthop"},{"key":"2026100205131803900_bib34","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.medengphy.2015.11.006","article-title":"A finite element analysis of two novel screw designs for scaphoid waist fractures","volume":"38","author":"Varga","year":"2016","journal-title":"Med Eng Phys"},{"key":"2026100205131803900_bib35","doi-asserted-by":"crossref","first-page":"1246","DOI":"10.1016\/j.jhsa.2010.05.011","article-title":"Optimal fixation of acute scaphoid fractures: finite element analysis","volume":"35","author":"Luria","year":"2010","journal-title":"J Hand Surg Am"},{"key":"2026100205131803900_bib36","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1097\/01.blo.0000154204.72825.a5","article-title":"Does three-dimensional computer simulation improve results of scaphoid nonunion surgery?","volume":"434","author":"Murase","year":"2005","journal-title":"Clin Orthop Relat Res"},{"key":"2026100205131803900_bib37","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1177\/1753193410377837","article-title":"The length and position of the long axis of the scaphoid measured by analysis of three-dimensional reconstructions of computed tomography images","volume":"36","author":"Guo","year":"2011","journal-title":"J Hand Surg Eur Vol"},{"key":"2026100205131803900_bib38","doi-asserted-by":"crossref","first-page":"40","DOI":"10.3109\/2000656X.2010.541755","article-title":"Spatial measurement for safe placement of screws within the scaphoid using three-dimensional analysis","volume":"45","author":"Jung","year":"2011","journal-title":"J Plast Surg Hand Surg"},{"key":"2026100205131803900_bib39","doi-asserted-by":"crossref","first-page":"1183","DOI":"10.1016\/j.injury.2017.03.011","article-title":"Three-dimensional comparison of alternative screw positions versus actual fixation of scaphoid fractures","volume":"48","author":"Volk","year":"2017","journal-title":"Injury"},{"key":"2026100205131803900_bib40","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1016\/j.jhsa.2019.07.009","article-title":"Approach to the perpendicular fixation of a scaphoid waist Fracture-A computer analyzed cadaver model","volume":"45","author":"Luria","year":"2020","journal-title":"J Hand Surg Am"},{"key":"2026100205131803900_bib41","doi-asserted-by":"crossref","DOI":"10.1016\/j.compbiomed.2024.109163","article-title":"Multi-objective constraints for path planning in screw fixation of scaphoid fractures","volume":"182","author":"Xiao","year":"2024","journal-title":"Comput Biol Med"},{"key":"2026100205131803900_bib42","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1055\/s-0044-1779053","article-title":"Developing 3D-printed wrist splints for distal radius and scaphoid fractures","volume":"13","author":"Tobler-Ammann","year":"2024","journal-title":"J Wrist Surg"},{"key":"2026100205131803900_bib43","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1002\/rcs.194","article-title":"Kirschner wire placement in scaphoid bones using fluoroscopic navigation: a cadaver study comparing conventional techniques with navigation","volume":"4","author":"Liverneaux","year":"2008","journal-title":"Int J Med Robot"},{"key":"2026100205131803900_bib44","doi-asserted-by":"crossref","first-page":"280","DOI":"10.3109\/10929088.2011.621092","article-title":"Comparison of 2D and 3D navigation techniques for percutaneous screw insertion into the scaphoid: results of an experimental cadaver study","volume":"16","author":"Catala-Lehnen","year":"2011","journal-title":"Comput Aided Surg"},{"key":"2026100205131803900_bib45","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1002\/rcs.1572","article-title":"Percutaneous antegrade scaphoid screw placement: a feasibility and accuracy analysis of a novel electromagnetic navigation technique versus a standard fluoroscopic method","volume":"11","author":"Hoffmann","year":"2015","journal-title":"Int J Med Robot"},{"key":"2026100205131803900_bib46","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1007\/s10776-002-0623-6","article-title":"Computer-assisted orthopedic surgery","volume":"8","author":"Sugano","year":"2003","journal-title":"J Orthop Sci"},{"key":"2026100205131803900_bib47","doi-asserted-by":"crossref","first-page":"1722","DOI":"10.1016\/j.jhsa.2009.08.009","article-title":"Computer-assisted navigation of volar percutaneous scaphoid placement","volume":"34","author":"Walsh","year":"2009","journal-title":"J Hand Surg Am"},{"key":"2026100205131803900_bib48","doi-asserted-by":"crossref","first-page":"889","DOI":"10.1007\/s00402-010-1044-0","article-title":"Navigated scaphoid screw placement using customized scaphoid splint: an anatomical study","volume":"130","author":"Citak","year":"2010","journal-title":"Arch Orthop Trauma Surg"},{"key":"2026100205131803900_bib49","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1007\/s11548-011-0634-9","article-title":"Volume slicing of cone-beam computed tomography images for navigation of percutaneous scaphoid fixation","volume":"7","author":"Smith","year":"2012","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2026100205131803900_bib50","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1007\/s11548-012-0799-x","article-title":"Image guidance can support scaphoid K-wire insertion: an experimental study and initial clinical experience","volume":"8","author":"Scholl","year":"2013","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2026100205131803900_bib51","doi-asserted-by":"crossref","first-page":"613","DOI":"10.1016\/j.jhsa.2013.12.032","article-title":"Computer-assisted navigation for dorsal percutaneous scaphoid screw placement: a cadaveric study","volume":"39","author":"Kam","year":"2014","journal-title":"J Hand Surg Am"},{"key":"2026100205131803900_bib52","doi-asserted-by":"crossref","first-page":"165","DOI":"10.3109\/13645706.2012.724688","article-title":"Kirschner wire placement in scaphoid bones using intraoperative CT-guided stereotaxy","volume":"22","author":"Niederwanger","year":"2013","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"2026100205131803900_bib53","doi-asserted-by":"crossref","first-page":"941","DOI":"10.1007\/s11596-018-1968-0","article-title":"Computer-assisted surgery for scaphoid fracture","volume":"38","author":"Xiao","year":"2018","journal-title":"Curr Med Sci"},{"key":"2026100205131803900_bib54","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1177\/1753193419848595","article-title":"Robot-assisted percutaneous scaphoid fracture fixation: a report of ten patients","volume":"44","author":"Liu","year":"2019","journal-title":"J Hand Surg Eur Vol"},{"key":"2026100205131803900_bib55","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1016\/j.jhsa.2022.08.021","article-title":"A comparison between robotic-assisted scaphoid screw fixation and a freehand technique for acute scaphoid fracture: a randomized, controlled trial","volume":"47","author":"Guo","year":"2022","journal-title":"J Hand Surg Am"},{"key":"2026100205131803900_bib56","doi-asserted-by":"crossref","first-page":"839","DOI":"10.1007\/s00264-022-05532-9","article-title":"Robot-assisted vs traditional percutaneous freehand for the scaphoid fracture treatment: a retrospective study","volume":"47","author":"Xiao","year":"2022","journal-title":"Int Orthop"},{"key":"2026100205131803900_bib57","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1177\/17531934241292441","article-title":"Robot-assisted percutaneous scaphoid fixation: patient-reported outcomes and learning curve at two centres","volume":"50","author":"Yi","year":"2025","journal-title":"J Hand Surg Eur Vol"},{"key":"2026100205131803900_bib58","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1177\/1753193420944546","article-title":"Robot-assisted double screw fixation of minimally displaced scaphoid waist fracture nonunions or delayed unions without bone graft","volume":"46","author":"Guo","year":"2021","journal-title":"J Hand Surg Eur Vol"},{"key":"2026100205131803900_bib59","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1111\/os.13930","article-title":"Arthroscopic bone grafting and robot-assisted fixation for scaphoid nonunion","volume":"16","author":"Yi","year":"2024","journal-title":"Orthopaedic Surg"},{"key":"2026100205131803900_bib60","doi-asserted-by":"crossref","DOI":"10.1016\/j.eats.2025.103701","article-title":"Technique of carbon dioxide insufflation of the wrist during arthroscopic bone-grafting procedures","volume":"14","author":"Tan","year":"2025","journal-title":"Arthrosc Tech"},{"key":"2026100205131803900_bib61","doi-asserted-by":"crossref","DOI":"10.1177\/10225536251345192","article-title":"Pulsed CO(2)Gas arthroscopy combined with robot-navigated screw fixation and autologous iliac grafting for scaphoid nonunion","volume":"33","author":"Zhou","year":"2025","journal-title":"J Orthop Surg"},{"key":"2026100205131803900_bib62","doi-asserted-by":"crossref","first-page":"490","DOI":"10.1111\/os.13957","article-title":"A novel technique of arthroscopic-assisted four-corner fusion and robot-assisted fixation for scaphoid nonunion advanced collapse wrist: a single case study","volume":"16","author":"Gao","year":"2024","journal-title":"Orthopaedic Surg"},{"key":"2026100205131803900_bib63","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.1111\/os.13677","article-title":"A novel mini-invasive technique of arthroscopic-assisted reduction and robot-assisted fixation for trans-scaphoid perilunate fracture dislocations","volume":"15","author":"Yi","year":"2023","journal-title":"Orthopaedic Surg"},{"key":"2026100205131803900_bib64","doi-asserted-by":"crossref","first-page":"724","DOI":"10.1186\/s13018-024-05213-w","article-title":"Robot-assisted technique can achieve accurate screw placement in four-corner fusion and reduce operative difficulty: a cadaver study","volume":"19","author":"Wang","year":"2024","journal-title":"J Orthop Surg Res"},{"key":"2026100205131803900_bib65","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1007\/s00264-023-06013-3","article-title":"A comparative cadaveric study for percutaneous scaphoid fixation: robotic vs freehand","volume":"48","author":"Yin","year":"2024","journal-title":"Int Orthop"},{"key":"2026100205131803900_bib66","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1142\/S2424835523500479","article-title":"A cadaveric feasibility study of an automatic multi-degrees of freedom surgical robot for percutaneous scaphoid guide pin insertion","volume":"28","author":"Wang","year":"2023","journal-title":"J Hand Surg Asian Pac Vol"},{"key":"2026100205131803900_bib67","doi-asserted-by":"crossref","first-page":"1424","DOI":"10.1148\/rg.2017160165","article-title":"Measuring and establishing the accuracy and reproducibility of 3D printed medical models","volume":"37","author":"George","year":"2017","journal-title":"Radiographics"},{"key":"2026100205131803900_bib68","doi-asserted-by":"crossref","first-page":"22","DOI":"10.1142\/S2424835523500042","article-title":"A review of the use of 3D printing technology in treatment of scaphoid fractures","volume":"28","author":"Li","year":"2023","journal-title":"J Hand Surg Asian Pac Vol"},{"key":"2026100205131803900_bib69","doi-asserted-by":"crossref","first-page":"301.e1","DOI":"10.1016\/j.jhsa.2017.01.017","article-title":"3-Dimensional printing-assisted percutaneous fixation for acute scaphoid fracture: 1-shot procedure","volume":"42","author":"Yin","year":"2017","journal-title":"J Hand Surg Am"},{"key":"2026100205131803900_bib70","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1177\/1753193419851525","article-title":"Three-dimensional-printed patient-specific Kirschner-wire guide for percutaneous fixation of undisplaced scaphoid fractures: a cadaveric study","volume":"44","author":"Salabi","year":"2019","journal-title":"J Hand Surg Eur Vol"},{"key":"2026100205131803900_bib71","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1007\/s11596-019-2133-0","article-title":"Experimental study and preliminary clinical application of mini-invasive percutaneous internal screw fixation for scaphoid fracture under the guidance of a 3D-printed guide plate","volume":"39","author":"Wan","year":"2019","journal-title":"Curr Med Sci"},{"key":"2026100205131803900_bib72","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1177\/17531934211049132","article-title":"A customized percutaneous three-dimensional-printed guide for scaphoid fixation versus a freehand technique: a comparative study","volume":"46","author":"Marcano-Fern\u00e1ndez","year":"2021","journal-title":"J Hand Surg Eur Vol"},{"key":"2026100205131803900_bib73","first-page":"138","article-title":"3D printing-assisted percutaneous fixation makes the surgery for scaphoid nonunion more accurate and less invasive","volume":"24","author":"Yin","year":"2020","journal-title":"J Orthop Transl"},{"key":"2026100205131803900_bib74","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1177\/1558944720906502","article-title":"Three-dimensional printed targeting device for scaphoid fracture fixation","volume":"17","author":"DeWolf","year":"2022","journal-title":"Hand"},{"key":"2026100205131803900_bib75","doi-asserted-by":"crossref","first-page":"749","DOI":"10.52628\/88.4.8654","article-title":"The clinical application of individualized three-dimensional printing guiding template for assisting scaphoid fracture fixation through dorsal approach","volume":"88","author":"Lin","year":"2022","journal-title":"Acta Orthop Belg"},{"key":"2026100205131803900_bib76","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1186\/s12891-024-07243-1","article-title":"3D printed guide-assisted percutaneous screw fixation for minimally displaced scaphoid waist fractures with delayed diagnosis or presentation","volume":"25","author":"Rong","year":"2024","journal-title":"BMC Muscoskelet Disord"},{"key":"2026100205131803900_bib77","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1016\/j.jhsg.2024.11.008","article-title":"A patient-specific three-dimensional-printed surgical guide for dorsal scaphoid fracture fixation: a comparative cadaver study","volume":"7","author":"Wagner","year":"2025","journal-title":"J Hand Surg Glob Online"},{"key":"2026100205131803900_bib78","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.jhsa.2015.10.009","article-title":"Computer-assisted 3-dimensional reconstructions of scaphoid fractures and nonunions with and without the use of patient-specific guides: early clinical outcomes and postoperative assessments of reconstruction accuracy","volume":"41","author":"Schweizer","year":"2016","journal-title":"J Hand Surg Am"},{"key":"2026100205131803900_bib79","doi-asserted-by":"crossref","first-page":"2082","DOI":"10.3390\/jcm14062082","article-title":"Three-dimensional-planned patient-specific guides for scaphoid reconstruction: a comparative study of primary and revision nonunion cases","volume":"14","author":"Wirth","year":"2025","journal-title":"J Clin Med"},{"key":"2026100205131803900_bib80","doi-asserted-by":"crossref","first-page":"2900","DOI":"10.1016\/j.injury.2020.02.102","article-title":"3D printing for scaphoid-reconstruction with medial femoral condyle flap","volume":"51","author":"Schmidt","year":"2020","journal-title":"Injury"},{"key":"2026100205131803900_bib81","doi-asserted-by":"crossref","first-page":"165.e1","DOI":"10.1016\/j.jhsa.2018.10.018","article-title":"The use of three-dimensional printing for complex scaphoid fractures","volume":"44","author":"Jew","year":"2019","journal-title":"J Hand Surg Am"},{"key":"2026100205131803900_bib82","doi-asserted-by":"crossref","first-page":"e239548","DOI":"10.1136\/bcr-2020-239548","article-title":"Scaphoid non-union with pre-existing screws treated by 3D preoperative planning","volume":"14","author":"Oki","year":"2021","journal-title":"BMJ Case Rep"},{"key":"2026100205131803900_bib83","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1097\/BTH.0000000000000129","article-title":"Technique for 3-dimesional (3D) modeling of osteoarticular medial femoral condyle vascularized grafting to replace the proximal pole of unsalvagable scaphoid nonunions","volume":"20","author":"Houdek","year":"2016","journal-title":"Tech Hand Upper Extrem Surg"},{"key":"2026100205131803900_bib84","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1177\/1753193418757634","article-title":"A three-dimensional printed patient-specific scaphoid replacement: a cadaveric study","volume":"43","author":"Honigmann","year":"2018","journal-title":"J Hand Surg Eur Vol"},{"key":"2026100205131803900_bib85","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1080\/23320885.2019.1708203","article-title":"A case of total scaphoid titanium custom-made 3D-printed prostheses with one-year follow-up","volume":"7","author":"Rossello","year":"2020","journal-title":"Case Rep Plast Surg Hand Surg"},{"key":"2026100205131803900_bib86","doi-asserted-by":"crossref","DOI":"10.1155\/2021\/1301028","article-title":"In-Hospital 3D printed scaphoid prosthesis using medical-grade polyetheretherketone (PEEK) biomaterial","volume":"2021","author":"Honigmann","year":"2021","journal-title":"Biomed Res Int"},{"key":"2026100205131803900_bib87","doi-asserted-by":"crossref","first-page":"e241090","DOI":"10.1136\/bcr-2020-241090","article-title":"Short-term findings of a custom-made 3D-printed titanium partial scaphoid prosthesis and scapholunate interosseous ligament reconstruction","volume":"14","author":"Rossello","year":"2021","journal-title":"BMJ Case Rep"},{"key":"2026100205131803900_bib88","doi-asserted-by":"crossref","first-page":"3123","DOI":"10.3390\/healthcare11243123","article-title":"Treatment of scaphoid non-unions with custom-made 3D-printed titanium partial and total scaphoid prostheses and scaphoid interosseous ligament reconstruction","volume":"11","author":"Cioffi","year":"2023","journal-title":"Healthc"},{"key":"2026100205131803900_bib89","doi-asserted-by":"crossref","first-page":"e264761","DOI":"10.1136\/bcr-2024-264761","article-title":"Treatment of scapholunate advanced collapse by 3D-modelled scaphoid prostheses","volume":"18","author":"Kemler","year":"2025","journal-title":"BMJ Case Rep"},{"key":"2026100205131803900_bib90","first-page":"536","article-title":"Ultrasound-guided percutaneous scaphoid pinning: operator variability and comparison with traditional fluoroscopic procedure","volume":"9","author":"Beek","year":"2006","journal-title":"Med Image Comput Comput Assist Interv"},{"key":"2026100205131803900_bib91","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1097\/BTH.0000000000000353","article-title":"Mixed reality assisted percutaneous scaphoid fixation: a proposed new surgical technique","volume":"26","author":"Gregory","year":"2021","journal-title":"Tech Hand Up Extrem Surg"},{"key":"2026100205131803900_bib92","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.media.2007.08.003","article-title":"Validation of a new surgical procedure for percutaneous scaphoid fixation using intra-operative ultrasound","volume":"12","author":"Beek","year":"2008","journal-title":"Med Image Anal"},{"key":"2026100205131803900_bib93","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1007\/s11548-015-1181-6","article-title":"Bone enhancement in ultrasound using local spectrum variations for guiding percutaneous scaphoid fracture fixation procedures","volume":"10","author":"Anas","year":"2015","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2026100205131803900_bib94","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1007\/s11548-016-1370-y","article-title":"Registration of a statistical model to intraoperative ultrasound for scaphoid screw fixation","volume":"11","author":"Anas","year":"2016","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2026100205131803900_bib95","doi-asserted-by":"crossref","first-page":"1064","DOI":"10.1109\/TUFFC.2023.3291387","article-title":"Ultrasound-based registration for the computer-assisted navigated percutaneous scaphoid fixation","volume":"70","author":"Brosner","year":"2023","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"}],"container-title":["EFORT Open Reviews"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.bioscientifica.com\/eor\/article-pdf\/11\/10\/1048\/526084\/eor-2026-0084.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/journals.bioscientifica.com\/eor\/article-pdf\/11\/10\/1048\/526084\/eor-2026-0084.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,2]],"date-time":"2026-10-02T09:13:31Z","timestamp":1790932411000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.bioscientifica.com\/eor\/article\/11\/10\/1048\/78313\/A-review-of-digital-orthopedic-techniques-in-pre"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,1]]},"references-count":95,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2026,10,1]]},"published-print":{"date-parts":[[2026,10,1]]}},"URL":"https:\/\/doi.org\/10.1530\/eor-2026-0084","relation":{},"ISSN":["2058-5241"],"issn-type":[{"value":"2058-5241","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,1]]}}}