{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T07:04:26Z","timestamp":1789542266490,"version":"build-2803163510"},"reference-count":119,"publisher":"Bioscientifica","issue":"4","license":[{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"content-domain":{"domain":["eor.bioscientifica.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,4,1]]},"abstract":"<jats:sec>\n                    <jats:title>Purpose<\/jats:title>\n                    <jats:list list-type=\"bullet\">\n                      <jats:list-item>\n                        <jats:p>The aim of the study was to assess the role of kyphoplasty and expandable intravertebral implants in the treatment of traumatic vertebral compression fractures.<\/jats:p>\n                      <\/jats:list-item>\n                    <\/jats:list>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Design<\/jats:title>\n                    <jats:list list-type=\"bullet\">\n                      <jats:list-item>\n                        <jats:p>This is a systematic review.<\/jats:p>\n                      <\/jats:list-item>\n                    <\/jats:list>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:list list-type=\"bullet\">\n                      <jats:list-item>\n                        <jats:p>A bibliographic search was carried out in the PubMed\/MEDLINE database according to PRISMA guidelines regarding kyphoplasty and expandable intravertebral implants in the treatment of traumatic thoracolumbar vertebral fractures.<\/jats:p>\n                      <\/jats:list-item>\n                    <\/jats:list>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:list list-type=\"bullet\">\n                      <jats:list-item>\n                        <jats:p>A total of 611 records were screened. In total, 51 studies were obtained referring to traumatic vertebral fractures treated with kyphoplasty; however, of these, only studies addressing traumatic burst fractures were selected, resulting in 12 studies: 10 about kyphoplasty and 2 regarding armed kyphoplasty. In all studies, there was a statistically significant improvement in clinical and functional parameters, restoration of vertebral height and decreasing of vertebral and segmental kyphosis. Overall, there was only a residual loss of height and a slight increase in kyphosis throughout the follow-up period, while complications consisted essentially of cement leakage, all with no clinical repercussions.<\/jats:p>\n                      <\/jats:list-item>\n                    <\/jats:list>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:list list-type=\"bullet\">\n                      <jats:list-item>\n                        <jats:p>After the discussion, where we address the concepts of direct and indirect reduction, the association of kyphoplasty with pedicle fixation, the potential advantages of expandable intravertebral implants, as well as the vertebral body type of filling in kyphoplasty, it is concluded that kyphoplasty demonstrates favorable outcomes as a method of posterior percutaneous transpedicular access for reconstruction of the anterior column in burst fractures. It allows for the reconstruction of the vertebral body closer to its original anatomy, carried out in a minimally invasive and safe way, which provides a clinical-functional and imaging improvement maintained at the medium\u2013long term.<\/jats:p>\n                      <\/jats:list-item>\n                    <\/jats:list>\n                  <\/jats:sec>","DOI":"10.1530\/eor-23-0190","type":"journal-article","created":{"date-parts":[[2024,4,4]],"date-time":"2024-04-04T08:31:47Z","timestamp":1712219507000},"page":"309-322","update-policy":"https:\/\/doi.org\/10.1530\/crossmarkpolicy-16","source":"Crossref","is-referenced-by-count":8,"title":["The role of kyphoplasty and expandable intravertebral implants in the acute treatment of traumatic thoracolumbar vertebral compression fractures: a systematic review"],"prefix":"10.1530","volume":"9","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4037-2442","authenticated-orcid":true,"given":"Diogo Lino","family":"Moura","sequence":"first","affiliation":[{"name":"Spine Unit, Department of Orthopedics, Coimbra University Hospital, Coimbra, Portugal, Coimbra, Portugal"},{"name":"Anatomy Institute and Orthopedics Department, Faculty of Medicine, University of Coimbra, Coimbra, Portugal"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"416","reference":[{"key":"bib1","series-title":"BioMed Research International","first-page":"434873","article-title":"Percutaneous dorsal instrumentation of vertebral burst fractures value of additional percutaneous intravertebral reposition-cadaver study","volume":"2015","author":"Kr\u00fcger","year":"2015","unstructured":"Kr\u00fcger ASchmuck MNoriega DCRuchholtz SBaroud G & Oberkircher L. Percutaneous dorsal instrumentation of vertebral burst fractures value of additional percutaneous intravertebral reposition-cadaver study. BioMed Research International20152015434873\u2013434873. (https:\/\/doi.org\/10.1155\/2015\/434873)"},{"key":"bib2","series-title":"Spine","first-page":"543","article-title":"Balloon vertebroplasty with calcium phosphate cement augmentation for direct restoration of traumatic thoracolumbar vertebral fractures","volume":"27","author":"Verlaan","year":"2002","unstructured":"Verlaan JJvan Helden WHOner FCVerbout AJ & Dhert WJA. Balloon vertebroplasty with calcium phosphate cement augmentation for direct restoration of traumatic thoracolumbar vertebral fractures. Spine200227543\u2013548. (https:\/\/doi.org\/10.1097\/00007632-200203010-00021)"},{"key":"bib3","series-title":"Spine","first-page":"E100","article-title":"Direct reduction of thoracolumbar burst fractures by means of balloon kyphoplasty with calcium phosphate and stabilization with pedicle-screw instrumentation and fusion","volume":"33","author":"Korovessis","year":"2008","unstructured":"Korovessis PRepantis TPetsinis GIliopoulos P & Hadjipavlou A. Direct reduction of thoracolumbar burst fractures by means of balloon kyphoplasty with calcium phosphate and stabilization with pedicle-screw instrumentation and fusion. Spine200833E100\u2013E108. (https:\/\/doi.org\/10.1097\/BRS.0b013e3181646b07)"},{"key":"bib4","series-title":"Der Unfallchirurg","first-page":"197","article-title":"Transpedicular repositioning and spongioplasty in fractures of the vertebral bodies of the lower thoracic and lumbar spine","volume":"89","author":"Daniaux","year":"1986","unstructured":"Daniaux H. Transpedicular repositioning and spongioplasty in fractures of the vertebral bodies of the lower thoracic and lumbar spine. Der Unfallchirurg198689197\u2013213."},{"issue":"Supplement 1 Pt 1","key":"bib5","series-title":"Journal of Bone and Joint Surgery","first-page":"67","article-title":"Thoracolumbar burst fractures treated with posterior decompression and pedicle screw instrumentation supplemented with balloon-assisted vertebroplasty and calcium phosphate reconstruction. Surgical technique","volume":"92","author":"Marco","year":"2010","unstructured":"Marco RAMeyer BC & Kushwaha VP. Thoracolumbar burst fractures treated with posterior decompression and pedicle screw instrumentation supplemented with balloon-assisted vertebroplasty and calcium phosphate reconstruction. Surgical technique. Journal of Bone and Joint Surgery201092(Supplement 1 Pt 1) 67\u201376. (https:\/\/doi.org\/10.2106\/JBJS.I.01236)"},{"key":"bib6","series-title":"Spine Journal","first-page":"1172","article-title":"Clinical and radiological results 6 years after treatment of traumatic thoracolumbar burst fractures with pedicle screw instrumentation and balloon assisted endplate reduction","volume":"15","author":"Verlaan","year":"2015","unstructured":"Verlaan JJSomers IDhert WJA & Oner FC. Clinical and radiological results 6 years after treatment of traumatic thoracolumbar burst fractures with pedicle screw instrumentation and balloon assisted endplate reduction. Spine Journal2015151172\u20131178. (https:\/\/doi.org\/10.1016\/j.spinee.2013.11.044)"},{"key":"bib7","series-title":"Journal of Orthopaedic Trauma","first-page":"499","article-title":"Transpedicular instrumentation and short-segment fusion of thoracolumbar fractures: a prospective study using a single instrumentation system","volume":"9","author":"Kramer","year":"1995","unstructured":"Kramer DLRodgers WB & Mansfield FL. Transpedicular instrumentation and short-segment fusion of thoracolumbar fractures: a prospective study using a single instrumentation system. Journal of Orthopaedic Trauma19959499\u2013506. (https:\/\/doi.org\/10.1097\/00005131-199509060-00007)"},{"key":"bib8","series-title":"Spine","first-page":"1157","article-title":"Successful short-segment instrumentation and fusion for thoracolumbar spine fractures: a consecutive 41\/2-year series","volume":"25","author":"Parker","year":"2000","unstructured":"Parker JWLane JRKaraikovic EE & Gaines RW. Successful short-segment instrumentation and fusion for thoracolumbar spine fractures: a consecutive 41\/2-year series. Spine2000251157\u20131170. (https:\/\/doi.org\/10.1097\/00007632-200005010-00018)"},{"key":"bib9","series-title":"Acta Orthopaedica Scandinavica","first-page":"406","article-title":"Recurrent kyphosis after posterior stabilisation of thoracolumbar fractures: 24 cases treated with a Dick internal fixator followed for 1.5 to 4 years","volume":"66","author":"Speth","year":"1995","unstructured":"Speth MJOner FCKadic MAde Klerk LW & Verbout AJ. Recurrent kyphosis after posterior stabilisation of thoracolumbar fractures: 24 cases treated with a Dick internal fixator followed for 1.5 to 4 years. Acta Orthopaedica Scandinavica199566406\u2013410. (https:\/\/doi.org\/10.3109\/17453679508995575)"},{"key":"bib10","series-title":"Spine","first-page":"1741","article-title":"The load sharing classification of spine fractures","volume":"19","author":"McCormack","year":"1994","unstructured":"McCormack TKaraikovic E & Gaines RW. The load sharing classification of spine fractures. Spine1994191741\u20131744. (https:\/\/doi.org\/10.1097\/00007632-199408000-00014)"},{"key":"bib11","series-title":"European Spine Journal","first-page":"214","article-title":"Complications in surgical treatment of thoracolumbar injuries","volume":"11","author":"Knop","year":"2002","unstructured":"Knop CBastian LLange UOeser MZdichavsky M & Blauth M. Complications in surgical treatment of thoracolumbar injuries. European Spine Journal200211214\u2013226. (https:\/\/doi.org\/10.1007\/s00586-001-0382-6)"},{"key":"bib12","series-title":"Spine","first-page":"E73","article-title":"Balloon vertebroplasty in combination with pedicle screw instrumentation: a novel technique to treat thoracic and lumbar burst fractures","volume":"30","author":"Verlaan","year":"2005","unstructured":"Verlaan JJDhert WJVerbout AJ & Oner FC. Balloon vertebroplasty in combination with pedicle screw instrumentation: a novel technique to treat thoracic and lumbar burst fractures. Spine200530E73\u2013E79. (https:\/\/doi.org\/10.1097\/01.brs.0000152162.64015.fb)"},{"key":"bib13","series-title":"Acta Neurochirurgica (Wien)","first-page":"349","article-title":"Comparison of two types of surgery for thoracolumbar burst fractures: combined anterior and posterior stabilisation vs. posterior instrumentation only","volume":"141","author":"Been","year":"1999","unstructured":"Been HD & Bouma GJ. Comparison of two types of surgery for thoracolumbar burst fractures: combined anterior and posterior stabilisation vs. posterior instrumentation only. Acta Neurochirurgica (Wien)1999141349\u2013357. (https:\/\/doi.org\/10.1007\/s007010050310)"},{"key":"bib14","series-title":"Der Unfallchirurg","first-page":"1032","article-title":"Surgical treatment of injuries of the thoracolumbar transition. 2: operation and roentgenologic findings","volume":"103","author":"Knop","year":"2000","unstructured":"Knop CBlauth MBuhren VHax PMKinzl LMutschler WPommer AUlrich CWagner SWeckbach A, et al.Surgical treatment of injuries of the thoracolumbar transition. 2: operation and roentgenologic findings. Der Unfallchirurg20001031032\u20131047. (https:\/\/doi.org\/10.1007\/s001130050667)"},{"key":"bib15","series-title":"Spine","first-page":"686","article-title":"Anterolateral dynamized instrumentation and fusion for unstable thoracolumbar and lumbar burst fractures","volume":"22","author":"Carl","year":"1997","unstructured":"Carl ALTranmer BI & Sachs BL. Anterolateral dynamized instrumentation and fusion for unstable thoracolumbar and lumbar burst fractures. Spine199722686\u2013690. (https:\/\/doi.org\/10.1097\/00007632-199703150-00022)"},{"key":"bib16","series-title":"Journal of Spinal Disorders","first-page":"335","article-title":"Unstable thoracolumbar and lumbar burst fractures treated with the AO fixateur interne","volume":"5","author":"Benson","year":"1992","unstructured":"Benson DRBurkus JKMontesano PXSutherland TB & McLain RF. Unstable thoracolumbar and lumbar burst fractures treated with the AO fixateur interne. Journal of Spinal Disorders19925335\u2013343. (https:\/\/doi.org\/10.1097\/00002517-199209000-00012)"},{"key":"bib17","series-title":"Journal of Bone and Joint Surgery","first-page":"162","article-title":"Early failure of short-segment pedicle instrumentation for thoracolumbar fractures: a preliminary report","volume":"75","author":"McLain","year":"1993","unstructured":"McLain RFSparling E & Benson DR. Early failure of short-segment pedicle instrumentation for thoracolumbar fractures: a preliminary report. Journal of Bone and Joint Surgery199375162\u2013167. (https:\/\/doi.org\/10.2106\/00004623-199302000-00002)"},{"key":"bib18","series-title":"Spine","first-page":"803","article-title":"Surgical treatment of traumatic fractures of the thoracic and lumbar spine: a systematic review of the literature on techniques, complications, and outcome","volume":"29","author":"Verlaan","year":"2004","unstructured":"Verlaan JJDiekerhof CHBuskens Evan der Tweel IVerbout AJDhert WJ & Oner FC. Surgical treatment of traumatic fractures of the thoracic and lumbar spine: a systematic review of the literature on techniques, complications, and outcome. Spine200429803\u2013814. (https:\/\/doi.org\/10.1097\/01.brs.0000116990.31984.a9)"},{"issue":"Supplement 1","key":"bib19","series-title":"European Spine Journal","first-page":"71","article-title":"Minimally invasive percutaneous fixation in the treatment of thoracic and lumbar spine fractures","volume":"18","author":"Palmisani","year":"2009","unstructured":"Palmisani MGasbarrini ABrodano GBDe Iure FCappuccio MBoriani LAmendola L & Boriani S. Minimally invasive percutaneous fixation in the treatment of thoracic and lumbar spine fractures. European Spine Journal200918(Supplement 1) 71\u201374. (https:\/\/doi.org\/10.1007\/s00586-009-0989-6)"},{"key":"bib20","series-title":"Journal of Spinal Disorders","first-page":"402","article-title":"A biomechanical comparison evaluating the use of intermediate screws and cross-linkage in lumbar pedicle fixation","volume":"7","author":"Dick","year":"1994","unstructured":"Dick JCJones MPZdeblick TAKunz DN & Horton WC. A biomechanical comparison evaluating the use of intermediate screws and cross-linkage in lumbar pedicle fixation. Journal of Spinal Disorders19947402\u2013407. (https:\/\/doi.org\/10.1097\/00002517-199410000-00006)"},{"key":"bib21","series-title":"Medicine","first-page":"e4574","article-title":"Pedicle screw fixation combined with intermediate screw at the fracture level for treatment of thoracolumbar fractures: a meta-analysis","volume":"95","author":"Li","year":"2016","unstructured":"Li KZhang WLiu DXu HGeng WLuo D & Ma J. Pedicle screw fixation combined with intermediate screw at the fracture level for treatment of thoracolumbar fractures: a meta-analysis. Medicine201695e4574. (https:\/\/doi.org\/10.1097\/MD.0000000000004574)"},{"key":"bib22","series-title":"International Journal of Surgery","first-page":"38","article-title":"Combined pedicle screw fixation at the fracture vertebrae versus conventional method for thoracolumbar fractures: a meta-analysis","volume":"53","author":"Zhang","year":"2018","unstructured":"Zhang C & Liu Y. Combined pedicle screw fixation at the fracture vertebrae versus conventional method for thoracolumbar fractures: a meta-analysis. International Journal of Surgery20185338\u201347. (https:\/\/doi.org\/10.1016\/j.ijsu.2018.03.002)"},{"key":"bib23","series-title":"World Neurosurgery","first-page":"e271","article-title":"Efficacy of using intermediate screws in short-segment fixation for thoracolumbar fractures: a meta-analysis of randomized controlled trials","volume":"110","author":"Tong","year":"2018","unstructured":"Tong MJTang QWang CGXiang GHChen QXu HZ & Tian NF. Efficacy of using intermediate screws in short-segment fixation for thoracolumbar fractures: a meta-analysis of randomized controlled trials. World Neurosurgery2018110e271\u2013e280. (https:\/\/doi.org\/10.1016\/j.wneu.2017.10.157)"},{"key":"bib24","series-title":"Injury","first-page":"2579","article-title":"Comparison of different segments in the fixation of thoracolumbar fractures: a Bayesian network meta-analysis","volume":"53","author":"Ma","year":"2022","unstructured":"Ma MDong HYu HRuan BXu XTao YWang YGu J. Comparison of different segments in the fixation of thoracolumbar fractures: a Bayesian network meta-analysis. Injury2022532579\u20132587."},{"key":"bib25","series-title":"European Spine Journal","first-page":"2491","article-title":"Pedicle screw fixation of thoracolumbar fractures: conventional short segment versus short segment with intermediate screws at the fracture level-a systematic review and meta-analysis","volume":"29","author":"Kapoen","year":"2020","unstructured":"Kapoen CLiu YBloemers FW & Deunk J. Pedicle screw fixation of thoracolumbar fractures: conventional short segment versus short segment with intermediate screws at the fracture level-a systematic review and meta-analysis. European Spine Journal2020292491\u20132504. (https:\/\/doi.org\/10.1007\/s00586-020-06479-4)"},{"key":"bib26","series-title":"Spine","first-page":"1503","article-title":"Short-segment fixation of lumbar burst fractures using pedicle fixation at the level of the fracture","volume":"32","author":"Mahar","year":"2007","unstructured":"Mahar AKim CWedemeyer MMitsunaga LOdell TJohnson B & Garfin S. Short-segment fixation of lumbar burst fractures using pedicle fixation at the level of the fracture. Spine2007321503\u20131507. (https:\/\/doi.org\/10.1097\/BRS.0b013e318067dd24)"},{"key":"bib27","series-title":"Spine","first-page":"664","article-title":"Reinforcement of thoracolumbar burst fractures with calcium phosphate cement. A biomechanical study","volume":"23","author":"Mermelstein","year":"1998","unstructured":"Mermelstein LEMcLain RF & Yerby SA. Reinforcement of thoracolumbar burst fractures with calcium phosphate cement. A biomechanical study. Spine199823664\u2013670. (https:\/\/doi.org\/10.1097\/00007632-199803150-00004)"},{"key":"bib28","series-title":"Injury","first-page":"1038","article-title":"Early results after vertebral body stenting for fractures of the anterior column of the thoracolumbar spine","volume":"42","author":"Klezl","year":"2011","unstructured":"Klezl ZMajeed HBommireddy R & John J. Early results after vertebral body stenting for fractures of the anterior column of the thoracolumbar spine. Injury2011421038\u20131042. (https:\/\/doi.org\/10.1016\/j.injury.2011.04.006)"},{"key":"bib29","series-title":"European Spine Journal","first-page":"916","article-title":"Verteb","volume":"19","author":"Rotter","year":"2010","unstructured":"Rotter RMartin HFuerderer SGabl MRoeder CHeini P & Mittlmeier T. Vertebral body stenting a new method for vertebral augmentation versus kyphoplasty. European Spine Journal201019916\u2013923. (https:\/\/doi.org\/10.1007\/s00586-010-1341-x)"},{"key":"bib30","series-title":"Journal of Craniovertebral Junction and Spine","first-page":"47","article-title":"New perspective for third generation percutaneous vertebral augmentation procedures preliminary results at 12 months","volume":"3","author":"Vanni","year":"2012","unstructured":"Vanni DPantalone ABigossi FPineto FLucantoni D & Salini V. New perspective for third generation percutaneous vertebral augmentation procedures preliminary results at 12 months. Journal of Craniovertebral Junction and Spine2012347\u201351. (https:\/\/doi.org\/10.4103\/0974-8237.116537)"},{"key":"bib31","series-title":"Journal of Neurosurgical Sciences","first-page":"13","article-title":"Efficacy of treatment with percutaneous vertebroplasty and kyphoplasty for traumatic fracture of thoracolumbar junction","volume":"53","author":"Costa","year":"2009","unstructured":"Costa FOrtolina ACardia ASassi MDe Santis ABorroni MSavoia G & Fornari M. Efficacy of treatment with percutaneous vertebroplasty and kyphoplasty for traumatic fracture of thoracolumbar junction. Journal of Neurosurgical Sciences20095313\u201317."},{"key":"bib32","series-title":"Neurosurgery","first-page":"1354","article-title":"Treatment of thoracolumbar burst fractures with polymethyl methacrylate vertebroplasty and short-segment pedicle screw fixation","volume":"53","author":"Cho","year":"2003","unstructured":"Cho DYLee WY & Sheu PC. Treatment of thoracolumbar burst fractures with polymethyl methacrylate vertebroplasty and short-segment pedicle screw fixation. Neurosurgery2003531354\u20131361. (https:\/\/doi.org\/10.1227\/01.neu.0000093200.74828.2f)"},{"key":"bib33","series-title":"European Spine Journal","first-page":"1826","article-title":"Comparing effects of kyphoplasty, vertebroplasty, and non-surgical management in a systematic review of randomized and non-randomized controlled studies","volume":"21","author":"Papanastassiou","year":"2012","unstructured":"Papanastassiou IDPhillips FMVan Meirhaeghe JBerenson JRAndersson GBChung GSmall BJAghayev K & Vrionis FD. Comparing effects of kyphoplasty, vertebroplasty, and non-surgical management in a systematic review of randomized and non-randomized controlled studies. European Spine Journal2012211826\u20131843. (https:\/\/doi.org\/10.1007\/s00586-012-2314-z)"},{"key":"bib34","series-title":"Medicina","first-page":"426","article-title":"Innovative spine implants for improved augmentation and stability in neoplastic vertebral compression fracture","volume":"55","author":"Cornelis","year":"2019","unstructured":"Cornelis FHJoly QNouri-Neuville MBen-Ammar MKastler BKastler AAmoretti N & Hauger O. Innovative spine implants for improved augmentation and stability in neoplastic vertebral compression fracture. Medicina201955426. (https:\/\/doi.org\/10.3390\/medicina55080426)"},{"key":"bib35","series-title":"Spine Journal","first-page":"501","article-title":"Vertebroplasty and kyphoplasty for the treatment of vertebral compression fractures: an evidenced-based review of the literature","volume":"9","author":"McGirt","year":"2009","unstructured":"McGirt MJParker SLWolinsky JPWitham TFBydon A & Gokaslan ZL. Vertebroplasty and kyphoplasty for the treatment of vertebral compression fractures: an evidenced-based review of the literature. Spine Journal20099501\u2013508. (https:\/\/doi.org\/10.1016\/j.spinee.2009.01.003)"},{"key":"bib36","series-title":"Journal of Spine Surgery","first-page":"13","article-title":"Third-generation percutaneous vertebral augmentation systems","volume":"2","author":"Vanni","year":"2016","unstructured":"Vanni DGalzio RKazakova APantalone AGrillea GBartolo MSalini V & Magliani V. Third-generation percutaneous vertebral augmentation systems. Journal of Spine Surgery2016213\u201320. (https:\/\/doi.org\/10.21037\/jss.2016.02.01)"},{"key":"bib37","series-title":"European Spine Journal","first-page":"1281","article-title":"Percutaneous kyphoplasty and pedicle screw fixation for the management of thoraco-lumbar burst fractures","volume":"19","author":"Fuentes","year":"2010","unstructured":"Fuentes SBlondel BMetellus PGaudart JAdetchessi T & Dufour H. Percutaneous kyphoplasty and pedicle screw fixation for the management of thoraco-lumbar burst fractures. European Spine Journal2010191281\u20131287. (https:\/\/doi.org\/10.1007\/s00586-010-1444-4)"},{"issue":"Supplement 2","key":"bib38","series-title":"Injury","first-page":"B82","article-title":"Less invasive anterior column reconstruction in thoracolumbar fractures","volume":"36","author":"Oner","year":"2005","unstructured":"Oner FCDhert WJ & Verlaan JJ. Less invasive anterior column reconstruction in thoracolumbar fractures. Injury200536(Supplement 2) B82\u2013B89. (https:\/\/doi.org\/10.1016\/j.injury.2005.06.018)"},{"key":"bib39","series-title":"Neurosurgical Focus","first-page":"e5","article-title":"Immediate and early postoperative pain relief after kyphoplasty without significant restoration of vertebral body height in acute osteoporotic vertebral fractures","volume":"18","author":"Feltes","year":"2005","unstructured":"Feltes CFountas KNMachinis TNikolakakos LGDimopoulos VDavydov RKassam MJohnston KW & Robinson JS. Immediate and early postoperative pain relief after kyphoplasty without significant restoration of vertebral body height in acute osteoporotic vertebral fractures. Neurosurgical Focus200518e5. (https:\/\/doi.org\/10.3171\/foc.2005.18.3.6)"},{"key":"bib40","series-title":"Spine","first-page":"1840","article-title":"The reduction of endplate fractures during balloon vertebroplasty: a detailed radiological analysis of the treatment of burst fractures using pedicle screws, balloon vertebroplasty, and calcium phosphate cement","volume":"30","author":"Verlaan","year":"2005","unstructured":"Verlaan JJvan de Kraats EBOner FCvan Walsum TNiessen WJ & Dhert WJ. The reduction of endplate fractures during balloon vertebroplasty: a detailed radiological analysis of the treatment of burst fractures using pedicle screws, balloon vertebroplasty, and calcium phosphate cement. Spine2005301840\u20131845. (https:\/\/doi.org\/10.1097\/01.brs.0000173895.19334.e2)"},{"key":"bib41","series-title":"Neuroradiology Journal","first-page":"610","article-title":"Vertebral body stenting system for the treatment of osteoporotic vertebral compression fracture: follow-up at 12 months in 20 cases","volume":"24","author":"Muto","year":"2011","unstructured":"Muto MGreco BSetola FVassallo PAmbrosanio G & Guarnieri G. Vertebral body stenting system for the treatment of osteoporotic vertebral compression fracture: follow-up at 12 months in 20 cases. Neuroradiology Journal201124610\u2013619. (https:\/\/doi.org\/10.1177\/197140091102400418)"},{"key":"bib42","series-title":"Clinical Biomechanics","first-page":"720","article-title":"Minimum cement volume required in vertebral body augmentation--a biomechanical study comparing the permanent SpineJack device and balloon kyphoplasty in traumatic fracture","volume":"30","author":"Rotter","year":"2015","unstructured":"Rotter RSchmitt LGierer PSchmitz KPNoriega DMittlmeier TMeeder PJ & Martin H. Minimum cement volume required in vertebral body augmentation--a biomechanical study comparing the permanent SpineJack device and balloon kyphoplasty in traumatic fracture. Clinical Biomechanics201530720\u2013725. (https:\/\/doi.org\/10.1016\/j.clinbiomech.2015.04.015)"},{"key":"bib43","series-title":"Clinical Biomechanics","first-page":"725","article-title":"Height restoration and maintenance after treating unstable osteoporotic vertebral compression fractures by cement augmentation is dependent on the cement volume used","volume":"28","author":"Kr\u00fcger","year":"2013","unstructured":"Kr\u00fcger ABaroud GNoriega DFigiel JDorschel CRuchholtz S & Oberkircher L. Height restoration and maintenance after treating unstable osteoporotic vertebral compression fractures by cement augmentation is dependent on the cement volume used. Clinical Biomechanics201328725\u2013730. (https:\/\/doi.org\/10.1016\/j.clinbiomech.2013.06.007)"},{"key":"bib44","series-title":"Spine","first-page":"2806","article-title":"Balloon kyphoplasty is effective in deformity correction of osteoporotic vertebral compression fractures","volume":"30","author":"Voggenreiter","year":"2005","unstructured":"Voggenreiter G. Balloon kyphoplasty is effective in deformity correction of osteoporotic vertebral compression fractures. Spine2005302806\u20132812. (https:\/\/doi.org\/10.1097\/01.brs.0000190885.85675.a0)"},{"key":"bib45","series-title":"Orthopaedics and Traumatology, Surgery and Research","first-page":"389","article-title":"Percutaneous internal fixation combined with kyphoplasty for neurologically intact thoracolumbar fractures: a prospective cohort study of 24 patients with one year of follow-up","volume":"97","author":"Bironneau","year":"2011","unstructured":"Bironneau ABouquet CMillet-Barbe BLeclercq NPries P & Gayet LE. Percutaneous internal fixation combined with kyphoplasty for neurologically intact thoracolumbar fractures: a prospective cohort study of 24 patients with one year of follow-up. Orthopaedics and Traumatology, Surgery and Research201197389\u2013395. (https:\/\/doi.org\/10.1016\/j.otsr.2011.02.009)"},{"key":"bib46","series-title":"Injury","first-page":"409","article-title":"Kyphoplasty as an alternative treatment of traumatic thoracolumbar burst fractures Magerl type A3","volume":"43","author":"Hartmann","year":"2012","unstructured":"Hartmann FGercek ELeiner L & Rommens PM. Kyphoplasty as an alternative treatment of traumatic thoracolumbar burst fractures Magerl type A3. Injury201243409\u2013415. (https:\/\/doi.org\/10.1016\/j.injury.2010.03.025)"},{"issue":"Supplement 1","key":"bib47","series-title":"European Spine Journal","first-page":"S108","article-title":"Treatment of typical amyelic somatic fractures with kyphoplasty and calcium phosphate cement: a critical analysis","volume":"21","author":"Gioia","year":"2012","unstructured":"Gioia GMandelli D & Gogue R. Treatment of typical amyelic somatic fractures with kyphoplasty and calcium phosphate cement: a critical analysis. European Spine Journal201221(Supplement 1) S108\u2013S111. (https:\/\/doi.org\/10.1007\/s00586-012-2225-z)"},{"issue":"Supplement","key":"bib48","series-title":"Spine","first-page":"S89","article-title":"Cement augmentation techniques in traumatic thoracolumbar spine fractures","volume":"31","author":"Oner","year":"2006","unstructured":"Oner FCVerlaan JJVerbout AJ & Dhert WJA. Cement augmentation techniques in traumatic thoracolumbar spine fractures. Spine200631(Supplement) S89\u2013S104. (https:\/\/doi.org\/10.1097\/01.brs.0000217950.60516.e6)"},{"key":"bib49","series-title":"Spine","first-page":"E1147","article-title":"Cement augmentation in a thoracolumbar fracture model: reduction and stability after balloon kyphoplasty versus vertebral body stenting","volume":"39","author":"Disch","year":"2014","unstructured":"Disch AC & Schmoelz W. Cement augmentation in a thoracolumbar fracture model: reduction and stability after balloon kyphoplasty versus vertebral body stenting. Spine201439E1147\u2013E1153. (https:\/\/doi.org\/10.1097\/BRS.0000000000000470)"},{"key":"bib50","series-title":"Acta Ortop\u00e9dica Brasileira","first-page":"e245117","article-title":"Intravertebral expandable implants in thoracolumbar vertebral compression fractures","volume":"30","author":"Moura","year":"2022","unstructured":"Moura DFL & Gabriel JP. Intravertebral expandable implants in thoracolumbar vertebral compression fractures. Acta Ortop\u00e9dica Brasileira202230e245117. (https:\/\/doi.org\/10.1590\/1413-785220223003e245117)"},{"key":"bib51","series-title":"Cureus","first-page":"e17795","article-title":"Expandable intravertebral implants: a narrative review on the concept, biomechanics, and outcomes in traumatology","volume":"13","author":"Moura","year":"2021","unstructured":"Moura DL & Gabriel JP. Expandable intravertebral implants: a narrative review on the concept, biomechanics, and outcomes in traumatology. Cureus202113e17795. (https:\/\/doi.org\/10.7759\/cureus.17795)"},{"key":"bib52","series-title":"Minimally Invasive Therapy and Allied Technologies","first-page":"161","article-title":"Two-year results of vertebral body stenting for the treatment of traumatic incomplete burst fractures","volume":"24","author":"Hartmann","year":"2015","unstructured":"Hartmann FGriese MDietz SOKuhn SRommens PM & Gercek E. Two-year results of vertebral body stenting for the treatment of traumatic incomplete burst fractures. Minimally Invasive Therapy and Allied Technologies201524161\u2013166. (https:\/\/doi.org\/10.3109\/13645706.2014.962546)"},{"key":"bib53","series-title":"BMC Musculoskeletal Disorders","first-page":"233","article-title":"Radiographic and safety details of vertebral body stenting results from a multicenter chart review","volume":"14","author":"Diel","year":"2013","unstructured":"Diel PR\u00f6der CPerler GVordemvenne TScholz MKandziora FF\u00fcrderer SEiskjaer SMaestretti GRotter R, et al.Radiographic and safety details of vertebral body stenting results from a multicenter chart review. BMC Musculoskeletal Disorders201314233\u2013233. (https:\/\/doi.org\/10.1186\/1471-2474-14-233)"},{"key":"bib54","series-title":"European Spine Journal","first-page":"1608","article-title":"Surgical procedure and initial radiographic results of a new augmentation technique for vertebral compression fractures","volume":"22","author":"Thaler","year":"2013","unstructured":"Thaler MLechner RNogler MGst\u00f6ttner M & Bach C. Surgical procedure and initial radiographic results of a new augmentation technique for vertebral compression fractures. European Spine Journal2013221608\u20131616. (https:\/\/doi.org\/10.1007\/s00586-012-2603-6)"},{"key":"bib55","series-title":"Journal of Bone and Joint Surgery","first-page":"577","article-title":"Vertebral body stenting versus kyphoplasty for the treatment of osteoporotic vertebral compression fractures a randomized trial","volume":"95","author":"Werner","year":"2013","unstructured":"Werner CMOsterhoff GSchlickeiser JJenni RWanner GAOssendorf C & Simmen HP. Vertebral body stenting versus kyphoplasty for the treatment of osteoporotic vertebral compression fractures a randomized trial. Journal of Bone and Joint Surgery201395577\u2013584. (https:\/\/doi.org\/10.2106\/JBJS.L.00024)"},{"key":"bib56","series-title":"World Neurosurgery","first-page":"391","article-title":"Better height restoration, greater kyphosis correction, and fewer refractures of cemented vertebrae by using an intravertebral reduction device a 1-year follow-up study","volume":"90","author":"Lin","year":"2016","unstructured":"Lin JHWang SHLin EY & Chiang YH. Better height restoration, greater kyphosis correction, and fewer refractures of cemented vertebrae by using an intravertebral reduction device a 1-year follow-up study. World Neurosurgery201690391\u2013396. (https:\/\/doi.org\/10.1016\/j.wneu.2016.03.009)"},{"key":"bib57","series-title":"BioMed Research International","first-page":"927813","article-title":"Clinical outcome after the use of a new craniocaudal expandable implant for vertebral compression fracture treatment one year results from a prospective multicentric study","volume":"2015","author":"Noriega","year":"2015","unstructured":"Noriega DKr\u00fcger AArdura FHansen-Algenstaedt NHassel FBarreau X & Beyerlein J. Clinical outcome after the use of a new craniocaudal expandable implant for vertebral compression fracture treatment one year results from a prospective multicentric study. BioMed Research International20152015927813\u2013927813. (https:\/\/doi.org\/10.1155\/2015\/927813)"},{"key":"bib58","series-title":"Osteoporosis International","first-page":"2047","article-title":"Safety and clinical performance of kyphoplasty and SpineJack((r)) procedures in the treatment of osteoporotic vertebral compression fractures a pilot, monocentric, investigator-initiated study","volume":"27","author":"Noriega","year":"2016","unstructured":"Noriega DCRamajo RHLite ISToribio BCorredera RArdura F & Kr\u00fcger A. Safety and clinical performance of kyphoplasty and SpineJack((r)) procedures in the treatment of osteoporotic vertebral compression fractures a pilot, monocentric, investigator-initiated study. Osteoporosis International2016272047\u20132055. (https:\/\/doi.org\/10.1007\/s00198-016-3494-x)"},{"key":"bib59","series-title":"Osteoporosis International","first-page":"637","article-title":"Long-term safety and clinical performance of kyphoplasty and SpineJack(r) procedures in the treatment of osteoporotic vertebral compression fractures a pilot, monocentric, investigator-initiated study","volume":"30","author":"Noriega","year":"2019","unstructured":"Noriega DCRodr\u00edguez-Monsalve FRamajo RLite ISToribio B & Ardura F. Long-term safety and clinical performance of kyphoplasty and SpineJack(r) procedures in the treatment of osteoporotic vertebral compression fractures a pilot, monocentric, investigator-initiated study. Osteoporosis International201930637\u2013645. (https:\/\/doi.org\/10.1007\/s00198-018-4773-5)"},{"key":"bib60","series-title":"Saudi Medical Journal","first-page":"52","article-title":"The efficacy of a percutaneous expandable titanium device in anatomical reduction of vertebral compression fractures of the thoracolumbar spine","volume":"36","author":"Baeesa","year":"2015","unstructured":"Baeesa SSKrueger AArag\u00f3n FA & Noriega DC. The efficacy of a percutaneous expandable titanium device in anatomical reduction of vertebral compression fractures of the thoracolumbar spine. Saudi Medical Journal20153652\u201360. (https:\/\/doi.org\/10.15537\/smj.2015.1.9463)"},{"key":"bib61","series-title":"BioMed Research International","first-page":"173872","article-title":"Clinical performance and safety of 108 SpineJack implantations 1-year results of a prospective multicentre single-arm registry study","volume":"2015","author":"Noriega","year":"2015","unstructured":"Noriega DMaestretti GRenaud CFrancaviglia NOuld-Slimane MQueinnec SEkkerlein HHassel FGumpert RSabatier P, et al.Clinical performance and safety of 108 SpineJack implantations 1-year results of a prospective multicentre single-arm registry study. BioMed Research International20152015173872\u2013173872. (https:\/\/doi.org\/10.1155\/2015\/173872)"},{"key":"bib62","series-title":"Spine Journal","first-page":"1782","article-title":"A prospective, international, randomized, noninferiority study comparing an implantable titanium vertebral augmentation device versus balloon kyphoplasty in the reduction of vertebral compression fractures (SAKOS study)","volume":"19","author":"Noriega","year":"2019","unstructured":"Noriega DMarcia STheumann NBlondel BSimon AHassel FMaestretti GPetit AWeidle PAMandly AG, et al.A prospective, international, randomized, noninferiority study comparing an implantable titanium vertebral augmentation device versus balloon kyphoplasty in the reduction of vertebral compression fractures (SAKOS study). Spine Journal2019191782\u20131795. (https:\/\/doi.org\/10.1016\/j.spinee.2019.07.009)"},{"key":"bib63","series-title":"International Orthopaedics","first-page":"2773","article-title":"Clinical and radiological outcomes in thoracolumbar fractures using the SpineJack device A prospective study of seventy-four patients with a two point three year mean of follow-up","volume":"43","author":"Kerschbaumer","year":"2019","unstructured":"Kerschbaumer GGaulin BRuatti STonetti J & Boudissa M. Clinical and radiological outcomes in thoracolumbar fractures using the SpineJack device A prospective study of seventy-four patients with a two point three year mean of follow-up. International Orthopaedics2019432773\u20132779. (https:\/\/doi.org\/10.1007\/s00264-019-04391-1)"},{"key":"bib64","series-title":"European Spine Journal","first-page":"601","article-title":"Prospective study of standalone balloon kyphoplasty with calcium phosphate cement augmentation in traumatic fractures","volume":"16","author":"Maestretti","year":"2007","unstructured":"Maestretti GCremer COtten P & Jakob RP. Prospective study of standalone balloon kyphoplasty with calcium phosphate cement augmentation in traumatic fractures. European Spine Journal200716601\u2013610. (https:\/\/doi.org\/10.1007\/s00586-006-0258-x)"},{"key":"bib65","series-title":"European Spine Journal","first-page":"1354","article-title":"A prospective study of percutaneous balloon kyphoplasty with calcium phosphate cement in traumatic vertebral fractures 10-year results","volume":"23","author":"Maestretti","year":"2014","unstructured":"Maestretti GSutter PMonnard ECiarpaglini RWahl PHoogewoud H & Gautier E. A prospective study of percutaneous balloon kyphoplasty with calcium phosphate cement in traumatic vertebral fractures 10-year results. European Spine Journal2014231354\u20131360. (https:\/\/doi.org\/10.1007\/s00586-014-3206-1)"},{"key":"bib66","series-title":"Neurochirurgie","first-page":"272","article-title":"Percutaneous pedicle screw fixation and kyphoplasty for management of thoracolumbar burst fractures","volume":"53","author":"Fuentes","year":"2007","unstructured":"Fuentes SMetellus PFondop JPech-Gourg GDufour H & Grisoli F. Percutaneous pedicle screw fixation and kyphoplasty for management of thoracolumbar burst fractures. Neurochirurgie200753272\u2013276. French. (https:\/\/doi.org\/10.1016\/j.neuchi.2007.04.006)"},{"key":"bib67","series-title":"Der Orthopade","first-page":"356","article-title":"Vertebral body stenting. A method for repositioning and augmenting vertebral compression fractures","volume":"31","author":"F\u00fcrderer","year":"2002","unstructured":"F\u00fcrderer SAnders MSchwindling BSalick MD\u00fcber CWenda KUrban RGl\u00fcck M & Eysel P. Vertebral body stenting. A method for repositioning and augmenting vertebral compression fractures. Der Orthopade200231356\u2013361. (https:\/\/doi.org\/10.1007\/s00132-001-0275-8)"},{"key":"bib68","series-title":"European Journal of Radiology","first-page":"783","article-title":"Assisted techniques for vertebral cementoplasty why should we do it?","volume":"84","author":"Muto","year":"2015","unstructured":"Muto MMarcia SGuarnieri G & Pereira V. Assisted techniques for vertebral cementoplasty why should we do it?European Journal of Radiology201584783\u2013788. (https:\/\/doi.org\/10.1016\/j.ejrad.2014.04.002)"},{"key":"bib69","series-title":"BMJ","first-page":"n71","article-title":"The PRISMA 2020 statement: an updated guideline for reporting systematic reviews","volume":"372","author":"Page","year":"2021","unstructured":"Page MJMcKenzie JEBossuyt PMBoutron IHoffmann TCMulrow CDShamseer LTetzlaff JMAkl EABrennan SE, et al.The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ2021372n71. (https:\/\/doi.org\/10.1136\/bmj.n71)"},{"key":"bib70","series-title":"European Spine Journal","first-page":"336","article-title":"Short segment pedicle screw instrumentation and augmentation vertebroplasty in lumbar burst fractures: an experience","volume":"17","author":"Afzal","year":"2008","unstructured":"Afzal SAkbar S & Dhar SA. Short segment pedicle screw instrumentation and augmentation vertebroplasty in lumbar burst fractures: an experience. European Spine Journal200817336\u2013341. (https:\/\/doi.org\/10.1007\/s00586-008-0587-z)"},{"key":"bib71","series-title":"Orthopaedics and Traumatology, Surgery and Research","first-page":"527","article-title":"Percutaneous management of thoracolumbar burst fractures: evolution of techniques and strategy","volume":"97","author":"Blondel","year":"2011","unstructured":"Blondel BFuentes SPech-Gourg GAdetchessi TTropiano P & Dufour H. Percutaneous management of thoracolumbar burst fractures: evolution of techniques and strategy. Orthopaedics and Traumatology, Surgery and Research201197527\u2013532. (https:\/\/doi.org\/10.1016\/j.otsr.2011.03.020)"},{"key":"bib72","series-title":"Acta Orthopaedica Belgica","first-page":"718","article-title":"Treatment of thoracolumbar burst fractures: short-segment pedicle instrumentation versus kyphoplasty","volume":"79","author":"Zhang","year":"2013","unstructured":"Zhang LZou JGan MShi JLi J & Yang H. Treatment of thoracolumbar burst fractures: short-segment pedicle instrumentation versus kyphoplasty. Acta Orthopaedica Belgica201379718\u2013725."},{"issue":"Supplement 1","key":"bib73","series-title":"Journal of Clinical Orthopaedics and Trauma","first-page":"S163","article-title":"Percutaneous fixation and balloon kyphoplasty for the treatment of A3 thoracolumbar fractures","volume":"10","author":"Caruso","year":"2019","unstructured":"Caruso GGildone ALorusso VLombardi EAndreotti MGerace E & Massari L. Percutaneous fixation and balloon kyphoplasty for the treatment of A3 thoracolumbar fractures. Journal of Clinical Orthopaedics and Trauma201910(Supplement 1) S163\u2013S167. (https:\/\/doi.org\/10.1016\/j.jcot.2018.12.012)"},{"key":"bib74","series-title":"Orthopaedics and Traumatology, Surgery and Research","first-page":"1221","article-title":"Analysis of intervertebral discs adjacent to thoracolumbar A3 fractures treated by percutaneous instrumentation and kyphoplasty","volume":"106","author":"Collinet","year":"2020","unstructured":"Collinet ACharles YPNtilikina YTuzin N & Steib JP. Analysis of intervertebral discs adjacent to thoracolumbar A3 fractures treated by percutaneous instrumentation and kyphoplasty. Orthopaedics and Traumatology, Surgery and Research20201061221\u20131226. (https:\/\/doi.org\/10.1016\/j.otsr.2020.05.006)"},{"key":"bib75","series-title":"Pain Physician","first-page":"E631","article-title":"Treatment of thoracolumbar Type A3 fractures using a percutaneous intravertebral expandable titanium implant: long-term follow-up results of a pilot Single Center study","volume":"24","author":"Noriega","year":"2021","unstructured":"Noriega DCCrespo-Sanjuan JOlan WJHernandez-Ramajo RBell DPSanz JJCHernandez GJLSanchez-Lite I & Ardura F. Treatment of thoracolumbar Type A3 fractures using a percutaneous intravertebral expandable titanium implant: long-term follow-up results of a pilot Single Center study. Pain Physician202124E631\u2013E638."},{"key":"bib76","series-title":"Spine","first-page":"2028","article-title":"AOSpine thoracolumbar spine injury classification system: fracture description, neurological status, and key modifiers","volume":"38","author":"Vaccaro","year":"2013","unstructured":"Vaccaro AROner CKepler CKDvorak MSchnake KBellabarba CReinhold MAarabi BKandziora FChapman J, et al.AOSpine thoracolumbar spine injury classification system: fracture description, neurological status, and key modifiers. Spine2013382028\u20132037. (https:\/\/doi.org\/10.1097\/BRS.0b013e3182a8a381)"},{"key":"bib77","series-title":"Orthopaedics and Traumatology, Surgery and Research","first-page":"39","article-title":"Evaluation of percutaneous surgery in the treatment of thoracolumbar fractures. Preliminary results of a prospective study on 65 patients","volume":"98","author":"Teyss\u00e9dou","year":"2012","unstructured":"Teyss\u00e9dou SSaget MPr\u00e9bet RLeclercq NVendeuvre T & Pries P. Evaluation of percutaneous surgery in the treatment of thoracolumbar fractures. Preliminary results of a prospective study on 65 patients. Orthopaedics and Traumatology, Surgery and Research20129839\u201347. (https:\/\/doi.org\/10.1016\/j.otsr.2011.08.009)"},{"key":"bib78","series-title":"Clinical Spine Surgery","first-page":"E1066","article-title":"Functional recovery following early kyphoplasty versus conservative management in stable Thoracuolumbar fractures in parachute jumpers: a randomized clinical trial","volume":"30","author":"Masoudi","year":"2017","unstructured":"Masoudi MSHaghnegahdar AGhaffarpasand F & Ilami G. Functional recovery following early kyphoplasty versus conservative management in stable Thoracuolumbar fractures in parachute jumpers: a randomized clinical trial. Clinical Spine Surgery201730E1066\u2013E1073. (https:\/\/doi.org\/10.1097\/BSD.0000000000000546)"},{"key":"bib79","series-title":"European Spine Journal","first-page":"624","article-title":"Comparison of kyphoplasty with use of a calcium phosphate cement and non-operative therapy in patients with traumatic non-osteoporotic vertebral fractures","volume":"18","author":"Schmelzer-Schmied","year":"2009","unstructured":"Schmelzer-Schmied NCartens CMeeder PJ & Dafonseca K. Comparison of kyphoplasty with use of a calcium phosphate cement and non-operative therapy in patients with traumatic non-osteoporotic vertebral fractures. European Spine Journal200918624\u2013629. (https:\/\/doi.org\/10.1007\/s00586-008-0880-x)"},{"issue":"6","key":"bib80","series-title":"Orthopaedics and Traumatology, Surgery and Research","first-page":"S105","article-title":"Minimally invasive management of thoraco-lumbar fractures: combined percutaneous fixation and balloon kyphoplasty","volume":"98","author":"Zairi","year":"2012","unstructured":"Zairi FCourt CTropiano PCharles YPTonetti JFuentes SLitrico SDeramond HBeaurain JOrcel P, et al.Minimally invasive management of thoraco-lumbar fractures: combined percutaneous fixation and balloon kyphoplasty. Orthopaedics and Traumatology, Surgery and Research201298(6) S105\u2013S111. (https:\/\/doi.org\/10.1016\/j.otsr.2012.06.004)"},{"issue":"Supplement 6","key":"bib81","series-title":"European Spine Journal","first-page":"664","article-title":"Balloon kyphoplasty for pure traumatic thoracolumbar fractures: retrospective analysis of 61 cases focusing on restoration of vertebral height","volume":"23","author":"de Falco","year":"2014","unstructured":"de Falco R & Bocchetti A. Balloon kyphoplasty for pure traumatic thoracolumbar fractures: retrospective analysis of 61 cases focusing on restoration of vertebral height. European Spine Journal201423(Supplement 6) 664\u2013670. (https:\/\/doi.org\/10.1007\/s00586-014-3548-8)"},{"key":"bib82","series-title":"European Spine Journal","first-page":"1492","article-title":"Percutaneous pedicle screw fixation plus kyphoplasty for thoracolumbar fractures A2, A3 and B2","volume":"26","author":"Korovessis","year":"2017","unstructured":"Korovessis PMpountogianni E & Syrimpeis V. Percutaneous pedicle screw fixation plus kyphoplasty for thoracolumbar fractures A2, A3 and B2. European Spine Journal2017261492\u20131498. (https:\/\/doi.org\/10.1007\/s00586-016-4743-6)"},{"key":"bib83","series-title":"World Neurosurgery","first-page":"e386","article-title":"Mid-term clinical and radiological outcomes after kyphoplasty in the treatment of thoracolumbar traumatic vertebral compression fractures","volume":"115","author":"Grelat","year":"2018","unstructured":"Grelat MMadkouri RComby POFahed ELemogne B & Thouant P. Mid-term clinical and radiological outcomes after kyphoplasty in the treatment of thoracolumbar traumatic vertebral compression fractures. World Neurosurgery2018115e386\u2013e392. (https:\/\/doi.org\/10.1016\/j.wneu.2018.04.060)"},{"key":"bib84","series-title":"European Journal of Orthopaedic Surgery and Traumatology","first-page":"849","article-title":"Minimally invasive fixation techniques for thoracolumbar fractures: comparison between percutaneous pedicle screw with intermediate screw (PPSIS) and percutaneous pedicle screw with kyphoplasty (PPSK)","volume":"28","author":"Caruso","year":"2018","unstructured":"Caruso GLombardi EAndreotti MLorusso VGildone APadovani S & Massari L. Minimally invasive fixation techniques for thoracolumbar fractures: comparison between percutaneous pedicle screw with intermediate screw (PPSIS) and percutaneous pedicle screw with kyphoplasty (PPSK). European Journal of Orthopaedic Surgery and Traumatology201828849\u2013858. (https:\/\/doi.org\/10.1007\/s00590-018-2122-1)"},{"issue":"Supplement 2","key":"bib85","series-title":"European Spine Journal","first-page":"182","article-title":"The pedicle instrumentation and percutaneous elevation (Pi.Pe): a new cementless surgical technique in type A post-traumatic vertebral fractures","volume":"27","author":"Piazzolla","year":"2018","unstructured":"Piazzolla ASolarino GBizzoca DParato CMonteleone GDicuonzo F & Moretti B. The pedicle instrumentation and percutaneous elevation (Pi.Pe): a new cementless surgical technique in type A post-traumatic vertebral fractures. European Spine Journal201827(Supplement 2) 182\u2013189. (https:\/\/doi.org\/10.1007\/s00586-018-5602-4)"},{"key":"bib86","series-title":"Journal of Neurosurgical Sciences","first-page":"193","article-title":"Reconstruction of vertebral body in thoracolumbar AO type A post-traumatic fractures by balloon kyphoplasty: a series of 85 patients with a long follow-up and review of the literature","volume":"66","author":"Francaviglia","year":"2022","unstructured":"Francaviglia NVilla AMaiello MCostantino GAlessandrello RFMeli FOdierna Contino ALipani RFiorenza VLo Duca B, et al.Reconstruction of vertebral body in thoracolumbar AO type A post-traumatic fractures by balloon kyphoplasty: a series of 85 patients with a long follow-up and review of the literature. Journal of Neurosurgical Sciences202266193\u2013199. (https:\/\/doi.org\/10.23736\/S0390-5616.19.04628-9)"},{"key":"bib87","series-title":"Journal of Neurointerventional Surgery","first-page":"848","article-title":"Treating traumatic thoracolumbar spine fractures using minimally invasive percutaneous stabilization plus balloon kyphoplasty: a 102-patient series","volume":"13","author":"Salle","year":"2021","unstructured":"Salle HMeynard AAuditeau EGantois CRouchaud AMounayer CFaure P & Caire F. Treating traumatic thoracolumbar spine fractures using minimally invasive percutaneous stabilization plus balloon kyphoplasty: a 102-patient series. Journal of Neurointerventional Surgery202113848\u2013853. (https:\/\/doi.org\/10.1136\/neurintsurg-2020-017238)"},{"key":"bib88","series-title":"Journal of Neurosurgical Sciences","first-page":"169","article-title":"Minimally invasive percutaneous stabilization plus balloon kyphoplasty for the treatment of type A thoraco lumbar spine fractures: minimum 4 year's follow-up","volume":"58","author":"Zairi","year":"2014","unstructured":"Zairi FAboukais RMarinho PAllaoui M & Assaker R. Minimally invasive percutaneous stabilization plus balloon kyphoplasty for the treatment of type A thoraco lumbar spine fractures: minimum 4 year's follow-up. Journal of Neurosurgical Sciences201458169\u2013175."},{"key":"bib89","series-title":"Journal of Spine Surgery","first-page":"357","article-title":"Anatomical reconstruction of complete burst vertebral fracture case report\u2014combined reduction methods and armed kyphoplasty with stents filled with bone graft","volume":"9","author":"Moura","year":"2023","unstructured":"Moura DL & Ribeiro PG. Anatomical reconstruction of complete burst vertebral fracture case report\u2014combined reduction methods and armed kyphoplasty with stents filled with bone graft. Journal of Spine Surgery20239357\u2013368. (https:\/\/doi.org\/10.21037\/jss-22-117)"},{"key":"bib90","series-title":"Neurosurgical Focus","first-page":"E5","article-title":"Cement augmentation in vertebral burst fractures","volume":"37","author":"Zaryanov","year":"2014","unstructured":"Zaryanov AVPark DKKhalil JGBaker KC & Fischgrund JS. Cement augmentation in vertebral burst fractures. Neurosurgical Focus201437E5. (https:\/\/doi.org\/10.3171\/2014.5.FOCUS1495)"},{"key":"bib91","series-title":"Journal of Bone and Joint Surgery","first-page":"833","article-title":"Changes in the disc space after fractures of the thoracolumbar spine","volume":"80","author":"Oner","year":"1998","unstructured":"Oner FCvan der Rijt RRRamos LMDhert WJ & Verbout AJ. Changes in the disc space after fractures of the thoracolumbar spine. Journal of Bone and Joint Surgery199880833\u2013839. (https:\/\/doi.org\/10.1302\/0301-620x.80b5.8830)"},{"key":"bib92","series-title":"Spine","first-page":"1012","article-title":"Vertebral burst fractures: an experimental, morphologic, and radiographic study","volume":"17","author":"Fredrickson","year":"1992","unstructured":"Fredrickson BEEdwards WTRauschning WBayley JC & Yuan HA. Vertebral burst fractures: an experimental, morphologic, and radiographic study. Spine1992171012\u20131021. (https:\/\/doi.org\/10.1097\/00007632-199209000-00002)"},{"key":"bib93","series-title":"Spine","first-page":"692","article-title":"Biomechanics of indirect reduction of bone retropulsed into the spinal canal in vertebral fracture","volume":"18","author":"Harrington","year":"1993","unstructured":"Harrington RMBudorick THoyt JAnderson PA & Tencer AF. Biomechanics of indirect reduction of bone retropulsed into the spinal canal in vertebral fracture. Spine199318692\u2013699. (https:\/\/doi.org\/10.1097\/00007632-199305000-00003)"},{"key":"bib94","series-title":"Cardiovascular and Interventional Radiology","first-page":"1306","article-title":"Diffusion-weighted MRI assessment of adjacent disc degeneration after thoracolumbar vertebral fractures","volume":"39","author":"Noriega","year":"2016","unstructured":"Noriega DCMarcia SArdura FLite ISMarras M & Saba L. Diffusion-weighted MRI assessment of adjacent disc degeneration after thoracolumbar vertebral fractures. Cardiovascular and Interventional Radiology2016391306\u20131314. (https:\/\/doi.org\/10.1007\/s00270-016-1369-3)"},{"key":"bib95","series-title":"Revue de Chirurgie Orthop\u00e9dique et Reparatrice de l\u2019Appareil Moteur","first-page":"666","article-title":"Treatment of thoracolumbar junction burst fractures (Magerl A3) by balloon kyphoplasty: anatomic study","volume":"93","author":"Olivier","year":"2007","unstructured":"Olivier EBeldame JOuld-Slimane MPuech NLefebvre BMarouteau-Pasquier NDefives T & Duparc F. Treatment of thoracolumbar junction burst fractures (Magerl A3) by balloon kyphoplasty: anatomic study. Revue de Chirurgie Orthop\u00e9dique et Reparatrice de l\u2019Appareil Moteur200793666\u2013673. (https:\/\/doi.org\/10.1016\/s0035-1040(0773251-8)"},{"key":"bib96","series-title":"Spine Journal","first-page":"1092","article-title":"S Height restoration of osteoporotic vertebral compression fractures using different intravertebral reduction devices a cadaveric study","volume":"15","author":"Kr\u00fcger","year":"2015","unstructured":"Kr\u00fcger AOberkircher LFigiel JFlo\u00dfdorf FBolzinger FNoriega DC & Ruchholtz S. S Height restoration of osteoporotic vertebral compression fractures using different intravertebral reduction devices a cadaveric study. Spine Journal2015151092\u20131098. (https:\/\/doi.org\/10.1016\/j.spinee.2013.06.094)"},{"key":"bib97","series-title":"Spine","first-page":"658","article-title":"Minimal invasive short posterior instrumentation plus balloon kyphoplasty with calcium phosphate for burst and severe compression lumbar fractures","volume":"33","author":"Korovessis","year":"2008","unstructured":"Korovessis PHadjipavlou A & Repantis T. Minimal invasive short posterior instrumentation plus balloon kyphoplasty with calcium phosphate for burst and severe compression lumbar fractures. Spine200833658\u2013667. (https:\/\/doi.org\/10.1097\/BRS.0b013e318166e0bb)"},{"key":"bib98","series-title":"AJNR. American Journal of Neuroradiology","first-page":"1965","article-title":"Armed kyphoplasty an indirect central canal decompression technique in burst fractures","volume":"40","author":"Venier","year":"2019","unstructured":"Venier ARoccatagliata LIsalberti MScarone PKuhlen DEReinert MBonaldi GHirsch JA & Cianfoni A. Armed kyphoplasty an indirect central canal decompression technique in burst fractures. AJNR. American Journal of Neuroradiology2019401965\u20131972. (https:\/\/doi.org\/10.3174\/ajnr.A6285)"},{"key":"bib99","series-title":"Spine Journal","first-page":"217","article-title":"Intervertebral disc viability after burst fractures of the thoracic and lumbar spine treated with pedicle screw fixation and direct end-plate restoration","volume":"13","author":"Verlaan","year":"2013","unstructured":"Verlaan JJDhert WJ & Oner FC. Intervertebral disc viability after burst fractures of the thoracic and lumbar spine treated with pedicle screw fixation and direct end-plate restoration. Spine Journal201313217\u2013221. (https:\/\/doi.org\/10.1016\/j.spinee.2012.02.032)"},{"key":"bib100","series-title":"Orthopaedics and Traumatology, Surgery and Research","first-page":"61","article-title":"Radiologic study of disc behavior following compression fracture of the thoracolumbar hinge managed by kyphoplasty: a 52-case series","volume":"102","author":"Teyss\u00e9dou","year":"2016","unstructured":"Teyss\u00e9dou SSaget MGayet LEPries PBr\u00e8que C & Vendeuvre T. Radiologic study of disc behavior following compression fracture of the thoracolumbar hinge managed by kyphoplasty: a 52-case series. Orthopaedics and Traumatology, Surgery and Research201610261\u201365. (https:\/\/doi.org\/10.1016\/j.otsr.2015.11.011)"},{"key":"bib101","series-title":"European Spine Journal","first-page":"2256","article-title":"Internal fixation with percutaneous kyphoplasty compared with simple percutaneous kyphoplasty for thoracolumbar burst fractures in elderly patients: a prospective randomized controlled trial","volume":"22","author":"He","year":"2013","unstructured":"He DWu LSheng XXiao QZhu YYu WLiu F & Zhu K. Internal fixation with percutaneous kyphoplasty compared with simple percutaneous kyphoplasty for thoracolumbar burst fractures in elderly patients: a prospective randomized controlled trial. European Spine Journal2013222256\u20132263. (https:\/\/doi.org\/10.1007\/s00586-013-2972-5)"},{"key":"bib102","series-title":"Cardiovascular and Interventional Radiology","first-page":"1579","article-title":"Efficacy of the vertebral body stenting system for the restoration of vertebral height in acute traumatic compression fractures in a non-osteoporotic population","volume":"42","author":"Garnon","year":"2019","unstructured":"Garnon JDor\u00e9 BAuloge PCaudrelier JDalili DRamamurthy NKoch GCazzato RL & Gangi A. Efficacy of the vertebral body stenting system for the restoration of vertebral height in acute traumatic compression fractures in a non-osteoporotic population. Cardiovascular and Interventional Radiology2019421579\u20131587. (https:\/\/doi.org\/10.1007\/s00270-019-02265-y)"},{"key":"bib103","series-title":"European Spine Journal","first-page":"3089","article-title":"Vertebral balloon kyphoplasty versus vertebral body stenting in non-osteoporotic vertebral compression fractures at the thoracolumbar junction: a comparative radiological study and finite element analysis (BONEXP study)","volume":"30","author":"Vendeuvre","year":"2021","unstructured":"Vendeuvre TBrossard PPic JBBillot MGayet LEPries PTeyss\u00e9dou SGermaneau A & Rigoard P. Vertebral balloon kyphoplasty versus vertebral body stenting in non-osteoporotic vertebral compression fractures at the thoracolumbar junction: a comparative radiological study and finite element analysis (BONEXP study). European Spine Journal2021303089\u20133098. (https:\/\/doi.org\/10.1007\/s00586-021-06785-5)"},{"key":"bib104","series-title":"Neurosurgical Focus","first-page":"e9","article-title":"Kyphoplasty-augmented short-segment pedicle screw fixation of traumatic lumbar burst fractures: initial clinical experience and literature review","volume":"18","author":"Acosta","year":"2005","unstructured":"Acosta FLAryan HETaylor WR & Ames CP. Kyphoplasty-augmented short-segment pedicle screw fixation of traumatic lumbar burst fractures: initial clinical experience and literature review. Neurosurgical Focus200518e9. (https:\/\/doi.org\/10.3171\/foc.2005.18.3.10)"},{"key":"bib105","series-title":"Spine","first-page":"971","article-title":"A randomized trial of balloon kyphoplasty and nonsurgical management for treating acute vertebral compression fractures: vertebral body kyphosis correction and surgical parameters","volume":"38","author":"Van Meirhaeghe","year":"2013","unstructured":"Van Meirhaeghe JBastian LBoonen SRanstam JTillman JBWardlaw D & FREEInvestigators. A randomized trial of balloon kyphoplasty and nonsurgical management for treating acute vertebral compression fractures: vertebral body kyphosis correction and surgical parameters. Spine201338971\u2013983. (https:\/\/doi.org\/10.1097\/BRS.0b013e31828e8e22)"},{"key":"bib106","series-title":"World Neurosurgery","first-page":"798","article-title":"A retrospective study of thoracolumbar fractures treated with fixation and nonfusion surgery of intravertebral bone graft assisted with balloon kyphoplasty","volume":"108","author":"Zhang","year":"2017","unstructured":"Zhang COuyang BLi PWang LLuo LZhao CLiu LTu BHou TArnold P, et al.A retrospective study of thoracolumbar fractures treated with fixation and nonfusion surgery of intravertebral bone graft assisted with balloon kyphoplasty. World Neurosurgery2017108798\u2013806. (https:\/\/doi.org\/10.1016\/j.wneu.2017.08.093)"},{"key":"bib107","series-title":"Journal of Neurointerventional Surgery","first-page":"313","article-title":"Vertebral body stent augmentation to reconstruct the anterior column in neoplastic extreme osteolysis","volume":"11","author":"Cianfoni","year":"2019","unstructured":"Cianfoni ADistefano DPravat\u00e0 EEspeli VPesce GMordasini PLa Barbera LScarone P & Bonaldi G. Vertebral body stent augmentation to reconstruct the anterior column in neoplastic extreme osteolysis. Journal of Neurointerventional Surgery201911313\u2013318. (https:\/\/doi.org\/10.1136\/neurintsurg-2018-014231)"},{"key":"bib108","series-title":"Spine","first-page":"1284","article-title":"Calcium-phosphate and polymethylmethacrylate cement in long-term outcome after kyphoplasty of painful osteoporotic vertebral fractures","volume":"33","author":"Grafe","year":"2008","unstructured":"Grafe IABaier MN\u00f6ldge GWeiss CFonseca KHillmeier JLibicher MRudofsky GMetzner CNawroth P, et al.Calcium-phosphate and polymethylmethacrylate cement in long-term outcome after kyphoplasty of painful osteoporotic vertebral fractures. Spine2008331284\u20131290. (https:\/\/doi.org\/10.1097\/BRS.0b013e3181714a84)"},{"key":"bib109","series-title":"Spine","first-page":"1521","article-title":"Histologic evaluation of human vertebral bodies after vertebral augmentation with polymethyl methacrylate","volume":"28","author":"Togawa","year":"2003","unstructured":"Togawa DBauer TWLieberman IH & Takikawa S. Histologic evaluation of human vertebral bodies after vertebral augmentation with polymethyl methacrylate. Spine2003281521\u20131527. (https:\/\/doi.org\/10.1097\/01.BRS.0000076825.12630.3C)"},{"key":"bib110","series-title":"Journal of Bone and Joint Surgery","first-page":"1230","article-title":"Histologic changes after vertebroplasty","volume":"86","author":"Verlaan","year":"2004","unstructured":"Verlaan JJOner FCSlootweg PJVerbout AJ & Dhert WJ. Histologic changes after vertebroplasty. Journal of Bone and Joint Surgery2004861230\u20131238. (https:\/\/doi.org\/10.2106\/00004623-200406000-00016)"},{"key":"bib111","series-title":"Osteoporosis International","first-page":"1208","article-title":"Osseous integration of calcium phosphate in osteoporotic vertebral fractures after kyphoplasty initial results from a clinical and experimental pilot study","volume":"17","author":"Libicher","year":"2006","unstructured":"Libicher MHillmeier JLiegibel USommer UPyerin WVetter MMeinzer HPGrafe IMeeder PN\u00f6ldge G, et al.Osseous integration of calcium phosphate in osteoporotic vertebral fractures after kyphoplasty initial results from a clinical and experimental pilot study. Osteoporosis International2006171208\u20131215. (https:\/\/doi.org\/10.1007\/s00198-006-0128-8)"},{"key":"bib112","series-title":"European Spine Journal","first-page":"2602","article-title":"Is vertebral body stenting in combination with CaP cement superior to kyphoplasty?","volume":"27","author":"Sch\u00fctzenberger","year":"2018","unstructured":"Sch\u00fctzenberger SSchwarz SMGreiner LHolub OGrabner SHuf WSailler A & Fialka C. Is vertebral body stenting in combination with CaP cement superior to kyphoplasty?European Spine Journal2018272602\u20132608. (https:\/\/doi.org\/10.1007\/s00586-018-5717-7)"},{"key":"bib113","series-title":"Clinical Spine Surgery","first-page":"E291","article-title":"Osteointegration and resorption of intravertebral and extravertebral calcium phosphate cement","volume":"30","author":"Klein","year":"2017","unstructured":"Klein RTetzlaff RWeiss CSch\u00e4fer MKTanner MWiedenh\u00f6fer BGrafe IMeeder PJNoeldge GNawroth PP, et al.Osteointegration and resorption of intravertebral and extravertebral calcium phosphate cement. Clinical Spine Surgery201730E291\u2013E296. (https:\/\/doi.org\/10.1097\/BSD.0b013e3182aab2df)"},{"key":"bib114","series-title":"European Spine Journal","first-page":"45","article-title":"Fixation of thoracolumbar fractures with the Dick fixator the influence of transpedicular bone grafting","volume":"3","author":"Crawford","year":"1994","unstructured":"Crawford RJ & Askin GN. Fixation of thoracolumbar fractures with the Dick fixator the influence of transpedicular bone grafting. European Spine Journal1994345\u201351. (https:\/\/doi.org\/10.1007\/BF02428316)"},{"key":"bib115","series-title":"Acta Orthopaedica Belgica","first-page":"815","article-title":"Transpedicular bone grafting as a supplement to posterior pedicle screw instrumentation in thoracolumbar burst fractures","volume":"75","author":"Van Herck","year":"2009","unstructured":"Van Herck BLeirs G & Van Loon J. Transpedicular bone grafting as a supplement to posterior pedicle screw instrumentation in thoracolumbar burst fractures. Acta Orthopaedica Belgica200975815\u2013821."},{"key":"bib116","series-title":"Spine","first-page":"213","article-title":"Short-segment pedicle instrumentation of thoracolumbar burst fractures does transpedicular intracorporeal grafting prevent early failure?","volume":"26","author":"Alanay","year":"2001","unstructured":"Alanay AAcaroglu EYazici MOznur A & Surat A. Short-segment pedicle instrumentation of thoracolumbar burst fractures does transpedicular intracorporeal grafting prevent early failure?Spine200126213\u2013217. (https:\/\/doi.org\/10.1097\/00007632-200101150-00017)"},{"key":"bib117","series-title":"Spine","first-page":"88","article-title":"Late results of thoracolumbar fractures after posterior instrumentation and transpedicular bone grafting","volume":"26","author":"Knop","year":"2001","unstructured":"Knop CFabian HFBastian L & Blauth M. Late results of thoracolumbar fractures after posterior instrumentation and transpedicular bone grafting. Spine20012688\u201399. (https:\/\/doi.org\/10.1097\/00007632-200101010-00016)"},{"key":"bib118","series-title":"Journal of Anatomy","first-page":"697","article-title":"Long-term reaction to bone cement in osteoporotic bone new bone formation in vertebral bodies after vertebroplasty","volume":"212","author":"Braunstein","year":"2008","unstructured":"Braunstein VSprecher CMGisep ABenneker LYen KSchneider EHeini P & Milz S. Long-term reaction to bone cement in osteoporotic bone new bone formation in vertebral bodies after vertebroplasty. Journal of Anatomy2008212697\u2013701. (https:\/\/doi.org\/10.1111\/j.1469-7580.2008.00883.x)"},{"key":"bib119","series-title":"Acta Orthopaedica Scandinavica","first-page":"555","article-title":"Incomplete incorporation of morselized and impacted autologous bone graft a histological study in 4 intracorporally grafted lumbar fractures","volume":"70","author":"T\u00e4gil","year":"1999","unstructured":"T\u00e4gil MJohnsson RStromqvist B & Aspenberg P. Incomplete incorporation of morselized and impacted autologous bone graft a histological study in 4 intracorporally grafted lumbar fractures. Acta Orthopaedica Scandinavica199970555\u2013558. (https:\/\/doi.org\/10.3109\/17453679908997841)"}],"container-title":["EFORT Open Reviews"],"original-title":[],"link":[{"URL":"https:\/\/eor.bioscientifica.com\/view\/journals\/eor\/9\/4\/EOR-23-0190.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/eor.bioscientifica.com\/downloadpdf\/journals\/eor\/9\/4\/EOR-23-0190.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/eor.bioscientifica.com\/downloadpdf\/journals\/eor\/9\/4\/EOR-23-0190.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,20]],"date-time":"2026-07-20T13:51:18Z","timestamp":1784555478000},"score":1,"resource":{"primary":{"URL":"http:\/\/journals.bioscientifica.com\/eor\/article\/9\/4\/309-322\/2629"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,1]]},"references-count":119,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.1530\/eor-23-0190","relation":{},"ISSN":["2058-5241"],"issn-type":[{"value":"2058-5241","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,1]]}}}