{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,22]],"date-time":"2025-12-22T10:14:33Z","timestamp":1766398473255,"version":"3.48.0"},"reference-count":15,"publisher":"IMR Press","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["HSF"],"abstract":"<jats:p>&lt;p&gt;&lt;b&gt;Background:&lt;\/b&gt; For successful transcatheter closure of an atrial septal defect with the Amplatzer septal occluder, the shape of the defect should be considered before selecting the device size. The purpose of this study was to evaluate the results of transcatheter closure of an ovoid atrial septal defect.&lt;\/p&gt;&lt;p&gt;&lt;b&gt;Methods:&lt;\/b&gt; Between January 2010 and February 2012, cardiac computer tomography examinations were performed in 78 patients who subsequently underwent transcatheter closure of an atrial septal defect. In this retrospective study, we reviewed these patients' medical records. We defined an ovoid atrial septal defect as a value of 0.75 for the ratio of the shortest diameter of the defect to the longest diameter, as measured in a computed tomography image. Transthoracic echocardiography examinations were made at 1 day and 6 months after the procedure.&lt;\/p&gt;&lt;p&gt;&lt;b&gt;Results:&lt;\/b&gt; Transcatheter closure of an atrial septal defect was successful in 26 patients in the ovoid-defect group and in 52 patients in the round-defect group. There were no serious complications in either group, and the rate of complete closure at 6 months was 92.3% in the ovoid-defect group and 93.1% in the round-defect group (&lt;i&gt;P &gt;&lt;\/i&gt; .05). The mean (SD) difference between the device size and the defect's longest diameter, and the mean ratio of the device size to the longest diameter were significantly smaller in the ovoid-defect group (1.7 \ufffd 2.9 versus 3.8 \ufffd 2.5 and 1.1 \ufffd 0.1 versus 1.3 \ufffd 0.2, respectively).&lt;\/p&gt;&lt;p&gt;&lt;b&gt;Conclusions:&lt;\/b&gt; Transcatheter closure of an atrial septal defect is indicated even for an ovoid atrial septal defect. Ovoid atrial septal defects can be closed successfully with smaller sizes of the Amplatzer septal occluder than for round atrial septal defects.&lt;\/p&gt;<\/jats:p>","DOI":"10.1532\/hsf98.20121131","type":"journal-article","created":{"date-parts":[[2013,8,19]],"date-time":"2013-08-19T21:04:22Z","timestamp":1376946262000},"page":"193","source":"Crossref","is-referenced-by-count":0,"title":["Device Size for Transcatheter Closure of Ovoid Interatrial Septal Defect"],"prefix":"10.31083","volume":"16","author":[{"given":"Eun Hyun","family":"Cho","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinyoung","family":"Song","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eun Young","family":"Choi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sang Yoon","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"16242","published-online":{"date-parts":[[2013,8,19]]},"reference":[{"key":"1","doi-asserted-by":"crossref","first-page":"484","DOI":"10.1017\/S1047951100008179","article-title":"Three-dimensional echocardiography in transcatheter closure of atrial septal defects","volume":"10","author":"P. Acar","year":"2000","journal-title":"Cardiol Young"},{"key":"2","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1002\/ccd.20211","article-title":"Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk","volume":"63","author":"Z. Amin","year":"2004","journal-title":"Catheter Cardiovasc Interv"},{"key":"3","doi-asserted-by":"crossref","first-page":"1213","DOI":"10.1016\/j.jacc.2004.12.072","article-title":"Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder","volume":"45","author":"A. Divekar","year":"2005","journal-title":"J Am Coll Cardiol"},{"key":"4","doi-asserted-by":"crossref","first-page":"1381","DOI":"10.1093\/oxfordjournals.eurheartj.a060398","article-title":"Peri-operative complications following surgical closure of atrial septal defect type II in 232 patientsa baseline study","volume":"15","author":"M. Galal","year":"1994","journal-title":"Eur Heart J"},{"key":"5","doi-asserted-by":"crossref","first-page":"28","DOI":"10.4103\/0974-2069.79619","article-title":"Trans-catheter closure of atrial septal defect: balloon sizing or no balloon sizing - single centre experience","volume":"4","author":"S. Gupta","year":"2011","journal-title":"Ann Pediatr Cardiol"},{"key":"6","doi-asserted-by":"crossref","first-page":"1890","DOI":"10.1016\/S0735-1097(02)01886-7","article-title":"The incidence of congenital heart disease","volume":"39","author":"J. Hoffman","year":"2002","journal-title":"J Am Coll Cardiol"},{"key":"7","doi-asserted-by":"crossref","first-page":"714","DOI":"10.1016\/j.echo.2010.04.016","article-title":"En face view of atrial septal defect by two-dimensional transthoracic echocardiography: comparison to real-time three-dimensional transesophageal echocardiography","volume":"23","author":"X. Huang","year":"2010","journal-title":"J Am Soc Echocardiogr"},{"key":"8","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1016\/j.echo.2010.12.011","article-title":"Real-time three-dimensional transesophageal echocardiography in patients with secundum atrial septal defects: outcomes following transcatheter closure","volume":"24","author":"A. Johri","year":"2011","journal-title":"J Am Soc Echocardiogr"},{"key":"9","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1111\/j.1747-0803.2009.00358.x","article-title":"Long-term follow up of secundum atrial septal defect closure with the Amplatzer septal occluder","volume":"5","author":"M. Knepp","year":"2010","journal-title":"Congenit Heart Dis"},{"key":"10","doi-asserted-by":"crossref","first-page":"1522","DOI":"10.2214\/AJR.09.2854","article-title":"Amplatzer septal occluder closure of atrial septal defect: evaluation of transthoracic echocardiography, cardiac CT, and transesophageal echocardiography","volume":"193","author":"S. Ko","year":"2009","journal-title":"AJR Am J Roentgenol"},{"key":"11","doi-asserted-by":"crossref","first-page":"505","DOI":"10.1016\/j.jacc.2004.10.066","article-title":"Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders","volume":"45","author":"J. Masura","year":"2005","journal-title":"J Am Coll Cardiol"},{"key":"12","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1016\/j.echo.2011.02.008","article-title":"Three-dimensional transesophageal echocardiography of atrial septal defect: a qualitative and quantitative anatomic study","volume":"24","author":"D. Roberson","year":"2011","journal-title":"J Am Soc Echocardiogr"},{"key":"13","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1002\/ccd.20268","article-title":"Transcatheter atrial septal defect closure with the Amplatzer septal occluder: five-year follow-up","volume":"64","author":"G. Yew","year":"2005","journal-title":"Catheter Cardiovasc Interv"},{"key":"14","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1016\/j.ijcard.2003.04.022","article-title":"On-line intracardiac echocardiography alone for Amplatzer septal occluder selection and device deployment in adult patients with atrial septal defect","volume":"95","author":"M. Zanchetta","year":"2004","journal-title":"Int J Cardiol"},{"key":"15","doi-asserted-by":"crossref","first-page":"1677","DOI":"10.1016\/j.jacc.2003.08.023","article-title":"Intracardiac echocardiography-guided transcatheter closure of secundum atrial septal defect: a new efficient device selection method","volume":"42","author":"M. Zanchetta","year":"2003","journal-title":"J Am Coll Cardiol"}],"container-title":["The Heart Surgery Forum"],"original-title":[],"link":[{"URL":"http:\/\/journal.hsforum.com\/index.php\/HSF\/article\/viewFile\/896\/901","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,12,22]],"date-time":"2025-12-22T10:12:53Z","timestamp":1766398373000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.imrpress.com\/journal\/HSF\/16\/4\/10.1532\/HSF98.20121131"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,8,19]]},"references-count":15,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2013,8,1]]}},"URL":"https:\/\/doi.org\/10.1532\/hsf98.20121131","relation":{},"ISSN":["1522-6662","1098-3511"],"issn-type":[{"type":"electronic","value":"1522-6662"},{"type":"print","value":"1098-3511"}],"subject":[],"published":{"date-parts":[[2013,8,19]]}}}