{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,5,17]],"date-time":"2024-05-17T18:49:46Z","timestamp":1715971786306},"reference-count":20,"publisher":"International Heart Journal (Japanese Heart Journal)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int. Heart J."],"published-print":{"date-parts":[[2017]]},"DOI":"10.1536\/ihj.16-487","type":"journal-article","created":{"date-parts":[[2017,11,7]],"date-time":"2017-11-07T17:18:38Z","timestamp":1510075118000},"page":"874-879","source":"Crossref","is-referenced-by-count":1,"title":["Impact of the Relationship between the Defibrillation Threshold (DFT) and Clinical Outcomes in Recipients of Modern Era Implantable Cardioverter Defibrillator (ICD)"],"prefix":"10.1536","volume":"58","author":[{"given":"Yoshinari","family":"Enomoto","sequence":"first","affiliation":[{"name":"Division of Cardiovascular Medicine, Toho University Ohashi Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mahito","family":"Noro","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Medicine, Toho University Ohashi Medical Center"},{"name":"Department of Cardiovascular Center, Toho University Sakura Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masao","family":"Moroi","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Medicine, Toho University Ohashi Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masato","family":"Nakamura","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Medicine, Toho University Ohashi Medical Center"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kaoru","family":"Sugi","sequence":"additional","affiliation":[{"name":"Division of Cardiovascular Medicine, Toho University Ohashi Medical Center"},{"name":"Division of Cardiology, Odawara Cardiovascular Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"437","reference":[{"key":"1","unstructured":"1. Lee DS, Green LD, Liu PP, <i>et al<\/i>. Effectiveness of implantable defibrillators for preventing arrhythmic events and death: a meta-analysis. J Am Coll Cardiol 2003; 41: 1573-82."},{"key":"2","unstructured":"2. Nanthakumar K, Epstein AE, Kay GN, Plumb VJ, Lee DS. Prophylactic implantable cardioverter-defibrillator therapy in patients with left ventricular systolic dysfunction: a pooled analysis of 10 primary prevention trials. J Am Coll Cardiol 2004; 44: 2166-72."},{"key":"3","unstructured":"3. Brignole M, Occhetta E, Bongiorni MG, <i>et al<\/i>; SAFE-ICD Study Investigators. Clinical evaluation of defibrillation testing in an unselected population of 2120 consecutive patients undergoing first implantable cardioverter-defibrillator implant. J Am Coll Cardiol 2012; 60: 981-7."},{"key":"4","unstructured":"4. Ashino S, Nakai T, Sonoda K, <i>et al<\/i>. Assessment of efficacy and necessity of routine defibrillation threshold testing in patients undergoing implantable cardioverter-defibrillator (ICD) implantation. Int Heart J 2015; 56: 618-21."},{"key":"5","unstructured":"5. Blatt JA, Poole JE, Johnson GW, <i>et al<\/i>. No benefit from defibrillation threshold testing in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial). J Am Coll Cardiol 2008; 52: 551-6."},{"key":"6","unstructured":"6. Strickberger SA, Klein GJ. Is the defibrillation testing required for defibrillator implantation? J Am Coll Cardiol 2004; 44: 88-91. (Review)"},{"key":"7","unstructured":"7. Brunn J, B\u00f6cker D, Weber M, <i>et al<\/i>. Is there a need for routine testing of ICD defibirillation capacity? Results from more than 100 studies. Eur Heart J 2000; 21: 162-9."},{"key":"8","unstructured":"8. Calvi V, Duqo D, Capodanno D, <i>et al<\/i>. Intraoperative defibrillation threshold testing during implantable cardioverter-defibrillator insertion: do we really need it? Am Heart J 2010; 159: 98-102."},{"key":"9","unstructured":"9. Stavrakis S, Patel NH, Reynolds DW. Defibrillation threshold testing does not predict clinical outcomes during long-term follow-up: a meta-analysis. Pacing Clin Electrophysiol 2013; 36: 1402-8."},{"key":"10","unstructured":"10. Healey JS, Hohnloser SH, Glikson M, <i>et al<\/i>. Cardioverter defibrillator implantation without induction of ventricular fibrillation: a single-blind, non-inferiority, randomised controlled trial (SIMPLE). Lancet 2015; 385: 785-91."},{"key":"11","unstructured":"11. Ziegelhoeffer T, Siebel A, Markewitz A, <i>et al<\/i>. Intraoperative defibrillation testing should not be generally abandoned for all ICD procedures-a multicenter study on 4,572 consecutive patients. Thorac Cardiovasc Surg 2016; 64: 679-87."},{"key":"12","unstructured":"12. B\u00e4nsch D, Bonnemeier H, Brandt J, <i>et al<\/i>; NORDIC ICD Trial Investigators. Intra-operative defibrillation testing and clinical shock efficacy in patients with implantable cardioverter-defibrillators: the NORDIC ICD randomized clinical trial. Eur Heart J 2015; 36: 2500-7."},{"key":"13","first-page":"683","volume":"96","year":"1997","unstructured":"13. Xie J, Weil MH, Sun S, <i>et al<\/i>. High-energy defibrillation increases the severity of postresuscitation myocardial dysfunction. Circulation 1997; 96: 683-8.","journal-title":"Circulation","ISSN":"http:\/\/id.crossref.org\/issn\/0009-7322","issn-type":"print"},{"key":"14","doi-asserted-by":"publisher","unstructured":"14. Yamaguchi H, Weil M, Tang W, Kamohara T, Jin X, Bisera J. Myocardial dysfunction after electrical defibrillation. Resuscitation 2002; 54: 289-96.","DOI":"10.1016\/S0300-9572(02)00149-1"},{"key":"15","unstructured":"15. Hurst TM, Hinrichs M, Breidenbach C, Katz N, Waldecker B. Detection of myocardial injury during transvenous implantation of automatic cardioverter-defibrillators. J Am Coll Cardiol 1999; 34: 402-8."},{"key":"16","unstructured":"16. Lin EF, Dalal D, Cheng A, <i>et al<\/i>. Predictors of high defibrillation threshold in the modern era. Pacing Clin Electrophysiol 2013; 36: 231-7."},{"key":"17","unstructured":"17. Vischer AS, Sticherling C, Kuhne MS, Osswald S, Schaer BA. Role of defibrillation threshold testing in the contemporary defibrillator patient population. J Cardiovasc Electrophysiol 2013; 24: 437-41."},{"key":"18","unstructured":"18. Mizukami K, Yokoshiki H, Mitsuyama H, <i>et al<\/i>. Predictors of high defibrillation threshold in patients with implantable cardioverter-defibillator using a transvenous dual-coil lead. Circ J 2015; 79: 77-84."},{"key":"19","doi-asserted-by":"publisher","unstructured":"19. Epstein AE, Ellenbogen KA, Kirk KA, Kay GN, Dailey SM, Plumb VJ. Clinical characteristics and outcome of patients with high defibrillation thresholds. A multicenter study. Circulation 1992; 86: 1206-16.","DOI":"10.1161\/01.CIR.86.4.1206"},{"key":"20","unstructured":"20. Rubenstein JC, Kim MH, Morady F, Strickberger SA. The relationship between defibrillation threshold and total mortality. J Interv Card Electrophysiol 2013; 38: 203-8."}],"container-title":["International Heart Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ihj\/58\/6\/58_16-487\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,12,15]],"date-time":"2017-12-15T23:37:10Z","timestamp":1513381030000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ihj\/58\/6\/58_16-487\/_article"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017]]},"references-count":20,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1536\/ihj.16-487","relation":{},"ISSN":["1349-2365","1349-3299"],"issn-type":[{"value":"1349-2365","type":"print"},{"value":"1349-3299","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017]]}}}