{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T06:58:17Z","timestamp":1792479497644,"version":"4.5.0"},"reference-count":14,"publisher":"International Heart Journal (Japanese Heart Journal)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int. Heart J."],"published-print":{"date-parts":[[2018,9,1]]},"DOI":"10.1536\/ihj.17-442","type":"journal-article","created":{"date-parts":[[2018,8,28]],"date-time":"2018-08-28T18:29:38Z","timestamp":1535480978000},"page":"1002-1007","source":"Crossref","is-referenced-by-count":1,"title":["Implant Characteristics of Quadripolar and Bipolar Left Ventricular Leads for Cardiac Resynchronization Therapy"],"prefix":"10.1536","volume":"59","author":[{"given":"Kenji","family":"Ando","sequence":"first","affiliation":[{"name":"Kokura Memorial Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shigetaka","family":"Kanda","sequence":"additional","affiliation":[{"name":"Tokai University Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fumiharu","family":"Miura","sequence":"additional","affiliation":[{"name":"Hiroshima Prefectural Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keiichi","family":"Ashikaga","sequence":"additional","affiliation":[{"name":"Miyazaki Medical Association Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Natsuhiko","family":"Ehara","sequence":"additional","affiliation":[{"name":"Kobe City Medical Center General Hospital"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yoshiaki","family":"Sakai","sequence":"additional","affiliation":[{"name":"Chiba Emergency Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Toshihito","family":"Furukawa","sequence":"additional","affiliation":[{"name":"Biostatistical Research Co.,Ltd."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hiroyuki","family":"Yoshimura","sequence":"additional","affiliation":[{"name":"Medtronic Japan Co., Ltd."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazumasa","family":"Adachi","sequence":"additional","affiliation":[{"name":"Akashi Medical Center"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"437","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Cleland JG, Daubert JC, Erdmann E, <i>et al<\/i>. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med 2005; 352: 1539-49.","DOI":"10.1056\/NEJMoa050496"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Bristow MR, Saxon LA, Boehmer J, <i>et al<\/i>. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med 2004; 350: 2140-50.","DOI":"10.1056\/NEJMoa032423"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Abraham WT, Fisher WG, Smith AL, <i>et al<\/i>. Cardiac resynchronization in chronic heart failure. N Engl J Med 2002; 346: 1845-53.","DOI":"10.1056\/NEJMoa013168"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Gras D, Leclercq C, Tang AS, Bucknall C, Luttikhuis HO, Kirstein-Pedersen A. Cardiac resynchronization therapy in advanced heart failure the multicenter InSync clinical study. Eur J Heart Fail 2002; 4: 311-20.","DOI":"10.1016\/S1388-9842(02)00018-1"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Hummel JD, Coppess MA, Osborn JS, <i>et al<\/i>. Real-world assessment of acute left ventricular lead implant success and complication rates: results from the attain success clinical trial. Pacing Clin Electrophysiol 2016; 39: 1246-53.","DOI":"10.1111\/pace.12939"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Ziacchi M, Saporito D, Zardini M, <i>et al<\/i>. Left ventricular reverse remodeling elicited by a quadripolar lead: results from the multicenter Per4mer Study. Pacing Clin Electrophysiol 2016; 39: 250-60.","DOI":"10.1111\/pace.12792"},{"key":"7","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/j.hrthm.2014.12.019","volume":"12","year":"2015","unstructured":"7. Crossley GH, Biffi M, Johnson B, <i>et al<\/i>. Performance of a novel left ventricular lead with short bipolar spacing for cardiac resynchronization therapy: primary results of the Attain Performa Quadripolar Left Ventricular Lead Study. Heart Rhythm 2015; 12: 751-8.","journal-title":"Heart Rhythm","ISSN":"https:\/\/id.crossref.org\/issn\/1547-5271","issn-type":"print"},{"key":"8","doi-asserted-by":"crossref","first-page":"992","DOI":"10.1093\/europace\/eur032","volume":"13","year":"2011","unstructured":"8. Shetty AK, Duckett SG, Bostock J, Rosenthal E, Rinaldi CA. Use of a quadripolar left ventricular lead to achieve successful implantation in patients with previous failed attempts at cardiac resynchronization therapy. Europace 2011; 13: 992-6.","journal-title":"EP Europace","ISSN":"https:\/\/id.crossref.org\/issn\/1099-5129","issn-type":"print"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Kabutoya T, Imai Y, Watanabe H, Watanabe T, Komori T, Kario K. A case of useful short-spaced bipolar pacing of a left ventricular lead to avoid phrenic nerve stimulation. Int Heart J 2016; 57: 118-20.","DOI":"10.1536\/ihj.15-212"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Behar JM, Bostock J, Zhu Li AP, <i>et al<\/i>. Cardiac resynchronization therapy delivered via a multipolar left ventricular lead is associated with reduced mortality and elimination of phrenic nerve stimulation: long-term follow-up from a multicenter registry. J Cardiovasc Electrophysiol 2015; 26: 540-6.","DOI":"10.1111\/jce.12625"},{"key":"11","doi-asserted-by":"crossref","first-page":"1159","DOI":"10.1161\/CIRCULATIONAHA.110.000646","volume":"123","year":"2011","unstructured":"11. Singh JP, Klein HU, Huang DT, <i>et al<\/i>. Left ventricular lead position and clinical outcome in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) Trial. Circulation 2011; 123: 1159-66.","journal-title":"Circulation","ISSN":"https:\/\/id.crossref.org\/issn\/0009-7322","issn-type":"print"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Th\u00e9bault C, Donal E, Meunier C, <i>et al<\/i>. Sites of left and right ventricular lead implantation and response to cardiac resynchronization therapy observations from the REVERSE trial. Eur Heart J 2012; 33: 2662-71.","DOI":"10.1093\/eurheartj\/ehr505"},{"key":"13","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1093\/europace\/euu290","volume":"17","year":"2015","unstructured":"13. Forleo GB, Di Biase L, Bharmi R, <i>et al<\/i>. Hospitalization rates and associated cost analysis of cardiac resynchronization therapy with an implantable defibrillator and quadripolar versus bipolar left ventricular leads: a comparative effectiveness study. Europace 2015; 17: 101-7.","journal-title":"EP Europace","ISSN":"https:\/\/id.crossref.org\/issn\/1099-5129","issn-type":"print"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Cabrera Bueno F, Alzueta Rodr\u00edguez J, Olag\u00fce de Ros J, <i>et al<\/i>. Improvement in hemodynamic response using a quadripolar LV lead. Pacing Clin Electrophysiol 2013; 36: 963-9.","DOI":"10.1111\/pace.12172"}],"container-title":["International Heart Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ihj\/59\/5\/59_17-442\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2018,9,29]],"date-time":"2018-09-29T00:47:54Z","timestamp":1538182074000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ihj\/59\/5\/59_17-442\/_article"}},"subtitle":["Results from the Attain Success Japan Study"],"short-title":[],"issued":{"date-parts":[[2018,9,1]]},"references-count":14,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1536\/ihj.17-442","relation":{},"ISSN":["1349-2365","1349-3299"],"issn-type":[{"value":"1349-2365","type":"print"},{"value":"1349-3299","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,9,1]]}}}