{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,16]],"date-time":"2026-02-16T09:07:49Z","timestamp":1771232869972,"version":"3.50.1"},"reference-count":41,"publisher":"International Heart Journal (Japanese Heart Journal)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int. Heart J."],"published-print":{"date-parts":[[2021,5,29]]},"DOI":"10.1536\/ihj.20-627","type":"journal-article","created":{"date-parts":[[2021,5,14]],"date-time":"2021-05-14T22:07:36Z","timestamp":1621030056000},"page":"510-519","source":"Crossref","is-referenced-by-count":3,"title":["Early Vascular Healing Following Bioresorbable-Polymer Sirolimus-Eluting Stent Placement Compared to That with Durable-Polymer Everolimus-Eluting Stent"],"prefix":"10.1536","volume":"62","author":[{"given":"Kunihiro","family":"Ogura","sequence":"first","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroaki","family":"Tsujita","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yosuke","family":"Oishi","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hidenari","family":"Matsumoto","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoki","family":"Matsukawa","sequence":"additional","affiliation":[{"name":"Department of Legal Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rikuo","family":"Sakai","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Taito","family":"Arai","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shunya","family":"Sato","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hideaki","family":"Tanaka","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryota","family":"Masaki","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ken","family":"Arai","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kosuke","family":"Nomura","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryota","family":"Kosaki","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Koshiro","family":"Sakai","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Teruo","family":"Sekimoto","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seita","family":"Kondo","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shigeto","family":"Tsukamoto","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroyoshi","family":"Mori","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Showa University Fujigaoka Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Myong Hwa","family":"Yamamoto","sequence":"additional","affiliation":[{"name":"Division of Cardiology and Cardiac Catheterization Laboratories, Showa University Northern Yokohama Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kohei","family":"Wakabayashi","sequence":"additional","affiliation":[{"name":"Cardiovascular Centre, Showa University Koto-Toyosu Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hiroshi","family":"Suzuki","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Showa University Fujigaoka Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masahiko","family":"Ochiai","sequence":"additional","affiliation":[{"name":"Division of Cardiology and Cardiac Catheterization Laboratories, Showa University Northern Yokohama Hospital"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Toshiro","family":"Shinke","sequence":"additional","affiliation":[{"name":"Division of Cardiology, Department of Medicine, Showa University School of Medicine"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"437","reference":[{"key":"1","doi-asserted-by":"crossref","unstructured":"1. Stefanini GG, Holmes DR Jr. Drug-eluting coronary-artery stents. N Engl J Med 2013; 368: 254-65.","DOI":"10.1056\/NEJMra1210816"},{"key":"2","doi-asserted-by":"crossref","unstructured":"2. Wenaweser P, Daemen J, Zwahlen M, <i>et al<\/i>. Incidence and correlates of drug-eluting stent thrombosis in routine clinical practice. 4-year results from a large 2-institutional cohort study. J Am Coll Cardiol 2008; 52: 1134-40.","DOI":"10.1016\/j.jacc.2008.07.006"},{"key":"3","doi-asserted-by":"crossref","unstructured":"3. Otsuka F, Nakano M, Ladich E, Kolodgie FD, Virmani R. Pathologic etiologies of late and very late stent thrombosis following first-generation drug-eluting stent placement. Thrombosis 2012; 2012: 608593.","DOI":"10.1155\/2012\/608593"},{"key":"4","doi-asserted-by":"crossref","unstructured":"4. Gonzalo N, Serruys PW, Okamura T, <i>et al<\/i>. Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: a systematic quantitative approach. Heart 2009; 95: 1913-9.","DOI":"10.1136\/hrt.2009.172072"},{"key":"5","doi-asserted-by":"crossref","unstructured":"5. Matsumoto D, Shite J, Shinke T, <i>et al<\/i>. Neointimal coverage of sirolimus-eluting stents at 6-month follow-up: evaluated by optical coherence tomography. Eur Heart J 2007; 28: 961-7.","DOI":"10.1093\/eurheartj\/ehl413"},{"key":"6","doi-asserted-by":"crossref","unstructured":"6. Sarno G, Lagerqvist B, Fr\u00f6bert O, <i>et al<\/i>. Lower risk of stent thrombosis and restenosis with unrestricted use of &apos;new-generation&apos; drug-eluting stents: a report from the nationwide Swedish Coronary Angiography and Angioplasty Registry (SCAAR). Eur Heart J 2012; 33: 606-13.","DOI":"10.1093\/eurheartj\/ehr479"},{"key":"7","doi-asserted-by":"crossref","unstructured":"7. Guagliumi G, Sirbu V, Musumeci G, <i>et al<\/i>. Examination of the in vivo mechanisms of late drug-eluting stent thrombosis: findings from optical coherence tomography and intravascular ultrasound imaging. JACC Cardiovasc Interv 2012; 5: 12-20.","DOI":"10.1161\/CIRCINTERVENTIONS.112.970525"},{"key":"8","doi-asserted-by":"crossref","unstructured":"8. Taniwaki M, Radu MD, Zaugg S, <i>et al<\/i>. Mechanisms of very late drug-eluting stent thrombosis assessed by optical coherence tomography. Circulation 2016; 133: 650-60.","DOI":"10.1161\/CIRCULATIONAHA.115.019071"},{"key":"9","doi-asserted-by":"crossref","unstructured":"9. Kandzari DE, Mauri L, Koolen JJ, <i>et al<\/i>. Ultrathin, bioresorbable polymer sirolimus-eluting stents versus thin, durable polymer everolimus-eluting stents in patients undergoing coronary revascularisation (BIOFLOW V): a randomised trial. Lancet 2017; 390: 1843-52.","DOI":"10.1016\/S0140-6736(17)32249-3"},{"key":"10","doi-asserted-by":"crossref","unstructured":"10. Pilgrim T, Heg D, Roffi M, <i>et al<\/i>. Ultrathin strut biodegradable polymer sirolimus-eluting stent versus durable polymer everolimus-eluting stent for percutaneous coronary revascularisation (BIOSCIENCE): a randomised, single-blind, non-inferiority trial. Lancet 2014; 384: 2111-22.","DOI":"10.1016\/S0140-6736(14)61038-2"},{"key":"11","doi-asserted-by":"crossref","first-page":"e605","DOI":"10.4244\/EIJV12I5A100","volume":"12","year":"2016","unstructured":"11. Lee R, Foin N, Ng J, <i>et al<\/i>. Early coverage of drug-eluting stents analysed by optical coherence tomography: evidence of the impact of stent apposition and strut characteristics on the neointimal healing process. EuroIntervention 2016; 12: e605-14.","journal-title":"EuroIntervention","ISSN":"https:\/\/id.crossref.org\/issn\/1774-024X","issn-type":"print"},{"key":"12","doi-asserted-by":"crossref","unstructured":"12. Karjalainen PP, Varho V, Nammas W, <i>et al<\/i>. Early neointimal coverage and vasodilator response following biodegradable polymer sirolimus-eluting vs. durable polymer zotarolimus-eluting stents in patients with acute coronary syndrome -HATTRICK-OCT trial. Circ J 2015; 79: 360-7.","DOI":"10.1253\/circj.CJ-14-1000"},{"key":"13","doi-asserted-by":"crossref","unstructured":"13. Kretov E, Naryshkin I, Baystrukov V, <i>et al<\/i>. Three-months optical coherence tomography analysis of a biodegradable polymer, sirolimus-eluting stent. J Interv Cardiol 2018; 31: 442-9.","DOI":"10.1111\/joic.12510"},{"key":"14","doi-asserted-by":"crossref","unstructured":"14. Neumann FJ, Sousa-Uva M, Ahlsson A, <i>et al<\/i>. 2018 ESC\/EACTS Guidelines on myocardial revascularization. Eur Heart J 2019; 40: 87-165.","DOI":"10.1093\/eurheartj\/ehy855"},{"key":"15","doi-asserted-by":"crossref","unstructured":"15. Konishi A, Shinke T, Otake H, <i>et al<\/i>. Serial optical coherence tomography evaluation at 6, 12, and 24 months after Biolimus A9-eluting biodegradable polymer-coated stent implantation. Can J Cardiol 2015; 31: 980-8.","DOI":"10.1016\/j.cjca.2015.02.036"},{"key":"16","doi-asserted-by":"crossref","unstructured":"16. Tearney GJ, Regar E, Akasaka T, <i>et al<\/i>. Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation. J Am Coll Cardiol 2012; 59: 1058-72.","DOI":"10.1016\/j.jacc.2011.09.079"},{"key":"17","doi-asserted-by":"crossref","unstructured":"17. Shinke T, Itoh T, Ishida M, <i>et al<\/i>. Early and mid-term vascular responses to optical coherence tomography-guided everolimus-eluting stent implantation in stable coronary artery disease. Can J Cardiol 2019; 35: 1513-22.","DOI":"10.1016\/j.cjca.2019.07.633"},{"key":"18","doi-asserted-by":"crossref","unstructured":"18. Werner N, Nickenig G, Sinning JM. Complex PCI procedures: challenges for the interventional cardiologist. Clin Res Cardiol 2018; 107: 64-73.","DOI":"10.1007\/s00392-018-1316-1"},{"key":"19","doi-asserted-by":"publisher","unstructured":"19. Nakazawa G, Finn AV, Joner M, <i>et al<\/i>. Delayed arterial healing and increased late stent thrombosis at culprit sites after drug-eluting stent placement for acute myocardial infarction patients: an autopsy study. Circulation 2008; 118: 1138-45.","DOI":"10.1161\/CIRCULATIONAHA.107.762047"},{"key":"20","doi-asserted-by":"crossref","unstructured":"20. Otsuka F, Cheng Q, Yahagi K, <i>et al<\/i>. Acute thrombogenicity of a durable polymer everolimus-eluting stent relative to contemporary drug-eluting stents with biodegradable polymer coatings assessed ex vivo in a swine shunt model. JACC Cardiovasc Interv 2015; 8: 1248-60.","DOI":"10.1016\/j.jcin.2015.03.029"},{"key":"21","doi-asserted-by":"crossref","first-page":"2816","DOI":"10.1161\/01.CIR.103.23.2816","volume":"103","year":"2001","unstructured":"21. Kastrati A, Mehilli J, Dirschinger J, <i>et al<\/i>. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial. Circulation 2001; 103: 2816-21.","journal-title":"Circulation","ISSN":"https:\/\/id.crossref.org\/issn\/0009-7322","issn-type":"print"},{"key":"22","doi-asserted-by":"publisher","unstructured":"22. Kolandaivelu K, Swaminathan R, Gibson WJ, <i>et al<\/i>. Stent thrombogenicity early in high-risk interventional settings is driven by stent design and deployment and protected by polymer-drug coatings. Circulation 2011; 123: 1400-9.","DOI":"10.1161\/CIRCULATIONAHA.110.003210"},{"key":"23","doi-asserted-by":"crossref","unstructured":"23. Pache J, Kastrati A, Mehilli J, <i>et al<\/i>. Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO-2) trial. J Am Coll Cardiol 2003; 41: 1283-8.","DOI":"10.1016\/S0735-1097(03)00119-0"},{"key":"24","doi-asserted-by":"crossref","unstructured":"24. Baber U, Mehran R, Sharma SK, <i>et al<\/i>. Impact of the everolimus-eluting stent on stent thrombosis: a meta-analysis of 13 randomized trials. J Am Coll Cardiol 2011; 58: 1569-77.","DOI":"10.1016\/j.jacc.2011.06.049"},{"key":"25","doi-asserted-by":"crossref","unstructured":"25. Bangalore S, Toklu B, Patel N, Feit F, Stone GW. Newer-generation ultrathin strut drug-eluting stents versus older second-generation thicker strut drug-eluting stents for coronary artery disease. Circulation 2018; 138: 2216-26.","DOI":"10.1161\/CIRCULATIONAHA.118.034456"},{"key":"26","doi-asserted-by":"crossref","unstructured":"26. Windecker S, Haude M, Neumann FJ, <i>et al<\/i>. Comparison of a novel biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: results of the randomized BIOFLOW-II trial. Circ Cardiovasc Interv 2015; 8: e001441.","DOI":"10.1161\/CIRCINTERVENTIONS.114.001441"},{"key":"27","doi-asserted-by":"crossref","unstructured":"27. Gori T, Polimeni A, Indolfi C, R\u00e4ber L, Adriaenssens T, M\u00fcnzel T. Predictors of stent thrombosis and their implications for clinical practice. Nat Rev Cardiol 2019; 16: 243-56.","DOI":"10.1038\/s41569-018-0118-5"},{"key":"28","doi-asserted-by":"crossref","unstructured":"28. Serruys PW, Suwannasom P, Nakatani S, Onuma Y. Snowshoe versus ice skate for scaffolding of disrupted vessel wall. JACC Cardiovasc Interv 2015; 8: 910-3.","DOI":"10.1016\/j.jcin.2015.04.005"},{"key":"29","doi-asserted-by":"publisher","unstructured":"29. van der Giessen WJ, Lincoff AM, Schwartz RS, <i>et al<\/i>. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation 1996; 94: 1690-7.","DOI":"10.1161\/01.CIR.94.7.1690"},{"key":"30","doi-asserted-by":"crossref","unstructured":"30. Koppara T, Joner M, Bayer G, Steigerwald K, Diener T, Wittchow E. Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation. Thromb Haemost 2012; 107: 1161-71.","DOI":"10.1160\/TH12-01-0043"},{"key":"31","doi-asserted-by":"crossref","unstructured":"31. Wittchow E, Hartwig S. Still room for improvement: preclinical and bench testing of a thin-strut cobalt-chromium bare-metal stent with passive coating. J Biomed Mater Res B Appl Biomater 2017; 105: 1612-21.","DOI":"10.1002\/jbm.b.33702"},{"key":"32","doi-asserted-by":"crossref","unstructured":"32. Wang B, Mintz GS, Witzenbichler B, <i>et al<\/i>. Predictors and long-term clinical impact of acute stent malapposition: an assessment of dual antiplatelet therapy with drug-eluting stents (ADAPT-DES) intravascular ultrasound substudy. J Am Heart Assoc 2016; 5.","DOI":"10.1161\/JAHA.116.004438"},{"key":"33","doi-asserted-by":"crossref","unstructured":"33. Ozaki Y, Okumura M, Ismail TF, <i>et al<\/i>. The fate of incomplete stent apposition with drug-eluting stents: an optical coherence tomography-based natural history study. Eur Heart J 2010; 31: 1470-6.","DOI":"10.1093\/eurheartj\/ehq066"},{"key":"34","doi-asserted-by":"crossref","unstructured":"34. Inoue T, Shinke T, Otake H, <i>et al<\/i>. Impact of strut-vessel distance and underlying plaque type on the resolution of acute strut malapposition: serial optimal coherence tomography analysis after everolimus-eluting stent implantation. Int J Cardiovasc Imaging 2014; 30: 857-65.","DOI":"10.1007\/s10554-014-0422-z"},{"key":"35","doi-asserted-by":"crossref","unstructured":"35. Kawamori H, Shite J, Shinke T, <i>et al<\/i>. Natural consequence of post-intervention stent malapposition, thrombus, tissue prolapse, and dissection assessed by optical coherence tomography at mid-term follow-up. Eur Heart J Cardiovasc Imaging 2013; 14: 865-75.","DOI":"10.1093\/ehjci\/jes299"},{"key":"36","doi-asserted-by":"crossref","unstructured":"36. Oda H, Itoh T, Sasaki W, <i>et al<\/i>. Cut-off value of strut-vessel distance for the resolution of acute incomplete stent apposition in the early phase using serial optical coherence tomography after cobalt-chromium everolimus-eluting stent implantation. J Cardiol 2020; 75: 641-7.","DOI":"10.1016\/j.jjcc.2019.12.006"},{"key":"37","doi-asserted-by":"crossref","unstructured":"37. Soeda T, Uemura S, Park SJ, <i>et al<\/i>. Incidence and clinical significance of poststent optical coherence tomography findings: one-year follow-up study from a multicenter registry. Circulation 2015; 132: 1020-9.","DOI":"10.1161\/CIRCULATIONAHA.114.014704"},{"key":"38","doi-asserted-by":"crossref","unstructured":"38. Hansi C, Arab A, Rzany A, Ahrens I, Bode C, Hehrlein C. Differences of platelet adhesion and thrombus activation on amorphous silicon carbide, magnesium alloy, stainless steel, and cobalt chromium stent surfaces. Catheter Cardiovasc Interv 2009; 73: 488-96.","DOI":"10.1002\/ccd.21834"},{"key":"39","doi-asserted-by":"crossref","unstructured":"39. G\u00e9n\u00e9reux P, Giustino G, Witzenbichler B, <i>et al<\/i>. Incidence, predictors, and impact of post-discharge bleeding after percutaneous coronary intervention. J Am Coll Cardiol 2015; 66: 1036-45.","DOI":"10.1016\/j.jacc.2015.06.1323"},{"key":"40","doi-asserted-by":"crossref","unstructured":"40. Knuuti J, Wijns W, Saraste A, <i>et al<\/i>. 2019 ESC Guidelines for the diagnosis and management of chronic coronary syndromes. Eur Heart J 2020; 41: 407-77.","DOI":"10.1093\/eurheartj\/ehz425"},{"key":"41","doi-asserted-by":"crossref","unstructured":"41. Watanabe H, Domei T, Morimoto T, <i>et al<\/i>. Effect of 1-month dual antiplatelet therapy followed by clopidogrel vs 12-month dual antiplatelet therapy on cardiovascular and bleeding events in patients receiving PCI: the STOPDAPT-2 randomized clinical trial. JAMA 2019; 321: 2414-27.","DOI":"10.1001\/jama.2019.8145"}],"container-title":["International Heart Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ihj\/62\/3\/62_20-627\/_pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,11]],"date-time":"2021-06-11T02:26:41Z","timestamp":1623378401000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.jstage.jst.go.jp\/article\/ihj\/62\/3\/62_20-627\/_article"}},"subtitle":["Sequential Optical Coherence Tomography Study"],"short-title":[],"issued":{"date-parts":[[2021,5,29]]},"references-count":41,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1536\/ihj.20-627","relation":{},"ISSN":["1349-2365","1349-3299"],"issn-type":[{"value":"1349-2365","type":"print"},{"value":"1349-3299","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5,29]]}}}