{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T00:59:58Z","timestamp":1790211598934,"version":"4.1.0"},"reference-count":18,"publisher":"American Academy of Pediatrics (AAP)","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND<\/jats:title>\n                    <jats:p>Transcutaneous bilirubin (TcB) screening in the newborn nursery (NBN) is noninvasive and appropriate for most infants; however, reported rates of total serum bilirubin (TSB) measurement remain at 17% to 30%.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>From January to December 2024, 17.2% of infants solely admitted to our NBN received any TSB test, but only 45.3% of TSB measurements were concordant with the American Academy of Pediatrics guidelines. Our aim was to decrease the percentage of infants receiving any TSB measurement from 17% to 12% within 6\u00a0months by increasing the percentage of guideline-concordant TSB measurements from 45% to 75%.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>METHODS<\/jats:title>\n                    <jats:p>Interventions included the following: (1) updated nursing protocol for bilirubin screening, (2) NBN physician manual chart review, (3) nursing education sessions, (4) NBN physician meeting to discuss ongoing barriers and potential practice changes, and (5) ongoing reinforcement of TSB indications. The outcome measure was the percentage of infants receiving any TSB test. Process measures included percentage of guideline-concordant TSB tests and TSB tests without a preceding TcB screen (unless on\/post phototherapy). Balancing measures included readmissions for phototherapy and escalation of care on readmission. Data were analyzed using statistical process control.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>The percentage of infants receiving any TSB test decreased from 17.2% to 11.2%. The percentage of guideline-concordant TSB tests increased from 45.3% to 85.1%, and TSB tests without a TcB screen decreased from 24.4% to 7.1%. There was no significant change in readmission rate.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION<\/jats:title>\n                    <jats:p>Using quality improvement methodology to increase guideline-concordant TSB tests decreased the percentage of infants receiving any TSB test. This outcome is beneficial for patient-centered care, with decreased painful procedures, and for resource use.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1542\/hpeds.2026-009508","type":"journal-article","created":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T00:03:14Z","timestamp":1790208194000},"source":"Crossref","is-referenced-by-count":0,"title":["Reducing Serum Bilirubin Measurements in a Newborn Nursery Using Quality Improvement Methodology"],"prefix":"10.1542","author":[{"given":"Juniper L.","family":"Burch","sequence":"first","affiliation":[{"name":"1Division of Newborn Medicine, Mass General Brigham for Children, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Regina","family":"Joseph","sequence":"additional","affiliation":[{"name":"2Mass General Hospital, Boston Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tamra","family":"Ouellette","sequence":"additional","affiliation":[{"name":"2Mass General Hospital, Boston Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elena","family":"Luo","sequence":"additional","affiliation":[{"name":"3Harvard University, Cambridge, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leela","family":"Sarathy","sequence":"additional","affiliation":[{"name":"1Division of Newborn Medicine, Mass General Brigham for Children, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"417","published-online":{"date-parts":[[2026,9,24]]},"reference":[{"issue":"3","key":"2026092320030847000_r1","doi-asserted-by":"crossref","first-page":"e2022058859","DOI":"10.1542\/peds.2022-058859","article-title":"Clinical practice guideline revision: management of hyperbilirubinemia in the newborn infant 35 or more weeks of gestation","volume":"150","author":"Kemper","year":"2022","journal-title":"Pediatrics."},{"issue":"5","key":"2026092320030847000_r2","first-page":"CD012660","article-title":"Transcutaneous bilirubinometry versus total serum bilirubin measurement for newborns","volume":"5","author":"Okwundu","year":"2023","journal-title":"Cochrane Database Syst Rev."},{"issue":"6","key":"2026092320030847000_r3","doi-asserted-by":"crossref","first-page":"1264","DOI":"10.1542\/peds.107.6.1264","article-title":"Transcutaneous Bilirubin Measurement: A Multicenter Evaluation of a New Device","volume":"107","author":"Rubaltelli","year":"2001","journal-title":"Pediatrics."},{"key":"2026092320030847000_r4","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.jpeds.2020.08.079","article-title":"Decision Accuracy and Safety of Transcutaneous Bilirubin Screening at Intermountain Healthcare","volume":"228","author":"Konana","year":"2021","journal-title":"J Pediatr."},{"issue":"6","key":"2026092320030847000_r5","doi-asserted-by":"crossref","first-page":"e20162414","DOI":"10.1542\/peds.2016-2414","article-title":"Transcutaneous bilirubinometry in jaundiced neonates: A randomized controlled trial","volume":"138","author":"van den Esker-Jonker","year":"2016","journal-title":"Pediatrics."},{"issue":"4","key":"2026092320030847000_r6","doi-asserted-by":"crossref","first-page":"e2023063323","DOI":"10.1542\/peds.2023-063323","article-title":"Bilirubin Measurement and Phototherapy Use After the AAP 2022 Newborn Hyperbilirubinemia Guideline","volume":"153","author":"Sarathy","year":"2024","journal-title":"Pediatrics."},{"issue":"7","key":"2026092320030847000_r7","doi-asserted-by":"crossref","first-page":"582","DOI":"10.1542\/hpeds.2024-008180","article-title":"Quality Improvement Reduces Excessive Serum Bilirubin Laboratory Draws in a Community Hospital Nursery","volume":"15","author":"Pak","year":"2025","journal-title":"Hosp Pediatr."},{"issue":"6","key":"2026092320030847000_r8","doi-asserted-by":"crossref","first-page":"e2022059474","DOI":"10.1542\/peds.2022-059474","article-title":"Decreasing Bilirubin Serum Tests in Healthy Newborns During Birth Hospitalization","volume":"151","author":"Sukkar","year":"2023","journal-title":"Pediatrics."},{"key":"2026092320030847000_r9","doi-asserted-by":"crossref","first-page":"30","DOI":"10.3389\/fped.2020.00030","article-title":"Early Neonatal Pain-A Review of Clinical and Experimental Implications on Painful Conditions Later in Life","volume":"8","author":"Williams","year":"2020","journal-title":"Front Pediatr."},{"issue":"3","key":"2026092320030847000_r10","doi-asserted-by":"crossref","first-page":"E285","DOI":"10.9778\/cmajo.20170158","article-title":"Cost savings with transcutaneous screening versus total serum bilirubin measurement for newborn jaundice in hospital and community settings: a cost-minimization analysis","volume":"6","author":"McClean","year":"2018","journal-title":"CMAJ Open."},{"issue":"3","key":"2026092320030847000_r11","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1016\/j.clp.2017.05.011","article-title":"Using Statistical Process Control to Drive Improvement in Neonatal Care: A Practical Introduction to Control Charts","volume":"44","author":"Gupta","year":"2017","journal-title":"Clin Perinatol."},{"issue":"6","key":"2026092320030847000_r12","doi-asserted-by":"crossref","first-page":"458","DOI":"10.1136\/qhc.12.6.458","article-title":"Statistical process control as a tool for research and healthcare improvement","volume":"12","author":"Benneyan","year":"2003","journal-title":"Qual Saf Health Care."},{"issue":"2","key":"2026092320030847000_r13","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1016\/j.pain.2009.02.014","article-title":"Neonatal pain, parenting stress and interaction, in relation to cognitive and motor development at 8 and 18\u00a0months in preterm infants","volume":"143","author":"Grunau","year":"2009","journal-title":"Pain."},{"issue":"4","key":"2026092320030847000_r14","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/j.cnc.2018.07.013","article-title":"Neonatal Pain: Perceptions and Current Practice","volume":"30","author":"Perry","year":"2018","journal-title":"Crit Care Nurs Clin North Am."},{"issue":"3","key":"2026092320030847000_r15","doi-asserted-by":"crossref","first-page":"357","DOI":"10.1111\/ped.14142","article-title":"Neonatal pain response to automatic lancet versus needle heel-prick blood sampling: A prospective randomized controlled clinical trial","volume":"62","author":"Goto","year":"2020","journal-title":"Pediatr Int."},{"issue":"4","key":"2026092320030847000_r16","doi-asserted-by":"crossref","first-page":"e335","DOI":"10.1097\/pq9.0000000000000335","article-title":"Reducing Outpatient Infant Blood Draws with Transcutaneous Measurement of Bilirubin","volume":"5","author":"Kilmartin","year":"2020","journal-title":"Pediatr Qual Saf."},{"issue":"7","key":"2026092320030847000_r17","doi-asserted-by":"crossref","first-page":"957","DOI":"10.1038\/s41372-025-02242-z","article-title":"End-tidal carbon monoxide for routine monitoring of significant hemolysis in the management of newborn hyperbilirubinemia","volume":"45","author":"Wells","year":"2025","journal-title":"J Perinatol."},{"issue":"6","key":"2026092320030847000_r18","doi-asserted-by":"crossref","first-page":"e1596","DOI":"10.1542\/peds.2011-2726","article-title":"Safely doing less: a missing component of the patient safety dialogue","volume":"128","author":"Schroeder","year":"2011","journal-title":"Pediatrics."}],"container-title":["Hospital Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/publications.aap.org\/hospitalpediatrics\/article-pdf\/doi\/10.1542\/hpeds.2026-009508\/1967643\/hosppeds.2026009508.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/publications.aap.org\/hospitalpediatrics\/article-pdf\/doi\/10.1542\/hpeds.2026-009508\/1967643\/hosppeds.2026009508.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T00:03:16Z","timestamp":1790208196000},"score":1,"resource":{"primary":{"URL":"https:\/\/publications.aap.org\/hospitalpediatrics\/article\/doi\/10.1542\/hpeds.2026-009508\/210080\/Reducing-Serum-Bilirubin-Measurements-in-a-Newborn"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,9,24]]},"references-count":18,"URL":"https:\/\/doi.org\/10.1542\/hpeds.2026-009508","relation":{},"ISSN":["2154-1663","2154-1671"],"issn-type":[{"value":"2154-1663","type":"print"},{"value":"2154-1671","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,9,24]]},"article-number":"e2026009508"}}