{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T18:09:11Z","timestamp":1787508551403,"version":"build-2736575974"},"reference-count":12,"publisher":"American Academy of Pediatrics (AAP)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2004,2,1]]},"abstract":"<jats:p>Objective. Patient-activated transtelephonic electrocardiographic event monitors (TTMs) are often used for the evaluation of children and adolescents with suspected arrhythmias. Since their introduction 25 years ago, there has been little inquiry quantifying the usefulness of TTMs for pediatric patients. The objective of this study was to measure the utility of TTMs for children and adolescents with symptoms of a possible cardiac rhythm disturbance.<\/jats:p>\n                  <jats:p>Methods. Medical records of all patients who received TTMs from C.S. Mott Children\u2019s Hospital Electrocardiography Laboratory between February 1, 1993, and October 31, 2000, were reviewed. Patients with pacemakers, known arrhythmias, or age older than 18 years were excluded. Indications for monitoring included palpitations with or without other symptoms (N = 420), chest discomfort (N = 43), and presyncope or syncope (N = 32).<\/jats:p>\n                  <jats:p>Results. A total of 495 studies (patient mean age: 10.2 \u00b1 4.3 years; range: 0.1\u201317.9 years; 48% male) met inclusion criteria. Monitoring was performed for 1 to 1021 consecutive days (mean: 103 \u00b1 97). Fifty-two percent (N = 257) of patients failed to transmit an electrocardiogram while experiencing symptoms. Fewer boys transmitted electrocardiograms (N = 100\/238). Of 238 symptomatic patients, 15% (N = 35; mean age: 11.4 \u00b1 4.7 years; range: 0.1\u201317.4 years; 51% male) had supraventricular tachycardia (SVT). No other significant arrhythmia that may warrant treatment was identified. All patients with SVT had palpitations. No patients with isolated chest discomfort, presyncope, or syncope had SVT (N = 75). SVT was documented more frequently in patients with postevent (N = 35\/464) than loop recorders (N = 0\/31). Of those with SVT, 71% (N = 25) and 91% (N = 33) transmitted events within 4 and 16 weeks, respectively. Follow-up for 1 to 108 months (mean: 32 \u00b1 25; median: 26) in 53% (243 of 460) of patients without SVT uncovered a 3% (N = 7) rate of subsequent SVT detection. The overall sensitivity of the TTM test was 83% (35 of 42) for detection of SVT. The sensitivity of studies theoretically limited to 4 and 16 weeks would be 60% (25 of 42) and 79% (33 of 42), respectively. The negative predictive value of the TTM study was 99% in our patient population. The negative predictive value of tests theoretically limited to 4 and 16 weeks would be 96% and 98%, respectively. TTM studies of 2 weeks\u2019 duration were most cost-effective in terms of total diagnostic yield. In contrast, studies of 4 weeks\u2019 duration were most cost-efficient for SVT detection.<\/jats:p>\n                  <jats:p>Conclusions. TTMs are useful for the evaluation of children and adolescents with palpitations but not with isolated chest pain, syncope, or presyncope. In this study, girls were more likely to transmit events. The sensitivity of TTMs for detection of SVT was 83%. The negative predictive value of the TTM test was 99%. Monitoring for longer than 16 weeks did not increase test sensitivity. Studies of 4 weeks\u2019 duration proved most cost-effective for SVT detection.<\/jats:p>","DOI":"10.1542\/peds.113.2.248","type":"journal-article","created":{"date-parts":[[2004,8,13]],"date-time":"2004-08-13T20:53:04Z","timestamp":1092430384000},"page":"248-251","source":"Crossref","is-referenced-by-count":44,"title":["Transtelephonic Electrocardiographic Monitors for Evaluation of Children and Adolescents With Suspected Arrhythmias"],"prefix":"10.1542","volume":"113","author":[{"given":"Elizabeth Vickers","family":"Saarel","sequence":"first","affiliation":[{"name":"From the Division of Pediatric Cardiology, Department of Pediatrics, University of Michigan Health System, Ann Arbor, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher B.","family":"Stefanelli","sequence":"additional","affiliation":[{"name":"From the Division of Pediatric Cardiology, Department of Pediatrics, University of Michigan Health System, Ann Arbor, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter S.","family":"Fischbach","sequence":"additional","affiliation":[{"name":"From the Division of Pediatric Cardiology, Department of Pediatrics, University of Michigan Health System, Ann Arbor, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gerald A.","family":"Serwer","sequence":"additional","affiliation":[{"name":"From the Division of Pediatric Cardiology, Department of Pediatrics, University of Michigan Health System, Ann Arbor, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amnon","family":"Rosenthal","sequence":"additional","affiliation":[{"name":"From the Division of Pediatric Cardiology, Department of Pediatrics, University of Michigan Health System, Ann Arbor, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"II","given":"Macdonald","family":"Dick","sequence":"additional","affiliation":[{"name":"From the Division of Pediatric Cardiology, Department of Pediatrics, University of Michigan Health System, Ann Arbor, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"417","published-online":{"date-parts":[[2004,2,1]]},"reference":[{"key":"2021121011023367800_R1","doi-asserted-by":"crossref","unstructured":"Dick M 2nd, McFadden D, Crowley D, Rosenthal A. Diagnosis and management of cardiac rhythm disorders by transtelephonic electrocardiography in infants and children. J Pediatr.1979;94:612\u2013615","DOI":"10.1016\/S0022-3476(79)80028-1"},{"key":"2021121011023367800_R2","doi-asserted-by":"crossref","unstructured":"Goldstein MA, Hesslein P, Dunnigan A. Efficacy of transtelephonic electrocardiographic monitoring in pediatric patients. Am J Dis Child.1990;144:178\u2013182","DOI":"10.1001\/archpedi.1990.02150260058028"},{"key":"2021121011023367800_R3","doi-asserted-by":"crossref","unstructured":"Williams RL. Use of transtelephonic electrocardiography in patients with symptoms suggesting cardiac arrhythmia. Pediatrics.1978;61:493\u2013495","DOI":"10.1542\/peds.61.3.493"},{"key":"2021121011023367800_R4","doi-asserted-by":"crossref","unstructured":"Fyfe DA, Holmes DR Jr, Neubauer SA, Feldt RH. Transtelephonic monitoring in pediatric patients with clinically suspected arrhythmias. Clin Pediatr (Phila).1984;23:139\u2013143","DOI":"10.1177\/000992288402300302"},{"key":"2021121011023367800_R5","doi-asserted-by":"crossref","unstructured":"Karpawich PP, Cavitt DL, Sugalski JS. Ambulatory arrhythmia screening in symptomatic children and young adults: comparative effectiveness of Holter and telephone event recordings. Pediatr Cardiol.1993;14:147\u2013150","DOI":"10.1007\/BF00795642"},{"key":"2021121011023367800_R6","doi-asserted-by":"crossref","unstructured":"Zimetbaum P, Kim KY, Ho KK, Zebede J, Josephson ME, Goldberger AL. Utility of patient-activated cardiac event recorders in general clinical practice. Am J Cardiol.1997;79:371\u2013372","DOI":"10.1016\/S0002-9149(96)00766-7"},{"key":"2021121011023367800_R7","doi-asserted-by":"crossref","unstructured":"Fogel RI, Evans JJ, Prystowsky EN. Utility and cost of event recorders in the diagnosis of palpitations, presyncope, and syncope. Am J Cardiol.1997;79:207\u2013208","DOI":"10.1016\/S0002-9149(96)00717-5"},{"key":"2021121011023367800_R8","doi-asserted-by":"crossref","unstructured":"Wu J, Kessler DK, Chakko S, Kessler KM. A cost-effectiveness strategy for transtelephonic arrhythmia monitoring. Am J Cardiol.1995;75:184\u2013185","DOI":"10.1016\/S0002-9149(00)80075-2"},{"key":"2021121011023367800_R9","doi-asserted-by":"crossref","unstructured":"Kinlay S, Leitch JW, Neil A, Chapman BL, Hardy DB, Fletcher PJ. Cardiac event recorders yield more diagnoses and are more cost-effective than 48-hour Holter monitoring in patients with palpitations. Ann Intern Med.1996;124:16\u201320","DOI":"10.7326\/0003-4819-124-1_Part_1-199601010-00003"},{"key":"2021121011023367800_R10","doi-asserted-by":"crossref","unstructured":"Zimetbaum PJ, Kim KY, Josephson ME, Goldberger AL, Cohen DJ. Diagnostic yield and optimal duration of continuous-loop event monitoring for the diagnosis of palpitations: a cost-effectiveness analysis. Ann Intern Med.1998;128:890\u2013895","DOI":"10.7326\/0003-4819-128-11-199806010-00002"},{"key":"2021121011023367800_R11","doi-asserted-by":"crossref","unstructured":"Case CL. Diagnosis and treatment of pediatric arrhythmias. Pediatr Clin North Am.1999;46:347\u2013354","DOI":"10.1016\/S0031-3955(05)70122-X"},{"key":"2021121011023367800_R12","doi-asserted-by":"crossref","unstructured":"Linzer M, Pritchett EL, Pontinen M, McCarthy E, Divine GW. Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope. Am J Cardiol.1990;66:214\u2013219","DOI":"10.1016\/0002-9149(90)90591-N"}],"container-title":["Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/publications.aap.org\/pediatrics\/article-pdf\/113\/2\/248\/1011279\/zpe00204000248.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/publications.aap.org\/pediatrics\/article-pdf\/113\/2\/248\/1011279\/zpe00204000248.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,12,10]],"date-time":"2021-12-10T18:58:24Z","timestamp":1639162704000},"score":1,"resource":{"primary":{"URL":"https:\/\/publications.aap.org\/pediatrics\/article\/113\/2\/248\/66894\/Transtelephonic-Electrocardiographic-Monitors-for"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,2,1]]},"references-count":12,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2004,2,1]]},"published-print":{"date-parts":[[2004,2,1]]}},"URL":"https:\/\/doi.org\/10.1542\/peds.113.2.248","relation":{},"ISSN":["0031-4005","1098-4275"],"issn-type":[{"value":"0031-4005","type":"print"},{"value":"1098-4275","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,2,1]]}}}