{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T13:44:58Z","timestamp":1790775898043,"version":"4.1.0"},"reference-count":34,"publisher":"American Academy of Pediatrics (AAP)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2004,6,1]]},"abstract":"<jats:p>Objective. The objective of this study was to evaluate the Minolta\/Hill-Rom Air-Shields Transcutaneous Jaundice Meter model JM-103.<\/jats:p>\n                  <jats:p>Methods. We studied a convenience sample of 849 newborns \u226535 weeks of gestation in 3 hospitals. These infants had total serum bilirubin (TSB) levels measured on clinical indication, and transcutaneous bilirubin (TcB) levels were obtained within 1 hour of the TSB levels. The population was 59.2% white, 29.8% black, 4.5% East Asian, 3.8% Middle Eastern, 1.6% Indian\/Pakistani, and 1.1% Hispanic.<\/jats:p>\n                  <jats:p>Results. There was a close correlation between TSB and TcB values in all of the population groups: white (n = 503, r = .949); black (n = 253, r = .822); and East Asian, Indian\/Pakistani, and Hispanic (n = 93, r = .926). In the black population, the correlation was less close than in the other groups, and differences between the TcB and TSB measurements tended to increase with rising TSB values. JM-103 values differed from TSB values by 3 mg\/dL or more in 2% of white, 3.2% of other, and 17.4% of black infants. In these black infants, the JM-103 value was always greater than the TSB value.<\/jats:p>\n                  <jats:p>Conclusions. We conclude that TcB measurements using the JM-103 jaundice meter correlate very closely with TSB levels over the range of TSB encountered in this study. Because only 3.3% of our infants had TSB values &amp;gt;15 mg\/dL (257 \u03bcmol\/L), more data are needed in this range of TSB concentration. The correlation in black infants is not as close as in other groups, but because the tendency in blacks is for the JM-103 to overestimate serum bilirubin levels, dangerous clinical errors are unlikely to occur. The measurement technique is rapid and simple, and it is easy to perform repeated measurements over time, thus reducing the likelihood of error. TcB measurements with the JM-103 jaundice meter should obviate the need for most serum bilirubin levels in newborn infants \u226535 weeks of gestation, although serum bilirubin measurements are still required when treatment with phototherapy or exchange transfusion is being considered.<\/jats:p>","DOI":"10.1542\/peds.113.6.1628","type":"journal-article","created":{"date-parts":[[2004,8,13]],"date-time":"2004-08-13T20:53:04Z","timestamp":1092430384000},"page":"1628-1635","source":"Crossref","is-referenced-by-count":156,"title":["Evaluation of a New Transcutaneous Bilirubinometer"],"prefix":"10.1542","volume":"113","author":[{"given":"M. Jeffrey","family":"Maisels","sequence":"first","affiliation":[{"name":"Department of Pediatrics, William Beaumont Hospital, Royal Oak, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"suffix":"Jr","given":"Enrique M.","family":"Ostrea","sequence":"additional","affiliation":[{"name":"Division of Neonatology, Hutzel Hospital, Detroit, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Suzanne","family":"Touch","sequence":"additional","affiliation":[{"name":"Division of Neonatology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah E.","family":"Clune","sequence":"additional","affiliation":[{"name":"West Bloomfield, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eugene","family":"Cepeda","sequence":"additional","affiliation":[{"name":"Division of Neonatology, Hutzel Hospital, Detroit, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth","family":"Kring","sequence":"additional","affiliation":[{"name":"Department of Pediatrics, William Beaumont Hospital, Royal Oak, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Karin","family":"Gracey","sequence":"additional","affiliation":[{"name":"Division of Neonatology, Hutzel Hospital, Detroit, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheryl","family":"Jackson","sequence":"additional","affiliation":[{"name":"Division of Neonatology, Hutzel Hospital, Detroit, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deborah","family":"Talbot","sequence":"additional","affiliation":[{"name":"Division of Neonatology, Hutzel Hospital, Detroit, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raywin","family":"Huang","sequence":"additional","affiliation":[{"name":"Research Institute, William Beaumont Hospital, Royal Oak, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"417","published-online":{"date-parts":[[2004,6,1]]},"reference":[{"key":"2021121006330369700_R1","doi-asserted-by":"crossref","unstructured":"Maisels MJ, Conrad S. Transcutaneous bilirubin measurements in full-term infants. Pediatrics.1982;70:464\u2013467","DOI":"10.1542\/peds.70.3.464"},{"key":"2021121006330369700_R2","doi-asserted-by":"crossref","unstructured":"Schumacher RE. Non-invasive measurements of bilirubin in the newborn. Clin Perinatol.1990;17:417\u2013435","DOI":"10.1016\/S0095-5108(18)30576-1"},{"key":"2021121006330369700_R3","doi-asserted-by":"crossref","unstructured":"Maisels MJ, Kring E. Transcutaneous bilirubinometry decreases the need for serum bilirubin measurements and saves money. Pediatrics.1997;99:599\u2013601","DOI":"10.1542\/peds.99.4.599"},{"key":"2021121006330369700_R4","doi-asserted-by":"crossref","unstructured":"Briscoe L, Clark S, Yoxall C. Can transcutaneous bilirubinometry reduce the need for blood tests in jaundiced full term babies?Arch Dis Child Fetal Neonatal Ed.2002;86:F190\u2013F192","DOI":"10.1136\/fn.86.3.F190"},{"key":"2021121006330369700_R5","doi-asserted-by":"crossref","unstructured":"Robertson A, Kazmierczak S, Vos P. Improved transcutaneous bilirubinometry: comparison of SpectRx Bilicheck and Minolta jaundice meter JM-102 for estimating total serum bilirubin in a normal newborn population. J Perinatol.2002;22:12\u201314","DOI":"10.1038\/sj.jp.7210592"},{"key":"2021121006330369700_R6","doi-asserted-by":"crossref","unstructured":"Yasuda S, Itoh S, Isobe K, et al. New transcutaneous jaundice device with two optical paths. J Perinat Med.2003;31:81\u201388","DOI":"10.1515\/JPM.2003.012"},{"key":"2021121006330369700_R7","doi-asserted-by":"crossref","unstructured":"Rubaltelli FF, Gourley GR, Loskamp N, et al. Transcutaneous bilirubin measurement: a multicenter evaluation of a new device. Pediatrics.2001;107:1264\u20131271","DOI":"10.1542\/peds.107.6.1264"},{"key":"2021121006330369700_R8","doi-asserted-by":"crossref","unstructured":"Bhutani VK, Gourley GR, Adler S, et al. Noninvasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia. Pediatrics.2000;106(2). Available at: pediatrics.org\/cgi\/content\/full\/106\/2\/e17","DOI":"10.1542\/peds.106.2.e17"},{"key":"2021121006330369700_R9","doi-asserted-by":"crossref","unstructured":"Ebbesen F, Rasmussen LM, Wimberley PD. A new transcutaneous bilirubinometer, Bilicheck, used in the neonatal intensive care unit and the maternity ward. Acta Paediatr.2002;91:203\u2013211","DOI":"10.1111\/j.1651-2227.2002.tb01696.x"},{"key":"2021121006330369700_R10","doi-asserted-by":"crossref","unstructured":"Engle WD, Jackson GL, Sendelbach D, Manning D, Frawley W. Assessment of a transcutaneous device in the evaluation of neonatal hyperbilirubinemia in a primarily Hispanic population. Pediatrics.2002;110:61\u201367","DOI":"10.1542\/peds.110.1.61"},{"key":"2021121006330369700_R11","doi-asserted-by":"crossref","unstructured":"Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet.1986;1:307\u2013310","DOI":"10.1016\/S0140-6736(86)90837-8"},{"key":"2021121006330369700_R12","doi-asserted-by":"crossref","unstructured":"Bradley EL, Blackwood LG. Comparing paired data: a simultaneous test of means and variances. Am Stat.1989;43:234\u2013235","DOI":"10.1080\/00031305.1989.10475665"},{"key":"2021121006330369700_R13","doi-asserted-by":"crossref","unstructured":"Maisels MJ, Newman TB. Kernicterus in otherwise healthy, breast-fed term newborns. Pediatrics.1995;96:730\u2013733","DOI":"10.1542\/peds.96.4.730"},{"key":"2021121006330369700_R14","doi-asserted-by":"crossref","unstructured":"Johnson LH, Bhutani VK, Brown AK. System-based approach to management of neonatal jaundice and prevention of kernicterus. J Pediatr.2002;140:396\u2013403","DOI":"10.1067\/mpd.2002.123098"},{"key":"2021121006330369700_R15","doi-asserted-by":"crossref","unstructured":"American Academy of Pediatrics Subcommittee on Neonatal Hyperbilirubinemia. Neonatal jaundice and kernicterus. Pediatrics.2001;108:763\u2013765","DOI":"10.1542\/peds.108.3.763"},{"key":"2021121006330369700_R16","doi-asserted-by":"crossref","unstructured":"Bhutani VK, Johnson L, Sivieri EM. Predictive ability of a predischarge hour-specific serum bilirubin for subsequent significant hyperbilirubinemia in healthy-term and near-term newborns. Pediatrics.1999;103:6\u201314","DOI":"10.1542\/peds.103.1.6"},{"key":"2021121006330369700_R17","doi-asserted-by":"crossref","unstructured":"Maisels MJ, Newman TB. Jaundice in full term and near-term babies who leave the hospital within 36 hours. The pediatrician's nemesis. Clin Perinatol.1998;25:295\u2013302","DOI":"10.1016\/S0095-5108(18)30116-7"},{"key":"2021121006330369700_R18","doi-asserted-by":"crossref","unstructured":"Davidson LT, Merritt KK, Weech AA. Hyperbilirubinemia in the newborn. Am J Dis Child.1941;61:958\u2013980","DOI":"10.1001\/archpedi.1941.02000110046005"},{"key":"2021121006330369700_R19","doi-asserted-by":"crossref","unstructured":"Moyer VA, Ahn C, Sneed S. Accuracy of clinical judgment in neonatal jaundice. Arch Pediatr Adolesc Med.2000;154:391\u2013394","DOI":"10.1001\/archpedi.154.4.391"},{"key":"2021121006330369700_R20","doi-asserted-by":"crossref","unstructured":"Tayaba R, Gribetz D, Gribetz I, Holzman IR. Noninvasive estimation of serum bilirubin. Pediatrics1998;102(3). Available at: pediatrics.org\/cgi\/content\/full\/102\/3\/e28","DOI":"10.1542\/peds.102.3.e28"},{"key":"2021121006330369700_R21","doi-asserted-by":"crossref","unstructured":"Wong CM, van Dijk PJE, Laing IA. A comparison of transcutaneous bilirubinometers: Spectrx Bilicheck versus Minolta Airshields. Arch Dis Child Fetal Neonatal Ed.2002;87:F137\u2013F140","DOI":"10.1136\/fn.87.2.F137"},{"key":"2021121006330369700_R22","doi-asserted-by":"crossref","unstructured":"Hegyi T, Hiatt IM, Indyk L. Transcutaneous bilirubinometry. I. Correlations in term infants. J Pediatr.1981;98:454\u2013457","DOI":"10.1016\/S0022-3476(81)80721-4"},{"key":"2021121006330369700_R23","unstructured":"Barroeta J, Bhutani VK, Husson M, Dalin C, Johnson LH. Study comparing the Bilicheck and the new Minolta JM-103 transcutaneous bilirubin analyzers in hospitalized infants. Pediatr Res.2003;53:364A"},{"key":"2021121006330369700_R24","doi-asserted-by":"crossref","unstructured":"Linn S, Schoenbaum SC, Monson RR, et al. Epidemiology of neonatal hyperbilirubinemia. Pediatrics.1985;75:770\u2013774","DOI":"10.1542\/peds.75.4.770"},{"key":"2021121006330369700_R25","doi-asserted-by":"crossref","unstructured":"Newman TB, Easterling MJ, Goldman ES, Stevenson DK. Laboratory evaluation of jaundiced newborns: frequency, cost and yield. Am J Dis Child.1990;144:364\u2013368","DOI":"10.1001\/archpedi.1990.02150270114039"},{"key":"2021121006330369700_R26","doi-asserted-by":"crossref","unstructured":"Vreman HJ, Verter J, Oh W, et al. Interlaboratory variability of bilirubin measurements. Clin Chem.1996;42:869\u2013873","DOI":"10.1093\/clinchem\/42.6.869"},{"key":"2021121006330369700_R27","doi-asserted-by":"crossref","unstructured":"Maisels MJ, Gifford K, Antle CE, et al. Normal serum bilirubin levels in the newborn and the effect of breast feeding. Pediatrics.1986;78:837\u2013843","DOI":"10.1542\/peds.78.5.837"},{"key":"2021121006330369700_R28","doi-asserted-by":"crossref","unstructured":"Stevenson DK, Fanaroff AA, Maisels MJ, et al. Prediction of hyperbilirubinemia in near term and term infants. Pediatrics.2001;108(2):31\u201339","DOI":"10.1542\/peds.108.1.31"},{"key":"2021121006330369700_R29","doi-asserted-by":"crossref","unstructured":"Alpay F, Sarici U, Tosuncuk HD, et al. The value of first-day bilirubin measurement in predicting the development of significant hyperbilirubinemia in healthy term newborns. Pediatrics.2000;106. Available at: pediatrics.org\/cgi\/content\/full\/106\/2\/e16","DOI":"10.1542\/peds.106.2.e16"},{"key":"2021121006330369700_R30","doi-asserted-by":"crossref","unstructured":"Carbonell X, Botet F, Figueras J, Riu-Godo A. Prediction of hyperbilirubinaemia in the healthy term newborn. Acta Paediatr.2001;90:166\u2013170","DOI":"10.1111\/j.1651-2227.2001.tb00279.x"},{"key":"2021121006330369700_R31","doi-asserted-by":"crossref","unstructured":"Kaplan M, Hammerman C, Feldman R, et al. Predischarge bilirubin screening in glucose-6-phosphate dehydrogenase-deficient neonates. Pediatrics.2000;105:533\u2013537","DOI":"10.1542\/peds.105.3.533"},{"key":"2021121006330369700_R32","doi-asserted-by":"crossref","unstructured":"Tan KL, Dong F. Transcutaneous bilirubinometry during and after phototherapy. Acta Paediatr.2003;92:327\u2013331","DOI":"10.1111\/j.1651-2227.2003.tb00554.x"},{"key":"2021121006330369700_R33","doi-asserted-by":"crossref","unstructured":"Newman TB, Xiong B, Gonzales VM, Escobar GJ. Prediction and prevention of extreme neonatal hyperbilirubinemia in a mature health maintenance organization. Arch Pediatr Adolesc Med.2000;154:1140\u20131147","DOI":"10.1001\/archpedi.154.11.1140"},{"key":"2021121006330369700_R34","doi-asserted-by":"crossref","unstructured":"Maisels MJ, Kring EA. Length of stay, jaundice and hospital readmission. Pediatrics.1998;101:995\u2013998","DOI":"10.1542\/peds.101.6.995"}],"container-title":["Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/publications.aap.org\/pediatrics\/article-pdf\/113\/6\/1628\/1004337\/zpe00604001628.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/publications.aap.org\/pediatrics\/article-pdf\/113\/6\/1628\/1004337\/zpe00604001628.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,12,10]],"date-time":"2021-12-10T10:03:55Z","timestamp":1639130635000},"score":1,"resource":{"primary":{"URL":"https:\/\/publications.aap.org\/pediatrics\/article\/113\/6\/1628\/64373\/Evaluation-of-a-New-Transcutaneous-Bilirubinometer"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2004,6,1]]},"references-count":34,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2004,6,1]]},"published-print":{"date-parts":[[2004,6,1]]}},"URL":"https:\/\/doi.org\/10.1542\/peds.113.6.1628","relation":{},"ISSN":["0031-4005","1098-4275"],"issn-type":[{"value":"0031-4005","type":"print"},{"value":"1098-4275","type":"electronic"}],"subject":[],"published":{"date-parts":[[2004,6,1]]}}}