{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T23:09:47Z","timestamp":1761174587795,"version":"3.40.5"},"reference-count":19,"publisher":"American Academy of Pediatrics (AAP)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2010,7,1]]},"abstract":"<jats:sec><jats:title>OBJECTIVE:<\/jats:title><jats:p>The goal was to determine the interchangeability of peripheral venous catheter (PVC) and venipuncture blood sampling (BS).<\/jats:p><\/jats:sec><jats:sec><jats:title>METHODS:<\/jats:title><jats:p>Paired blood samples from hospitalized children were obtained through venipuncture and from existing PVCs, following discard of 2 mL of blood. Comparisons of 9 complete blood count indices (white and red blood cell counts, hemoglobin and hematocrit levels, mean corpuscular volume, mean corpuscular hemoglobin level, red blood cell distribution width, platelet count, and mean platelet volume) and 5 basic chemical analysis indices (sodium, potassium, glucose, chloride, and urea levels) were performed, and hemolysis was documented.<\/jats:p><\/jats:sec><jats:sec><jats:title>RESULTS:<\/jats:title><jats:p>Irrespective of gauge, blood samples were obtained successfully from 40 (85.1%) of 47 PVCs, with no abnormal hemolysis. BS through venipuncture took longer than BS from PVCs (175.8 \u00b1 229.6 vs 104.5 \u00b1 53.4 seconds; P = .053) and was associated with significantly more distress\/crying (73.1% vs 0%; P &amp;lt; .001). There were no significant differences between venipuncture and PVC samples (paired t test). Twenty-one (6%) of 348 pairs analyzed with the Clinical Laboratory Improvement Amendment standards fell outside the range of acceptable variance (8 of 21 aberrations were attributed to glucose measurements). Bland-Altman analysis indicated that, with the exclusion of glucose measurements, BS from PVCs is reliable, with 29 (6.5%) of 448 pairs exceeding the limits of agreement. Of those, 9 cases were clinically significant, but none would have altered clinical management.<\/jats:p><\/jats:sec><jats:sec><jats:title>CONCLUSIONS:<\/jats:title><jats:p>PVC sampling was shown to be a pain-reducing method that can be used for children for selected basic analytes. The findings for glucose were unreliable.<\/jats:p><\/jats:sec>","DOI":"10.1542\/peds.2009-2920","type":"journal-article","created":{"date-parts":[[2010,6,22]],"date-time":"2010-06-22T00:54:36Z","timestamp":1277168076000},"page":"e179-e186","source":"Crossref","is-referenced-by-count":23,"title":["Blood Sampling Through Peripheral Venous Catheters Is Reliable for Selected Basic Analytes in Children"],"prefix":"10.1542","volume":"126","author":[{"given":"Sivan","family":"Berger-Achituv","sequence":"first","affiliation":[{"name":"Departments of Pediatrics and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Britta","family":"Budde-Schwartzman","sequence":"additional","affiliation":[{"name":"Pediatric Surgery and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin H.","family":"Ellis","sequence":"additional","affiliation":[{"name":"Blood Bank, Meir Medical Center, Kfar Saba, Israel;"},{"name":"Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ze'ev","family":"Shenkman","sequence":"additional","affiliation":[{"name":"Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; and"},{"name":"Department of Anesthesia, Sheba Medical Center, Tel Hashomer, Ramat Gan, Israel"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ilan","family":"Erez","sequence":"additional","affiliation":[{"name":"Pediatric Surgery and"},{"name":"Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; and"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"417","published-online":{"date-parts":[[2010,7,1]]},"reference":[{"issue":"1","key":"2021120819592419600_B1","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/0304-3959(90)91050-S","article-title":"A prospective survey of reactions to blood tests by children and adolescents","volume":"40","author":"Fradet","year":"1990","journal-title":"Pain"},{"issue":"1","key":"2021120819592419600_B2","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1542\/peds.90.1.87","article-title":"The occurrence of high levels of acute behavioral distress in children and adolescents undergoing routine venipunctures","volume":"90","author":"Humphrey","year":"1992","journal-title":"Pediatrics"},{"key":"2021120819592419600_B3","doi-asserted-by":"crossref","first-page":"S130","DOI":"10.1542\/peds.2008-1055e","article-title":"Clinical implications of unmanaged needle-insertion pain and distress in children","volume":"122","author":"Kennedy","year":"2008","journal-title":"Pediatrics"},{"issue":"6","key":"2021120819592419600_B4","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1001\/archpedi.161.6.578","article-title":"Caregivers' responses to pain in their children in the emergency department","volume":"161","author":"Smith","year":"2007","journal-title":"Arch Pediatr Adolesc Med"},{"issue":"1","key":"2021120819592419600_B5","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1093\/ajcp\/79.1.119","article-title":"Data regarding blood drawing sites in patients receiving intravenous fluids","volume":"79","author":"Watson","year":"1983","journal-title":"Am J Clin Pathol"},{"issue":"7","key":"2021120819592419600_B6","doi-asserted-by":"crossref","first-page":"789","DOI":"10.1016\/S0196-0644(05)81705-6","article-title":"Intravenous catheter aspiration for obtaining basic analytes during intravenous infusion","volume":"19","author":"Herr","year":"1990","journal-title":"Ann Emerg Med"},{"issue":"4","key":"2021120819592419600_B7","first-page":"209","article-title":"The reliability of blood sampling from peripheral intravenous infusion lines: complete blood cell counts, electrolyte panels, and survey panels","volume":"21","author":"Mohler","year":"1998","journal-title":"J Intraven Nurs"},{"issue":"5","key":"2021120819592419600_B8","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1067\/mem.2001.118015","article-title":"Comparison of laboratory values obtained by means of routine venipuncture versus peripheral intravenous catheter after a normal saline solution bolus","volume":"38","author":"Zlotowski","year":"2001","journal-title":"Ann Emerg Med"},{"issue":"1","key":"2021120819592419600_B9","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1067\/mhl.2001.110535","article-title":"Accuracy of drawing blood through infusing intravenous lines","volume":"30","author":"Himberger","year":"2001","journal-title":"Heart Lung"},{"issue":"3","key":"2021120819592419600_B10","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/S0099-1767(97)90012-X","article-title":"A comparative study of hematocrits drawn from a standard venipuncture and those drawn from a saline lock device","volume":"23","author":"Sliwa","year":"1997","journal-title":"J Emerg Nurs"},{"issue":"5","key":"2021120819592419600_B11","first-page":"290","article-title":"Blood sample collection from a peripheral catheter system compared with phlebotomy","volume":"23","author":"Seemann","year":"2000","journal-title":"J Intraven Nurs"},{"issue":"6","key":"2021120819592419600_B12","doi-asserted-by":"crossref","first-page":"439","DOI":"10.4037\/ajcc1998.7.6.439","article-title":"Accuracy of measurements of hemoglobin and potassium in blood samples from peripheral catheters","volume":"7","author":"Fincher","year":"1998","journal-title":"Am J Crit Care"},{"issue":"1","key":"2021120819592419600_B13","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1197\/j.aem.2006.06.053","article-title":"Comparison of laboratory values obtained by phlebotomy versus saline lock devices","volume":"14","author":"Corbo","year":"2007","journal-title":"Acad Emerg Med"},{"key":"2021120819592419600_B14","unstructured":"Centers for Disease Control and Prevention. Code of Federal Regulations (10\/2004) Part 493: laboratory requirements. Available at: wwwn.cdc.gov\/clia\/chronol.aspx. Accessed May 1, 2010"},{"issue":"8476","key":"2021120819592419600_B15","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"issue":"6","key":"2021120819592419600_B16","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/S0099-1767(96)80213-3","article-title":"A comparison of hemolysis rates using intravenous catheters versus venipuncture tubes for obtaining blood samples","volume":"22","author":"Kennedy","year":"1996","journal-title":"J Emerg Nurs"},{"issue":"4","key":"2021120819592419600_B17","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1016\/j.jen.2005.05.004","article-title":"Factors affecting hemolysis rates in blood samples drawn from newly placed IV sites in the emergency department","volume":"31","author":"Dugan","year":"2005","journal-title":"J Emerg Nurs"},{"issue":"6","key":"2021120819592419600_B18","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1093\/ajcp\/90.6.702","article-title":"Effect of drawing blood specimens proximal to an in-place but discontinued intravenous solution: can blood be drawn above the site of a shut-off i.v.?","volume":"90","author":"Read","year":"1988","journal-title":"Am J Clin Pathol"},{"issue":"3","key":"2021120819592419600_B19","first-page":"141","article-title":"The minimum discard volume: accurate analysis of peripheral hematocrit","volume":"19","author":"Yucha","year":"1996","journal-title":"J Intraven Nurs"}],"container-title":["Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/publications.aap.org\/pediatrics\/article-pdf\/126\/1\/e179\/1050808\/zpe0071000e179.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/publications.aap.org\/pediatrics\/article-pdf\/126\/1\/e179\/1050808\/zpe0071000e179.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,1]],"date-time":"2023-06-01T17:47:52Z","timestamp":1685641672000},"score":1,"resource":{"primary":{"URL":"https:\/\/publications.aap.org\/pediatrics\/article\/126\/1\/e179\/68305\/Blood-Sampling-Through-Peripheral-Venous-Catheters"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,7,1]]},"references-count":19,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2010,7,1]]},"published-print":{"date-parts":[[2010,7,1]]}},"URL":"https:\/\/doi.org\/10.1542\/peds.2009-2920","relation":{},"ISSN":["0031-4005","1098-4275"],"issn-type":[{"type":"print","value":"0031-4005"},{"type":"electronic","value":"1098-4275"}],"subject":[],"published":{"date-parts":[[2010,7,1]]}}}