{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T10:59:38Z","timestamp":1780570778425,"version":"3.54.1"},"reference-count":99,"publisher":"American Academy of Pediatrics (AAP)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2011,9,1]]},"abstract":"<jats:p>Circulatory shock is an important cause of pediatric morbidity and mortality and requires early recognition and prompt institution of adequate treatment protocols. Unfortunately, the hemodynamic status of the critically ill child is poorly reflected by physical examination, heart rate, blood pressure, or laboratory blood tests. Advanced hemodynamic monitoring consists, among others, of measuring cardiac output, predicting fluid responsiveness, calculating systemic oxygen delivery in relation to oxygen demand, and quantifying (pulmonary) edema. We discuss here the potential value of these hemodynamic monitoring technologies in relation to pediatric physiology.<\/jats:p>","DOI":"10.1542\/peds.2010-2920","type":"journal-article","created":{"date-parts":[[2011,8,9]],"date-time":"2011-08-09T02:23:49Z","timestamp":1312856629000},"page":"560-571","source":"Crossref","is-referenced-by-count":40,"title":["Advanced Hemodynamic Monitoring in Critically Ill Children"],"prefix":"10.1542","volume":"128","author":[{"given":"Joris","family":"Lemson","sequence":"first","affiliation":[{"name":"Department of Intensive Care Medicine, Radboud University Nijmegen Medical Centre, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anneliese","family":"Nusmeier","sequence":"additional","affiliation":[{"name":"Department of Intensive Care Medicine, Radboud University Nijmegen Medical Centre, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johannes G.","family":"van der Hoeven","sequence":"additional","affiliation":[{"name":"Department of Intensive Care Medicine, Radboud University Nijmegen Medical Centre, The Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"417","published-online":{"date-parts":[[2011,9,1]]},"reference":[{"issue":"2","key":"2021120823444409300_B1","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1542\/peds.2008-1967","article-title":"Mortality and functional morbidity after use of PALS\/APLS by community physicians","volume":"124","author":"Carcillo","year":"2009","journal-title":"Pediatrics"},{"key":"2021120823444409300_B2","doi-asserted-by":"crossref","DOI":"10.1002\/9780470757369","volume-title":"Advanced Paediatric Life Support: The Practical Approach","author":"Advanced Support Life Group","year":"2005","edition":"4th ed"},{"issue":"4","key":"2021120823444409300_B3","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1542\/peds.2007-1979","article-title":"Distinct hemodynamic patterns of septic shock at presentation to pediatric intensive care","volume":"122","author":"Brierley","year":"2008","journal-title":"Pediatrics"},{"issue":"2","key":"2021120823444409300_B4","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1136\/adc.80.2.163","article-title":"Capillary refill and core-peripheral temperature gap as indicators of haemodynamic status in paediatric intensive care patients","volume":"80","author":"Tibby","year":"1999","journal-title":"Arch Dis Child"},{"issue":"6","key":"2021120823444409300_B5","doi-asserted-by":"crossref","first-page":"516","DOI":"10.1136\/adc.77.6.516","article-title":"Clinicians' abilities to estimate cardiac index in ventilated children and infants","volume":"77","author":"Tibby","year":"1997","journal-title":"Arch Dis Child"},{"issue":"5","key":"2021120823444409300_B6","doi-asserted-by":"crossref","first-page":"592","DOI":"10.1053\/jcan.2002.126954","article-title":"Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmonary indicator dilution in critically ill neonates and infants","volume":"16","author":"Schiffmann","year":"2002","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"6","key":"2021120823444409300_B7","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1093\/bja\/aer090","article-title":"Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography","volume":"106","author":"Pereira de Souza Neto","year":"2011","journal-title":"Br J Anaesth"},{"issue":"19","key":"2021120823444409300_B8","doi-asserted-by":"crossref","first-page":"1368","DOI":"10.1056\/NEJMoa010307","article-title":"Early goal-directed therapy in the treatment of severe sepsis and septic shock","volume":"345","author":"Rivers","year":"2001","journal-title":"N Engl J Med"},{"issue":"2","key":"2021120823444409300_B9","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1097\/CCM.0b013e31819323c6","article-title":"Clinical practice parameters for hemodynamic support of pediatric and neonatal septic shock: 2007 update from the American College of Critical Care Medicine","volume":"37","author":"Brierley","year":"2009","journal-title":"Crit Care Med"},{"issue":"9","key":"2021120823444409300_B10","doi-asserted-by":"crossref","first-page":"1242","DOI":"10.1001\/jama.1991.03470090076035","article-title":"Role of early fluid resuscitation in pediatric septic shock","volume":"266","author":"Carcillo","year":"1991","journal-title":"JAMA"},{"issue":"8","key":"2021120823444409300_B11","doi-asserted-by":"crossref","first-page":"1771","DOI":"10.1097\/01.CCM.0000132897.52737.49","article-title":"Fluid overload before continuous hemofiltration and survival in critically ill children: a retrospective analysis","volume":"32","author":"Foland","year":"2004","journal-title":"Crit Care Med"},{"issue":"2","key":"2021120823444409300_B12","first-page":"87","article-title":"Thoracic duct lymph flow: a comparative study in newborn and adult sheep","volume":"8","author":"Harake","year":"1986","journal-title":"J Dev Physiol"},{"issue":"5","key":"2021120823444409300_B13","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1097\/01.ccx.0000176699.51456.13","article-title":"Myocardial dysfunction in meningococcal septic shock","volume":"11","author":"Makwana","year":"2005","journal-title":"Curr Opin Crit Care"},{"issue":"3","key":"2021120823444409300_B14","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1097\/01.PCC.0000262802.81164.03","article-title":"Energy expenditure in critically ill children","volume":"8","author":"Framson","year":"2007","journal-title":"Pediatr Crit Care Med"},{"issue":"3","key":"2021120823444409300_B15","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1111\/j.1748-1716.1982.tb06993.x","article-title":"Effect of age on cardiac index, stroke index and left ventricular ejection fraction at rest and during exercise as studied by radiocardiography","volume":"114","author":"Kuikka","year":"1982","journal-title":"Acta Physiol Scand"},{"issue":"5","key":"2021120823444409300_B16","doi-asserted-by":"crossref","first-page":"1042","DOI":"10.1161\/01.CIR.73.5.1042","article-title":"Left ventricular performance and contractility before and after volume infusion: a comparative study of preterm and full-term newborn lambs","volume":"73","author":"Baylen","year":"1986","journal-title":"Circulation"},{"key":"2021120823444409300_B17","volume-title":"Pediatric Cardiac Anesthesia","author":"Lake","year":"1998","edition":"3rd ed"},{"issue":"6","key":"2021120823444409300_B18","doi-asserted-by":"crossref","first-page":"606","DOI":"10.1097\/PCC.0b013e31818d1971","article-title":"Predicting major adverse events after cardiac surgery in children","volume":"9","author":"Seear","year":"2008","journal-title":"Pediatr Crit Care Med"},{"issue":"12","key":"2021120823444409300_B19","doi-asserted-by":"crossref","first-page":"1170","DOI":"10.1111\/j.1460-9592.2008.02770.x","article-title":"Effect of elevated PEEP on dynamic variables of fluid responsiveness in a pediatric animal model","volume":"18","author":"Renner","year":"2008","journal-title":"Paediatr Anaesth"},{"issue":"1","key":"2021120823444409300_B20","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1111\/j.1442-200X.2008.02654.x","article-title":"Cardiac output and blood volume parameters using femoral arterial thermodilution","volume":"51","author":"L\u00f3pez-Herce","year":"2009","journal-title":"Pediatr Int"},{"issue":"12","key":"2021120823444409300_B21","doi-asserted-by":"crossref","first-page":"818","DOI":"10.1016\/S0002-9149(99)80419-6","article-title":"Noninvasive assessment of myocardial contractility, preload, and afterload in healthy newborn infants","volume":"75","author":"Rowland","year":"1995","journal-title":"Am J Cardiol"},{"issue":"1","key":"2021120823444409300_B22","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1111\/j.1399-6576.2004.00270.x","article-title":"Fluid challenge in patients at risk for fluid loading-induced pulmonary edema","volume":"48","author":"Matejovic","year":"2004","journal-title":"Acta Anaesthesiol Scand"},{"issue":"2","key":"2021120823444409300_B23","doi-asserted-by":"crossref","DOI":"10.1542\/peds.102.2.e19","article-title":"Hemodynamic support in fluid-refractory pediatric septic shock","volume":"102","author":"Ceneviva","year":"1998","journal-title":"Pediatrics"},{"issue":"3","key":"2021120823444409300_B24","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1097\/PCC.0b013e318172ea56","article-title":"Transpulmonary thermodilution: finally, a gold standard for pediatric cardiac output measurement","volume":"9","author":"Tibby","year":"2008","journal-title":"Pediatr Crit Care Med"},{"key":"2021120823444409300_B25","article-title":"Hemodynamic monitoring by transpulmonary thermodilution and pulse contour analysis in critically ill children","author":"Proulx","year":"2011","journal-title":"Pediatr Crit Care Med"},{"issue":"3","key":"2021120823444409300_B26","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1097\/PCC.0b013e31816c6fa1","article-title":"Validation of transpulmonary thermodilution cardiac output measurement in a pediatric animal model","volume":"9","author":"Lemson","year":"2008","journal-title":"Pediatr Crit Care Med"},{"issue":"3","key":"2021120823444409300_B27","doi-asserted-by":"crossref","first-page":"R105","DOI":"10.1186\/cc9054","article-title":"Extravascular lung water index measurement in critically ill children does not correlate with a chest x-ray score of pulmonary edema [published correction appears in Crit Care. 2010;14(4):430]","volume":"14","author":"Lemson","year":"2010","journal-title":"Crit Care"},{"issue":"4","key":"2021120823444409300_B28","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1586\/erd.10.19","article-title":"Cardiac output monitoring in pediatric patients","volume":"7","author":"Nusmeier","year":"2010","journal-title":"Expert Rev Med Devices"},{"issue":"2","key":"2021120823444409300_B29","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1159\/000237223","article-title":"Cardiac output measurement in ventilated lambs with a significant left-to-right shunt using the modified carbon dioxide Fick method","volume":"97","author":"de Boode","year":"2009","journal-title":"Neonatology"},{"key":"2021120823444409300_B30","doi-asserted-by":"crossref","DOI":"10.1093\/bja\/aer127","article-title":"Cardiac output can be measured with the transpulmonary thermodilution method in a pediatric animal model with a left-to-right shunt","author":"Nusmeier","year":"2011","journal-title":"Br J Anesth"},{"issue":"13","key":"2021120823444409300_B31","doi-asserted-by":"crossref","first-page":"1664","DOI":"10.1001\/jama.294.13.1664","article-title":"Impact of the pulmonary artery catheter in critically ill patients: meta-analysis of randomized clinical trials","volume":"294","author":"Shah","year":"2005","journal-title":"JAMA"},{"issue":"1","key":"2021120823444409300_B32","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1111\/j.1365-2044.2007.05233.x","article-title":"Systematic review of the literature for the use of oesophageal Doppler monitor for fluid replacement in major abdominal surgery","volume":"63","author":"Abbas","year":"2008","journal-title":"Anaesthesia"},{"issue":"1","key":"2021120823444409300_B33","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1136\/adc.88.1.46","article-title":"Monitoring cardiac function in intensive care","volume":"88","author":"Tibby","year":"2003","journal-title":"Arch Dis Child"},{"issue":"1","key":"2021120823444409300_B34","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1111\/j.1399-6576.2009.02086.x","article-title":"Central venous oxygen saturation for the diagnosis of low cardiac output in septic shock patients","volume":"54","author":"Perner","year":"2010","journal-title":"Acta Anaesthesiol Scand"},{"issue":"5","key":"2021120823444409300_B35","doi-asserted-by":"crossref","first-page":"1099","DOI":"10.1016\/j.jtcvs.2005.10.057","article-title":"Inclusion of oxygen consumption improves the accuracy of arterial and venous oxygen saturation interpretation after the Norwood procedure","volume":"131","author":"Li","year":"2006","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"1","key":"2021120823444409300_B36","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1097\/01.PCC.0000102383.07075.97","article-title":"Low inferior vena caval catheters for hemodynamic and pulmonary function monitoring in pediatric critical care patients","volume":"5","author":"Fernandez","year":"2004","journal-title":"Pediatr Crit Care Med"},{"issue":"3","key":"2021120823444409300_B37","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/S0210-5691(08)70923-9","article-title":"Significance of venous oximetry in the critically ill","volume":"32","author":"Bauer","year":"2008","journal-title":"Med Intensiva"},{"issue":"4","key":"2021120823444409300_B38","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1111\/j.1365-2044.2008.05793.x","article-title":"Comparison of central venous oxygen saturation and mixed venous oxygen saturation during liver transplantation","volume":"64","author":"el-Masry","year":"2009","journal-title":"Anaesthesia"},{"issue":"1","key":"2021120823444409300_B39","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1097\/PCC.0b013e318193699d","article-title":"Adequate agreement between venous oxygen saturation in right atrium and pulmonary artery in critically ill children","volume":"10","author":"P\u00e9rez","year":"2009","journal-title":"Pediatr Crit Care Med"},{"issue":"3","key":"2021120823444409300_B40","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1097\/01.ccx.0000224872.09077.dc","article-title":"Venous oximetry","volume":"12","author":"Marx","year":"2006","journal-title":"Curr Opin Crit Care"},{"issue":"1","key":"2021120823444409300_B41","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1097\/PCC.0b013e3181a63e0c","article-title":"Evaluation of a pediatric central venous oximetry catheter in critically ill children","volume":"11","author":"Spenceley","year":"2010","journal-title":"Pediatr Crit Care Med"},{"issue":"8","key":"2021120823444409300_B42","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1097\/EJA.0b013e32833bf5c5","article-title":"The PediaSat continuous central Svo2 monitoring system does not reliably indicate state or course of central venous oxygenation","volume":"27","author":"Baulig","year":"2010","journal-title":"Eur J Anaesthesiol"},{"issue":"6","key":"2021120823444409300_B43","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1007\/s00134-008-1085-9","article-title":"ACCM\/PALS haemodynamic support guidelines for paediatric septic shock: an outcomes comparison with and without monitoring central venous oxygen saturation","volume":"34","author":"de Oliveira","year":"2008","journal-title":"Intensive Care Med"},{"issue":"2","key":"2021120823444409300_B44","doi-asserted-by":"crossref","first-page":"R33","DOI":"10.1186\/cc6811","article-title":"The incidence of low venous oxygen saturation on admission to the intensive care unit: a multi-center observational study in the Netherlands","volume":"12","author":"van Beest","year":"2008","journal-title":"Crit Care"},{"issue":"16","key":"2021120823444409300_B45","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1056\/NEJM199510193331601","article-title":"A trial of goal-oriented hemodynamic therapy in critically ill patients. Svo2 Collaborative Group","volume":"333","author":"Gattinoni","year":"1995","journal-title":"N Engl J Med"},{"issue":"1","key":"2021120823444409300_B46","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1007\/s00134-010-1980-8","article-title":"Low and \u201csupranormal\u201d central venous oxygen saturation and markers of tissue hypoxia in cardiac surgery patients: a prospective observational study","volume":"37","author":"Perz","year":"2011","journal-title":"Intensive Care Med"},{"issue":"8","key":"2021120823444409300_B47","doi-asserted-by":"crossref","first-page":"2369","DOI":"10.1097\/CCM.0b013e3181a0f919","article-title":"Association between blood lactate levels, sequential organ failure assessment subscores, and 28-day mortality during early and late intensive care unit stay: a retrospective observational study","volume":"37","author":"Jansen","year":"2009","journal-title":"Crit Care Med"},{"issue":"6","key":"2021120823444409300_B48","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1164\/rccm.200912-1918OC","article-title":"Early lactate-guided therapy in ICU patients: a multicenter, open-label, randomized, controlled trial","volume":"182","author":"Jansen","year":"2010","journal-title":"Am J Respir Crit Care Med"},{"issue":"4","key":"2021120823444409300_B49","doi-asserted-by":"crossref","first-page":"1094","DOI":"10.1016\/j.jtcvs.2005.06.029","article-title":"Systemic venous oxygen saturation after the Norwood procedure and childhood neurodevelopmental outcome","volume":"130","author":"Hoffman","year":"2005","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2021120823444409300_B50","doi-asserted-by":"crossref","first-page":"I82","DOI":"10.1161\/01.cir.0000032878.55215.bd","article-title":"Improved survival of patients undergoing palliation of hypoplastic left heart syndrome: lessons learned from 115 consecutive patients","volume":"106","author":"Tweddell","year":"2002","journal-title":"Circulation"},{"issue":"9","key":"2021120823444409300_B51","doi-asserted-by":"crossref","first-page":"2642","DOI":"10.1097\/CCM.0b013e3181a590da","article-title":"Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature","volume":"37","author":"Marik","year":"2009","journal-title":"Crit Care Med"},{"issue":"8","key":"2021120823444409300_B52","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1007\/s00246-010-9776-8","article-title":"Respiratory variation in aortic blood flow velocity as a predictor of fluid responsiveness in children after repair of ventricular septal defect","volume":"31","author":"Choi","year":"2010","journal-title":"Pediatr Cardiol"},{"issue":"5","key":"2021120823444409300_B53","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1007\/s00134-008-1021-z","article-title":"Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children","volume":"34","author":"Durand","year":"2008","journal-title":"Intensive Care Med"},{"issue":"3","key":"2021120823444409300_B54","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1097\/MCC.0b013e3283378185","article-title":"Bedside assessment of mean systemic filling pressure","volume":"16","author":"Jansen","year":"2010","journal-title":"Curr Opin Crit Care"},{"issue":"1","key":"2021120823444409300_B55","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1378\/chest.07-2331","article-title":"Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares","volume":"134","author":"Marik","year":"2008","journal-title":"Chest"},{"issue":"1","key":"2021120823444409300_B56","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s10877-006-9051-y","article-title":"Variation in blood pressure as a guide to volume loading in children following cardiopulmonary bypass","volume":"21","author":"Tran","year":"2007","journal-title":"J Clin Monit Comput"},{"key":"2021120823444409300_B57","doi-asserted-by":"crossref","DOI":"10.1016\/j.jcrc.2010.10.014","article-title":"Extravascular lung water index and global end-diastolic volume index should be corrected in children","author":"Lemson","year":"2011","journal-title":"J Crit Care"},{"issue":"5","key":"2021120823444409300_B58","doi-asserted-by":"crossref","first-page":"1900","DOI":"10.1378\/chest.124.5.1900","article-title":"Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock","volume":"124","author":"Michard","year":"2003","journal-title":"Chest"},{"issue":"5","key":"2021120823444409300_B59","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1053\/j.jvca.2007.05.006","article-title":"Global end-diastolic volume as a variable of fluid responsiveness during acute changing loading conditions","volume":"21","author":"Renner","year":"2007","journal-title":"J Cardiothorac Vasc Anesth"},{"issue":"1","key":"2021120823444409300_B60","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1007\/s00134-006-0404-2","article-title":"Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients","volume":"33","author":"Goepfert","year":"2007","journal-title":"Intensive Care Med"},{"key":"2021120823444409300_B61","article-title":"Hemodynamic monitoring by transpulmonary thermodilution and pulse contour analysis in critically ill children","author":"Proulx","year":"2011","journal-title":"Pediatr Crit Care Med"},{"issue":"2","key":"2021120823444409300_B62","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1097\/PCC.0b013e3181937227","article-title":"Extravascular lung water measurement using transpulmonary thermodilution in children","volume":"10","author":"Lemson","year":"2009","journal-title":"Pediatr Crit Care Med"},{"issue":"5","key":"2021120823444409300_B63","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1097\/ALN.0b013e31819db2a1","article-title":"Influence of respiratory rate on stroke volume variation in mechanically ventilated patients","volume":"110","author":"De Backer","year":"2009","journal-title":"Anesthesiology"},{"issue":"2","key":"2021120823444409300_B64","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1093\/bja\/aem361","article-title":"Delta down compared with delta pulse pressure as an indicator of volaemia during intracranial surgery","volume":"100","author":"Deflandre","year":"2008","journal-title":"Br J Anaesth"},{"issue":"1","key":"2021120823444409300_B65","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1164\/ajrccm.162.1.9903035","article-title":"Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure","volume":"162","author":"Michard","year":"2000","journal-title":"Am J Respir Crit Care Med"},{"issue":"3","key":"2021120823444409300_B66","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1097\/CCM.0b013e3181968fe1","article-title":"Predicting volume responsiveness by using the end-expiratory occlusion in mechanically ventilated intensive care unit patients","volume":"37","author":"Monnet","year":"2009","journal-title":"Crit Care Med"},{"issue":"7","key":"2021120823444409300_B67","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1007\/s00134-007-0644-9","article-title":"Can dynamic indicators help the prediction of fluid responsiveness in spontaneously breathing critically ill patients?","volume":"33","author":"Soubrier","year":"2007","journal-title":"Intensive Care Med"},{"issue":"2","key":"2021120823444409300_B68","doi-asserted-by":"crossref","first-page":"510","DOI":"10.1097\/CCM.0b013e3181958bf7","article-title":"Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions","volume":"37","author":"de Waal","year":"2009","journal-title":"Crit Care Med"},{"issue":"10","key":"2021120823444409300_B69","doi-asserted-by":"crossref","first-page":"2858","DOI":"10.1097\/CCM.0b013e3181865aea","article-title":"Effect of tidal volume, sampling duration, and cardiac contractility on pulse pressure and stroke volume variation during positive-pressure ventilation","volume":"36","author":"Kim","year":"2008","journal-title":"Crit Care Med"},{"issue":"6","key":"2021120823444409300_B70","doi-asserted-by":"crossref","first-page":"2000","DOI":"10.1378\/chest.121.6.2000","article-title":"Predicting fluid responsiveness in ICU patients","volume":"121","author":"Michard","year":"2002","journal-title":"Chest"},{"issue":"3","key":"2021120823444409300_B71","doi-asserted-by":"crossref","first-page":"374","DOI":"10.1111\/j.1399-6576.2007.01544.x","article-title":"Pulse pressure variation and stroke volume variation during different loading conditions in a paediatric animal model","volume":"52","author":"Renner","year":"2008","journal-title":"Acta Anaesthesiol Scand"},{"issue":"4","key":"2021120823444409300_B72","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1007\/s00134-008-0994-y","article-title":"Passive leg raising","volume":"34","author":"Monnet","year":"2008","journal-title":"Intensive Care Med"},{"key":"2021120823444409300_B73","first-page":"66","article-title":"Development of lung edema: interstitial fluid dynamics and molecular structure","volume":"16","author":"Miserocchi","year":"2001","journal-title":"News Physiol Sci"},{"issue":"4","key":"2021120823444409300_B74","doi-asserted-by":"crossref","first-page":"1301","DOI":"10.1152\/jappl.1999.87.4.1301","article-title":"Alveolar epithelial fluid transport and the resolution of clinically severe hydrostatic pulmonary edema","volume":"87","author":"Verghese","year":"1999","journal-title":"J Appl Physiol"},{"issue":"2","key":"2021120823444409300_B75","first-page":"395","article-title":"Morphologic and physiologic correlates of increased extravascular lung water","volume":"96","author":"Bongard","year":"1984","journal-title":"Surgery"},{"issue":"1","key":"2021120823444409300_B76","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1097\/SLA.0b013e3181ad61c8","article-title":"Preliminary results of a prospective randomized trial of restrictive versus standard fluid regime in elective open abdominal aortic aneurysm repair","volume":"250","author":"McArdle","year":"2009","journal-title":"Ann Surg"},{"issue":"4","key":"2021120823444409300_B77","doi-asserted-by":"crossref","first-page":"L547","DOI":"10.1152\/ajplung.00127.2009","article-title":"Measurement of extravascular lung water using the single indicator method in patients: research and potential clinical value","volume":"297","author":"Brown","year":"2009","journal-title":"Am J Physiol Lung Cell Mol Physiol"},{"issue":"4","key":"2021120823444409300_B78","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1097\/01.CCM.0000259539.49339.66","article-title":"Bedside assessment of extravascular lung water by dilution methods: temptations and pitfalls","volume":"35","author":"Michard","year":"2007","journal-title":"Crit Care Med"},{"issue":"1","key":"2021120823444409300_B79","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1097\/MCC.0b013e328011459b","article-title":"How important is the measurement of extravascular lung water?","volume":"13","author":"Fern\u00e1ndez-Mond\u00e9jar","year":"2007","journal-title":"Curr Opin Crit Care"},{"issue":"1","key":"2021120823444409300_B80","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1007\/s00134-010-2006-2","article-title":"Hemodynamic, respiratory, and perfusion parameters during asphyxia, resuscitation, and post-resuscitation in a pediatric model of cardiac arrest","volume":"37","author":"L\u00f3pez-Herce","year":"2011","journal-title":"Intensive Care Med"},{"issue":"7","key":"2021120823444409300_B81","doi-asserted-by":"crossref","first-page":"1550","DOI":"10.1097\/01.CCM.0000130995.18334.8B","article-title":"Accuracy of transpulmonary thermodilution versus gravimetric measurement of extravascular lung water","volume":"32","author":"Katzenelson","year":"2004","journal-title":"Crit Care Med"},{"issue":"6","key":"2021120823444409300_B82","doi-asserted-by":"crossref","first-page":"R451","DOI":"10.1186\/cc2974","article-title":"Extravascular lung water assessed by transpulmonary single thermodilution and postmortem gravimetry in sheep","volume":"8","author":"Kirov","year":"2004","journal-title":"Crit Care"},{"issue":"4","key":"2021120823444409300_B83","doi-asserted-by":"crossref","first-page":"R107","DOI":"10.1186\/cc7948","article-title":"Comparison of three methods of extra-vascular lung water volume measurement in patients following cardiac surgery","volume":"13","author":"Maddison","year":"2009","journal-title":"Crit Care"},{"issue":"5","key":"2021120823444409300_B84","doi-asserted-by":"crossref","first-page":"R162","DOI":"10.1186\/cc9250","article-title":"Validation of extravascular lung water measurement by single transpulmonary thermodilution: human autopsy study","volume":"14","author":"Tagami","year":"2010","journal-title":"Crit Care"},{"issue":"8","key":"2021120823444409300_B85","doi-asserted-by":"crossref","first-page":"2001","DOI":"10.1097\/01.CCM.0000277248.70144.5F","article-title":"Limitations of extravascular lung water assessment by dilution methods in children","volume":"35","author":"Cid","year":"2007","journal-title":"Crit Care Med"},{"issue":"9","key":"2021120823444409300_B86","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1136\/adc.2004.067538","article-title":"Prediction of total body water in infants and children","volume":"90","author":"Wells","year":"2005","journal-title":"Arch Dis Child"},{"issue":"1","key":"2021120823444409300_B87","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1097\/01.CCM.0000295314.01232.BE","article-title":"Extravascular lung water in sepsis-associated acute respiratory distress syndrome: indexing with predicted body weight improves correlation with severity of illness and survival","volume":"36","author":"Phillips","year":"2008","journal-title":"Crit Care Med"},{"issue":"7","key":"2021120823444409300_B88","doi-asserted-by":"crossref","first-page":"956","DOI":"10.1016\/j.rmed.2008.02.016","article-title":"Impact of extravascular lung water index on outcomes of severe sepsis patients in a medical intensive care unit","volume":"102","author":"Chung","year":"2008","journal-title":"Respir Med"},{"issue":"1","key":"2021120823444409300_B89","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1007\/s00134-010-2047-6","article-title":"Prognostic value of extravascular lung water index in critically ill children with acute respiratory failure","volume":"37","author":"Lubrano","year":"2011","journal-title":"Intensive Care Med"},{"issue":"3","key":"2021120823444409300_B90","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1007\/s00134-006-0498-6","article-title":"Assessing pulmonary permeability by transpulmonary thermodilution allows differentiation of hydrostatic pulmonary edema from ALI\/ARDS","volume":"33","author":"Monnet","year":"2007","journal-title":"Intensive Care Med"},{"issue":"5","key":"2021120823444409300_B91","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1164\/ajrccm\/145.5.990","article-title":"Improved outcome based on fluid management in critically ill patients requiring pulmonary artery catheterization","volume":"145","author":"Mitchell","year":"1992","journal-title":"Am Rev Respir Dis"},{"issue":"24","key":"2021120823444409300_B92","doi-asserted-by":"crossref","first-page":"2564","DOI":"10.1056\/NEJMoa062200","article-title":"Comparison of two fluid-management strategies in acute lung injury","volume":"354","author":"Wiedemann","year":"2006","journal-title":"N Engl J Med"},{"issue":"3","key":"2021120823444409300_B93","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1164\/rccm.200508-1302OC","article-title":"The beta-agonist lung injury trial (BALTI): a randomized placebo-controlled clinical trial","volume":"173","author":"Perkins","year":"2006","journal-title":"Am J Respir Crit Care Med"},{"issue":"2","key":"2021120823444409300_B94","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1097\/01.PCC.0000257039.32593.DC","article-title":"Analysis of the evidence for the lower limit of systolic and mean arterial pressure in children","volume":"8","author":"Haque","year":"2007","journal-title":"Pediatr Crit Care Med"},{"issue":"11","key":"2021120823444409300_B95","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.1136\/adc.2004.068718","article-title":"Age related reference ranges for respiration rate and heart rate from 4 to 16 years","volume":"90","author":"Wallis","year":"2005","journal-title":"Arch Dis Child"},{"issue":"12","key":"2021120823444409300_B96","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1097\/PEC.0b013e31818e9f3a","article-title":"Time- and fluid-sensitive resuscitation for hemodynamic support of children in septic shock: barriers to the implementation of the American College of Critical Care Medicine\/Pediatric Advanced Life Support guidelines in a pediatric intensive care unit in a developing world","volume":"24","author":"Oliveira","year":"2008","journal-title":"Pediatr Emerg Care"},{"issue":"5","key":"2021120823444409300_B97","doi-asserted-by":"crossref","first-page":"1119","DOI":"10.1097\/01.CCM.0000163238.64905.56","article-title":"Let us use the pulmonary artery catheter correctly and only when we need it","volume":"33","author":"Pinsky","year":"2005","journal-title":"Crit Care Med"},{"issue":"5","key":"2021120823444409300_B98","doi-asserted-by":"crossref","first-page":"1490","DOI":"10.1016\/j.athoracsur.2009.01.071","article-title":"Postoperative cerebral oxygenation in hypoplastic left heart syndrome after the Norwood procedure","volume":"87","author":"Phelps","year":"2009","journal-title":"Ann Thorac Surg"},{"issue":"1","key":"2021120823444409300_B99","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1097\/CCM.0b013e3181fb7994","article-title":"Persistent low microcirculatory vessel density in non-survivors of sepsis in pediatric intensive care","volume":"39","author":"Top","year":"2011","journal-title":"Crit Care Med"}],"container-title":["Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/publications.aap.org\/pediatrics\/article-pdf\/128\/3\/560\/845369\/zpe00911000560.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/publications.aap.org\/pediatrics\/article-pdf\/128\/3\/560\/845369\/zpe00911000560.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,9]],"date-time":"2024-04-09T19:56:32Z","timestamp":1712692592000},"score":1,"resource":{"primary":{"URL":"https:\/\/publications.aap.org\/pediatrics\/article\/128\/3\/560\/30694\/Advanced-Hemodynamic-Monitoring-in-Critically-Ill"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,9,1]]},"references-count":99,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2011,9,1]]},"published-print":{"date-parts":[[2011,9,1]]}},"URL":"https:\/\/doi.org\/10.1542\/peds.2010-2920","relation":{},"ISSN":["0031-4005","1098-4275"],"issn-type":[{"value":"0031-4005","type":"print"},{"value":"1098-4275","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,9,1]]}}}