{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T16:17:30Z","timestamp":1793636250926,"version":"4.5.1"},"reference-count":77,"publisher":"American Academy of Pediatrics (AAP)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,12,1]]},"abstract":"<jats:sec><jats:title>CONTEXT<\/jats:title><jats:p>Transcutaneous bilirubinometry (TcB) is used as a valid screening to identify neonates requiring measurement of total serum bilirubin (TSB) before phototherapy. Its use during and after phototherapy is not advised yet because of unknown reliability.<\/jats:p><\/jats:sec><jats:sec><jats:title>OBJECTIVES<\/jats:title><jats:p>To determine the agreement of TcB and TSB measurements before, during, and after phototherapy.<\/jats:p><\/jats:sec><jats:sec><jats:title>DATA SOURCES<\/jats:title><jats:p>PubMed Medline, Cochrane Library, and references of eligible studies were searched.<\/jats:p><\/jats:sec><jats:sec><jats:title>STUDY SELECTION<\/jats:title><jats:p>Prospective and retrospective cohort and cross-sectional studies reporting Bland-Altman statistics of paired TcB and TSB measurements in term and preterm newborns.<\/jats:p><\/jats:sec><jats:sec><jats:title>DATA EXTRACTION<\/jats:title><jats:p>Meta-analysis was performed using the Mantel-Haenszel weighted approach. The agreement between TcB and TSB in \u03bcmol\/L was described by pooled mean differences (MDs) and limits of agreement (LoA).<\/jats:p><\/jats:sec><jats:sec><jats:title>RESULTS<\/jats:title><jats:p>Fifty-four studies were included. The pooled MD before phototherapy is 2.5 \u03bcmol\/L (LoA \u221238.3 to 43.3). The pooled MD during phototherapy is \u22120.3 \u03bcmol\/L (LoA \u221234.8 to 34.2) on covered skin and \u221228.6 \u03bcmol\/L (LoA \u2212105.7 to 48.5) on uncovered skin. The pooled MD after phototherapy is \u221234.3 \u03bcmol\/L (LoA \u221286.7 to 18.1) on covered skin and \u221221.1 \u03bcmol\/L (LoA \u221288.6 to 46.4) on uncovered skin. Subgroup analysis revealed the best agreement at the forehead. We did not find any difference in agreement between term and preterm neonates.<\/jats:p><\/jats:sec><jats:sec><jats:title>LIMITATIONS<\/jats:title><jats:p>Language restriction.<\/jats:p><\/jats:sec><jats:sec><jats:title>CONCLUSIONS<\/jats:title><jats:p>TcB measurements before and during phototherapy on covered skin show good agreement compared with TSB in term and preterm newborns. More studies are needed to evaluate the accuracy after phototherapy.<\/jats:p><\/jats:sec>","DOI":"10.1542\/peds.2023-062335","type":"journal-article","created":{"date-parts":[[2023,11,22]],"date-time":"2023-11-22T08:12:36Z","timestamp":1700640756000},"source":"Crossref","is-referenced-by-count":24,"title":["Transcutaneous Bilirubin Accuracy Before, During, and After Phototherapy: A Meta-Analysis"],"prefix":"10.1542","volume":"152","author":[{"given":"Lisa","family":"ten Kate","sequence":"first","affiliation":[{"name":"aMedical Mission Suriname, Brownsweg, Suriname"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tiemen","family":"van Oorschot","sequence":"additional","affiliation":[{"name":"bDepartment of Elderly Care Medicine, Silverein, Bilthoven, Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jessica","family":"Woolderink","sequence":"additional","affiliation":[{"name":"cDepartment of Pediatrics, Universitair Medisch Centrum Groningen, Groningen, Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sarah","family":"Teklenburg-Roord","sequence":"additional","affiliation":[{"name":"dDepartment of Pediatrics, Isala Zwolle, Zwolle, Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jolita","family":"Bekhof","sequence":"additional","affiliation":[{"name":"dDepartment of Pediatrics, Isala Zwolle, Zwolle, Netherlands"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"417","published-online":{"date-parts":[[2023,11,22]]},"reference":[{"issue":"4","key":"2023120103000830000_B1","doi-asserted-by":"crossref","first-page":"207","DOI":"10.1136\/archdischild-2016-311556","article-title":"Jaundice in newborn babies under 28\u2005days: NICE guideline 2016 (CG98)","volume":"102","author":"Amos","year":"2017","journal-title":"Arch Dis Child Educ Pract Ed"},{"issue":"6","key":"2023120103000830000_B2","doi-asserted-by":"crossref","first-page":"782","DOI":"10.1016\/j.jpeds.2007.11.003","article-title":"Is visual assessment of jaundice reliable as a screening tool to detect significant neonatal hyperbilirubinemia?","volume":"152","author":"Riskin","year":"2008","journal-title":"J Pediatr"},{"issue":"1","key":"2023120103000830000_B3","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1542\/peds.2011-0599","article-title":"Impact of a transcutaneous bilirubinometry program on resource utilization and severe hyperbilirubinemia","volume":"129","author":"Wainer","year":"2012","journal-title":"Pediatrics"},{"issue":"3","key":"2023120103000830000_B4","doi-asserted-by":"crossref","first-page":"E285","DOI":"10.9778\/cmajo.20170158","article-title":"Cost savings with transcutaneous screening versus total serum bilirubin measurement for newborn jaundice in hospital and community settings: a cost-minimization analysis","volume":"6","author":"McClean","year":"2018","journal-title":"CMAJ Open"},{"issue":"6","key":"2023120103000830000_B5","doi-asserted-by":"crossref","first-page":"e20162414","DOI":"10.1542\/peds.2016-2414","article-title":"Transcutaneous bilirubinometry in jaundiced neonates: a randomized controlled trial","volume":"138","author":"van den Esker-Jonker","year":"2016","journal-title":"Pediatrics"},{"issue":"7","key":"2023120103000830000_B6","doi-asserted-by":"crossref","first-page":"1280","DOI":"10.1373\/clinchem.2008.121889","article-title":"Hyperbilirubinemia and transcutaneous bilirubinometry","volume":"55","author":"el-Beshbishi","year":"2009","journal-title":"Clin Chem"},{"issue":"3","key":"2023120103000830000_B7","doi-asserted-by":"crossref","first-page":"e2022058859","DOI":"10.1542\/peds.2022-058859","article-title":"Clinical practice guideline revision: management of hyperbilirubinemia in the newborn infant 35 or more weeks of gestation","volume":"150","author":"Kemper","year":"2022","journal-title":"Pediatrics"},{"issue":"5","key":"2023120103000830000_B8","doi-asserted-by":"crossref","first-page":"734","DOI":"10.1080\/14767058.2017.1390561","article-title":"Accuracy of transcutaneous bilirubinometry in the preterm infants: a comprehensive meta-analysis","volume":"32","author":"Hassan Shabuj","year":"2019","journal-title":"J Matern Fetal Neonatal Med"},{"issue":"5","key":"2023120103000830000_B9","doi-asserted-by":"crossref","first-page":"871","DOI":"10.1542\/peds.2013-1713","article-title":"Reliability of transcutaneous bilirubin devices in preterm infants: a systematic review","volume":"132","author":"Nagar","year":"2013","journal-title":"Pediatrics"},{"issue":"6","key":"2023120103000830000_B10","doi-asserted-by":"crossref","first-page":"E118","DOI":"10.1097\/ANC.0000000000000738","article-title":"Accuracy of transcutaneous bilirubin versus serum bilirubin measurement in preterm infants receiving phototherapy: a systematic review","volume":"20","author":"Hynes","year":"2020","journal-title":"Adv Neonatal Care"},{"issue":"3","key":"2023120103000830000_B11","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1159\/000442195","article-title":"Effect of phototherapy on the reliability of transcutaneous bilirubin devices in term and near-term infants: a systematic review and meta-analysis","volume":"109","author":"Nagar","year":"2016","journal-title":"Neonatology"},{"issue":"8476","key":"2023120103000830000_B12","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"key":"2023120103000830000_B13","author":"Moher"},{"issue":"15","key":"2023120103000830000_B14","doi-asserted-by":"crossref","first-page":"2008","DOI":"10.1001\/jama.283.15.2008","article-title":"Meta-analysis of observational studies in epidemiology\u2013a proposal for reporting","volume":"283","author":"Stroup","year":"2000","journal-title":"JAMA"},{"issue":"8","key":"2023120103000830000_B15","doi-asserted-by":"crossref","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","article-title":"QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies","volume":"155","author":"Whiting","year":"2011","journal-title":"Ann Intern Med"},{"issue":"7","key":"2023120103000830000_B16","doi-asserted-by":"crossref","first-page":"1096","DOI":"10.1093\/clinchem\/48.7.1096","article-title":"Direct spectrophotometric method for measurement of bilirubin in newborns: comparison with HPLC and an automated diazo method","volume":"48","author":"Kazmierczak","year":"2002","journal-title":"Clin Chem"},{"issue":"14","key":"2023120103000830000_B17","doi-asserted-by":"crossref","first-page":"2013","DOI":"10.1002\/sim.1158","article-title":"Meta-analysis of method comparison studies","volume":"21","author":"Williamson","year":"2002","journal-title":"Stat Med"},{"issue":"3","key":"2023120103000830000_B18","doi-asserted-by":"crossref","first-page":"e009509","DOI":"10.1136\/bmjopen-2015-009509","article-title":"Temperature measurements with a temporal scanner: systematic review and meta-analysis","volume":"6","author":"Geijer","year":"2016","journal-title":"BMJ Open"},{"issue":"1","key":"2023120103000830000_B19","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1186\/s12245-017-0156-5","article-title":"The accuracy of emergency weight estimation systems in children-a systematic review and meta-analysis","volume":"10","author":"Wells","year":"2017","journal-title":"Int J Emerg Med"},{"issue":"1","key":"2023120103000830000_B20","doi-asserted-by":"crossref","first-page":"43","DOI":"10.21315\/mjms2022.29.1.5","article-title":"Comparison between the transcutaneous and total serum bilirubin measurement in Malay neonates with neonatal jaundice","volume":"29","author":"Mohamed","year":"2022","journal-title":"Malays J Med Sci"},{"issue":"2","key":"2023120103000830000_B21","first-page":"262","article-title":"Evaluation of the relationship between transcutaneous bilirubin measurement and total serum bilirubin in neonatal patients followed for jaundice","volume":"55","author":"Cat","year":"2021","journal-title":"Sisli Etfal Hastan Tip Bul"},{"issue":"3","key":"2023120103000830000_B22","doi-asserted-by":"crossref","first-page":"E30","DOI":"10.1097\/JPN.0000000000000555","article-title":"Comparing JM-105 and MBJ-20 transcutaneous bilirubinometers according to the area tested in ethnically diverse late-preterm and term neonates","volume":"35","author":"Khajehei","year":"2021","journal-title":"J Perinat Neonatal Nurs"},{"issue":"4","key":"2023120103000830000_B23","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1159\/000516648","article-title":"Transcutaneous versus total serum bilirubin measurements in preterm infants","volume":"118","author":"Jegathesan","year":"2021","journal-title":"Neonatology"},{"issue":"1","key":"2023120103000830000_B24","first-page":"15","article-title":"Accuracy of enhanced transcutaneous bilirubinometry according to various measurement sites","volume":"56","author":"Casnocha Lucanova","year":"2021","journal-title":"Turk Pediatri Ars"},{"issue":"2","key":"2023120103000830000_B25","first-page":"116","article-title":"Accuracy of transcutaneous bilirubin measurement in full-term newborns at 3400 meters above sea level","volume":"78","author":"Mendoza-Chuctaya","year":"2021","journal-title":"Bol M\u00e9d Hosp Infant M\u00e9xico"},{"issue":"7","key":"2023120103000830000_B26","doi-asserted-by":"crossref","first-page":"2072","DOI":"10.1111\/apa.15777","article-title":"Comparison of the correlation of various site transcutaneous bilirubin measurements with serum bilirubin levels at the end of phototherapy","volume":"110","author":"Alptekin","year":"2021","journal-title":"Acta Paediatr"},{"issue":"1","key":"2023120103000830000_B27","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1186\/s12887-020-02450-w","article-title":"The forehead is a better site than the sternum to check transcutaneous bilirubin during phototherapy in sick infants","volume":"20","author":"Jeon","year":"2020","journal-title":"BMC Pediatr"},{"issue":"2","key":"2023120103000830000_B28","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1038\/jp.2016.189","article-title":"Reliability of transcutaneous bilirubinometry from shielded skin in neonates receiving phototherapy: a prospective cohort study","volume":"37","author":"Murli","year":"2017","journal-title":"J Perinatol"},{"issue":"2","key":"2023120103000830000_B29","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1007\/s00431-013-2142-0","article-title":"Accuracy of transcutaneous bilirubin measurement in preterm low birth weight neonates","volume":"173","author":"Chawla","year":"2014","journal-title":"Eur J Pediatr"},{"issue":"2","key":"2023120103000830000_B30","first-page":"172","article-title":"Accuracy of transcutaneous bilirubin measurement in term newborns","volume":"96","author":"Kosarat","year":"2013","journal-title":"J Med Assoc Thai"},{"issue":"9","key":"2023120103000830000_B31","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1016\/j.clinbiochem.2012.03.014","article-title":"Transcutaneous bilirubin measurement: comparison of Respironics BiliCheck and JM-103 in a normal newborn population","volume":"45","author":"Romagnoli","year":"2012","journal-title":"Clin Biochem"},{"issue":"1","key":"2023120103000830000_B32","first-page":"67","article-title":"Transcutaneous measurement of bilirubin in Turkish newborns: comparison with total serum bilirubin","volume":"53","author":"Kaynak-T\u00fcrkmen","year":"2011","journal-title":"Turk J Pediatr"},{"issue":"6","key":"2023120103000830000_B33","first-page":"1533","article-title":"Comparison of two transcutaneous bilirubinometers\u2013 Minolta Airshields Jaundice meter JM103 and Spectrx Bilicheck\u2013in Thai neonates","volume":"36","author":"Sanpavat","year":"2005","journal-title":"Southeast Asian J Trop Med Public Health"},{"issue":"6","key":"2023120103000830000_B34","doi-asserted-by":"crossref","first-page":"1628","DOI":"10.1542\/peds.113.6.1628","article-title":"Evaluation of a new transcutaneous bilirubinometer","volume":"113","author":"Maisels","year":"2004","journal-title":"Pediatrics"},{"issue":"6","key":"2023120103000830000_B35","doi-asserted-by":"crossref","first-page":"e0218131","DOI":"10.1371\/journal.pone.0218131","article-title":"Should transcutaneous bilirubin be measured in preterm infants receiving phototherapy? The relationship between transcutaneous and total serum bilirubin in preterm infants with and without phototherapy","volume":"14","author":"Hulzebos","year":"2019","journal-title":"PLoS One"},{"issue":"1","key":"2023120103000830000_B36","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1080\/14767058.2018.1484098","article-title":"Accuracy of the Bilicare transcutaneous bilirubinometer as the predischarge screening tool for significant hyperbilirubinemia in healthy term and late preterm neonates","volume":"33","author":"Chokemungmeepisarn","year":"2020","journal-title":"J Matern Fetal Neonatal Med"},{"issue":"4","key":"2023120103000830000_B37","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1159\/000452788","article-title":"Use of transcutaneous bilirubin to determine the need for phototherapy in resource-limited settings","volume":"111","author":"Olusanya","year":"2017","journal-title":"Neonatology"},{"issue":"1","key":"2023120103000830000_B38","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1186\/s12887-018-1290-9","article-title":"Agreement test of transcutaneous bilirubin and bilistick with serum bilirubin in preterm infants receiving phototherapy","volume":"18","author":"Rohsiswatmo","year":"2018","journal-title":"BMC Pediatr"},{"key":"2023120103000830000_B39","doi-asserted-by":"crossref","first-page":"105029","DOI":"10.1016\/j.earlhumdev.2020.105029","article-title":"Prediction of the need for phototherapy during hospital stay in preterm infants by transcutaneous bilirubinometry","volume":"146","author":"Raba","year":"2020","journal-title":"Early Hum Dev"},{"issue":"22","key":"2023120103000830000_B40","doi-asserted-by":"crossref","first-page":"4318","DOI":"10.1080\/14767058.2020.1849112","article-title":"The accuracy of transcutaneous bilirubin to identify hyperbilirubinemia in jaundiced neonates","volume":"35","author":"Ying","year":"2022","journal-title":"J Matern Fetal Neonatal Med"},{"issue":"11","key":"2023120103000830000_B41","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1002\/kjm2.12121","article-title":"Comparison of transcutaneous and serum bilirubin before, under, and after phototherapy in term and late-preterm infants","volume":"35","author":"Yang","year":"2019","journal-title":"Kaohsiung J Med Sci"},{"issue":"5","key":"2023120103000830000_B42","doi-asserted-by":"crossref","first-page":"2018","DOI":"10.1542\/peds.2018-2039","article-title":"A novel icterometer for hyperbilirubinemia screening in low-resource settings","volume":"143","author":"Lee","year":"2019","journal-title":"Pediatrics"},{"issue":"12","key":"2023120103000830000_B43","doi-asserted-by":"crossref","first-page":"1144","DOI":"10.1177\/0009922811417292","article-title":"Accuracy of neonatal transcutaneous bilirubin measurement in the outpatient setting","volume":"50","author":"Wickremasinghe","year":"2011","journal-title":"Clin Pediatr (Phila)"},{"issue":"2","key":"2023120103000830000_B44","doi-asserted-by":"crossref","first-page":"e2021053928","DOI":"10.1542\/peds.2021-053928","article-title":"Evaluation of a point-of-care test for bilirubin in Malawi","volume":"150","author":"Shapiro","year":"2022","journal-title":"Pediatrics"},{"issue":"2","key":"2023120103000830000_B45","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1179\/2046905513Y.0000000050","article-title":"Can transcutaneous bilirubinometry safely guide phototherapy treatment of neonatal jaundice in Malawi?","volume":"34","author":"Rylance","year":"2014","journal-title":"Paediatr Int Child Health"},{"key":"2023120103000830000_B46","doi-asserted-by":"crossref","first-page":"105418","DOI":"10.1016\/j.earlhumdev.2021.105418","article-title":"Cephalocaudal progression of neonatal jaundice assessed by transcutaneous bilirubin measurements","volume":"160","author":"Kamphuis","year":"2021","journal-title":"Early Hum Dev"},{"issue":"6","key":"2023120103000830000_B47","doi-asserted-by":"crossref","first-page":"fmab101","DOI":"10.1093\/tropej\/fmab101","article-title":"Neonatal eye shielding during phototherapy: what protects the eye better?","volume":"67","author":"Abdulkadir","year":"2021","journal-title":"J Trop Pediatr"},{"issue":"3","key":"2023120103000830000_B48","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1111\/j.1651-2227.2003.tb00554.x","article-title":"Transcutaneous bilirubinometry during and after phototherapy","volume":"92","author":"Tan","year":"2003","journal-title":"Acta Paediatr"},{"issue":"6","key":"2023120103000830000_B49","doi-asserted-by":"crossref","first-page":"F480","DOI":"10.1136\/archdischild-2013-305699","article-title":"Influence of skin color on diagnostic accuracy of the jaundice meter JM 103 in newborns","volume":"99","author":"Samiee-Zafarghandy","year":"2014","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"issue":"1","key":"2023120103000830000_B50","doi-asserted-by":"crossref","first-page":"e000681","DOI":"10.1136\/bmjpo-2020-000681","article-title":"Transcutaneous bilirubinometry during and after phototherapy in preterm infants: a prospective observational study","volume":"4","author":"Raba","year":"2020","journal-title":"BMJ Paediatr Open"},{"issue":"9","key":"2023120103000830000_B51","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.3390\/diagnostics11091729","article-title":"The impact of phototherapy on the accuracy of transcutaneous bilirubin measurements in neonates: optimal measurement site and timing","volume":"11","author":"Ho","year":"2021","journal-title":"Diagnostics (Basel)"},{"issue":"8","key":"2023120103000830000_B52","doi-asserted-by":"crossref","first-page":"2629","DOI":"10.1007\/s00431-021-04148-2","article-title":"Efficacy of transcutaneous bilirubinometry as compared to serum bilirubin in preterm newborn during phototherapy","volume":"180","author":"Gothwal","year":"2021","journal-title":"Eur J Pediatr"},{"issue":"2","key":"2023120103000830000_B53","doi-asserted-by":"crossref","first-page":"607","DOI":"10.1007\/s00431-020-03885-0","article-title":"Reliability of transcutaneous bilirubin determination based on skin color determined by a neonatal skin color scale of our own","volume":"180","author":"Maya-Enero","year":"2021","journal-title":"Eur J Pediatr"},{"issue":"2","key":"2023120103000830000_B54","doi-asserted-by":"crossref","first-page":"226","DOI":"10.1038\/s41372-019-0557-9","article-title":"Accuracy of transcutaneous bilirubin on covered skin in preterm and term newborns receiving phototherapy using a JM-105 bilirubinometer","volume":"40","author":"Costa-Posada","year":"2020","journal-title":"J Perinatol"},{"issue":"5","key":"2023120103000830000_B55","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1515\/jpm-2018-0429","article-title":"Usefulness of transcutaneous bilirubin assessment measured in non-photo-exposed skin to guide the length of phototherapy: an observational study","volume":"47","author":"Castro","year":"2019","journal-title":"J Perinat Med"},{"key":"2023120103000830000_B56","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.clinbiochem.2018.03.018","article-title":"The accuracy of transcutaneous bilirubinometer measurements to identify the hyperbilirubinemia in outpatient newborn population","volume":"55","author":"Ercan","year":"2018","journal-title":"Clin Biochem"},{"issue":"3","key":"2023120103000830000_B57","doi-asserted-by":"crossref","first-page":"e20160907","DOI":"10.1542\/peds.2016-0907","article-title":"Differences between transcutaneous and serum bilirubin measurements in Black African neonates","volume":"138","author":"Olusanya","year":"2016","journal-title":"Pediatrics"},{"issue":"12","key":"2023120103000830000_B58","doi-asserted-by":"crossref","first-page":"1902","DOI":"10.1111\/j.1651-2227.2009.01385.x","article-title":"Bhutani-based nomograms for the prediction of significant hyperbilirubinemia using transcutaneous measurements of bilirubin","volume":"98","author":"Bental","year":"2009","journal-title":"Acta Paediatr"},{"issue":"8","key":"2023120103000830000_B59","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1038\/jp.2009.38","article-title":"Evaluation of transcutaneous bilirubinometry in preterm neonates","volume":"29","author":"Schmidt","year":"2009","journal-title":"J Perinatol"},{"issue":"2","key":"2023120103000830000_B60","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1093\/pch\/11.2.79","article-title":"Estimation of bilirubin using BiliChek, a transcutaneous bilirubin measurement device: effects of gestational age and use of phototherapy","volume":"11","author":"Jangaard","year":"2006","journal-title":"Paediatr Child Health"},{"issue":"9","key":"2023120103000830000_B61","first-page":"1803","article-title":"Transcutaneous bilirubin in the preterm infants","volume":"90","author":"Sanpavat","year":"2007","journal-title":"J Med Assoc Thai"},{"issue":"10","key":"2023120103000830000_B62","first-page":"1193","article-title":"Noninvasive transcutaneous bilirubin as a screening test to identify the need for serum bilirubin assessment","volume":"87","author":"Sanpavat","year":"2004","journal-title":"J Med Assoc Thai"},{"issue":"2","key":"2023120103000830000_B63","doi-asserted-by":"crossref","first-page":"E17","DOI":"10.1542\/peds.106.2.e17","article-title":"Noninvasive measurement of total serum bilirubin in a multiracial predischarge newborn population to assess the risk of severe hyperbilirubinemia","volume":"106","author":"Bhutani","year":"2000","journal-title":"Pediatrics"},{"issue":"10","key":"2023120103000830000_B64","first-page":"e18442","article-title":"A comparison between transcutaneous bilirubin and total serum bilirubin levels for the management of jaundice in preterm neonates by Bland-Altman Plot","volume":"13","author":"Panda","year":"2021","journal-title":"Cureus"},{"key":"2023120103000830000_B65","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s40748-017-0070-0","article-title":"Evaluation of transcutaneous bilirubinometer (DRAEGER JM 103) use in Zimbabwean newborn babies","volume":"4","author":"Chimhini","year":"2018","journal-title":"Matern Health Neonatol Perinatol"},{"key":"2023120103000830000_B66","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1016\/j.jpeds.2017.05.080","article-title":"Patched skin bilirubin assay to monitor neonates born extremely preterm undergoing phototherapy","volume":"188","author":"De Luca","year":"2017","journal-title":"J Pediatr"},{"issue":"6","key":"2023120103000830000_B67","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1111\/ped.13248","article-title":"Transcutaneous bilirubin measurement during phototherapy in term neonates","volume":"59","author":"Katayama","year":"2017","journal-title":"Pediatr Int (Roma)"},{"issue":"5","key":"2023120103000830000_B68","first-page":"323","article-title":"Transcutaneous bilirubinometry in preterm and term newborn infants before and during phototherapy","volume":"19","author":"Radfar","year":"2016","journal-title":"Arch Iran Med"},{"issue":"2","key":"2023120103000830000_B69","doi-asserted-by":"crossref","first-page":"142","DOI":"10.15537\/smj.2016.2.13419","article-title":"Transcutaneous bilirubin measurement in healthy Saudi term newborns","volume":"37","author":"Alsaedi","year":"2016","journal-title":"Saudi Med J"},{"issue":"3","key":"2023120103000830000_B70","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1093\/pch\/16.3.141","article-title":"Transcutaneous bilirubin measurement at the time of hospital discharge in a multiethnic newborn population","volume":"16","author":"Campbell","year":"2011","journal-title":"Paediatr Child Health"},{"issue":"2","key":"2023120103000830000_B71","doi-asserted-by":"crossref","first-page":"267","DOI":"10.3109\/14767058.2010.484471","article-title":"Transcutaneous bilirubin\u2013comparing the accuracy of BiliChek and JM 103 in a regional postnatal unit","volume":"24","author":"Qualter","year":"2011","journal-title":"J Matern Fetal Neonatal Med"},{"issue":"8","key":"2023120103000830000_B72","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1016\/j.earlhumdev.2009.05.010","article-title":"Skin bilirubin measurement during phototherapy in preterm and term newborn infants","volume":"85","author":"Zecca","year":"2009","journal-title":"Early Hum Dev"},{"issue":"3","key":"2023120103000830000_B73","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.clinbiochem.2008.09.108","article-title":"Clinical implication of the difference between transcutaneous bilirubinometry and total serum bilirubin for the classification of newborns at risk of hyperbilirubinemia","volume":"42","author":"Rodr\u00edguez-Capote","year":"2009","journal-title":"Clin Biochem"},{"issue":"5","key":"2023120103000830000_B74","first-page":"356","article-title":"Evaluation of a point-of-care transcutaneous bilirubinometer in Chinese neonates at an accident and emergency department","volume":"14","author":"Lam","year":"2008","journal-title":"Hong Kong Med J"},{"issue":"5","key":"2023120103000830000_B75","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.earlhumdev.2006.06.006","article-title":"Using BiliCheck for preterm neonates in a sub-intensive unit: diagnostic usefulness and suitability","volume":"83","author":"De Luca","year":"2007","journal-title":"Early Hum Dev"},{"issue":"6","key":"2023120103000830000_B76","doi-asserted-by":"crossref","first-page":"F434","DOI":"10.1136\/adc.2005.090217","article-title":"Evaluation of a new transcutaneous bilirubinometer in Chinese newborns","volume":"91","author":"Ho","year":"2006","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"issue":"6","key":"2023120103000830000_B77","doi-asserted-by":"crossref","first-page":"1636","DOI":"10.1542\/peds.113.6.1636","article-title":"Transcutaneous bilirubin measurements and serum total bilirubin levels in indigenous African infants","volume":"113","author":"Slusher","year":"2004","journal-title":"Pediatrics"}],"container-title":["Pediatrics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/publications.aap.org\/pediatrics\/article-pdf\/doi\/10.1542\/peds.2023-062335\/1578534\/peds.2023-062335.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/publications.aap.org\/pediatrics\/article-pdf\/doi\/10.1542\/peds.2023-062335\/1578534\/peds.2023-062335.pdf","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,11,2]],"date-time":"2024-11-02T16:47:37Z","timestamp":1730566057000},"score":1,"resource":{"primary":{"URL":"https:\/\/publications.aap.org\/pediatrics\/article\/152\/6\/e2023062335\/195647\/Transcutaneous-Bilirubin-Accuracy-Before-During"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,22]]},"references-count":77,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2023,11,22]]},"published-print":{"date-parts":[[2023,12,1]]}},"URL":"https:\/\/doi.org\/10.1542\/peds.2023-062335","relation":{},"ISSN":["0031-4005","1098-4275"],"issn-type":[{"value":"0031-4005","type":"print"},{"value":"1098-4275","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,22]]},"article-number":"e2023062335"}}