{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,2]],"date-time":"2025-11-02T17:00:50Z","timestamp":1762102850397,"version":"3.40.5"},"reference-count":35,"publisher":"Akademiai Kiado Zrt.","issue":"3","license":[{"start":{"date-parts":[[2024,9,12]],"date-time":"2024-09-12T00:00:00Z","timestamp":1726099200000},"content-version":"unspecified","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["akjournals.com"],"crossmark-restriction":true},"short-container-title":["AVet"],"published-print":{"date-parts":[[2024,9,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Potential arrhythmias recorded by cardiac monitors using the built-in human algorithm are as follows: total number of episodes, ventricular tachycardia, asystole, bradycardia, atrial tachycardia, atrial fibrillation and the percentage of time spent in atrial tachycardia or atrial fibrillation. Long-term use of an insertable cardiac monitor (loop recorder) has been reported in one horse earlier, but its accurate role as a diagnostic tool is still unclear. The aim of the present study was to investigate the long-term applicability of the Reveal XT cardiac monitor for recording cardiac arrhythmias in adult horses. The Reveal XT cardiac monitor was implanted in 12 horses under sedation in standing position. Median duration of data recording calculated for the population was 1,169 days. The number of false positive detections of asystole and bradycardia was extremely high in all horses. For atrial fibrillation, false positive detection occurred in five and false negative detection occurred in one horse. The present study showed that the long-term use of the Reveal XT cardiac monitor is feasible, well-tolerated and the devices work reliably, without complications. The human algorithm could not be used for automatic detection of arrhythmic episodes in the study population. The device could detect atrial fibrillation in horses, but the recorded AF burden was inaccurate and the stored ECGs had to be manually interpreted. Because the human analyser algorithm of this cardiac monitor fails to identify bradyarrhythmias in horses based on our results, this instrument is not capable for accurately determining the aetiology of episodic collapse in this species.<\/jats:p>","DOI":"10.1556\/004.2024.01075","type":"journal-article","created":{"date-parts":[[2024,8,22]],"date-time":"2024-08-22T13:17:15Z","timestamp":1724332635000},"page":"178-185","update-policy":"https:\/\/doi.org\/10.1556\/policypage.crossmark.crossref.2","source":"Crossref","is-referenced-by-count":1,"title":["Long-term use of an implantable loop recorder for ECG recording in horses"],"prefix":"10.1556","volume":"72","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0260-4356","authenticated-orcid":true,"given":"Szilvia","family":"Kov\u00e1cs","sequence":"first","affiliation":[{"name":"Department and Clinic of Equine Medicine, University of Veterinary Medicine Budapest, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G\u00e1bor","family":"Bod\u00f3","sequence":"additional","affiliation":[{"name":"Department and Clinic of Equine Medicine, University of Veterinary Medicine Budapest, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ferenc Zs.","family":"T\u00f3th","sequence":"additional","affiliation":[{"name":"Medtronic Hungary Ltd, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L\u00e1szl\u00f3","family":"N\u00e9der","sequence":"additional","affiliation":[{"name":"Medtronic Hungary Ltd, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zolt\u00e1n","family":"Bakos","sequence":"additional","affiliation":[{"name":"Department and Clinic of Equine Medicine, University of Veterinary Medicine Budapest, Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"425","reference":[{"issue":"1","key":"B1","series-title":"Heart Rhythm","first-page":"75","article-title":"Incidence of false-positive transmissions during remote rhythm monitoring with implantable loop recorders","volume":"17","author":"Afzal, M. R.","year":"2020","unstructured":"Afzal, M. R., Mease, J., Koppert, T., Okabe, T., Tyler, J., Houmsse, M., Augostini R. S., Weiss R. Hummel J. D., Kalbfleisch S. J. and Daoud, E. G. (2020): Incidence of false-positive transmissions during remote rhythm monitoring with implantable loop recorders. Heart Rhythm, 17(1), 75\u201380. https:\/\/doi.org\/10.1016\/j.hrthm.2019.07.015."},{"issue":"3","key":"B2","series-title":"Curr. Cardiol. Rev.","first-page":"257","article-title":"The role of ECG in the diagnosis of left ventricular hypertrophy","volume":"10","author":"Bacharova, L. M.","year":"2014","unstructured":"Bacharova, L. M., Schocken, D., H Estes, E. and Strauss, D. (2014): The role of ECG in the diagnosis of left ventricular hypertrophy. Curr. Cardiol. Rev. 10(3), 257\u2013261. https:\/\/doi.org\/10.2174\/1573403X10666140514103220."},{"key":"B3","series-title":"J. Arrhythmia.","first-page":"25","article-title":"Implantable loop recorder in clinical practice","volume":"35","author":"Bisignani, A.","year":"2019","unstructured":"Bisignani, A., De Bonis, S., Mancuso, L., Ceravolo, G. and Bisignani, G. (2019): Implantable loop recorder in clinical practice. J. Arrhythmia. 35, 25\u2013 32. https:\/\/doi.org\/10.1002\/joa3.12142."},{"key":"B4","series-title":"2019 42nd International Convention on Information and Communication Technology, Electronics and Microelectronics (MIPRO)","first-page":"279","article-title":"Wireless body sensor for electrocardiographic monitoring in equine medicine","author":"Brlo\u017enik, M.","year":"2019","unstructured":"Brlo\u017enik, M., Petri\u010d, A. D., Kos, V. K., Rashkovska, A. and Avbelj, V. (2019): Wireless body sensor for electrocardiographic monitoring in equine medicine. In 2019 42nd International Convention on Information and Communication Technology, Electronics and Microelectronics (MIPRO) (pp. 279\u2013283). IEEE."},{"issue":"2","key":"B5","series-title":"Equine Vet. J.","first-page":"397","article-title":"Detection of atrial fibrillation with implantable loop recorders in horses","volume":"53","author":"Buhl, R.","year":"2021a","unstructured":"Buhl, R., Hesselkilde, E. M., Carstensen, H., Fenner, M. F., Jespersen, T., Tfelt\u2010Hansen, J. and Michael Sattler, S. (2021a): Detection of atrial fibrillation with implantable loop recorders in horses. Equine Vet. J. 53(2), 397\u2013403. https:\/\/doi.org\/10.1111\/evj.13301."},{"issue":"5","key":"B6","series-title":"Equine Vet. J.","first-page":"955","article-title":"Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance","volume":"53","author":"Buhl, R.","year":"2021b","unstructured":"Buhl, R., Nissen, S. D., Winther, M. L., Poulsen, S. K., Hopster\u2010Iversen, C., Jespersen, T., Sanders, P., Carstensen, H. and Hesselkilde, E. M. (2021b): Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance. Equine Vet. J. 53(5), 955\u2013963. https:\/\/doi.org\/10.1111\/evj.13372."},{"issue":"2","key":"B7","series-title":"J. Vet. Intern. Med.","first-page":"728","article-title":"Three\u2010dimensional electro\u2010anatomical mapping and radiofrequency ablation as a novel treatment for atrioventricular accessory pathway in a horse: a case report","volume":"37","author":"Buschmann, E.","year":"2023","unstructured":"Buschmann, E., Van Steenkiste, G., Boussy, T., Vernemmen, I., Schauvliege, S., Decloedt, A. and van Loon, G. (2023): Three\u2010dimensional electro\u2010anatomical mapping and radiofrequency ablation as a novel treatment for atrioventricular accessory pathway in a horse: a case report. J. Vet. Intern. Med. 37(2), 728\u2013734. https:\/\/doi.org\/10.1111\/jvim.16668."},{"issue":"5","key":"B8","series-title":"J. Vet. Intern. Med.","first-page":"2101","article-title":"Stall\u2010side screening potential of a smartphone electrocardiogram recorded over both sides of the thorax in horses","volume":"34","author":"Corradini, I.","year":"2020","unstructured":"Corradini, I., Fern\u00e1ndez\u2010Ruiz, A., Barba, M. and Engel\u2010Manchado, J. (2020): Stall\u2010side screening potential of a smartphone electrocardiogram recorded over both sides of the thorax in horses. J. Vet. Intern. Med. 34(5), 2101\u20132108. https:\/\/doi.org\/10.1111\/jvim.15795."},{"issue":"47","key":"B9","series-title":"Pacing Clin. Electrophysiol.","first-page":"406","article-title":"False\u2010positive alarms in patients with implantable loop recorder followed by remote monitoring: a systematic review","volume":"2024","author":"Covino, S.","year":"2024","unstructured":"Covino, S. and Russo, V. (2024): False\u2010positive alarms in patients with implantable loop recorder followed by remote monitoring: a systematic review. Pacing Clin. Electrophysiol. 2024(47), 406\u2013416. https:\/\/doi.org\/10.1111\/pace.14941."},{"key":"B11","series-title":"Int. J. Cardiol.","first-page":"58","article-title":"Initial real world experience with a novel insertable (Reveal LinQ\u2122@ Medtronic) compared to the conventional (Reveal XT\u2122@ Medtronic) implantable loop recorder at a tertiary care center\u2014points to ponder!","volume":"191","author":"Gunda, S.","year":"2015","unstructured":"Gunda, S., Reddy, Y. M., Pillarisetti, J., Koripalli, S., Jeffery, C., Swope, J., Atkins, D., Bommana, S., Emert, M. P., Pimentel, R., Dendi, R., Berenbom, L. D., DiBiase, L., Natale, A. and Lakkireddy, D. (2015): Initial real world experience with a novel insertable (Reveal LinQ\u2122@ Medtronic) compared to the conventional (Reveal XT\u2122@ Medtronic) implantable loop recorder at a tertiary care center\u2014points to ponder!. Int. J. Cardiol. 191, 58\u201363. https:\/\/doi.org\/10.1016\/j.ijcard.2015.04.241."},{"issue":"1","key":"B12","series-title":"J. Vet. Intern. Med.","first-page":"521","article-title":"A novel approach for obtaining 12\u2010lead electrocardiograms in horses","volume":"35","author":"Hesselkilde, E. M.","year":"2021","unstructured":"Hesselkilde, E. M., Isaksen, J. L., Petersen, B. V., Carstensen, H., Jespersen, T., Pehrson, S., Kanters, J. K. and Buhl, R. (2021): A novel approach for obtaining 12\u2010lead electrocardiograms in horses. J. Vet. Intern. Med. 35(1), 521\u2013531. https:\/\/doi.org\/10.1111\/jvim.15980."},{"issue":"5","key":"B13","series-title":"Ann. Emerg. Med.","first-page":"461","article-title":"Accuracy and clinical effect of out-of-hospital electrocardiography in the diagnosis of acute cardiac ischemia: a meta-analysis","volume":"37","author":"Ioannidis, J. P.","year":"2001","unstructured":"Ioannidis, J. P., Salem, D., Chew, P. W. and Lau, J. (2001): Accuracy and clinical effect of out-of-hospital electrocardiography in the diagnosis of acute cardiac ischemia: a meta-analysis. Ann. Emerg. Med. 37(5), 461\u2013470. https:\/\/doi.org\/10.1067\/mem.2001.114904."},{"issue":"4","key":"B14","series-title":"CVIA","first-page":"301","article-title":"Using three-dimensional Lorenz scatter plots to detect patients with atrioventricular node double path caused by interpolated ventricular premature systoles: a case study","volume":"5","author":"Jingxiu, L.","year":"2021","unstructured":"Jingxiu, L., Fujun, Z., Xijin, W. and Ding, P. (2021): Using three-dimensional Lorenz scatter plots to detect patients with atrioventricular node double path caused by interpolated ventricular premature systoles: a case study. CVIA 5(4), 301\u2013306. https:\/\/doi.org\/10.15212\/CVIA.2021.0006."},{"issue":"7","key":"B15","series-title":"Equine Vet. Educ.","first-page":"340","article-title":"Long\u2010term monitoring with an implantable loop recorder detects multiple episodes of paroxysmal atrial fibrillation after electrical cardioversion in a warmblood horse","volume":"35","author":"Kjeldsen, S. T.","year":"2023","unstructured":"Kjeldsen, S. T., Jensen, M., S\u00f8rensen, C. T., Hopster\u2010Iversen, C. and Nissen, S. D. (2023): Long\u2010term monitoring with an implantable loop recorder detects multiple episodes of paroxysmal atrial fibrillation after electrical cardioversion in a warmblood horse. Equine Vet. Educ. 35(7), 340\u2013346. https:\/\/doi.org\/10.1111\/eve.13745."},{"key":"B16","series-title":"Hearts","first-page":"45","article-title":"Review of the wide range of indications and uses of implantable loop recorders: a review of the literature","volume":"3","author":"Kwok, C. S.","year":"2022","unstructured":"Kwok, C. S., Darlington, D., Mayer, J., Panchal, G., Walker, V., Zachariah, D., Phan, T., Mallen, C. D., Barker, D. and Patwala, A. A., (2022): Review of the wide range of indications and uses of implantable loop recorders: a review of the literature. Hearts 3, 45\u201353. https:\/\/doi.org\/10.3390\/hearts3020007."},{"key":"B17","series-title":"J. Vet. Cardiol.","first-page":"67","article-title":"Cardiovascular variables in eventing and endurance horses over a season","volume":"21","author":"Lorello, O.","year":"2019","unstructured":"Lorello, O., Ramseyer, A., Burger, D., Gerber, V. and de Solis, C. N. (2019): Cardiovascular variables in eventing and endurance horses over a season. J. Vet. Cardiol. 21, 67\u201378. https:\/\/doi.org\/10.1016\/j.jvc.2018.08.004."},{"issue":"11","key":"B18","series-title":"Equine Vet. Educ.","first-page":"576","article-title":"Episodic collapse in the horse","volume":"22","author":"Lyle, C. H.","year":"2010","unstructured":"Lyle, C. H. and Keen, J. A. (2010): Episodic collapse in the horse. Equine Vet. Educ. 22(11), 576\u2013586. https:\/\/doi.org\/10.1111\/j.2042-3292.2010.00136.x."},{"issue":"6","key":"B19","series-title":"J. Vet. Intern. Med.","first-page":"1498","article-title":"Retrospective evaluation of episodic collapse in the horse in a referred population: 25 cases (1995\u20132009)","volume":"24","author":"Lyle, C. H.","year":"2010","unstructured":"Lyle, C. H., Turley, G., Blissitt, K. J., Pirie, R. S., Mayhew, I. G., McGorum, B. C. and Keen, J. A. (2010): Retrospective evaluation of episodic collapse in the horse in a referred population: 25 cases (1995\u20132009). J. Vet. Intern. Med. 24(6), 1498\u20131502. https:\/\/doi.org\/10.1111\/j.1939-1676.2010.0610.x."},{"issue":"1","key":"B20","series-title":"J. Vet. Cardiol.","first-page":"25","article-title":"Retrospective analysis of an implantable loop recorder for evaluation of syncope, collapse, or intermittent weakness in 23 dogs (2004\u20132008)","volume":"12","author":"MacKie, B. A.","year":"2010","unstructured":"MacKie, B. A., Stepien, R. L. and Kellihan, H. B. (2010): Retrospective analysis of an implantable loop recorder for evaluation of syncope, collapse, or intermittent weakness in 23 dogs (2004\u20132008). J. Vet. Cardiol. 12(1), 25\u201333. https:\/\/doi.org\/10.1016\/j.jvc.2009.12.003."},{"year":"2011","series-title":"Cardiology of the Horse","key":"B21","unstructured":"Marr, C. and Bowen, M., eds. (2011): Cardiology of the Horse. Elsevier Health Sciences. https:\/\/www.sciencedirect.com\/book\/9780702028175\/cardiology-of-the-horse."},{"key":"B22","series-title":"Austr. Vet. J.","first-page":"114","article-title":"Application of an electrocardiography device (iECG) for heart rhythm analysis after exercise in Thoroughbred horses","volume":"100","author":"Nath, L. C.","year":"2022","unstructured":"Nath, L. C., Forbes, G., Elliott, A. D., Tomren, V., Ryan, A. and Franklin, S. H. (2022): Application of an electrocardiography device (iECG) for heart rhythm analysis after exercise in Thoroughbred horses. Austr. Vet. J. 100, 114\u2013120. https:\/\/doi.org\/10.1111\/avj.13137."},{"issue":"21","key":"B23","series-title":"Animals","first-page":"2915","article-title":"Cartilaginous intrusion of the atrioventricular node in a quarter horse with a high burden of second-degree AV block and collapse: a case report","volume":"12","author":"Nissen, S. D.","year":"2022","unstructured":"Nissen, S. D., Saljic, A., Kjeldsen, S. T., Jespersen, T., Hopster-Iversen, C. and Buhl, R. (2022): Cartilaginous intrusion of the atrioventricular node in a quarter horse with a high burden of second-degree AV block and collapse: a case report. Animals, 12(21), 2915."},{"issue":"11","key":"B24","series-title":"Circ. Arrhyth.Electrophysiol.","article-title":"Remote monitoring of implantable loop recorders: false-positive alert episode burden","volume":"14","author":"O\u2019Shea, C. J.","year":"2021","unstructured":"O\u2019Shea, C. J., Middeldorp, M. E., Hendriks, J. M., Brooks, A. G., Harper, C., Thomas, G., Emami, M., Thiyagarajah, A., Feigofsky, S., Gopinathannair, R., Varma, N., Campbell, K., Lau D. H. and Sanders, P. (2021): Remote monitoring of implantable loop recorders: false-positive alert episode burden. Circ. Arrhyth.Electrophysiol. 14(11), e009635. https:\/\/doi.org\/10.1161\/CIRCEP.121.009635."},{"issue":"7","key":"B25","series-title":"J.Cardiovasc.Dev. Dis.","first-page":"306","article-title":"ECG smart monitoring versus implantable loop recorders for atrial fibrillation detection after cryptogenic stroke\u2014an overview for decision making","volume":"10","author":"Pezawas, T.","year":"2023","unstructured":"Pezawas, T. (2023): ECG smart monitoring versus implantable loop recorders for atrial fibrillation detection after cryptogenic stroke\u2014an overview for decision making. J.Cardiovasc.Dev. Dis. 10(7) 306. https:\/\/doi.org\/10.3390\/jcdd10070306."},{"issue":"25","key":"B26","series-title":"J. Am. Coll. Cardiol.","first-page":"3105","article-title":"Recurrence of atrial fibrillation after catheter ablation or antiarrhythmic drug therapy in the CABANA trial","volume":"75","author":"Poole, J. E.","year":"2020","unstructured":"Poole, J. E., Bahnson, T. D., Monahan, K. H., Johnson, G., Rostami, H., Silverstein, A. P., Al-Khalidi, H. R., Rosenberg, Y., Mark, D. B., Lee, K. L. and Packer, D. L. (2020): Recurrence of atrial fibrillation after catheter ablation or antiarrhythmic drug therapy in the CABANA trial. J. Am. Coll. Cardiol. 75(25), 3105\u20133118. https:\/\/doi.org\/10.1016\/j.jacc.2020.04.065."},{"issue":"1","key":"B27","series-title":"J. Am. Vet. Med. Assoc.","first-page":"78","article-title":"Evaluation of the diagnostic value of an implantable loop recorder in dogs with unexplained syncope","volume":"236","author":"Santilli, R. A.","year":"2010","unstructured":"Santilli, R. A., Ferasin, L., Voghera, S. G. and Perego, M. (2010): Evaluation of the diagnostic value of an implantable loop recorder in dogs with unexplained syncope. J. Am. Vet. Med. Assoc. 236(1), 78\u201382. https:\/\/doi.org\/10.2460\/javma.236.1.78."},{"issue":"5","key":"B28","series-title":"Clin. Cardiol.","first-page":"594","article-title":"Recurrence rate of atrial fibrillation after the first clinical episode: a prospective evaluation using continuous cardiac rhythm monitoring","volume":"41","author":"Simantirakis, E. N.","year":"2018","unstructured":"Simantirakis, E. N., Papakonstantinou, P. E., Kanoupakis, E., Chlouverakis, G. I., Tzeis, S. and Vardas, P. E. (2018): Recurrence rate of atrial fibrillation after the first clinical episode: a prospective evaluation using continuous cardiac rhythm monitoring. Clin. Cardiol. 41(5), 594\u2013600. https:\/\/doi.org\/10.1002\/clc.22904."},{"issue":"2","key":"B29","series-title":"Equine Vet. J.","first-page":"336","article-title":"Validation of an equine fitness tracker: ECG quality and arrhythmia detection","volume":"55","author":"Ter Woort, F.","year":"2023","unstructured":"Ter Woort, F., Dubois, G., Tansley, G., Didier, M., Verdegaal, E. L., Franklin, S. and Van Erck\u2010Westergren, E. (2023): Validation of an equine fitness tracker: ECG quality and arrhythmia detection. Equine Vet. J. 55(2), 336\u2013343. https:\/\/doi.org\/10.1111\/evj.13565."},{"key":"B30","series-title":"Equine Vet. J.","first-page":"208","article-title":"Observer agreement for detection of cardiac arrhythmias on telemetric ECG recordings obtained at rest, during and after exercise in 10 Warmblood horses","volume":"42","author":"Trachsel, D. S.","year":"2010","unstructured":"Trachsel, D. S., Bitschnau, C., Waldern, N., Weishaupt, M. A. and Schwarzwald, C. C. (2010): Observer agreement for detection of cardiac arrhythmias on telemetric ECG recordings obtained at rest, during and after exercise in 10 Warmblood horses. Equine Vet. J. 42, 208\u2013215."},{"key":"B31","series-title":"Vet. J.","article-title":"Catheter-based electrical interventions to study, diagnose and treat arrhythmias in horses: from refractory period to electro-anatomical mapping","volume":"263","author":"van Loon, G.","year":"2020","unstructured":"van Loon, G., Van Steenkiste, G., Vera, L. and Decloedt, A. (2020): Catheter-based electrical interventions to study, diagnose and treat arrhythmias in horses: from refractory period to electro-anatomical mapping. Vet. J. 263, 105519. https:\/\/doi.org\/10.1016\/j.tvjl.2020.105519."},{"key":"B32","series-title":"11th European College of Equine Internal Medicine Congress (ECEIM 2018)","article-title":"Specific 12-lead ECG characteristics that help localize the anatomical origin of ventricular ectopy in horses: preliminary data","author":"Van Steenkiste, G.","year":"2018","unstructured":"Van Steenkiste, G., De Clercq, D., Decloedt, A., Vera, L. and van Loon, G. (2018): Specific 12-lead ECG characteristics that help localize the anatomical origin of ventricular ectopy in horses: preliminary data. In 11th European College of Equine Internal Medicine Congress (ECEIM 2018)."},{"issue":"52","key":"B33","series-title":"J. Vet. Cardiol.","first-page":"19","article-title":"Detection of paroxysmal atrial fibrillation preceding persistent atrial fibrillation in a horse using an implantable loop recorder with remote monitoring","volume":"8","author":"Vernemmen, I.","year":"2024","unstructured":"Vernemmen, I., Van Steenkiste, G., Decloedt, A., Meert, H., Walser, U. and van Loon, G. (2024): Detection of paroxysmal atrial fibrillation preceding persistent atrial fibrillation in a horse using an implantable loop recorder with remote monitoring. J. Vet. Cardiol. 8(52), 19\u201327. https:\/\/doi.org\/10.1016\/j.jvc.2024.02.002."},{"key":"B34","series-title":"J. Equine Vet. Sci.","first-page":"61","article-title":"Evaluation of a smartphone electrocardiograph in healthy horses: comparison with standard base-apex electrocardiography","volume":"67","author":"Vezzosi, T.","year":"2018","unstructured":"Vezzosi, T., Sgorbini, M., Bonelli, F., Buralli, C., Pillotti, M., Meucci, V. and Tognetti, R. (2018): Evaluation of a smartphone electrocardiograph in healthy horses: comparison with standard base-apex electrocardiography. J. Equine Vet. Sci. 67, 61\u201365. https:\/\/doi.org\/10.1016\/j.jevs.2018.03.006."},{"key":"B35","series-title":"J. Equine Vet. Sci.","first-page":"127","article-title":"Two methods for 24-hour Holter monitoring in horses: evaluation of recording performance at rest and during exercise","volume":"79","author":"Vezzosi, T.","year":"2019","unstructured":"Vezzosi, T., Vitale, V., Sgorbini, M., Tognetti, R. and Bonelli, F. (2019): Two methods for 24-hour Holter monitoring in horses: evaluation of recording performance at rest and during exercise. J. Equine Vet. Sci. 79, 127\u2013130."},{"issue":"4","key":"B36","series-title":"J. Small Anim. Pract.","first-page":"181","article-title":"Use of an implantable loop recorder to investigate syncope in a cat","volume":"44","author":"Willis, R.","year":"2003","unstructured":"Willis, R., McLeod, K., Cusack, J. and Wotton, P. (2003): Use of an implantable loop recorder to investigate syncope in a cat. J. Small Anim. Pract. 44(4), 181\u2013183. https:\/\/doi.org\/10.1111\/j.1748-5827.2003.tb00142.x."}],"container-title":["Acta Veterinaria Hungarica"],"original-title":[],"link":[{"URL":"https:\/\/akjournals.com\/view\/journals\/004\/72\/3\/article-p178.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/akjournals.com\/downloadpdf\/journals\/004\/72\/3\/article-p178.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/akjournals.com\/downloadpdf\/journals\/004\/72\/3\/article-p178.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,12]],"date-time":"2024-09-12T16:00:20Z","timestamp":1726156820000},"score":1,"resource":{"primary":{"URL":"https:\/\/akjournals.com\/view\/journals\/004\/72\/3\/article-p178.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,12]]},"references-count":35,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.1556\/004.2024.01075","relation":{},"ISSN":["0236-6290","1588-2705"],"issn-type":[{"type":"print","value":"0236-6290"},{"type":"electronic","value":"1588-2705"}],"subject":[],"published":{"date-parts":[[2024,9,12]]}}}