{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,31]],"date-time":"2026-07-31T00:25:19Z","timestamp":1785457519786,"version":"3.56.0"},"reference-count":29,"publisher":"Akademiai Kiado Zrt.","issue":"3","license":[{"start":{"date-parts":[[2022,1,16]],"date-time":"2022-01-16T00:00:00Z","timestamp":1642291200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["akjournals.com"],"crossmark-restriction":true},"short-container-title":["OH"],"published-print":{"date-parts":[[2022,1,16]]},"abstract":"<jats:p><jats:bold>\u00d6sszefoglal\u00f3.<\/jats:bold>\n                    <jats:italic>Bevezet\u00e9s:<\/jats:italic> Az aortabetegs\u00e9gek kezel\u00e9se sor\u00e1n az orvos \u00e1ltal\n                    m\u00f3dos\u00edtott sztentgraftok alkalmaz\u00e1sa vitatott. D\u00f6nt\u0151en s\u00fcrg\u0151ss\u00e9gi esetben, nagy\n                    rizik\u00f3j\u00fa nyitott m\u0171t\u00e9t alternat\u00edv\u00e1jak\u00e9nt vagy neh\u00e9z anat\u00f3miai konfigur\u00e1ci\u00f3k\n                    eset\u00e9n alkalmazz\u00e1k \u0151ket. <jats:italic>M\u00f3dszer:<\/jats:italic> Cikk\u00fcnkben h\u00e1rom eseten\n                    kereszt\u00fcl klinik\u00e1nk kezdeti tapasztalatait mutatjuk be az orvos \u00e1ltal a m\u0171t\u00e9t\n                    sor\u00e1n m\u00f3dos\u00edtott sztentgraftokkal kapcsolatosan. <jats:italic>Eredm\u00e9nyek:<\/jats:italic>\n                    Els\u0151 eset\u00fcnkben egy 75 \u00e9ves f\u00e9rfi beteg 50 mm-es saccularis infrarenalis\n                    aortaaneurysma miatt ker\u00fclt felv\u00e9telre. A r\u00f6vid infrarenalis t\u00e1gulat proximalis\n                    r\u00f6gz\u00edt\u00e9si z\u00f3n\u00e1j\u00e1nak \u00e1tm\u00e9r\u0151je l\u00e9nyegesen nagyobb volt, mint a termin\u00e1lis\n                    aortaszakasz. A kaliberdiszkrepancia megold\u00e1s\u00e1ra a legalkalmasabb egy reverz\n                    helyzet\u0171 iliacagraftsz\u00e1r volt, \u00edgy egy graftsz\u00e1rat a felvezet\u0151rendszer\u00e9r\u0151l\n                    elt\u00e1vol\u00edtottunk, majd megford\u00edtva az aorta t\u00e1gulat\u00e1ba depon\u00e1ltuk. Hasonl\u00f3\n                    megold\u00e1st v\u00e1lasztottunk egy 67 \u00e9ves f\u00e9rfi beteg jobb oldali, 65 mm-es arteria\n                    iliaca communis aneurysm\u00e1j\u00e1nak kezel\u00e9se sor\u00e1n. Egy 81 \u00e9ves n\u0151beteg hasi\n                    aortaaneurysma tartott ruptur\u00e1ja miatt kor\u00e1bban behelyezett unilateralis graft\n                    proximalis endoleakj\u00e9nek megold\u00e1sa miatt \u00e9rkezett. Az ectaticus aorta, valamint\n                    az arteria mesenterica superior \u00e9s a primer intervenci\u00f3 sor\u00e1n beker\u00fclt\n                    unilateralis graft elkeskenyed\u0151 r\u00e9sze k\u00f6zti r\u00f6vid t\u00e1vols\u00e1g miatt konvencion\u00e1lis\n                    sztentgraft be\u00fcltet\u00e9se nem volt lehets\u00e9ges. A szitu\u00e1ci\u00f3 egy r\u00f6vid thoracalis\n                    sztentgrafttal volt megoldhat\u00f3: egy thoracalis sztentgraft distalis v\u00e9g\u00e9b\u0151l 3\n                    cm-t kauter seg\u00edts\u00e9g\u00e9vel lev\u00e1gtunk, majd az eszk\u00f6zt a felvezet\u0151rendszerbe\n                    visszat\u00f6lt\u00f6tt\u00fck. A m\u00f3dos\u00edtott sztentgraftot az arteria mesenterica superior al\u00e1\n                    pozicion\u00e1ltuk, egy \u2019chimney\u2019 sztentgraft seg\u00edts\u00e9g\u00e9vel biztos\u00edtottuk a jobb vese\n                    perf\u00fazi\u00f3j\u00e1t. Technikailag mindh\u00e1rom beavatkoz\u00e1sunk sikeres volt.\n                        <jats:italic>K\u00f6vetkeztet\u00e9s:<\/jats:italic> Az endovascularis aortam\u0171t\u00e9tek azonnal\n                    el\u00e9rhet\u0151 eszk\u00f6zparkja a t\u00edpusos anat\u00f3mi\u00e1j\u00fa betegek megold\u00e1s\u00e1ra \u00e1ltal\u00e1ban\n                    alkalmas. A szokatlan anat\u00f3mi\u00e1val rendelkez\u0151 elekt\u00edv esetek, illetve a s\u00fcrget\u0151\n                    beavatkoz\u00e1st ig\u00e9nyl\u0151 komplex endovascularis m\u0171t\u00e9tek sor\u00e1n az orvos \u00e1ltal\n                    m\u00f3dos\u00edtott sztentgraftok hat\u00e9konyan alkalmazhat\u00f3k. Alkalmaz\u00e1suk nagy forgalm\u00fa\n                    aortacentrumokban javasolt. Orv Hetil. 2022; 163(3): 109\u2013115.<\/jats:p>\n                <jats:p><jats:bold>Summary.<\/jats:bold>\n                    <jats:italic>Introduction:<\/jats:italic> Physician-modified endografts are mainly used in\n                    urgent cases of aortic disease as an alternative to high-risk open surgical\n                    repair or in difficult anatomical configurations. <jats:italic>Method:<\/jats:italic> We\n                    present our initial experiences with physician-modified stent graft\n                    implantation. <jats:italic>Results:<\/jats:italic> A 75-year-old male patient was admitted\n                    with a 50 mm saccular infrarenal aortic aneurysm. However, the diameter of the\n                    proximal sealing zone was significantly larger than that of the distal sealing\n                    zone, so we decided to use an iliac limb stent graft with reverse mounting\n                    resulting in an upside-down configuration to accommodate this diameter mismatch.\n                    A similar approach was used to treat a 67-year-old male patient with a 65 mm\n                    right common iliac artery aneurysm. An 81-year-old female patient was admitted\n                    with a type I endoleak associated with an aorto-uni-iliac endograft. The wide\n                    juxtarenal aortic diameter together with the short distance between the superior\n                    mesenteric artery and the proximal end of the previously deployed uni-iliac\n                    graft made the patient unsuitable for conventional endovascular repair, thus the\n                    distal 3 cm was cut from a standard thoracic stent graft and the device was\n                    reloaded. The modified graft was positioned below the superior mesenteric\n                    artery, while renal perfusion was secured by a chimney graft. Technical success\n                    was obtained in all three cases. <jats:italic>Conclusion:<\/jats:italic> The available\n                    toolkit of endovascular aortic surgery is generally suitable for the treatment\n                    of patients with typical anatomy. In elective cases of patients with unusual\n                    anatomy, or in urgent cases with complex aortic pathologies, physician-modified\n                    endovascular graft implantation can be used effectively. Orv Hetil. 2022;\n                    163(3): 109\u2013115.<\/jats:p>","DOI":"10.1556\/650.2022.32338","type":"journal-article","created":{"date-parts":[[2022,1,18]],"date-time":"2022-01-18T22:02:31Z","timestamp":1642543351000},"page":"109-115","update-policy":"https:\/\/doi.org\/10.1556\/policypage.crossmark.crossref.1","source":"Crossref","is-referenced-by-count":2,"title":["Kezdeti tapasztalataink az orvos \u00e1ltal m\u00f3dos\u00edtott sztentgraftok alkalmaz\u00e1s\u00e1val"],"prefix":"10.1556","volume":"163","author":[{"given":"Sarolta","family":"Borzs\u00e1k","sequence":"first","affiliation":[{"name":"Semmelweis Egyetem, \u00c1ltal\u00e1nos Orvostudom\u00e1nyi Kar, V\u00e1rosmajori Sz\u00edv- \u00e9s \u00c9rgy\u00f3gy\u00e1szati Klinika, Intervenci\u00f3s Radiol\u00f3giai Tansz\u00e9k Budapest, Hat\u00e1r\u0151r \u00fat 18., 1122"},{"name":"Semmelweis Egyetem, \u00c1ltal\u00e1nos Orvostudom\u00e1nyi Kar, V\u00e1rosmajori Sz\u00edv- \u00e9s \u00c9rgy\u00f3gy\u00e1szati Klinika, Semmelweis Aortacentrum Budapest"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Csongor","family":"P\u00e9ter","sequence":"additional","affiliation":[{"name":"Semmelweis Egyetem, \u00c1ltal\u00e1nos Orvostudom\u00e1nyi Kar, V\u00e1rosmajori Sz\u00edv- \u00e9s \u00c9rgy\u00f3gy\u00e1szati Klinika, Intervenci\u00f3s Radiol\u00f3giai Tansz\u00e9k Budapest, Hat\u00e1r\u0151r \u00fat 18., 1122"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ferenc","family":"Suhai","sequence":"additional","affiliation":[{"name":"Semmelweis Egyetem, \u00c1ltal\u00e1nos Orvostudom\u00e1nyi Kar, V\u00e1rosmajori Sz\u00edv- \u00e9s \u00c9rgy\u00f3gy\u00e1szati Klinika, Intervenci\u00f3s Radiol\u00f3giai Tansz\u00e9k Budapest, Hat\u00e1r\u0151r \u00fat 18., 1122"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zolt\u00e1n","family":"Szeberin","sequence":"additional","affiliation":[{"name":"Semmelweis Egyetem, \u00c1ltal\u00e1nos Orvostudom\u00e1nyi Kar, V\u00e1rosmajori Sz\u00edv- \u00e9s \u00c9rgy\u00f3gy\u00e1szati Klinika, Semmelweis Aortacentrum Budapest"},{"name":"Semmelweis Egyetem, \u00c1ltal\u00e1nos Orvostudom\u00e1nyi Kar, V\u00e1rosmajori Sz\u00edv- \u00e9s \u00c9rgy\u00f3gy\u00e1szati Klinika, \u00c9rseb\u00e9szeti \u00e9s Endovaszkul\u00e1ris Tansz\u00e9k Budapest"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Csaba","family":"Csobay-Nov\u00e1k","sequence":"additional","affiliation":[{"name":"Semmelweis Egyetem, \u00c1ltal\u00e1nos Orvostudom\u00e1nyi Kar, V\u00e1rosmajori Sz\u00edv- \u00e9s \u00c9rgy\u00f3gy\u00e1szati Klinika, Intervenci\u00f3s Radiol\u00f3giai Tansz\u00e9k Budapest, Hat\u00e1r\u0151r \u00fat 18., 1122"},{"name":"Semmelweis Egyetem, \u00c1ltal\u00e1nos Orvostudom\u00e1nyi Kar, V\u00e1rosmajori Sz\u00edv- \u00e9s \u00c9rgy\u00f3gy\u00e1szati Klinika, Semmelweis Aortacentrum Budapest"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"425","reference":[{"key":"ref0","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1016\/j.ejvs.2018.09.020","article-title":"Editor's choice - European Society for Vascular Surgery (ESVS) 2019 clinical practice guidelines on the management of abdominal aorto-iliac artery aneurysms","volume":"57","author":"1 Wanhainen","year":"2019","unstructured":"1 Wanhainen A, Verzini F, Van Herzeele I, et al. Editor's choice - European Society for Vascular Surgery (ESVS) 2019 clinical practice guidelines on the management of abdominal aorto-iliac artery aneurysms. Eur J Vasc Endovasc Surg. 2019; 57: 8-93.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"ref1","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1177\/1526602815611887","article-title":"Systematic review of off-the-shelf or physician-modified fenestrated and branched endografts","volume":"23","author":"2 Georgiadis","year":"2016","unstructured":"2 Georgiadis GS, van Herwaarden JA, Antoniou GA, et al. Systematic review of off-the-shelf or physician-modified fenestrated and branched endografts. J Endovasc Ther. 2016; 23: 98-109.","journal-title":"J Endovasc Ther"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"529","DOI":"10.1016\/j.ejvs.2010.01.004","article-title":"Fenestrated stent grafting for short-necked and juxtarenal abdominal aortic aneurysm: an 8-year single-centre experience","volume":"39","author":"3 Verhoeven","year":"2010","unstructured":"3 Verhoeven EL, Vourliotakis G, Bos WT, et al. Fenestrated stent grafting for short-necked and juxtarenal abdominal aortic aneurysm: an 8-year single-centre experience. Eur J Vasc Endovasc Surg. 2010; 39: 529-536.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"ref3","doi-asserted-by":"publisher","unstructured":"4 Oderich GS. Commentary: Physician-modified vs off-the-shelf fenestrated and branched endografts: is this a fair comparison? J Endovasc Ther. 2016; 23: 110-114.","DOI":"10.1177\/1526602815613520"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"601","DOI":"10.1016\/j.jvs.2012.02.011","article-title":"Physician-modified endovascular grafts for the treatment of elective, symptomatic, or ruptured juxtarenal aortic aneurysms","volume":"56","author":"5 Starnes","year":"2012","unstructured":"5 Starnes BW. Physician-modified endovascular grafts for the treatment of elective, symptomatic, or ruptured juxtarenal aortic aneurysms. J Vasc Surg. 2012; 56: 601-607.","journal-title":"J Vasc Surg"},{"key":"ref5","doi-asserted-by":"publisher","first-page":"1935","DOI":"10.1097\/01.RVI.0000248828.92093.1A","article-title":"Clinical experience with a customized fenestrated endograft for juxtarenal abdominal aortic aneurysm repair","volume":"17","author":"6 Uflacker","year":"2006","unstructured":"6 Uflacker R, Robison JD, Schonholz C, et al. Clinical experience with a customized fenestrated endograft for juxtarenal abdominal aortic aneurysm repair. J Vasc Interv Radiol. 2006; 17: 1935-1942.","journal-title":"J Vasc Interv Radiol"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"607","DOI":"10.1177\/1538574418789023","article-title":"Physician-modified fenestrated endografts for managing the ruptured or symptomatic aortic aneurysm: technique overview and clinical outcomes","volume":"52","author":"7 Singh","year":"2018","unstructured":"7 Singh A, Mafeld S, Williams R, et al. Physician-modified fenestrated endografts for managing the ruptured or symptomatic aortic aneurysm: technique overview and clinical outcomes. Vasc Endovascular Surg. 2018; 52: 607-612.","journal-title":"Vasc Endovascular Surg"},{"key":"ref7","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1016\/j.ejvs.2017.11.012","article-title":"Fenestrated thoracic endovascular aortic repair using physician modified stent grafts for acute type B aortic dissection with unfavourable landing zone","volume":"55","author":"8 Zhu","year":"2018","unstructured":"8 Zhu J, Zhao L, Dai X, et al. Fenestrated thoracic endovascular aortic repair using physician modified stent grafts for acute type B aortic dissection with unfavourable landing zone. Eur J Vasc Endovasc Surg. 2018; 55: 170-176.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"ref8","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1177\/152660280100800102","article-title":"Endoluminal aortic grafting with renal and superior mesenteric artery incorporation by graft fenestration","volume":"8","author":"9 Anderson","year":"2001","unstructured":"9 Anderson JL, Berce M, Hartley DE. Endoluminal aortic grafting with renal and superior mesenteric artery incorporation by graft fenestration. J Endovasc Ther. 2001; 8: 3-15.","journal-title":"J Endovasc Ther"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"1535","DOI":"10.1016\/j.jvs.2012.05.096","article-title":"Surgeon-modified fenestrated-branched stent grafts to treat emergently ruptured and symptomatic complex aortic aneurysms in high-risk patients","volume":"56","author":"Ricotta JJ 2nd","year":"2012","unstructured":"10 Ricotta JJ 2nd, Tsilimparis N. Surgeon-modified fenestrated-branched stent grafts to treat emergently ruptured and symptomatic complex aortic aneurysms in high-risk patients. J Vasc Surg. 2012; 56: 1535-1542.","journal-title":"J Vasc Surg"},{"key":"ref10","doi-asserted-by":"publisher","unstructured":"11 Scali ST, Waterman A, Feezor RJ, et al. Treatment of acute visceral aortic pathology with fenestrated\/branched endovascular repair in high-surgical-risk patients. J Vasc Surg. 2013; 58: 56-65.e1.","DOI":"10.1016\/j.jvs.2012.12.043"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1016\/j.ejvs.2015.07.002","article-title":"Early results of physician modified fenestrated stent grafts for the treatment of thoraco-abdominal aortic aneurysms","volume":"50","author":"12 Cochennec","year":"2015","unstructured":"12 Cochennec F, Kobeiter H, Gohel M, et al. Early results of physician modified fenestrated stent grafts for the treatment of thoraco-abdominal aortic aneurysms. Eur J Vasc Endovasc Surg. 2015; 50: 583-592.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"ref12","doi-asserted-by":"publisher","unstructured":"13 S\u00e9n\u00e9maud JN, Ben Abdallah I, de Boissieu P, et al. Intraoperative adverse events and early outcomes of custom-made fenestrated stent grafts and physician-modified stent grafts for complex aortic aneurysms. J Vasc Surg. 2020; 71: 1834-1842.e1.","DOI":"10.1016\/j.jvs.2019.07.102"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"311","DOI":"10.1016\/j.jvs.2013.01.029","article-title":"Early report from an investigator-initiated investigational device exemption clinical trial on physician-modified endovascular grafts","volume":"58","author":"Starnes BW","year":"2013","unstructured":"14 Starnes BW, Tatum B. Early report from an investigator-initiated investigational device exemption clinical trial on physician-modified endovascular grafts. J Vasc Surg. 2013; 58: 311-317.","journal-title":"J Vasc Surg"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"1160","DOI":"10.1016\/j.jvs.2015.05.036","article-title":"Endovascular treatment of thoracoabdominal aortic aneurysm using physician-modified endografts","volume":"62","author":"15 Sweet","year":"2015","unstructured":"15 Sweet MP, Starnes BW, Tatum B. Endovascular treatment of thoracoabdominal aortic aneurysm using physician-modified endografts. J Vasc Surg. 2015; 62: 1160-1167.","journal-title":"J Vasc Surg"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1016\/j.jvs.2016.07.123","article-title":"Midterm results from a physician-sponsored investigational device exemption clinical trial evaluating physician-modified endovascular grafts for the treatment of juxtarenal aortic aneurysms","volume":"65","author":"16 Starnes","year":"2017","unstructured":"16 Starnes BW, Heneghan RE, Tatum B. Midterm results from a physician-sponsored investigational device exemption clinical trial evaluating physician-modified endovascular grafts for the treatment of juxtarenal aortic aneurysms. J Vasc Surg. 2017; 65: 294-302.","journal-title":"J Vasc Surg"},{"key":"ref16","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1016\/j.ejvs.2017.11.003","article-title":"Endovascular repair of acute thoraco-abdominal aortic aneurysms","volume":"55","author":"17 Mascoli","year":"2018","unstructured":"17 Mascoli C, Vezzosi M, Koutsoumpelis A, et al. Endovascular repair of acute thoraco-abdominal aortic aneurysms. Eur J Vasc Endovasc Surg. 2018; 55: 92-100.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"560","DOI":"10.1016\/j.ejvs.2021.01.019","article-title":"Comprehensive review of physician modified aortic stent grafts: technical and clinical outcomes","volume":"61","author":"18 Canonge","year":"2021","unstructured":"18 Canonge J, Jayet J, Heim F, et al. Comprehensive review of physician modified aortic stent grafts: technical and clinical outcomes. Eur J Vasc Endovasc Surg. 2021; 61: 560-569.","journal-title":"Eur J Vasc Endovasc Surg"},{"key":"ref18","doi-asserted-by":"publisher","unstructured":"19 Oderich GS, Ribeiro MS, Sandri GA, et al. Evolution from physician-modified to company-manufactured fenestrated-branched endografts to treat pararenal and thoracoabdominal aortic aneurysms. J Vasc Surg. 2019; 70: 31-42.e7.","DOI":"10.1016\/j.jvs.2018.09.063"},{"key":"ref19","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1177\/1538574408322661","article-title":"Successful endovascular exclusion of a common iliac artery aneurysm: off-label use of a reversed Cook Zenith extension limb stent-graft","volume":"43","author":"Leon LR Jr.","year":"2009","unstructured":"20 Leon LR Jr., Mills JL Sr. Successful endovascular exclusion of a common iliac artery aneurysm: off-label use of a reversed Cook Zenith extension limb stent-graft. Vasc Endovascular Surg. 2009; 43: 76-82.","journal-title":"Vasc Endovascular Surg"},{"key":"ref20","doi-asserted-by":"publisher","first-page":"38","DOI":"10.5758\/vsi.2014.30.1.38","article-title":"Use of reversed iliac leg stent-graft for the treatment of isolated aneurysm of internal iliac artery","volume":"30","author":"21 Song","year":"2014","unstructured":"21 Song KS, Lee H, Nam DH, et al. Use of reversed iliac leg stent-graft for the treatment of isolated aneurysm of internal iliac artery. Vasc Specialist Int. 2014; 30: 38-42.","journal-title":"Vasc Specialist Int"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"381","DOI":"10.1177\/1708538113516444","article-title":"Off-label use of a reversed flared endurant iliac limb stentgraft for the management of a life-threatening internal iliac artery aneurysm rupture","volume":"22","author":"22 Gemayel","year":"2014","unstructured":"22 Gemayel G, Murith N, Kalangos A. Off-label use of a reversed flared endurant iliac limb stentgraft for the management of a life-threatening internal iliac artery aneurysm rupture. Vascular 2014; 22: 381-384.","journal-title":"Vascular"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1177\/1526602815581595","article-title":"Endovascular repair of aortic coarctation pseudoaneurysm using an off-label \"hourglass\" stent-graft configuration","volume":"22","author":"23 Erben","year":"2015","unstructured":"23 Erben Y, Oderich GS, Duncan AA. Endovascular repair of aortic coarctation pseudoaneurysm using an off-label \"hourglass\" stent-graft configuration. J Endovasc Ther. 2015; 22: 460-465.","journal-title":"J Endovasc Ther"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"762","DOI":"10.1583\/11-3554.1","article-title":"Use of the reversed Zenith iliac limb extension in the treatment of iliac artery aneurysms and various aortoiliac pathologies: outcome in midterm follow-up","volume":"18","author":"24 Peppelenbosch","year":"2011","unstructured":"24 Peppelenbosch AG, de Haan MW, Daemen JW, et al. Use of the reversed Zenith iliac limb extension in the treatment of iliac artery aneurysms and various aortoiliac pathologies: outcome in midterm follow-up. J Endovasc Ther. 2011; 18: 762-767.","journal-title":"J Endovasc Ther"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"1738","DOI":"10.1016\/j.jvs.2010.11.108","article-title":"The upside down Gore Excluder contralateral leg without extracorporeal predeployment for aortic or iliac aneurysm exclusion","volume":"53","author":"25 van der Steenhoven","year":"2011","unstructured":"25 van der Steenhoven TJ, Heyligers JM, Tielliu IF, et al. The upside down Gore Excluder contralateral leg without extracorporeal predeployment for aortic or iliac aneurysm exclusion. J Vasc Surg. 2011; 53: 1738-1741.","journal-title":"J Vasc Surg"},{"key":"ref25","doi-asserted-by":"publisher","first-page":"1068","DOI":"10.1007\/s00270-013-0802-0","article-title":"Upside down use of Gore Excluder or Cook Zenith legs","volume":"37","author":"26 Higashigawa","year":"2014","unstructured":"26 Higashigawa T, Kato N, Hashimoto T, et al. Upside down use of Gore Excluder or Cook Zenith legs. Cardiovasc Intervent Radiol. 2014; 37: 1068-1072.","journal-title":"Cardiovasc Intervent Radiol"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1177\/1526602816644913","article-title":"Physician modification to shorten a TAG thoracic endoprosthesis for treatment of a pseudoaneurysm in the ascending aorta","volume":"23","author":"27 Wada","year":"2016","unstructured":"27 Wada K, Shimamoto T, Komiya T, et al. Physician modification to shorten a TAG thoracic endoprosthesis for treatment of a pseudoaneurysm in the ascending aorta. J Endovasc Ther. 2016; 23: 489-492.","journal-title":"J Endovasc Ther"},{"key":"ref27","doi-asserted-by":"publisher","first-page":"1673","DOI":"10.1016\/j.jvs.2017.10.055","article-title":"Fenestrated endovascular aortic aneurysm repair using physician-modified endovascular grafts versus company-manufactured devices","volume":"67","author":"28 Dossabhoy","year":"2018","unstructured":"28 Dossabhoy SS, Simons JP, Flahive JM, et al. Fenestrated endovascular aortic aneurysm repair using physician-modified endovascular grafts versus company-manufactured devices. J Vasc Surg. 2018; 67: 1673-1683.","journal-title":"J Vasc Surg"},{"key":"ref28","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1016\/j.avsg.2020.02.022","article-title":"Low-profile Zenith Alpha\u2122 thoracic stent graft modification using preloaded wires for urgent repair of thoracoabdominal and pararenal abdominal aortic aneurysms","volume":"67","author":"29 Han","year":"2020","unstructured":"29 Han SM, Tenorio ER, Mirza AK, et al. Low-profile Zenith Alpha\u2122 thoracic stent graft modification using preloaded wires for urgent repair of thoracoabdominal and pararenal abdominal aortic aneurysms. Ann Vasc Surg. 2020; 67: 14-25.","journal-title":"Ann Vasc Surg"}],"container-title":["Orvosi Hetilap"],"original-title":[],"link":[{"URL":"https:\/\/akjournals.com\/view\/journals\/650\/163\/3\/article-p109.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/akjournals.com\/downloadpdf\/journals\/650\/163\/3\/article-p109.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/akjournals.com\/downloadpdf\/journals\/650\/163\/3\/article-p109.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,25]],"date-time":"2023-10-25T08:42:42Z","timestamp":1698223362000},"score":1,"resource":{"primary":{"URL":"https:\/\/akjournals.com\/view\/journals\/650\/163\/3\/article-p109.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,1,16]]},"references-count":29,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.1556\/650.2022.32338","relation":{},"ISSN":["0030-6002","1788-6120"],"issn-type":[{"value":"0030-6002","type":"print"},{"value":"1788-6120","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,1,16]]}}}