{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,12,13]],"date-time":"2024-12-13T05:20:28Z","timestamp":1734067228231,"version":"3.30.2"},"reference-count":41,"publisher":"Akademiai Kiado Zrt.","issue":"37","license":[{"start":{"date-parts":[[2024,9,15]],"date-time":"2024-09-15T00:00:00Z","timestamp":1726358400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["akjournals.com"],"crossmark-restriction":true},"short-container-title":["OH"],"published-print":{"date-parts":[[2024,9,15]]},"abstract":"<jats:p>Az eml\u0151r\u00e1k mortalit\u00e1sa \u00e9s morbidit\u00e1sa a mammogr\u00e1fi\u00e1s sz\u0171r\u0151program bevezet\u00e9s\u00e9vel\n                    szignifik\u00e1nsan cs\u00f6kkent. A teljes gy\u00f3gyul\u00e1s szempontj\u00e1b\u00f3l rendk\u00edv\u00fcl nagy\n                    jelent\u0151s\u00e9ge van a korai felismer\u00e9snek. A 2011-ben az FDA \u00e1ltal is elfogadott\n                    digit\u00e1lis 3D tomoszint\u00e9zis a digit\u00e1lis mammogr\u00e1fi\u00e1t (full-field digital\n                    mammography \u2013 FFDM) kieg\u00e9sz\u00edt\u0151 modalit\u00e1s, mely j\u00f3l alkalmazhat\u00f3 az\n                    eml\u0151betegs\u00e9gek diagnosztik\u00e1j\u00e1ban \u00e9s az eml\u0151r\u00e1k sz\u0171r\u00e9s\u00e9ben. A digit\u00e1lis 3D\n                    tomoszint\u00e9zis alapelve: a vizsg\u00e1lat sor\u00e1n egy adott k\u00f6r\u00edven mozg\u00f3 r\u00f6ntgencs\u0151 az\n                    eml\u0151r\u0151l \u2013 kis sug\u00e1rd\u00f3zissal \u2013 r\u00f6vid id\u0151 alatt 10\u201315 \u00e1tfed\u0151 digit\u00e1lis k\u00e9pet\n                    k\u00e9sz\u00edt. Az \u00edgy nyert adathalmazb\u00f3l sz\u00e1m\u00edt\u00f3g\u00e9pes feldolgoz\u00e1ssal v\u00e9kony\n                    szeletvastags\u00e1g\u00fa r\u00e9tegk\u00e9pek (3D tomoszint\u00e9zis), valamint rekonstru\u00e1lt, a\n                    hagyom\u00e1nyos mammogr\u00e1fi\u00e1s k\u00e9phez hasonl\u00f3, \u00fan. szintetikus 2D k\u00e9pek is k\u00e9sz\u00fclnek.\n                    Az el\u0151ny\u00f6k mellett (nagyobb r\u00e1kfelismer\u00e9si ar\u00e1ny, a k\u00f3ros k\u00e9pletek, szerkezeti\n                    disztorzi\u00f3, aszimmetrikus denzit\u00e1s pontosabb meg\u00edt\u00e9l\u00e9se, a felesleges\n                    mintav\u00e9telek sz\u00e1m\u00e1nak cs\u00f6kken\u00e9se, a sz\u0171r\u00e9sben kisebb visszah\u00edv\u00e1si ar\u00e1ny) a\n                    h\u00e1tr\u00e1nyokkal kapcsolatos dilemm\u00e1k (p\u00e9ld\u00e1ul sug\u00e1rterhel\u00e9s, nagyobb t\u00e1rhelyig\u00e9ny)\n                    ismerete is fontos. Orv Hetil. 2024; 165(37): 1443\u20131451.<\/jats:p>","DOI":"10.1556\/650.2024.33113","type":"journal-article","created":{"date-parts":[[2024,10,1]],"date-time":"2024-10-01T10:31:24Z","timestamp":1727778684000},"page":"1443-1451","update-policy":"https:\/\/doi.org\/10.1556\/policypage.crossmark.crossref.2","source":"Crossref","is-referenced-by-count":0,"title":["A digit\u00e1lis 3D tomoszint\u00e9zises mammogr\u00e1fia az eml\u0151r\u00e1k diagnosztik\u00e1j\u00e1ban \u00e9s sz\u0171r\u00e9s\u00e9ben"],"prefix":"10.1556","volume":"165","author":[{"given":"T\u00fcnde","family":"Tasn\u00e1di","sequence":"first","affiliation":[{"name":"Oliva Med Mag\u00e1nklinika B\u00e9k\u00e9scsaba Magyarorsz\u00e1g"},{"name":"B\u00e9k\u00e9s V\u00e1rmegyei K\u00f6zponti K\u00f3rh\u00e1z, Dr. R\u00e9thy P\u00e1l Tagk\u00f3rh\u00e1z, Radiol\u00f3giai Oszt\u00e1ly B\u00e9k\u00e9scsaba, Gyulai \u00fat 18., 5600 Magyarorsz\u00e1g"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"425","reference":[{"key":"ref0","doi-asserted-by":"publisher","first-page":"209","DOI":"10.3322\/caac.21660","article-title":"Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries","volume":"71","author":"1 Sung","year":"2021","unstructured":"1 Sung H, Ferlay J, Siegel LR, et al. Global cancer statistics 2020: GLOBOCAN estimates of incidence and mortality worldwide for 36 cancers in 185 countries. CA Cancer J for Clin. 2021; 71: 209-249.","journal-title":"CA Cancer J for Clin"},{"key":"ref1","doi-asserted-by":"publisher","unstructured":"2 Smith RA, Duffy SW, Gabe R, et al. The randomized trials of breast cancer screening: what have we learned? Radiol Clin North Am. 2004; 42: 793-806.","DOI":"10.1016\/j.rcl.2004.06.014"},{"key":"ref2","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1111\/tbj.12354","article-title":"Insights from the breast cancer screening trials: how screening affects the natural history of breast cancer and implications for evaluating service screening programs","volume":"21","author":"3 Tab\u00e1r","year":"2015","unstructured":"3 Tab\u00e1r L, Yen AM, Wu WY, et al. Insights from the breast cancer screening trials: how screening affects the natural history of breast cancer and implications for evaluating service screening programs. Breast J. 2015; 21:13-20.","journal-title":"Breast J"},{"key":"ref3","doi-asserted-by":"publisher","first-page":"2839","DOI":"10.1002\/cncr.28199","article-title":"A failure analysis of invasive breast cancer: most deaths from disease occur in women not regularly screened","volume":"120","author":"4 Webb","year":"2014","unstructured":"4 Webb ML, Cady B, Michaelson JS, et al. A failure analysis of invasive breast cancer: most deaths from disease occur in women not regularly screened. Cancer 2014; 120: 2839-2846.","journal-title":"Cancer"},{"key":"ref4","doi-asserted-by":"publisher","first-page":"1405","DOI":"10.1016\/S0140-6736(03)13143-1","article-title":"Mammography service screening and mortality in breast cancer patients: 20 year follow-up before and after introduction of screening","volume":"361","author":"5 Tab\u00e1r","year":"2003","unstructured":"5 Tab\u00e1r L, Yen MF, Vitak B, et al. Mammography service screening and mortality in breast cancer patients: 20 year follow-up before and after introduction of screening. Lancet. 2003; 361: 1405-1410.","journal-title":"Lancet"},{"key":"ref5","doi-asserted-by":"publisher","unstructured":"6 Kleinknecht JH, Ciurea AI, Ciortea CA. Pros and cons for breast cancer screening with tomosynthesis - a review of the literature. Med Pharm Rep. 2020; 93: 335-341.","DOI":"10.15386\/mpr-1698"},{"key":"ref6","doi-asserted-by":"publisher","first-page":"655","DOI":"10.1148\/radiol.13131391","article-title":"Two-view digital breast tomosynthesis screening with synthetically reconstructed projection images: comparison with digital breast tomosynthesis with full-field digital mammographic images","volume":"271","author":"7 Skaane","year":"2014","unstructured":"7 Skaane P, Bandos AI, Eben EB, et al. Two-view digital breast tomosynthesis screening with synthetically reconstructed projection images: comparison with digital breast tomosynthesis with full-field digital mammographic images. Radiology 2014; 271: 655-663.","journal-title":"Radiology"},{"key":"ref7","doi-asserted-by":"publisher","unstructured":"8 McDonald ES, Oustimov A, Weinstein SP, et al. Effectiveness of digital breast tomosynthesis compared with digital mammography outcomes analysis from 3 years of breast cancer screening. JAMA Oncol. 2016; 2(6): 737-743. Erratum: JAMA Oncol. 2016; 2(4): 549.","DOI":"10.1001\/jamaoncol.2015.5536"},{"key":"ref8","doi-asserted-by":"publisher","unstructured":"9 Sidky EY, Reiser IS, Nishikawa RM, et al. Enhancing tissue structures with iterative image reconstruction for digital breast tomosynthesis. SPIE 2014; 9033: 90330W.","DOI":"10.1117\/12.2043776"},{"key":"ref9","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1148\/rg.2019180046","article-title":"Digital breast tomosynthesis: physics, artifacts, and quality control considerations","volume":"39","author":"10 Tirada","year":"2019","unstructured":"10 Tirada N, Li G, Dreizin D, et al. Digital breast tomosynthesis: physics, artifacts, and quality control considerations. Radiographics 2019; 39: 413-426.","journal-title":"Radiographics"},{"key":"ref10","doi-asserted-by":"publisher","unstructured":"11 Hakim CM, Chough DM, Ganott MA, et al. Digital breast tomosynthesis in the diagnostic environment: a subjective side-by-side review. Am J Roentgenol. 2010; 195: W172- W176.","DOI":"10.2214\/AJR.09.3244"},{"key":"ref11","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1148\/radiol.12120552","article-title":"Digital breast tomosynthesis versus supplemental diagnostic mammographic views for evaluation of noncalcified breast lesions","volume":"266","author":"12 Zuley","year":"2013","unstructured":"12 Zuley ML, Bandos AI, Ganott MA, et al. Digital breast tomosynthesis versus supplemental diagnostic mammographic views for evaluation of noncalcified breast lesions. Radiology 2013; 266: 89-95.","journal-title":"Radiology"},{"key":"ref12","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1148\/radiol.12121373","article-title":"Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program","volume":"267","author":"13 Skaane","year":"2013","unstructured":"13 Skaane P, Bandos AI, Gullien R, et al. Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program. Radiology 2013; 267: 47-56.","journal-title":"Radiology"},{"key":"ref13","doi-asserted-by":"publisher","first-page":"2061","DOI":"10.1007\/s00330-013-2820-3","article-title":"Prospective trial comparing full-field digital mammography (FFDM) versus combined FFDM and tomosynthesis in a population-based screening programme using independent double reading with arbitration","volume":"23","author":"14 Skaane","year":"2013","unstructured":"14 Skaane P, Bandos AI, Gullien R, et al. Prospective trial comparing full-field digital mammography (FFDM) versus combined FFDM and tomosynthesis in a population-based screening programme using independent double reading with arbitration. Eur Radiol. 2013; 23: 2061-2071.","journal-title":"Eur Radiol"},{"key":"ref14","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1016\/j.breast.2013.11.006","article-title":"Incremental effect from integrating 3D-mammography (tomosynthesis) with 2D-mammography: increased breast cancer detection evident for screening centres in a population-based trial","volume":"23","author":"15 Caumo","year":"2014","unstructured":"15 Caumo F, Bernardi D, Ciatto S, et al. Incremental effect from integrating 3D-mammography (tomosynthesis) with 2D-mammography: increased breast cancer detection evident for screening centres in a population-based trial. Breast 2014; 23: 76-80.","journal-title":"Breast"},{"key":"ref15","doi-asserted-by":"publisher","first-page":"1232","DOI":"10.1016\/j.ejca.2014.02.004","article-title":"Effect of integrating 3D-mammography (digital breast tomosynthesis) with 2D-mammography on radiologists' true-positive and false-positive detection in a population breast screening trial","volume":"50","author":"16 Bernardi","year":"2014","unstructured":"16 Bernardi D, Caumo F, Macaskill P, et al. Effect of integrating 3D-mammography (digital breast tomosynthesis) with 2D-mammography on radiologists' true-positive and false-positive detection in a population breast screening trial. Eur J Cancer 2014; 50: 1232-1238.","journal-title":"Eur J Cancer"},{"key":"ref16","doi-asserted-by":"publisher","unstructured":"17 Svahn TM, Chakraborty DP, Ikeda D, et al. Breast tomosynthesis and digital mammography: a comparison of diagnostic accuracy. Br J Radiol. 2012; 85: e1074-e1082.","DOI":"10.1259\/bjr\/53282892"},{"key":"ref17","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1148\/radiol.12120674","article-title":"Assessing radiologist performance using combined digital mammography and breast tomosynthesis compared with digital mammography alone: results of a multicenter, multireader trial","volume":"266","author":"18 Rafferty","year":"2013","unstructured":"18 Rafferty EA, Park JM, Philpotts LE, et al. Assessing radiologist performance using combined digital mammography and breast tomosynthesis compared with digital mammography alone: results of a multicenter, multireader trial. Radiology 2013; 266: 104-113.","journal-title":"Radiology"},{"key":"ref18","doi-asserted-by":"publisher","first-page":"788","DOI":"10.1148\/radiol.11103514","article-title":"Two-view and single-view tomosynthesis versus full-field digital mammography: high-resolution X-Ray imaging observer study","volume":"262","author":"19 Wallis","year":"2012","unstructured":"19 Wallis MG, Moa E, Zanca F, et al. Two-view and single-view tomosynthesis versus full-field digital mammography: high-resolution X-Ray imaging observer study. Radiology 2012; 262: 788-796.","journal-title":"Radiology"},{"key":"ref19","unstructured":"20 Forrai G, T\u00f3th Zs, Seb\u0151 \u00c9. et al. (eds.) Theoretical and practical handbook for breast diagnostic assistants. [Eml\u0151diagnosztikai asszisztensek elm\u00e9leti \u00e9s gyakorlati k\u00e9zik\u00f6nyve.] Orsz\u00e1gos K\u00f6zeg\u00e9szs\u00e9g\u00fcgyi Int\u00e9zet, Budapest, 2017. [Hungarian]"},{"key":"ref20","doi-asserted-by":"publisher","unstructured":"21 Tittmann J, Csan\u00e1di M, \u00c1gh T, et al. Review of the scientific literature on the use of automated breast ultrasound for screening. [Az automatiz\u00e1lt eml\u0151ultrahang-daganatsz\u0171r\u00e9s szakirodalmi \u00e1ttekint\u00e9se.] Orv Hetil. 2022; 163: 1374-1382. [Hungarian]","DOI":"10.1556\/650.2022.32565"},{"key":"ref21","doi-asserted-by":"publisher","first-page":"2499","DOI":"10.1001\/jama.2014.6095","article-title":"Breast cancer screening using tomosynthesis in combination with digital mammography","volume":"311","author":"22 Friedewald","year":"2014","unstructured":"22 Friedewald SM, Rafferty EA, Rose SL, et al. Breast cancer screening using tomosynthesis in combination with digital mammography. JAMA 2014; 311: 2499-2507.","journal-title":"JAMA"},{"key":"ref22","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1148\/radiol.2019182457","article-title":"Local tumor staging of breast cancer: digital mammography versus digital mammography plus tomosynthesis","volume":"291","author":"23 Fontaine","year":"2019","unstructured":"23 Fontaine M, Tourasse C, Pages E, et al. Local tumor staging of breast cancer: digital mammography versus digital mammography plus tomosynthesis. Radiology 2019; 291: 594-603.","journal-title":"Radiology"},{"key":"ref23","doi-asserted-by":"publisher","first-page":"1339","DOI":"10.2214\/AJR.15.14628","article-title":"Architectural distortion on mammography: correlation with pathologic outcomes and predictors of malignancy","volume":"205","author":"24 Bahl","year":"2015","unstructured":"24 Bahl M, Baker JA, Kinsey EN, et al. Architectural distortion on mammography: correlation with pathologic outcomes and predictors of malignancy. Am J Roentgenol. 2015; 205: 1339-1345.","journal-title":"Am J Roentgenol"},{"key":"ref24","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1148\/radiol.2016151999","article-title":"Tomosynthesis in the diagnostic setting: changing rates of BI-RADS final assessment over time","volume":"281","author":"25 Raghu","year":"2016","unstructured":"25 Raghu M, Durand MA, Andrejeva L, et al. Tomosynthesis in the diagnostic setting: changing rates of BI-RADS final assessment over time. Radiology 2016; 281: 54-61.","journal-title":"Radiology"},{"key":"ref25","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1007\/s11547-013-0941-z","article-title":"Accuracy of tumour size assessment in the preoperative staging of breast cancer: comparison of digital mammography, tomosynthesis, ultrasound and MRI","volume":"118","author":"26 Luparia","year":"2013","unstructured":"26 Luparia A, Mariscotti G, Durando M, et al. Accuracy of tumour size assessment in the preoperative staging of breast cancer: comparison of digital mammography, tomosynthesis, ultrasound and MRI. Radiol Med. 2013; 118: 1119-1136.","journal-title":"Radiol Med"},{"key":"ref26","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.1016\/j.crad.2013.07.006","article-title":"Assessment of extent of breast cancer: comparison between digital breast tomosynthesis and full-field digital mammography","volume":"68","author":"27 Mun","year":"2013","unstructured":"27 Mun HS, Kim HH, Shin HJ, et al. Assessment of extent of breast cancer: comparison between digital breast tomosynthesis and full-field digital mammography. Clin Radiol. 2013; 68: 1254-1259.","journal-title":"Clin Radiol"},{"key":"ref27","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1016\/j.ejso.2007.04.020","article-title":"The value of MRI compared to mammography in the assessment of tumour extent in invasive lobular carcinoma of the breast","volume":"34","author":"28 Mann","year":"2008","unstructured":"28 Mann RM, Veltman J, Barentsz JO, et al. The value of MRI compared to mammography in the assessment of tumour extent in invasive lobular carcinoma of the breast. Eur J Surg Oncol. 2008; 34: 135-142.","journal-title":"Eur J Surg Oncol"},{"key":"ref28","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.breast.2014.12.002","article-title":"Review of radiation dose estimates in digital breast tomosynthesis relative to those in two-view full-field digital mammography","volume":"24","author":"29 Svahn","year":"2015","unstructured":"29 Svahn TM, Houssami N, Sechopoulos I, et al. Review of radiation dose estimates in digital breast tomosynthesis relative to those in two-view full-field digital mammography. Breast 2015; 24: 93-99.","journal-title":"Breast"},{"key":"ref29","doi-asserted-by":"publisher","first-page":"638","DOI":"10.1111\/j.1524-4741.2011.01152.x","article-title":"Calcifications in the breast and digital breast tomosynthesis","volume":"17","author":"30 Kopans","year":"2011","unstructured":"30 Kopans D, Gavenonis S, Halpern E, et al. Calcifications in the breast and digital breast tomosynthesis. Breast J. 2011; 17: 638-644.","journal-title":"Breast J"},{"key":"ref30","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1007\/s00330-014-3402-8","article-title":"Characterisation of microcalcification clusters on 2D digital mammography (FFDM) and digital breast tomosynthesis (DBT): does DBT underestimate microcalcification clusters? Results of a multicentre study","volume":"25","author":"31 Tagliafico","year":"2015","unstructured":"31 Tagliafico A, Mariscotti G, Durando M, et al. Characterisation of microcalcification clusters on 2D digital mammography (FFDM) and digital breast tomosynthesis (DBT): does DBT underestimate microcalcification clusters? Results of a multicentre study. Eur Radiol. 2015; 25: 9-14.","journal-title":"Eur Radiol"},{"key":"ref31","doi-asserted-by":"publisher","first-page":"273","DOI":"10.2214\/AJR.13.11240","article-title":"Diagnostic accuracy and recall rates for digital mammography and digital mammography combined with one-view and two-view tomosynthesis: results of an enriched reader study","volume":"202","author":"32 Rafferty","year":"2014","unstructured":"32 Rafferty EA, Park, JM, Philpotts LE, et al. Diagnostic accuracy and recall rates for digital mammography and digital mammography combined with one-view and two-view tomosynthesis: results of an enriched reader study. Am J Roentgenol. 2014; 202: 273-281.","journal-title":"Am J Roentgenol"},{"key":"ref32","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1016\/S1470-2045(16)30101-2","article-title":"Breast cancer screening with tomosynthesis (3D mammography) with acquired or synthetic 2D mammography compared with 2D mammography alone (STORM-2): a population-based prospective study","volume":"17","author":"33 Bernardi","year":"2016","unstructured":"33 Bernardi D, Macaskill P, Pellegrini M, et al. Breast cancer screening with tomosynthesis (3D mammography) with acquired or synthetic 2D mammography compared with 2D mammography alone (STORM-2): a population-based prospective study. Lancet Oncol. 2016; 17: 1105-1113.","journal-title":"Lancet Oncol"},{"key":"ref33","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1148\/radiol.13130765","article-title":"Addition of tomosynthesis to conventional digital mammography: effect on image interpretation time of screening examinations","volume":"270","author":"34 Dang","year":"2014","unstructured":"34 Dang PA, Freer PE, Humphrey KL, et al. Addition of tomosynthesis to conventional digital mammography: effect on image interpretation time of screening examinations. Radiology 2014; 270: 49-56.","journal-title":"Radiology"},{"key":"ref34","doi-asserted-by":"publisher","first-page":"216","DOI":"10.2214\/AJR.13.11047","article-title":"Detection of Mammographically occult architectural distortion on digital breast tomosynthesis screening: initial clinical experience","volume":"203","author":"35 Partyka","year":"2014","unstructured":"35 Partyka L, Lourenco AP, Mainiero MB. Detection of Mammographically occult architectural distortion on digital breast tomosynthesis screening: initial clinical experience. Am J Roentgenol. 2014; 203: 216-222.","journal-title":"Am J Roentgenol"},{"key":"ref35","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1002\/jmrs.348","article-title":"A comparison of stereotactic and tomosynthesis-guided localisation of impalpable breast lesions","volume":"66","author":"36 Madeley","year":"2019","unstructured":"36 Madeley C, Kessell M, Madeley C, et al. A comparison of stereotactic and tomosynthesis-guided localisation of impalpable breast lesions. J Med Radiat Sci. 2019; 66: 170-176.","journal-title":"J Med Radiat Sci"},{"key":"ref36","unstructured":"37 Forrai G, Kov\u00e1cs E, Ambr\u00f3zay \u00c9, et al. Application of imaging diagnostic methods in the modern screening, diagnosis, and treatment of breast tumors - Professional guidelines based on the IV. Breast Cancer Consensus Conference. [A k\u00e9palkot\u00f3 vizsg\u00e1l\u00f3m\u00f3dszerek alkalmaz\u00e1sa az eml\u0151daganatok korszer\u0171 sz\u0171r\u00e9s\u00e9ben, diagnosztik\u00e1j\u00e1ban \u00e9s ell\u00e1t\u00e1s\u00e1ban-Szakmai \u00fatmutat\u00f3 a IV. Eml\u0151r\u00e1k Konszenzus Konferencia alapj\u00e1n.] Magy Onkol. 2020; 64: 278-299. [Hungarian]"},{"key":"ref37","doi-asserted-by":"publisher","first-page":"676","DOI":"10.2214\/AJR.05.1950","article-title":"Influence of mammographic parenchymal pattern in screening-detected and interval invasive breast cancers on pathologic features, mammographic features, and patient survival","volume":"188","author":"38 Porter","year":"2007","unstructured":"38 Porter GJ, Evans AJ, Cornford EJ, et al. Influence of mammographic parenchymal pattern in screening-detected and interval invasive breast cancers on pathologic features, mammographic features, and patient survival. Am J Roentgenol. 2007; 188: 676-683.","journal-title":"Am J Roentgenol"},{"key":"ref38","doi-asserted-by":"publisher","first-page":"1021","DOI":"10.1016\/j.ejca.2010.12.002","article-title":"Evidence of the effect of adjunct ultrasound screening in women with mammography-negative dense breasts: interval breast cancers at 1 year follow-up","volume":"47","author":"39 Corsetti","year":"2011","unstructured":"39 Corsetti V, Houssami N, Ghirardi M, et al. Evidence of the effect of adjunct ultrasound screening in women with mammography-negative dense breasts: interval breast cancers at 1 year follow-up. Eur J Cancer 2011; 47: 1021-1026.","journal-title":"Eur J Cancer"},{"key":"ref39","doi-asserted-by":"publisher","first-page":"347","DOI":"10.1148\/radiol.13122278","article-title":"Tailored breast cancer screening program with microdose mammography, US, and MR imaging: short-term results of a pilot study in 40-49-year-old women","volume":"268","author":"40 Venturini","year":"2013","unstructured":"40 Venturini E, Losio C, Panizza P, et al. Tailored breast cancer screening program with microdose mammography, US, and MR imaging: short-term results of a pilot study in 40-49-year-old women. Radiology 2013; 268: 347-355.","journal-title":"Radiology"},{"key":"ref40","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.ejca.2018.08.029","article-title":"A prospective comparative trial of adjunct screening with tomosynthesis or ultrasound in women with mammography-negative dense breasts (ASTOUND-2)","volume":"104","author":"41 Tagliafico","year":"2018","unstructured":"41 Tagliafico AS, Mariscotti G, Valdora F, et al. A prospective comparative trial of adjunct screening with tomosynthesis or ultrasound in women with mammography-negative dense breasts (ASTOUND-2). Eur J Cancer 2018; 104: 39-46.","journal-title":"Eur J Cancer"}],"container-title":["Orvosi Hetilap"],"original-title":[],"link":[{"URL":"https:\/\/akjournals.com\/view\/journals\/650\/165\/37\/article-p1443.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/akjournals.com\/downloadpdf\/journals\/650\/165\/37\/article-p1443.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/akjournals.com\/downloadpdf\/journals\/650\/165\/37\/article-p1443.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,12]],"date-time":"2024-12-12T08:13:14Z","timestamp":1733991194000},"score":1,"resource":{"primary":{"URL":"https:\/\/akjournals.com\/view\/journals\/650\/165\/37\/article-p1443.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,9,15]]},"references-count":41,"journal-issue":{"issue":"37"},"URL":"https:\/\/doi.org\/10.1556\/650.2024.33113","relation":{},"ISSN":["0030-6002","1788-6120"],"issn-type":[{"type":"print","value":"0030-6002"},{"type":"electronic","value":"1788-6120"}],"subject":[],"published":{"date-parts":[[2024,9,15]]}}}