{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T06:59:48Z","timestamp":1760079588909},"reference-count":37,"publisher":"Akademiai Kiado Zrt.","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2012,3,1]]},"abstract":"<jats:p>In the present series of cases, 8 laparoscopic cryptorchidectomies and 4 laparoscopic ovariectomies were carried out in sedated standing horses. Sedation involved a lesser anaesthesiological risk than does general anaesthesia. As compared to laparotomic exposure, the minimally invasive laparoscopic intervention provided better visualisation, shorter operative time and faster recovery. The blood vessels supplying the testes and ovaries and the suspensory ligaments of the organs were sealed and cut with EnSeal\u00ae, an adaptive bipolar electrosurgical blood vessel- and tissue-sealing device. The clinical use of the blood vessel- and tissue-sealing device proved to be successful in all cases. Gradual separation of the intact tissue from the treated, compacted, dehydrated and homogenised tissue areas and occlusion of the lumen of blood vessels treated with the device could be observed in all histological sections. To the best of our knowledge, this is the first report on the use of EnSeal\u00ae for laparoscopic cryptorchidectomy and ovariectomy in horses.<\/jats:p>","DOI":"10.1556\/avet.2012.004","type":"journal-article","created":{"date-parts":[[2012,2,28]],"date-time":"2012-02-28T02:02:03Z","timestamp":1330394523000},"page":"41-53","source":"Crossref","is-referenced-by-count":7,"title":["Laparoscopic cryptorchidectomy and ovariectomy in standing horses using the EnSeal\u00ae tissue-sealing device"],"prefix":"10.1556","volume":"60","author":[{"given":"Mikl\u00f3s","family":"Dunay","sequence":"first","affiliation":[{"name":"1 Szent Istv\u00e1n University Department and Clinic of Surgery and Ophthalmology Budapest Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tibor","family":"N\u00e9meth","sequence":"additional","affiliation":[{"name":"1 Szent Istv\u00e1n University Department and Clinic of Surgery and Ophthalmology Budapest Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zita","family":"Makra","sequence":"additional","affiliation":[{"name":"2 Szent Istv\u00e1n University Clinic for Large Animals, Faculty of Veterinary Science Budapest Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon","family":"Izing","sequence":"additional","affiliation":[{"name":"2 Szent Istv\u00e1n University Clinic for Large Animals, Faculty of Veterinary Science Budapest Hungary"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G\u00e1bor","family":"Bod\u00f3","sequence":"additional","affiliation":[{"name":"3 University of Bern Equine Clinic, Department of Clinical Veterinary Medicine, Vetsuisse Faculty Bern Switzerland"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"425","reference":[{"key":"1","first-page":"43","article-title":"A preliminary comparison of mechanical compression amongst three electrosurgical devices","volume":"12","author":"Advincula A. P.","year":"2005","journal-title":"JMIG"},{"key":"2","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/j.juro.2008.08.122","article-title":"Comparative study of in vivo lymphatic sealing capability of the porcine thoracic duct using laparoscopic dissection devices","volume":"181","author":"Box G. N.","year":"2009","journal-title":"J. Urol."},{"key":"3","doi-asserted-by":"crossref","unstructured":"Brill, A. I. (2004): Mapping the thermal gradient of a new radiofrequency bipolar vessel sealing device, EnSeal, using real-time thermography. J. Am. Assoc. Gyn. Lap. <b>11<\/b>, No. 3, Supplement, S 7.","DOI":"10.1016\/S1074-3804(04)80277-9"},{"key":"4","doi-asserted-by":"crossref","first-page":"1640","DOI":"10.1007\/s00464-002-8781-2","article-title":"Real-time thermography during energized vessel sealing and dissection","volume":"17","author":"Campbell P. A.","year":"2003","journal-title":"Surg. Endosc."},{"key":"5","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1089\/109264203322656441","article-title":"A comparison of laparoscopic bipolar vessel sealing devices in the hemostasis of small-, medium- and large-sized arteries","volume":"13","author":"Carbonell A. M.","year":"2003","journal-title":"J. Laparoendosc. Adv. Surg. Tech."},{"key":"6","unstructured":"Damani, T., Advincula, A. and Way, L. W. (2005): Comparative thermal spread of three radiofrequency bipolar vessel sealing devices. Poster presented at the 2005 Annual Meeting of The Society of American Gastrointestinal and Endoscopic Surgeons (SAGES), Fort Lauderdale, FL, April 13\u201316, 2005."},{"key":"7","first-page":"737","article-title":"Standing laparoscopic ovariectomy technique with intraabdominal dissection for removal of large pathologic ovaries in mares","volume":"39","author":"Bont M. P.","year":"2010","journal-title":"Vet. Surg."},{"key":"8","unstructured":"D\u00e9nes, B., Torre, R. A., Krummel, T. M. and Oleson, L. S. M. (2003): Evaluation of a vessel sealing system in a porcine model. Poster presented at the 21st World Congress of Endourology (WCE), Montreal, Canada, September 2003."},{"key":"9","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1111\/j.1532-950X.2003.00501.x","article-title":"Complications associated with cannula insertion techniques used for laparoscopy in standing horses","volume":"32","author":"Desmaizi\u00e9res L.-M.","year":"2003","journal-title":"Vet. Surg."},{"key":"10","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1111\/j.1532-950X.2010.00740.x","article-title":"Electromagnetic energy sources in surgery","volume":"39","author":"Dubiel B.","year":"2010","journal-title":"Vet. Surg."},{"key":"11","doi-asserted-by":"crossref","first-page":"593","DOI":"10.2460\/javma.2005.227.593","article-title":"Intraoperative pain responses following intraovarian versus mesovarian injection of lidocaine in mares undergoing laparoscopic ovariectomy","volume":"227","author":"Farstvedt E. G.","year":"2005","journal-title":"J. Am. Vet. Med. Ass."},{"key":"12","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1089\/109264202753486957","article-title":"Comparison of thermal spread after ureteral ligation with the Laparo-Sonic ultrasonic shears and the LigaSure system","volume":"12","author":"Goldstein S. L.","year":"2002","journal-title":"J. Laparoendosc. Adv. Surg. Tech. A"},{"key":"13","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1053\/jvet.2002.33482","article-title":"Evaluation of a vessel-sealing device for use in laparoscopic ovariectomy in mares","volume":"31","author":"Hand R.","year":"2002","journal-title":"Vet. Surg."},{"key":"14","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1053\/jvet.31049","article-title":"Laparoscopic cryptorchidectomy using electrosurgical instrumentation in standing horses","volume":"31","author":"Hanrath M.","year":"2002","journal-title":"Vet. Surg."},{"key":"15","doi-asserted-by":"crossref","first-page":"1228","DOI":"10.1007\/s00464-002-8833-7","article-title":"Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries","volume":"17","author":"Harold K. L.","year":"2003","journal-title":"Surg. Endosc."},{"key":"16","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1016\/j.cveq.2006.08.006","article-title":"Laparoscopic cryptorchidectomy and ovariectomy in horses","volume":"22","author":"Hendrickson D.","year":"2006","journal-title":"Rev. Vet. Clin. North Am. Equine Pract."},{"key":"17","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1007\/s004640080025","article-title":"Initial results with an electrothermal bipolar vessel sealer","volume":"15","author":"Heniford B. T.","year":"2001","journal-title":"Surg. Endosc."},{"key":"18","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1111\/j.1532-950X.2006.00151.x","article-title":"Evaluation of a vessel-sealing device for laparoscopic granulosa cell tumor removal in standing mares","volume":"35","author":"Hubert J. D.","year":"2006","journal-title":"Vet. Surg."},{"key":"19","doi-asserted-by":"crossref","first-page":"876","DOI":"10.1007\/s004649900733","article-title":"High-burst-strength, feedback-controlled bipolar vessel sealing","volume":"12","author":"Kennedy J. S.","year":"1998","journal-title":"Surg. Endosc."},{"key":"20","doi-asserted-by":"crossref","first-page":"1464","DOI":"10.1007\/s00464-007-9650-9","article-title":"Temperature safety profile of laparoscopic devices: Harmonic ACE, LigaSure V, and plasma trissector","volume":"22","author":"Kim F. J.","year":"2008","journal-title":"Surg. Endosc."},{"key":"21","doi-asserted-by":"crossref","first-page":"2307","DOI":"10.1089\/end.2008.9715","article-title":"Prospective comparison of four laparoscopic vessel ligation devices","volume":"22","author":"Lamberton G. R.","year":"2008","journal-title":"J. Endourol."},{"key":"22","doi-asserted-by":"crossref","first-page":"210","DOI":"10.2746\/042516407X17116522","article-title":"Electrosurgery as the sole means of haemostasis during the laparoscopic removal of pathologically enlarged ovaries in mares: a report of 55 cases","volume":"39","author":"Lloyd D.","year":"2007","journal-title":"Equine Vet. J."},{"key":"23","doi-asserted-by":"crossref","first-page":"468","DOI":"10.2746\/042516405774479988","article-title":"Costs and complications of equine castration: a UK practice-based study comparing \u2019standing nonsutured\u2019 and\u2019 recumbent sutured\u2019 techniques","volume":"37","author":"Mason B. J.","year":"2005","journal-title":"Equine Vet. J."},{"key":"24","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1111\/j.1532-950X.2007.00280.x","article-title":"Comparison of three techniques for ovarian pedicle hemostasis during laparoscopic-assisted ovariohysterectomy","volume":"36","author":"Mayhew P. D.","year":"2007","journal-title":"Vet. Surg."},{"key":"25","doi-asserted-by":"crossref","first-page":"275","DOI":"10.1136\/vr.142.11.275","article-title":"A retrospective study of mortality associated with general anaesthesia in horses: elective procedures","volume":"142","author":"Mee A. M.","year":"1998","journal-title":"Vet. Rec."},{"key":"26","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1007\/s00464-008-9932-x","article-title":"Comparison of blood vessel sealing among new electrosurgical and ultrasonic devices","volume":"23","author":"Newcomb W. L.","year":"2009","journal-title":"Surg. Endosc."},{"key":"27","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1007\/s00464-007-9619-8","article-title":"Histopathologic comparison of four energy-based vascular sealing and cutting instruments: A porcine model","volume":"22","author":"Person B.","year":"2007","journal-title":"Surg. Endosc."},{"key":"28","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1053\/jvet.2001.28435","article-title":"Laparoscopic ovariectomy using sequential electrocoagulation and sharp transection of the equine mesovarium","volume":"30","author":"Rodgerson D. H.","year":"2001","journal-title":"Vet. Surg."},{"key":"29","first-page":"119","article-title":"Uni- and bilateral ovariectomy in the mare: retrospective comparative study of techniques in 116 clinical patients (in German)","volume":"37","author":"R\u00f6cken M.","year":"2009","journal-title":"Tier\u00e4rztl. Praxis"},{"key":"30","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1159\/000099599","article-title":"Histopathological effects of bipolar vessel sealing devices on liver parenchyma and comparison with suture method: An experimental study","volume":"39","author":"Sahin D. A.","year":"2007","journal-title":"Eur. Surg. Res."},{"key":"31","doi-asserted-by":"crossref","first-page":"242","DOI":"10.2746\/042516406776866354","article-title":"Use of transabdominal ultrasonography to determine the location of cryptorchid testes in the horse","volume":"38","author":"Schambourg M. A.","year":"2006","journal-title":"Equine Vet. J."},{"key":"32","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1111\/j.1751-0813.1999.tb12083.x","article-title":"Equine castration: review of anatomy, approaches, techniques and complications in normal, cryptorchid and monorchid horses","volume":"77","author":"Searle D.","year":"1999","journal-title":"Austr. Vet. J."},{"key":"33","doi-asserted-by":"crossref","first-page":"197","DOI":"10.2310\/6670.2010.00015","article-title":"Application of energy-based technologies and topical hemostatic agents in the management of surgical hemostasis","volume":"18","author":"Sileshi B.","year":"2010","journal-title":"Vasc."},{"key":"34","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1136\/vr.163.10.297","article-title":"Unilateral and bilateral laparoscopic ovariectomy of mares by electrocautery","volume":"163","author":"Smith L. J.","year":"2008","journal-title":"Vet. Rec."},{"key":"35","first-page":"13","article-title":"Laparoscopic cryptorchidectomy in standing horse using the LigaSure technology (in Italian)","volume":"19","author":"Varasano V.","year":"2008","journal-title":"Ippologia"},{"key":"36","doi-asserted-by":"crossref","first-page":"35","DOI":"10.2746\/042516406775374234","article-title":"The complex blood supply to the equine testis as a cause of failure in laparoscopic castration","volume":"38","author":"Voermans M.","year":"2006","journal-title":"Equine Vet. J."},{"key":"37","doi-asserted-by":"crossref","first-page":"1991","DOI":"10.1089\/end.2010.0392","article-title":"Application of ice cold irrigation during vascular pedicle control of robot-assisted radical prostatectomy: EnSeal instrument cooling to reduce collateral thermal tissue damage","volume":"24","author":"Zorn K. C.","year":"2010","journal-title":"J. Endourol."}],"container-title":["Acta Veterinaria Hungarica"],"original-title":[],"link":[{"URL":"https:\/\/akjournals.com\/view\/journals\/004\/60\/1\/article-p41.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/www.akademiai.com\/doi\/pdf\/10.1556\/avet.2012.004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,22]],"date-time":"2020-05-22T09:40:39Z","timestamp":1590140439000},"score":1,"resource":{"primary":{"URL":"https:\/\/akjournals.com\/doi\/10.1556\/avet.2012.004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,3,1]]},"references-count":37,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.1556\/avet.2012.004","relation":{},"ISSN":["0236-6290","1588-2705"],"issn-type":[{"value":"0236-6290","type":"print"},{"value":"1588-2705","type":"electronic"}],"subject":[],"published":{"date-parts":[[2012,3,1]]}}}