{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,12,27]],"date-time":"2022-12-27T15:34:40Z","timestamp":1672155280785},"reference-count":54,"publisher":"Akademiai Kiado Zrt.","issue":"43","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Orvosi Hetilap"],"published-print":{"date-parts":[[2014,10]]},"abstract":"<jats:p>Introduction: Lower limbs anatomical and biomechanical parameters are essential in several paediatric orthopaedic disease, which makes their exact measurement necessary. Aim: The aim of the author was to evaluate the reliability of the EOS 2D\/3D System, a 3D reconstruction capable imaging device in children. Method: 3D reconstructions were performed in 523 cases aged between 2 and 16 years in whom no abnormality influencing lower limbs biomechanics was observed. For statistical analysis intraclass correlation, paired-samples t-test, Spearman-correlation and Welch-test were used. Results: Excellent results were found for all parameters in reliability test used by the operator. The step-forward position used during the examination influenced the sagittal tibiofemoral angle only. All examined parameters showed significant correlation with age and gender. Height correlated with neck-shaft angle, hip-knee shift, femoral and tibial torsion only. Conclusions: The EOS technology proved to be an appropriate method to measure lower limbs anatomical parameters in children. Changes in these parameters during development correlated with age and gender. Orv., Hetil., 2014, 155(43), 1701\u20131711.<\/jats:p>","DOI":"10.1556\/oh.2014.30009","type":"journal-article","created":{"date-parts":[[2014,10,20]],"date-time":"2014-10-20T01:01:16Z","timestamp":1413766876000},"page":"1701-1712","source":"Crossref","is-referenced-by-count":3,"title":["Evaluation of the usefulness of the EOS 2D\/3D system for the measurement of lower limbs anatomical and biomechanical parameters in children"],"prefix":"10.1556","volume":"155","author":[{"given":"\u00c1d\u00e1m Tibor","family":"Schl\u00e9gl","sequence":"first","affiliation":[{"name":"P\u00e9csi Tudom\u00e1nyegyetem, Klinikai K\u00f6zpont MSI Ortop\u00e9diai Klinikai Tansz\u00e9k P\u00e9cs Ak\u00e1c u. 1. 7632"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kinga","family":"Szuper","sequence":"additional","affiliation":[{"name":"P\u00e9csi Tudom\u00e1nyegyetem, Klinikai K\u00f6zpont MSI Ortop\u00e9diai Klinikai Tansz\u00e9k P\u00e9cs Ak\u00e1c u. 1. 7632"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Szabolcs","family":"Somoske\u00f6y","sequence":"additional","affiliation":[{"name":"P\u00e9csi Tudom\u00e1nyegyetem, Klinikai K\u00f6zpont MSI Ortop\u00e9diai Klinikai Tansz\u00e9k P\u00e9cs Ak\u00e1c u. 1. 7632"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P\u00e9ter","family":"Than","sequence":"additional","affiliation":[{"name":"P\u00e9csi Tudom\u00e1nyegyetem, Klinikai K\u00f6zpont MSI Ortop\u00e9diai Klinikai Tansz\u00e9k P\u00e9cs Ak\u00e1c u. 1. 7632"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"425","reference":[{"key":"1","unstructured":"<i>Johnston, J. D., Noble, P. C., Hurwitz, D. E., et al.:<\/i> Biomechanics of the hip. In: <i>Callaghan, J. J.<\/i> (ed.): The Adult Hip. Lippincott Williams & Wilkins, Philadelphia, 1998."},{"key":"2","doi-asserted-by":"crossref","unstructured":"<i>Byrne, D. P., Mulhall, K. J., Baker, J. F.:<\/i> Anatomy and biomechanics of the hip. Op. Sports Med., 2010, <i>4,<\/i> 51\u201357.","DOI":"10.2174\/1874387001004010051"},{"key":"3","unstructured":"<i>Szendr\u0151i, M.:<\/i> Orthopedics. [Ortop\u00e9dia.] Semmelweis Kiad\u00f3, Budapest, 2009. [Hungarian]"},{"key":"4","doi-asserted-by":"crossref","unstructured":"<i>Schouten, J. S., van den Ouweland, F. A., Valkenburg, H. A.:<\/i> A 12 year follow up study in the general population on prognostic factors of cartilage loss in osteoarthritis of the knee. Ann. Rheum. Dis., 1992, <i>51<\/i>(8), 932\u2013937.","DOI":"10.1136\/ard.51.8.932"},{"key":"5","doi-asserted-by":"crossref","unstructured":"<i>Sharma, L., Song, J., Felson, D. T., et al.:<\/i> The role of knee alignment in disease progression and functional decline in knee osteoarthritis. JAMA, 2001, <i>286<\/i>(2), 188\u2013195.","DOI":"10.1001\/jama.286.2.188"},{"key":"6","unstructured":"Orthopedics Professional Body: Protocol of the Ministry of Health: Coxarthrosis. [Az Ortop\u00e9diai Szakmai Koll\u00e9gium: Az Eg\u00e9szs\u00e9g\u00fcgyi Miniszt\u00e9rium szakmai protokollja Coxarthrosis.] Budapest, 2008. [Hungarian] <a href=\"http:\/\/www.eum.hu\/egeszsegpolitika\/minosegfejlesztes\/ortopedia\">http:\/\/www.eum.hu\/egeszsegpolitika\/minosegfejlesztes\/ortopedia<\/a> [Hungarian]"},{"key":"7","doi-asserted-by":"crossref","unstructured":"<i>Chitnavis, J., Sinsheimer, J. S., Suchard, M. A., et al.:<\/i> End-stage coxarthrosis and gonarthrosis. Aetiology, clinical patterns and radiological features of idiopathic osteoarthritis. Rheumatology (Oxford), 2000, <i>39<\/i>(6), 612\u2013619.","DOI":"10.1093\/rheumatology\/39.6.612"},{"key":"8","doi-asserted-by":"crossref","unstructured":"<i>Westhoff, B., J\u00e4ger, M., Krauspe, R.:<\/i> Kindliche Beinachsen. Orthop\u00e4de, 2007, <i>36<\/i>(5), 485\u2013500.","DOI":"10.1007\/s00132-007-1088-1"},{"key":"9","unstructured":"<i>Moseley, C. F.:<\/i> Assessment and prediction in leg-length discrepancy. Instr. Course Lect., 1989, <i>38,<\/i> 325\u2013330."},{"key":"10","unstructured":"<i>Tokarowski, A., Piechota, L., Wojciechowski, P., et al.:<\/i> Measurement of lower extremity length using computed tomography. Chir. Narzadow Ruchu Orthop. Pol., 1995, <i>60<\/i>(2), 123\u2013127. [Polish]"},{"key":"11","doi-asserted-by":"crossref","unstructured":"<i>Gurney, B.:<\/i> Leg length discrepancy. Gait Posture, 2002, <i>15<\/i>(2), 195\u2013206.","DOI":"10.1016\/S0966-6362(01)00148-5"},{"key":"12","doi-asserted-by":"crossref","unstructured":"<i>Kraus, V. B., Vail, T. P., Worrell, T., et al.:<\/i> A comparative assessment of alignment angle of the knee by radiographic and physical examination methods. Arthritis Rheum., 2005, <i>52<\/i>(6), 1730\u20131735.","DOI":"10.1002\/art.21100"},{"key":"13","doi-asserted-by":"crossref","unstructured":"<i>Staheli, L. T., Corbett, M., Wyss, C., et al.:<\/i> Lower-extremity rotational problems in children. Normal values to guide management. J. Bone Joint Surg. Am., 1985, <i>67<\/i>(1), 39\u201347.","DOI":"10.2106\/00004623-198567010-00006"},{"key":"14","doi-asserted-by":"crossref","unstructured":"<i>Cooke, D., Scudamore, A., Li, J., et al.:<\/i> Axial lower-limb alignment: comparison of knee geometry in normal volunteers and osteoarthritis patients. Osteoarthritis Cartilage, 1997, <i>5<\/i>(1), 39\u201347.","DOI":"10.1016\/S1063-4584(97)80030-1"},{"key":"15","doi-asserted-by":"crossref","unstructured":"<i>Paley, D., Tetsworth, K.:<\/i> Mechanical axis deviation of the lower limbs. Preoperative planning of multiapical frontal plane angular and bowing deformities of the femur and tibia. Clin. Orthop. Relat. Res., 1992, <i>280,<\/i> 65\u201371.","DOI":"10.1097\/00003086-199207000-00009"},{"key":"16","doi-asserted-by":"crossref","unstructured":"<i>Takahashi, T., Yamanaka, N., Komatsu, M., et al.:<\/i> A new computer-assisted method for measuring the tibio-femoral angle in patients with osteoarthritis of the knee. Osteoarthritis Cartilage, 2004, <i>12<\/i>(3), 256\u2013259.","DOI":"10.1016\/j.joca.2003.10.005"},{"key":"17","doi-asserted-by":"crossref","unstructured":"<i>Cooke, T. D., Scudamore, R. A., Bryant, J. T., et al.:<\/i> A quantitative approach to radiography of the lower limb. Principles and applications. J. Bone Joint Surg. Br., 1991, <i>73<\/i>(5), 715\u2013720.","DOI":"10.1302\/0301-620X.73B5.1894656"},{"key":"18","doi-asserted-by":"crossref","unstructured":"<i>Thelen, P., Delin, C., Folinais, D., et al.:<\/i> Evaluation of a new low-dose biplanar system to assess lower-limb alignment in 3D: a phantom study. Skeletal Radiol., 2012, <i>41<\/i>(10), 1287\u20131293.","DOI":"10.1007\/s00256-012-1438-x"},{"key":"19","unstructured":"<i>Harrison, M. M., Cooke, T. D., Fisher, S. B., et al.:<\/i> Patterns of knee arthrosis and patellar subluxation. Clin. Orthop. Relat. Res., 1994, <i>309,<\/i> 56\u201363."},{"key":"20","unstructured":"<i>Cooke, T. D., Scudamore, A.:<\/i> Healthy knee alignment and mechanics. In: <i>Callaghan, J. J<\/i>. (ed.): The Adult Knee. Lippincott Williams & Wilkins, Philadelphia, 2003."},{"key":"21","unstructured":"<i>Cooke, T. D., Scudamore, A.:<\/i> Measuring the X-ray: Problems and solutions. Canadian Orthopaedic Bulletin, 2004."},{"key":"22","doi-asserted-by":"crossref","unstructured":"<i>Siu, D., Cooke, T. D., Broekhoven, L. D., et al.:<\/i> A standardized technique for lower limb radiography. Practice, applications, and error analysis. Invest. Radiol., 1991, <i>26<\/i>(1), 71\u201377.","DOI":"10.1097\/00004424-199101000-00013"},{"key":"23","doi-asserted-by":"crossref","unstructured":"<i>Prakash, U., Wigderowitz, C. A., McGurty, D. W., et al.:<\/i> Computerised measurement of tibiofemoral alignment. J. Bone Joint Surg. Br., 2001, <i>83-B<\/i>(6), 819\u2013824.","DOI":"10.1302\/0301-620X.83B6.11349"},{"key":"24","doi-asserted-by":"crossref","unstructured":"<i>Sanfridsson, J., Ryd, L., Svahn, G., et al.:<\/i> Radiographic measurement of femorotibial rotation in weight-bearing. The influence of flexion and extension in the knee on the extensor mechanism and angles of the lower extremity in a healthy population. Acta Radiol., 2001, <i>42<\/i>(2), 207\u2013217.","DOI":"10.1080\/028418501127346512"},{"key":"25","doi-asserted-by":"crossref","unstructured":"<i>Ruwe, P. A., Gage, J. R., Ozonoff, M. B., et al.:<\/i> Clinical determination of femoral anteversion. A comparison with established techniques. J. Bone Joint Surg. Am., 1992, <i>74<\/i>(6), 820\u2013830.","DOI":"10.2106\/00004623-199274060-00003"},{"key":"26","doi-asserted-by":"crossref","unstructured":"<i>Davids, J. R., Davis, R. B.:<\/i> Tibial torsion: significance and measurement. Gait Posture, 2007, <i>26<\/i>(2), 169\u2013171.","DOI":"10.1016\/j.gaitpost.2007.05.002"},{"key":"27","doi-asserted-by":"crossref","unstructured":"<i>Hazlewood, M. E., Simmons, A. N., Johnson, W. T., et al.:<\/i> The footprint method to assess transmalleolar axis. Gait Posture, 2007, <i>25<\/i>(4), 597\u2013603.","DOI":"10.1016\/j.gaitpost.2006.06.011"},{"key":"28","doi-asserted-by":"crossref","unstructured":"<i>Lincoln, T. L., Suen, P. W.:<\/i> Common rotational variations in children. J. Am. Acad. Orthop. Surg., 2003, <i>11<\/i>(5), 312\u2013320.","DOI":"10.5435\/00124635-200309000-00004"},{"key":"29","unstructured":"<i>Staheli, L. T.:<\/i> Rotational problems in children. Instr. Course Lect., 1994, <i>43,<\/i> 199\u2013209."},{"key":"30","doi-asserted-by":"crossref","unstructured":"<i>Lee, S. H., Chung, C. Y., Park, M. S., et al.:<\/i> Tibial torsion in cerebral palsy: validity and reliability of measurement. Clin. Orthop. Relat. Res., 2009, <i>467<\/i>(8), 2098\u20132104.","DOI":"10.1007\/s11999-009-0705-1"},{"key":"31","unstructured":"<i>Charpak, G.:<\/i> Prospects for the use in medicine of new detectors of ionizing radiation. Bull. Acad. Natl. Med., 1996, <i>180<\/i>(1), 161\u2013168. [French]"},{"key":"32","doi-asserted-by":"crossref","unstructured":"<i>Charpak, G., Bouclier, R., Bressani, T., et al.:<\/i> The use of multiwire proportional counters to select and localize charged particles. Nucl. Instrum. Methods, 1968, <i>62<\/i>(3), 262\u2013268.","DOI":"10.1016\/0029-554X(68)90371-6"},{"key":"33","doi-asserted-by":"crossref","unstructured":"<i>Ill\u00e9s, T., Somoske\u00f6y, S.:<\/i> The EOS\u2122 imaging system and its uses in daily orthopaedic practice. Int. Orthop., 2012, <i>36<\/i>(7), 1325\u20131331.","DOI":"10.1007\/s00264-012-1512-y"},{"key":"34","unstructured":"<i>L\u00e9vai, A., Batty\u00e1ny, I., J\u00e1ray, \u00c1., et al.:<\/i> EOS in clinical practice. Methodology, importance, clinical indication and data content of ultra low, whole body digital X-ray imager. [EOS a klinikai gyakorlatban (Ultraalacsony d\u00f3zis\u00fa digit\u00e1lis teljestest-r\u00f6ntgenfelv\u00e9tel technik\u00e1ja, jelent\u0151s\u00e9ge, klinikai indik\u00e1ci\u00f3ja, inform\u00e1ci\u00f3tartalma).] IME, 2008, <i>7<\/i>(3), 41\u201343. [Hungarian]"},{"key":"35","unstructured":"<i>Bertrand, S.:<\/i> Mod\u00e9lisation g\u00e9om\u00e9trique 3D in vivo du tronc humain \u00e0 partir de l\u2019imageur basse dose EOS. Pastel., 2005. <a href=\"http:\/\/pastel.archives-ouvertes.fr\/pastel-00001505\">http:\/\/pastel.archives-ouvertes.fr\/pastel-00001505<\/a> . [French]"},{"key":"36","doi-asserted-by":"crossref","unstructured":"<i>Desch\u00eanes, S., Charron, G., Beaudoin, G., et al.:<\/i> Diagnostic imaging of spinal deformities: reducing patients radiation dose with a new slot-scanning X-ray imager. Spine, 2010, <i>35<\/i>(9), 989\u2013994.","DOI":"10.1097\/BRS.0b013e3181bdcaa4"},{"key":"37","doi-asserted-by":"crossref","unstructured":"<i>Obeid, I., Illes, T.:<\/i> EOS \u2013 a new 2D|3D, low dose musculoskeletal imaging system. Argospine News J., 2009, <i>21<\/i>(3), 122\u2013126.","DOI":"10.1007\/s12240-009-0024-0"},{"key":"38","doi-asserted-by":"crossref","unstructured":"<i>Gheno, R., Nectoux, E., Herbaux, B., et al.:<\/i> Three-dimensional measurements of the lower extremity in children and adolescents using a low-dose biplanar X-ray device. Eur. Radiol., 2012, <i>22<\/i>(4), 765\u2013771.","DOI":"10.1007\/s00330-011-2308-y"},{"key":"39","doi-asserted-by":"crossref","unstructured":"<i>Ohl, X., Stanchina, C., Billuart, F., et al.:<\/i> Shoulder bony landmarks location using the EOS low-dose stereoradiography system: a reproducibility study. Surg. Radiol. Anat., 2010, <i>32<\/i>(2), 153\u2013158.","DOI":"10.1007\/s00276-009-0566-z"},{"key":"40","doi-asserted-by":"crossref","unstructured":"<i>Chaibi, Y., Cresson, T., Aubert, B., et al.:<\/i> Fast 3D reconstruction of the lower limb using a parametric model and statistical inferences and clinical measurements calculation from biplanar X-rays. Comput. Methods Biomech. Biomed. Engin., 2012, <i>15<\/i>(5), 457\u2013466.","DOI":"10.1080\/10255842.2010.540758"},{"key":"41","unstructured":"<i>Winer, B. J.:<\/i> Statistical principles in experimental design. 2nd ed. McGraw Hill, New York, 1971."},{"key":"42","doi-asserted-by":"crossref","unstructured":"<i>Folinais, D., Thelen, P., Delin, C., et al.:<\/i> Measuring femoral and rotational alignment: EOS system versus computed tomography. Orthop. Traumatol. Surg. Res., 2013, <i>99<\/i>(5), 509\u2013516.","DOI":"10.1016\/j.otsr.2012.12.023"},{"key":"43","doi-asserted-by":"crossref","unstructured":"<i>Journ\u00e9, A., Sadaka, J., B\u00e9licourt, C., et al.:<\/i> New method for measuring acetabular component positioning with EOS imaging: feasibility study on dry bone. Int. Orthop., 2012, <i>36<\/i>(11), 2205\u20132209.","DOI":"10.1007\/s00264-012-1650-2"},{"key":"44","doi-asserted-by":"crossref","unstructured":"<i>Guenoun, B., Zadegan, F., Aim, F., et al.:<\/i> Reliability of a new method for lower-extremity measurements based on stereoradiographic three-dimensional reconstruction. Orthop. Traumatol. Surg. Res., 2012, <i>98<\/i>(5), 506\u2013513.","DOI":"10.1016\/j.otsr.2012.03.014"},{"key":"45","unstructured":"<i>Morvan, G., Vuillemin, V., Guerini, H., et al.:<\/i> L\u2019homme debout. Imagerie. Le syst\u00e8me EOS. e-m\u00e9moires de l\u2019Acad\u00e9mie Nationale de Chirurgie, 2013, <i>12<\/i>(2), 6\u201317. [French]"},{"key":"46","doi-asserted-by":"crossref","unstructured":"<i>Azmy, C., Gu\u00e9rard, S., Bonnet, X., et al.:<\/i> EOS<sup>\u00ae<\/sup> orthopaedic imaging system to study patellofemoral kinematics: Assessment of uncertainty. Orthop. Traumatol. Surg. Res., 2010, <i>96<\/i>(1), 28\u201336.","DOI":"10.1016\/j.otsr.2009.10.013"},{"key":"47","doi-asserted-by":"crossref","unstructured":"<i>Lazennec, J. Y., Rangel, A., Baudoin, A., et al.:<\/i> The EOS imaging system for understanding a patellofemoral disorder following THR. Orthop. Traumatol. Surg. Res., 2011, <i>97<\/i>(1), 98\u2013101.","DOI":"10.1016\/j.otsr.2010.07.010"},{"key":"48","doi-asserted-by":"crossref","unstructured":"<i>Piriou, P., Bugyan, H., Casalonga, D., et al.:<\/i> Can hip anatomy be reconstructed with femoral components having only one neck morphology? A study on 466 hips. J. Arthroplasty, 2013, <i>28<\/i>(7), 1185\u20131191.","DOI":"10.1016\/j.arth.2012.08.023"},{"key":"49","doi-asserted-by":"crossref","unstructured":"<i>Boutry, N., Dutouquet, B., Leleu, X., et al.:<\/i> Low-dose biplanar skeletal survey versus digital skeletal survey in multiple myeloma. Eur. Radiol., 2013, <i>23<\/i>(8), 2236\u20132245.","DOI":"10.1007\/s00330-013-2812-3"},{"key":"50","doi-asserted-by":"crossref","unstructured":"<i>Than, P., Szuper, K., Somoske\u00f6y, S., et al.:<\/i> Geometrical values of the normal and arthritic hip and knee detected with the EOS imaging system. Int. Orthop., 2012, <i>36<\/i>(6), 1291\u20131297.","DOI":"10.1007\/s00264-011-1403-7"},{"key":"51","doi-asserted-by":"crossref","unstructured":"<i>Assi, A., Chaibi, Y., Presedo, A., et al.:<\/i> Three-dimensional reconstructions for asymptomatic and cerebral palsy children\u2019s lower limbs using a biplanar X-ray system: A feasibility study. Eur. J. Radiol., 2013, <i>82<\/i>(12), 2359\u20132364.","DOI":"10.1016\/j.ejrad.2013.07.006"},{"key":"52","doi-asserted-by":"crossref","unstructured":"<i>Schmitz, M. R., Bittersohl, B., Zaps, D., et al.:<\/i> Spectrum of radiographic femoroacetabular impingement morphology in adolescents and young adults: an EOS-based double-cohort study. J. Bone Joint Surg. Am., 2013, <i>95<\/i>(13), e90.","DOI":"10.2106\/JBJS.L.01030"},{"key":"53","doi-asserted-by":"crossref","unstructured":"<i>Gaum\u00e9tou, E., Quijano, S., Ilharreborde, B., et al.:<\/i> EOS analysis of lower extremity segmental torsion in children and young adults. Orthop. Traumatol. Surg. Res., 2014, <i>100<\/i>(1), 147\u2013151.","DOI":"10.1016\/j.otsr.2013.09.010"},{"key":"54","unstructured":"<i>Joubert, K., Mag, K., van\u2019t Hof, M., et al.:<\/i> The body height growth\u2019s speed between the ages 3 and 18 years in Hungary around the millennium. [A testmagass\u00e1g n\u00f6veked\u00e9si sebess\u00e9ge 3 \u00e9s 18 \u00e9v k\u00f6z\u00f6tt Magyarorsz\u00e1gon az ezredfordul\u00f3 id\u0151szak\u00e1ban.] Gyermekgy\u00f3gy\u00e1szat, 2006, <i>57<\/i>(5), 517\u2013527. [Hungarian]"}],"container-title":["Orvosi Hetilap"],"original-title":[],"language":"hu","link":[{"URL":"https:\/\/www.akademiai.com\/doi\/pdf\/10.1556\/OH.2014.30009","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,22]],"date-time":"2020-05-22T09:56:12Z","timestamp":1590141372000},"score":1,"resource":{"primary":{"URL":"https:\/\/akjournals.com\/doi\/10.1556\/oh.2014.30009"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,10]]},"references-count":54,"journal-issue":{"issue":"43","published-print":{"date-parts":[[2014,10]]}},"alternative-id":["10.1556\/OH.2014.30009"],"URL":"https:\/\/doi.org\/10.1556\/oh.2014.30009","relation":{},"ISSN":["0030-6002","1788-6120"],"issn-type":[{"value":"0030-6002","type":"print"},{"value":"1788-6120","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,10]]}}}