{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T11:22:30Z","timestamp":1784287350188,"version":"3.55.0"},"reference-count":57,"publisher":"American Academy of Implant Dentistry","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2011,12]]},"abstract":"<jats:p>The aim of this clinical study was to evaluate the prosthodontic maintenance requirements during the first year of service of mandibular overdentures supported by interforaminal implants and to assess the influence of attachment type, implant number, and bite force on these requirements. Fifty-nine patients treated with mandibular implant overdentures between the years 2004 and 2009 and appearing in the 12th-month recall were included in this study. The overdentures constituted 4 groups: 2 single interforaminal implants (1 group with locator and 1 group with ball attachments), 3 single interforaminal implants, 3 splinted interforaminal implants (bar), and 4 splinted interforaminal implants (bar). During the examination, prosthetic parameters such as occlusion, tissue adaptation, condition of the retentive mechanism (matrice and patrice), and the condition of the denture-bearing tissues were evaluated and recorded. No statistically significant relation was found between attachment type, bite force values, implant number, and the occurring complications except the need for relining, which was found significantly more in the ball attachments than in other attachment groups (<jats:italic>P<\/jats:italic> \u200a=\u200a .03). After 12\u00a0months following the overdenture insertion, there seems to be no relation between occurring complications and patient-related factors, such as maximum bite force, age, and gender, as well as factors related to the overdentures such as number and type of attachments.<\/jats:p>","DOI":"10.1563\/aaid-joi-d-10-00096","type":"journal-article","created":{"date-parts":[[2010,10,8]],"date-time":"2010-10-08T10:56:25Z","timestamp":1286535385000},"page":"697-704","source":"Crossref","is-referenced-by-count":30,"title":["Maintenance Requirements Associated With Mandibular Implant Overdentures: Clinical Results After First Year of Service"],"prefix":"10.1563","volume":"37","author":[{"given":"Hakan","family":"Bilhan","sequence":"first","affiliation":[{"name":"Istanbul University, Faculty of Dentistry, Department of Prosthodontics, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Onur","family":"Geckili","sequence":"additional","affiliation":[{"name":"Istanbul University, Faculty of Dentistry, Department of Prosthodontics, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emre","family":"Mumcu","sequence":"additional","affiliation":[{"name":"Istanbul University, Faculty of Dentistry, Department of Prosthodontics, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caglar","family":"Bilmenoglu","sequence":"additional","affiliation":[{"name":"Istanbul University, Faculty of Dentistry, Department of Prosthodontics, Istanbul, Turkey"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"434","reference":[{"key":"i1548-1336-37-6-697-b01","series-title":"Int J Prosthodont","first-page":"536","article-title":"A longitudinal study on mandibular implants supporting an overdenture: the influence of retention mechanism and anatomic-prosthetic variables on peri-implant parameters","volume":"14","author":"Oetterli\n              M,","year":"2001","unstructured":"Oetterli\n              M, \n            \n              Kiener\n              P, \n            \n              Mericske-Stern\n              R. \n          \n          A longitudinal study on mandibular implants supporting an overdenture: the influence of retention mechanism and anatomic-prosthetic variables on peri-implant parameters. Int J Prosthodont. 2001;14:536\u2013542."},{"key":"i1548-1336-37-6-697-b02","series-title":"Int J Prosthodont","first-page":"128","article-title":"In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: comparison of load transfer and denture stability","volume":"16","author":"Tokuhisa\n              M,","year":"2003","unstructured":"Tokuhisa\n              M, \n            \n              Matsushita\n              Y, \n            \n              Koyano\n              K. \n          \n          In vitro study of a mandibular implant overdenture retained with ball, magnet, or bar attachments: comparison of load transfer and denture stability. Int J Prosthodont. 2003;16:128\u2013134."},{"key":"i1548-1336-37-6-697-b03","series-title":"Int J Prosthodont","first-page":"125","article-title":"Implant-supported mandibular overdentures retained with ball or bar attachments: a randomized prospective 5-year study","volume":"13","author":"Gotfredsen\n              K,","year":"2000","unstructured":"Gotfredsen\n              K, \n            \n              Holm\n              B. \n          \n          Implant-supported mandibular overdentures retained with ball or bar attachments: a randomized prospective 5-year study. Int J Prosthodont. 2000;13:125\u2013130."},{"key":"i1548-1336-37-6-697-b04","series-title":"Int J Prosthodont","first-page":"99","article-title":"Patient satisfaction and preference with magnet, bar-clip, and ball-socket retained mandibular implant overdentures: a cross-over clinical trial","volume":"18","author":"Cune\n              M,","year":"2005","unstructured":"Cune\n              M, \n            \n              van Kampen\n              F, \n            \n              van der Bilt\n              A, \n            \n              Bosman\n              F. \n          \n          Patient satisfaction and preference with magnet, bar-clip, and ball-socket retained mandibular implant overdentures: a cross-over clinical trial. Int J Prosthodont. 2005;18:99\u2013105."},{"key":"i1548-1336-37-6-697-b05","series-title":"J Prosthet Dent","first-page":"327","article-title":"Effect of anchorage systems and extension base contact on load transfer with mandibular implant-retained overdentures","volume":"84","author":"Sadowsky\n              SJ,","year":"2000","unstructured":"Sadowsky\n              SJ, \n            \n              Caputo\n              AA. \n          \n          Effect of anchorage systems and extension base contact on load transfer with mandibular implant-retained overdentures. J Prosthet Dent. 2000;84:327\u2013334."},{"key":"i1548-1336-37-6-697-b06","series-title":"J Prosthet Dent","first-page":"96","article-title":"Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible","volume":"68","author":"Meijer\n              HJ,","year":"1992","unstructured":"Meijer\n              HJ, \n            \n              Kuiper\n              JH, \n            \n              Starmans\n              FJ, \n            \n              Bosman. \n          \n          Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible. J Prosthet Dent. 1992;68:96\u2013102."},{"key":"i1548-1336-37-6-697-b07","series-title":"J Oral Rehabil","first-page":"47","article-title":"Location of implants in the interforaminal region of the mandible and the consequences for the design of the superstructure","volume":"21","author":"Meijer\n              HJ,","year":"1994","unstructured":"Meijer\n              HJ, \n            \n              Starmans\n              FJ, \n            \n              Steen\n              WH, \n            \n              Bosman\n              F. \n          \n          Location of implants in the interforaminal region of the mandible and the consequences for the design of the superstructure. J Oral Rehabil. 1994;21:47\u201356."},{"key":"i1548-1336-37-6-697-b08","series-title":"Int J Oral Maxillofac Implants","first-page":"851","article-title":"Mandibular implant-retained overdenture: a clinical trial of two anchorage systems","volume":"13","author":"Menicucci\n              G,","year":"1998","unstructured":"Menicucci\n              G, \n            \n              Lorenzetti\n              M, \n            \n              Pera\n              P, \n            \n              Preti\n              G. \n          \n          Mandibular implant-retained overdenture: a clinical trial of two anchorage systems. Int J Oral Maxillofac Implants. 1998;13:851\u2013856."},{"key":"i1548-1336-37-6-697-b09","series-title":"Int J Oral Maxillofac Implants","first-page":"85","article-title":"Biomaterials and biomechanics in dental implant design","volume":"3","author":"Brunski\n              JB.","year":"1988","unstructured":"Brunski\n              JB. \n          \n          Biomaterials and biomechanics in dental implant design. Int J Oral Maxillofac Implants. 1988;3:85\u201397."},{"key":"i1548-1336-37-6-697-b10","series-title":"J Prosthet Dent","first-page":"559","article-title":"Photoelastic stress patterns produced by implant-retained overdentures","volume":"80","author":"Kenney\n              R,","year":"1998","unstructured":"Kenney\n              R, \n            \n              Richards\n              MW. \n          \n          Photoelastic stress patterns produced by implant-retained overdentures. J Prosthet Dent. 1998;80:559\u2013564."},{"key":"i1548-1336-37-6-697-b11","series-title":"J Oral Rehabil","first-page":"193","article-title":"Stress distributions in maxillary bone surrounding overdenture implants with different overdenture attachments","volume":"32","author":"Chun\n              HJ,","year":"2005","unstructured":"Chun\n              HJ, \n            \n              Park\n              DN, \n            \n              Han\n              CH, \n            \n              Heo\n              SJ, \n            \n              Heo\n              MS, \n            \n              Koak\n              JY. \n          \n          Stress distributions in maxillary bone surrounding overdenture implants with different overdenture attachments. J Oral Rehabil. 2005;32:193\u2013205."},{"key":"i1548-1336-37-6-697-b12","series-title":"J Prosthet Dent","first-page":"283","article-title":"Problems with prostheses on implants: a retrospective study","volume":"71","author":"Walton\n              JN,","year":"1994","unstructured":"Walton\n              JN, \n            \n              MacEntee\n              MI. \n          \n          Problems with prostheses on implants: a retrospective study. J Prosthet Dent. 1994;71:283\u2013288."},{"key":"i1548-1336-37-6-697-b13","series-title":"Clin Implant Dent Relat Res","first-page":"212","article-title":"Retention mechanisms and prosthetic complications of implant-supported mandibular overdentures: long-term results","volume":"4","author":"Dudic\n              A,","year":"2002","unstructured":"Dudic\n              A, \n            \n              Mericske-Stern\n              R. \n          \n          Retention mechanisms and prosthetic complications of implant-supported mandibular overdentures: long-term results. Clin Implant Dent Relat Res. 2002;4:212\u2013219."},{"key":"i1548-1336-37-6-697-b14","series-title":"Int J Prosthodont","first-page":"193","article-title":"Finite element analysis of stress-breaking attachments on maxillary implant-retained overdentures","volume":"20","author":"Tanino\n              F,","year":"2007","unstructured":"Tanino\n              F, \n            \n              Hayakawa\n              I, \n            \n              Hirano\n              S, \n            \n              Minakuchi\n              S. \n          \n          Finite element analysis of stress-breaking attachments on maxillary implant-retained overdentures. Int J Prosthodont. 2007;20:193\u2013198."},{"key":"i1548-1336-37-6-697-b15","series-title":"Clin Implant Dent Relat Res","first-page":"40","article-title":"A finite element analysis of stress distribution in bone tissue surrounding uncoupled or splinted dental implants","volume":"10","author":"Bergkvist\n              G,","year":"2008","unstructured":"Bergkvist\n              G, \n            \n              Simonsson\n              K, \n            \n              Rydberg\n              K, \n            \n              Johansson\n              F, \n            \n              D\u00e9rand\n              T. \n          \n          A finite element analysis of stress distribution in bone tissue surrounding uncoupled or splinted dental implants. Clin Implant Dent Relat Res. 2008;10:40\u201346."},{"key":"i1548-1336-37-6-697-b16","series-title":"J Dent Res","first-page":"630","article-title":"An eight-year follow-up to a randomized clinical trial of participant satisfaction with three types of mandibular implant-retained overdentures","volume":"83","author":"Timmerman\n              R,","year":"2004","unstructured":"Timmerman\n              R, \n            \n              Stoker\n              GT, \n            \n              Wismeijer\n              D, \n            \n              Oosterveld\n              P, \n            \n              Vermeeren\n              JI, \n            \n              van Waas\n              MA. \n          \n          An eight-year follow-up to a randomized clinical trial of participant satisfaction with three types of mandibular implant-retained overdentures. J Dent Res. 2004;83:630\u2013633."},{"key":"i1548-1336-37-6-697-b17","series-title":"J Dent Res","first-page":"276","article-title":"An eight-year follow-up to a randomized clinical trial of aftercare and cost-analysis with three types of mandibular implant-retained overdentures","volume":"86","author":"Stoker\n              GT,","year":"2007","unstructured":"Stoker\n              GT, \n            \n              Wismeijer\n              D, \n            \n              van Waas\n              MA. \n          \n          An eight-year follow-up to a randomized clinical trial of aftercare and cost-analysis with three types of mandibular implant-retained overdentures. J Dent Res. 2007;86:276\u2013280."},{"key":"i1548-1336-37-6-697-b18","series-title":"Clin Oral Implants Res","first-page":"297","article-title":"Clinical andradiological results of patients treated with three treatment modalities for overdentures on implants of the ITI Dental Implant System: a randomized controlled clinical trial","volume":"10","author":"Wismeijer\n              D,","year":"1999","unstructured":"Wismeijer\n              D, \n            \n              van Waas\n              MA, \n            \n              Mulder\n              J, \n            \n              Vermeeren\n              JI, \n            \n              Kalk\n              W. \n          \n          Clinical andradiological results of patients treated with three treatment modalities for overdentures on implants of the ITI Dental Implant System: a randomized controlled clinical trial. Clin Oral Implants Res. 1999;10:297\u2013306."},{"key":"i1548-1336-37-6-697-b19","series-title":"J Prosthet Dent","first-page":"169","article-title":"The influence of mandibular deformation, implant numbers, and loading position on detected forces in abutments supporting fixed implant superstructures","volume":"80","author":"Hobkirk\n              JA,","year":"1998","unstructured":"Hobkirk\n              JA, \n            \n              Havthoulas\n              TK. \n          \n          The influence of mandibular deformation, implant numbers, and loading position on detected forces in abutments supporting fixed implant superstructures. J Prosthet Dent. 1998;80:169\u2013174."},{"key":"i1548-1336-37-6-697-b20","series-title":"Dent Mater","first-page":"296","article-title":"Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis","volume":"23","author":"Zarone\n              F,","year":"2007","unstructured":"Zarone\n              F, \n            \n              Sorrentino\n              R, \n            \n              Traini\n              T, \n            \n              Di lorio\n              D, \n            \n              Caputi\n              S. \n          \n          Fracture resistance of implant-supported screw- versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis. Dent Mater. 2007;23:296\u2013301."},{"key":"i1548-1336-37-6-697-b21","series-title":"Int J Oral Maxillofac Implants","first-page":"259","article-title":"Maxillary overdentures retained by splinted and unsplinted implants: a retrospective study","volume":"16","author":"N\u00e4rhi\n              TO,","year":"2001","unstructured":"N\u00e4rhi\n              TO, \n            \n              Hevinga\n              M, \n            \n              Voorsmit\n              RA, \n            \n              Kalk\n              W. \n          \n          Maxillary overdentures retained by splinted and unsplinted implants: a retrospective study. Int J Oral Maxillofac Implants. 2001;16:259\u2013266."},{"key":"i1548-1336-37-6-697-b22","series-title":"Int J Prosthodont","first-page":"133","article-title":"Effectiveness of maxillary overdentures supported by implants: maintenance and prosthetic complications","volume":"14","author":"Kiener\n              P,","year":"2001","unstructured":"Kiener\n              P, \n            \n              Oetterli\n              M, \n            \n              Mericske\n              E, \n            \n              Mericske-Stern\n              R. \n          \n          Effectiveness of maxillary overdentures supported by implants: maintenance and prosthetic complications. Int J Prosthodont. 2001;14:133\u2013140."},{"key":"i1548-1336-37-6-697-b23","series-title":"Int J Oral Maxillofac Implants","first-page":"253","article-title":"Implant-supported overdentures: a longitudinal prospective study","volume":"13","author":"Bergendal\n              T,","year":"1998","unstructured":"Bergendal\n              T, \n            \n              Engquist\n              B. \n          \n          Implant-supported overdentures: a longitudinal prospective study. Int J Oral Maxillofac Implants. 1998;13:253\u2013262."},{"key":"i1548-1336-37-6-697-b24","series-title":"Br Dent J","first-page":"469","article-title":"Two implants for all edentulous mandibles","volume":"200","author":"Wright\n              PS.","year":"2006","unstructured":"Wright\n              PS. \n          \n          Two implants for all edentulous mandibles. Br Dent J. 2006;200:469."},{"key":"i1548-1336-37-6-697-b25","series-title":"J Prosthet Dent","first-page":"53","article-title":"The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto Study. Part 11: the prosthetic results","volume":"1","author":"Zarb\n              GA,","year":"1990","unstructured":"Zarb\n              GA, \n            \n              Schniitt\n              A. \n          \n          The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto Study. Part 11: the prosthetic results. J Prosthet Dent. 1990;1:53\u201361."},{"key":"i1548-1336-37-6-697-b26","series-title":"J Prosthet Dent","first-page":"671","article-title":"Prosthetic aspects of osseointegrated fixtures supporting overdentures: a 4-year report","volume":"5","author":"Naert\n              I,","year":"1991","unstructured":"Naert\n              I, \n            \n              Quirynen\n              M, \n            \n              Theuniers\n              G, \n            \n              van Steenberghe\n              D. \n          \n          Prosthetic aspects of osseointegrated fixtures supporting overdentures: a 4-year report. J Prosthet Dent. 1991;5:671\u2013680."},{"key":"i1548-1336-37-6-697-b27","series-title":"Int J Prosthodont","first-page":"89","article-title":"Complications, supplementary treatment, and maintenance in edentulous arches with implant-supported fixed prostheses","volume":"1","author":"Johansson\n              G,","year":"1990","unstructured":"Johansson\n              G, \n            \n              Palmqvist\n              S. \n          \n          Complications, supplementary treatment, and maintenance in edentulous arches with implant-supported fixed prostheses. Int J Prosthodont. 1990;1:89\u201392."},{"key":"i1548-1336-37-6-697-b28","series-title":"Int J Oral Maxillofac Implants","first-page":"270","article-title":"Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup","volume":"3","author":"Jemt\n              T.","year":"1991","unstructured":"Jemt\n              T. \n          \n          Failures and complications in 391 consecutively inserted fixed prostheses supported by Branemark implants in edentulous jaws: a study of treatment from the time of prosthesis placement to the first annual checkup. Int J Oral Maxillofac Implants. 1991;3:270\u2013276."},{"key":"i1548-1336-37-6-697-b29","series-title":"Int J Oral Maxillofac Implants","first-page":"513","article-title":"A multicenter study of overdentures supported by Branemark implants","volume":"7","author":"Johns\n              RB,","year":"1992","unstructured":"Johns\n              RB, \n            \n              Jemt\n              T, \n            \n              Heath\n              MR, \n            et al. \n          A multicenter study of overdentures supported by Branemark implants. Int J Oral Maxillofac Implants. 1992;7:513\u2013522."},{"key":"i1548-1336-37-6-697-b30","series-title":"Br Dent J","first-page":"298","article-title":"Complications and maintenance requirements of implant-supported prostheses provided in a UK dental hospital","volume":"182","author":"Allen\n              PF,","year":"1997","unstructured":"Allen\n              PF, \n            \n              McMillan\n              AS, \n            \n              Smith\n              DC. \n          \n          Complications and maintenance requirements of implant-supported prostheses provided in a UK dental hospital. Br Dent J. 1997;182:298\u2013302."},{"key":"i1548-1336-37-6-697-b31","series-title":"Int J Oral Maxillofac Implants","first-page":"191","article-title":"Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: a 5-year report","volume":"9","author":"Hemmings\n              KW,","year":"1994","unstructured":"Hemmings\n              KW, \n            \n              Schmitt\n              A, \n            \n              Zarb\n              GA. \n          \n          Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: a 5-year report. Int J Oral Maxillofac Implants. 1994;9:191\u2013196."},{"key":"i1548-1336-37-6-697-b32","series-title":"Int J Oral Maxillofac Implants","first-page":"162","article-title":"Failures and complications in 92 consecutively inserted overdentures supported by Br\u00e5nemark implants in severely resorbed edentulous maxillae: a study from prosthetic treatment to first annual check-up","volume":"7","author":"Jemt\n              T,","year":"1992","unstructured":"Jemt\n              T, \n            \n              Book\n              K, \n            \n              Lind\u00e9n\n              B, \n            \n              Urde\n              G. \n          \n          Failures and complications in 92 consecutively inserted overdentures supported by Br\u00e5nemark implants in severely resorbed edentulous maxillae: a study from prosthetic treatment to first annual check-up. Int J Oral Maxillofac Implants. 1992;7:162\u2013167."},{"key":"i1548-1336-37-6-697-b33","series-title":"Clin Oral Implants Res","first-page":"39","article-title":"A clinical and radiological two-year follow-up study of maxillary overdentures on osseointegrated implants","volume":"4","author":"Smedberg\n              JI,","year":"1993","unstructured":"Smedberg\n              JI, \n            \n              Lothigius\n              F, \n            \n              Bodin\n              I, \n            \n              Frykholm\n              A, \n            \n              Nilner\n              K. \n          \n          A clinical and radiological two-year follow-up study of maxillary overdentures on osseointegrated implants. Clin Oral Implants Res. 1993;4:39\u201346."},{"key":"i1548-1336-37-6-697-b34","series-title":"J Prosthet Dent","first-page":"486","article-title":"A comparative prospective study of splinted and unsplinted Branemark implants in mandibular overdenture therapy: a preliminary report","volume":"5","author":"Naert\n              I,","year":"1994","unstructured":"Naert\n              I, \n            \n              Quirynen\n              M, \n            \n              Hooghe\n              M, \n            \n              van Steenberghe\n              D. \n          \n          A comparative prospective study of splinted and unsplinted Branemark implants in mandibular overdenture therapy: a preliminary report. J Prosthet Dent. 1994;5:486\u2013492."},{"key":"i1548-1336-37-6-697-b35","series-title":"Int J Oral Maxillofac Implants","first-page":"744","article-title":"Overdentures supported by ITI implants: a 6.5-year evaluation of patient satisfaction and prosthetic aftercare","volume":"10","author":"Wismeyer\n              D,","year":"1995","unstructured":"Wismeyer\n              D, \n            \n              van Waas\n              MA, \n            \n              Vermeeren\n              JI. \n          \n          Overdentures supported by ITI implants: a 6.5-year evaluation of patient satisfaction and prosthetic aftercare. Int J Oral Maxillofac Implants. 1995;10:744\u2013749."},{"key":"i1548-1336-37-6-697-b36","series-title":"Int J Oral Maxillofac Implants","first-page":"375","article-title":"Clinical evaluation of overdenture restorations supported by osseointegrated titanium implants: a retrospective study","volume":"5","author":"Mericske-Stern\n              R.","year":"1990","unstructured":"Mericske-Stern\n              R. \n          \n          Clinical evaluation of overdenture restorations supported by osseointegrated titanium implants: a retrospective study. Int J Oral Maxillofac Implants. 1990;5:375\u2013383."},{"key":"i1548-1336-37-6-697-b37","series-title":"Int J Oral Maxillofac Implants","first-page":"646","article-title":"Treatment of edentulism using Astra Tech implants and ball abutments to retain mandibular overdentures","volume":"14","author":"Cooper\n              LF,","year":"1999","unstructured":"Cooper\n              LF, \n            \n              Scurria\n              MS, \n            \n              Lang\n              LA, \n            \n              Guckes\n              AD, \n            \n              Moriarty\n              JD, \n            \n              Felton\n              DA. \n          \n          Treatment of edentulism using Astra Tech implants and ball abutments to retain mandibular overdentures. Int J Oral Maxillofac Implants. 1999;14:646\u2013653."},{"key":"i1548-1336-37-6-697-b38","series-title":"Clin Oral Implants Res","first-page":"441","article-title":"A controlled clinical trial of implant-retained mandibular overdentures: five-years' results of clinical aspects and aftercare of IMZ implants and Branemark implants","volume":"11","author":"Meijer\n              HJ,","year":"2000","unstructured":"Meijer\n              HJ, \n            \n              Raghoebar\n              GM, \n            \n              Van't Hof\n              MA, \n            \n              Visser\n              A, \n            \n              Geertman\n              ME, \n            \n              Van Oort\n              RP. \n          \n          A controlled clinical trial of implant-retained mandibular overdentures: five-years' results of clinical aspects and aftercare of IMZ implants and Branemark implants. Clin Oral Implants Res. 2000;11:441\u2013447."},{"key":"i1548-1336-37-6-697-b39","series-title":"Int J Oral Maxillofac Implants","first-page":"767","article-title":"The extent of maintenance required by implant-retained mandibular overdentures: a 3-year report","volume":"11","author":"Davis\n              DM,","year":"1996","unstructured":"Davis\n              DM, \n            \n              Rogers\n              JO, \n            \n              Packer\n              ME. \n          \n          The extent of maintenance required by implant-retained mandibular overdentures: a 3-year report. Int J Oral Maxillofac Implants. 1996;11:767\u2013774."},{"key":"i1548-1336-37-6-697-b40","series-title":"Implant Dent","first-page":"24","article-title":"Attachment systems for implant retained overdentures: a literature review","volume":"15","author":"Trakas\n              T,","year":"2006","unstructured":"Trakas\n              T, \n            \n              Michalakis\n              K, \n            \n              Kang\n              K, \n            \n              Hirayama\n              H. \n          \n          Attachment systems for implant retained overdentures: a literature review. Implant Dent. 2006;15:24\u201334."},{"key":"i1548-1336-37-6-697-b41","series-title":"Implant Dent","first-page":"74","article-title":"A clinical comparison of prosthetic complications of implant-supported overdentures with different attachment systems","volume":"17","author":"Karabuda\n              C,","year":"2008","unstructured":"Karabuda\n              C, \n            \n              Yaltirik\n              M, \n            \n              Bayraktar\n              M. \n          \n          A clinical comparison of prosthetic complications of implant-supported overdentures with different attachment systems. Implant Dent. 2008;17:74\u201381."},{"key":"i1548-1336-37-6-697-b42","series-title":"Int J Oral Maxillofac Implants","first-page":"695","article-title":"A 10-year randomized clinical trial on the influence of splinted and unsplinted oral implants retaining mandibular overdentures: peri-implant outcome","volume":"19","author":"Naert\n              I,","year":"2004","unstructured":"Naert\n              I, \n            \n              Alsaadi\n              G, \n            \n              van Steenberghe\n              D, \n            \n              Quirynen\n              M. \n          \n          A 10-year randomized clinical trial on the influence of splinted and unsplinted oral implants retaining mandibular overdentures: peri-implant outcome. Int J Oral Maxillofac Implants. 2004;19:695\u2013702."},{"key":"i1548-1336-37-6-697-b43","series-title":"Clin Oral Implants Res","first-page":"720","article-title":"Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3\u00a0months of function","volume":"14","author":"van Kampen\n              F,","year":"2003","unstructured":"van Kampen\n              F, \n            \n              Cune\n              M, \n            \n              van der Bilt\n              A, \n            \n              Bosman\n              F. \n          \n          Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3\u00a0months of function. Clin Oral Implants Res. 2003;14:720\u2013726."},{"key":"i1548-1336-37-6-697-b44","series-title":"Int J Prosthodont","first-page":"255","article-title":"A randomized clinical trial comparing two mandibular implant overdenture designs: 3-year prosthetic outcomes using a six-field protocol","volume":"16","author":"Walton\n              JN.","year":"2003","unstructured":"Walton\n              JN. \n          \n          A randomized clinical trial comparing two mandibular implant overdenture designs: 3-year prosthetic outcomes using a six-field protocol. Int J Prosthodont. 2003;16:255\u2013260."},{"key":"i1548-1336-37-6-697-b45","series-title":"Int J Oral Maxillofac Implants","first-page":"163","article-title":"Systematic review of prosthetic maintenance requirements for implant-supported overdentures","volume":"25","author":"Cehreli\n              MC,","year":"2010","unstructured":"Cehreli\n              MC, \n            \n              Karasoy\n              D, \n            \n              Kokat\n              AM, \n            \n              Akca\n              K, \n            \n              Eckert\n              SE. \n          \n          Systematic review of prosthetic maintenance requirements for implant-supported overdentures. Int J Oral Maxillofac Implants. 2010;25:163\u2013180."},{"key":"i1548-1336-37-6-697-b46","series-title":"Int J Oral Maxillofac Implants","first-page":"251","article-title":"Implant and prosthetic treatment of the edentulous maxilla using a bar-supported prosthesis","volume":"7","author":"Kramer\n              A,","year":"1992","unstructured":"Kramer\n              A, \n            \n              Weber\n              H, \n            \n              Benzing\n              U. \n          \n          Implant and prosthetic treatment of the edentulous maxilla using a bar-supported prosthesis. Int J Oral Maxillofac Implants. 1992;7:251\u2013255."},{"key":"i1548-1336-37-6-697-b47","series-title":"Int J Oral Maxillofac Implants","first-page":"188","article-title":"Biomechanical aspects of 2 different implant prosthetic concepts for the edentulous maxilla","volume":"10","author":"Benzing\n              UR,","year":"1995","unstructured":"Benzing\n              UR, \n            \n              Gall\n              H, \n            \n              Weber\n              H. \n          \n          Biomechanical aspects of 2 different implant prosthetic concepts for the edentulous maxilla. Int J Oral Maxillofac Implants. 1995;10:188\u2013198."},{"key":"i1548-1336-37-6-697-b48","series-title":"J Oral Maxillofac Implants","first-page":"107","article-title":"Complete dentures fixed on dental implants: chewing patterns and implant stress","volume":"4","author":"Setz\n              J,","year":"1989","unstructured":"Setz\n              J, \n            \n              Kr\u00e4mer\n              A, \n            \n              Benzing\n              U, \n            et al. \n          Complete dentures fixed on dental implants: chewing patterns and implant stress. J Oral Maxillofac Implants. 1989;4:107\u2013111."},{"key":"i1548-1336-37-6-697-b49","series-title":"Clin Oral Implants Res","first-page":"387","article-title":"3-D in vivo force measurements on mandibular implants supporting overdentures: a comparative study","volume":"7","author":"Mericske-Stern\n              R,","year":"1996","unstructured":"Mericske-Stern\n              R, \n            \n              Piotti\n              M, \n            \n              Sirtes\n              G. \n          \n          3-D in vivo force measurements on mandibular implants supporting overdentures: a comparative study. Clin Oral Implants Res. 1996;7:387\u2013396."},{"key":"i1548-1336-37-6-697-b50","series-title":"J Oral Rehabil","first-page":"482","article-title":"Stress distribution of abutments and base displacement with precision attachment- and telescopic crown-retained removable partial dentures","volume":"30","author":"Saito\n              M,","year":"2003","unstructured":"Saito\n              M, \n            \n              Miura\n              Y, \n            \n              Notani\n              K, \n            \n              Kawasaki\n              T. \n          \n          Stress distribution of abutments and base displacement with precision attachment- and telescopic crown-retained removable partial dentures. J Oral Rehabil. 2003;30:482\u2013487."},{"key":"i1548-1336-37-6-697-b51","series-title":"Quintessence Int","first-page":"621","article-title":"Removable partial denture production in Western Germany","volume":"26","author":"\u00d6wall\n              B,","year":"1995","unstructured":"\u00d6wall\n              B, \n            \n              Bieniek\n              K. W, \n            \n              Spiekermann\n              H. \n          \n          Removable partial denture production in Western Germany. Quintessence Int. 1995;26:621\u2013627."},{"key":"i1548-1336-37-6-697-b52","series-title":"J Oral Maxillofac Implants","first-page":"548","article-title":"A comparative evaluation of some outcome measures of implant systems and suprastructures types in mandibular implant overdenture treatment","volume":"9","author":"Cune\n              MS,","year":"1994","unstructured":"Cune\n              MS, \n            \n              de Putter\n              C. \n          \n          A comparative evaluation of some outcome measures of implant systems and suprastructures types in mandibular implant overdenture treatment. J Oral Maxillofac Implants. 1994;9:548\u2013555."},{"key":"i1548-1336-37-6-697-b53","series-title":"J Prosthet Dent","first-page":"37","article-title":"Telescope retainers for removable partial dentures","volume":"45","author":"Langer\n              A.","year":"1981","unstructured":"Langer\n              A. \n          \n          Telescope retainers for removable partial dentures. J Prosthet Dent. 1981;45:37\u201343."},{"key":"i1548-1336-37-6-697-b54","series-title":"J Can Dent Assoc","first-page":"691","article-title":"Locator attachments as an alternative to ball attachments in 2-implant retained mandibular overdentures","volume":"73","author":"Geckili\n              O,","year":"2007","unstructured":"Geckili\n              O, \n            \n              Bilhan\n              H, \n            \n              Bilgin\n              T. \n          \n          Locator attachments as an alternative to ball attachments in 2-implant retained mandibular overdentures. J Can Dent Assoc. 2007;73:691\u2013694."},{"key":"i1548-1336-37-6-697-b55","series-title":"J Oral Rehabil","first-page":"80","article-title":"Is there a certain number of implants needed to retain an overdenture","volume":"35","author":"Klemetti\n              E.","year":"2008","unstructured":"Klemetti\n              E. \n          \n          Is there a certain number of implants needed to retain an overdenture? J Oral Rehabil. 2008;35:80\u201384."},{"key":"i1548-1336-37-6-697-b56","series-title":"Int J Prosthodont","first-page":"13","article-title":"The immediately loaded single implant-retained mandibular overdenture: a 36-month prospective study","volume":"23","author":"Liddelow\n              G,","year":"2010","unstructured":"Liddelow\n              G, \n            \n              Henry\n              P. \n          \n          The immediately loaded single implant-retained mandibular overdenture: a 36-month prospective study. Int J Prosthodont. 2010;23:13\u201321."},{"key":"i1548-1336-37-6-697-b57","series-title":"J Prosthet Dent","first-page":"159","article-title":"Mandibular overdentures anchored to single implants: a five-year prospective study","volume":"78","author":"Cordioli\n              G,","year":"1997","unstructured":"Cordioli\n              G, \n            \n              Majzoub\n              Z, \n            \n              Castagna\n              S. \n          \n          Mandibular overdentures anchored to single implants: a five-year prospective study. J Prosthet Dent. 1997;78:159\u2013165."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/37\/6\/article-p697.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/meridian.allenpress.com\/joi\/article-pdf\/37\/6\/697\/2038731\/aaid-joi-d-10-00096.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/37\/6\/article-p697.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/37\/6\/article-p697.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T00:06:12Z","timestamp":1752192372000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/37\/6\/article-p697.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,12]]},"references-count":57,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-10-00096","relation":{},"ISSN":["0160-6972","1548-1336"],"issn-type":[{"value":"0160-6972","type":"print"},{"value":"1548-1336","type":"electronic"}],"subject":[],"published":{"date-parts":[[2011,12]]}}}