{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,31]],"date-time":"2026-01-31T09:08:57Z","timestamp":1769850537636,"version":"3.49.0"},"reference-count":23,"publisher":"American Academy of Implant Dentistry","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2014,2]]},"abstract":"<jats:p>The present study compared the use of cone beam computerized tomography (CBCT) images and intra-oral radiographs in the placement of final implant drills in terms of nerve damage to cadaver mandibles. Twelve cadaver hemimandibles obtained from 6 cadavers were used. Right hemimandibles were imaged using peri-apical radiography and left hemimandibles using CBCT, and the images obtained were used in treatment planning for the placement of implant drills (22 for each modality, for a total of 44 final drills). Specimens were dissected, and the distances between the apex of the final implant drill and the inferior alveolar neurovascular bundle and incisive nerve were measured using a digital calliper. Nerves were assessed as damaged or not damaged, and the Chi-square test was used to compare nerve damage between modalities (<jats:italic>P<\/jats:italic> &lt; 0.05). Nerve damage occurred with 7 final drills placed based on peri-apical radiography (31.8%) and 1 final drill placed using CBCT images (4.5%). The difference in nerve damage between imaging modalities was statistically significant (<jats:italic>P<\/jats:italic> = 0.023), with CBCT outperforming intraoral film in the placement of final implant drills ex vivo. In order to prevent nerve damage, CBCT is recommended as the principal imaging modality for pre-implant assessment.<\/jats:p>","DOI":"10.1563\/aaid-joi-d-11-00191","type":"journal-article","created":{"date-parts":[[2011,12,8]],"date-time":"2011-12-08T15:23:27Z","timestamp":1323357807000},"page":"76-82","source":"Crossref","is-referenced-by-count":11,"title":["Nerve Damage Assessment Following Implant Placement in Human Cadaver Jaws: An Ex Vivo Comparative Study"],"prefix":"10.1563","volume":"40","author":[{"given":"Sema","family":"Murat","sequence":"first","affiliation":[{"name":"Ankara University, Faculty of Dentistry, Department of Prosthodontics, Ankara, Turkey."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K\u0131van\u00e7","family":"Kamburo\u011flu","sequence":"additional","affiliation":[{"name":"Ankara University, Faculty of Dentistry, Department of Dentomaxillofacial Radiology, Ankara, Turkey."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cenk","family":"K\u0131l\u0131\u00e7","sequence":"additional","affiliation":[{"name":"G\u00fclhane Military Medical Academy, Faculty of Medicine, Department of Anatomy, Ankara, Turkey."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tuncer","family":"Ozen","sequence":"additional","affiliation":[{"name":"G\u00fclhane Military Medical Academy, Dental Science Centre, Department of Dentomaxillofacial Radiology, Ankara, Turkey."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ayhan","family":"Gurbuz","sequence":"additional","affiliation":[{"name":"Ankara University, Faculty of Dentistry, Department of Prosthodontics, Ankara, Turkey."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"434","reference":[{"key":"i1548-1336-40-1-76-b01","series-title":"J Oral Maxillofac Surg","first-page":"2288","article-title":"Branching patterns and intraosseous course of the mental nerve","volume":"65","author":"Hu\n              KS,","year":"2007","unstructured":"Hu\n              KS, \n            \n              Yun\n              HS, \n            \n              Hur\n              MS, \n            \n              Kwon\n              HJ, \n            \n              Abe\n              S, \n            \n              Kim\n              HJ. \n          \n          Branching patterns and intraosseous course of the mental nerve. J Oral Maxillofac Surg. 2007;65:2288\u20132294."},{"key":"i1548-1336-40-1-76-b02","series-title":"Clin Anat","first-page":"34","article-title":"The position of the mandibular canal and histologic feature of the inferior alveolar nerve","volume":"23","author":"Kilic\n              C,","year":"2010","unstructured":"Kilic\n              C, \n            \n              Kamburo\u011flu\n              K, \n            \n              Ozen\n              T, \n            et al\n          . The position of the mandibular canal and histologic feature of the inferior alveolar nerve. Clin Anat. 2010;23:34\u201342."},{"key":"i1548-1336-40-1-76-b03","series-title":"J Oral Maxillofac Surg","first-page":"744","article-title":"Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography","volume":"67","author":"Uchida\n              Y,","year":"2009","unstructured":"Uchida\n              Y, \n            \n              Noguchi\n              N, \n            \n              Goto\n              M, \n            et al\n          . Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography. J Oral Maxillofac Surg. 2009;67:744\u2013750."},{"key":"i1548-1336-40-1-76-b04","series-title":"Int J Oral Implantol","first-page":"37","article-title":"Predictable mandibular nerve location: a clinical zone of safety","volume":"7","author":"Misch\n              CE,","year":"1990","unstructured":"Misch\n              CE, \n            \n              Crawford\n              EA. \n          \n          Predictable mandibular nerve location: a clinical zone of safety. Int J Oral Implantol. 1990;7:37\u201340."},{"key":"i1548-1336-40-1-76-b05","series-title":"Clin Oral Investig","first-page":"375","article-title":"Calibration of radiographs by a reference metal ball affects preoperative selection of implant size","volume":"13","author":"Schropp\n              L,","year":"2009","unstructured":"Schropp\n              L, \n            \n              Stavropoulos\n              A, \n            \n              Gotfredsen\n              E, \n            \n              Wenzel\n              A. \n          \n          Calibration of radiographs by a reference metal ball affects preoperative selection of implant size. Clin Oral Investig. 2009;13:375\u2013381."},{"issue":"Suppl 1","key":"i1548-1336-40-1-76-b06","series-title":"Aust Dent J","first-page":"S3","article-title":"Patient assessment and diagnosis in implant treatment","volume":"53","author":"Zitzmann\n              NU,","year":"2008","unstructured":"Zitzmann\n              NU, \n            \n              Margolin\n              MD, \n            \n              Filippi\n              A, \n            \n              Weiger\n              R, \n            \n              Krastl\n              G. \n          \n          Patient assessment and diagnosis in implant treatment. Aust Dent J. 2008;53Suppl 1:S3\u2013S10."},{"key":"i1548-1336-40-1-76-b07","series-title":"J Digit Imaging","first-page":"787","article-title":"Accuracy of CBCT measurements of a human skull","volume":"24","author":"Kamburo\u011flu\n              K,","year":"2011","unstructured":"Kamburo\u011flu\n              K, \n            \n              Kolsuz\n              E, \n            \n              Kurt\n              H, \n            \n              K\u0131l\u0131\u00e7\n              C, \n            \n              Ozen\n              T, \n            \n              Paksoy\n              C. \n          \n          Accuracy of CBCT measurements of a human skull. J Digit Imaging. 2011;24:787\u2013293."},{"key":"i1548-1336-40-1-76-b08","series-title":"Dent Clin North Am","first-page":"707","article-title":"What is cone-beam CT and how does it work?","volume":"52","author":"Scarfe\n              WC,","year":"2008","unstructured":"Scarfe\n              WC, \n            \n              Farman\n              AG. \n          \n          What is cone-beam CT and how does it work?\n          Dent Clin North Am. 2008;52:707\u2013730."},{"key":"i1548-1336-40-1-76-b09","series-title":"IEEE Trans Med Imaging","first-page":"842","article-title":"An image-guided planning system for endosseous oral implants","volume":"17","author":"Verstreken\n              K,","year":"1998","unstructured":"Verstreken\n              K, \n            \n              Van Cleynenbreugel\n              J, \n            \n              Martens\n              K, \n            \n              Marchal\n              G, \n            \n              van Steenberghe\n              D, \n            \n              Suetens\n              P. \n          \n          An image-guided planning system for endosseous oral implants. IEEE Trans Med Imaging. 1998;17:842\u2013852."},{"key":"i1548-1336-40-1-76-b10","series-title":"J Oral Maxillofac Surg","first-page":"1408","article-title":"The incidence of altered sensation of the mental nerve after mandibular implant placement","volume":"57","author":"Bartling\n              R,","year":"1999","unstructured":"Bartling\n              R, \n            \n              Freeman\n              K, \n            \n              Kraut\n              RA. \n          \n          The incidence of altered sensation of the mental nerve after mandibular implant placement. J Oral Maxillofac Surg. 1999;57:1408\u20131412."},{"key":"i1548-1336-40-1-76-b11","series-title":"J Endod","first-page":"161","article-title":"Anatomical relationship of the mandibular canal to its surrounding structures in mature mandibles","volume":"18","author":"Denio\n              D,","year":"1992","unstructured":"Denio\n              D, \n            \n              Torabinejad\n              M, \n            \n              Bakland\n              LK. \n          \n          Anatomical relationship of the mandibular canal to its surrounding structures in mature mandibles. J Endod. 1992;18:161\u2013165."},{"issue":"Suppl 3","key":"i1548-1336-40-1-76-b12","series-title":"J Am Dent Assoc","first-page":"19","article-title":"The role of cone-beam computed tomography in the planning and placement of implants","volume":"141","author":"Worthington\n              P,","year":"2010","unstructured":"Worthington\n              P, \n            \n              Rubenstein\n              J, \n            \n              Hatcher\n              DC. \n          \n          The role of cone-beam computed tomography in the planning and placement of implants. J Am Dent Assoc. 2010;141(Suppl 3):19\u201324."},{"key":"i1548-1336-40-1-76-b13","series-title":"J Periodontol","first-page":"395","article-title":"Risk assessment before extraction for immediate implant placement in the posterior mandible: a computerized tomographic scan study","volume":"82","author":"Froum\n              S,","year":"2011","unstructured":"Froum\n              S, \n            \n              Casanova\n              L, \n            \n              Byrne\n              S, \n            \n              Cho\n              SC. \n          \n          Risk assessment before extraction for immediate implant placement in the posterior mandible: a computerized tomographic scan study. J Periodontol. 2011;82:395\u2013402."},{"key":"i1548-1336-40-1-76-b14","series-title":"Int J Oral Maxillofac Implants","first-page":"455","article-title":"A comparison of the accuracy of periapical, panoramic, and computerized tomographic radiographs in locating the mandibular canal","volume":"9","author":"Sonick\n              M,","year":"1994","unstructured":"Sonick\n              M, \n            \n              Abrahams\n              J, \n            \n              Faiella\n              RA. \n          \n          A comparison of the accuracy of periapical, panoramic, and computerized tomographic radiographs in locating the mandibular canal. Int J Oral Maxillofac Implants. 1994;9:455\u2013460."},{"key":"i1548-1336-40-1-76-b15","series-title":"Int J Oral Maxillofac Implants","first-page":"674","article-title":"The prevalence of altered sensation associated with implant surgery","volume":"8","author":"Ellies\n              LG,","year":"1993","unstructured":"Ellies\n              LG, \n            \n              Hawker\n              PB. \n          \n          The prevalence of altered sensation associated with implant surgery. Int J Oral Maxillofac Implants. 1993;8:674\u2013679."},{"key":"i1548-1336-40-1-76-b16","series-title":"J Prosthet Dent","first-page":"443","article-title":"Altered sensation associated with implants in the anterior mandible: a prospective study","volume":"83","author":"Walton\n              JN.","year":"2000","unstructured":"Walton\n              JN. \n          \n          Altered sensation associated with implants in the anterior mandible: a prospective study. J Prosthet Dent. 2000;83:443\u2013449."},{"key":"i1548-1336-40-1-76-b17","series-title":"J Prosthet Dent","first-page":"185","article-title":"The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: problems and complications encountered","volume":"64","author":"Zarb\n              GA,","year":"1990","unstructured":"Zarb\n              GA, \n            \n              Schmitt\n              A. \n          \n          The longitudinal clinical effectiveness of osseointegrated dental implants: the Toronto study. Part III: problems and complications encountered. J Prosthet Dent. 1990;64:185\u2013194."},{"key":"i1548-1336-40-1-76-b18","series-title":"J Oral Implantol","first-page":"401","article-title":"Inferior alveolar nerve injury in implant dentistry: diagnosis, causes, prevention, and management","volume":"36","author":"Alhassani\n              AA,","year":"2010","unstructured":"Alhassani\n              AA, \n            \n              AlGhamdi\n              AS. \n          \n          Inferior alveolar nerve injury in implant dentistry: diagnosis, causes, prevention, and management. J Oral Implantol. 2010;36:401\u2013407."},{"key":"i1548-1336-40-1-76-b19","series-title":"J Oral Maxillofac Res","first-page":"e1","article-title":"Injury of the inferior alveolar nerve during implant placement: a literature review","volume":"2","author":"Juodzbalys\n              G,","year":"2011","unstructured":"Juodzbalys\n              G, \n            \n              Wang\n              HL, \n            \n              Sabalys\n              G. \n          \n          Injury of the inferior alveolar nerve during implant placement: a literature review. J Oral Maxillofac Res. 2011;2:e1\u2013e20."},{"key":"i1548-1336-40-1-76-b20","series-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod","first-page":"e34","article-title":"Measurements of mandibular canal region obtained by cone-beam computed tomography: a cadaveric study","volume":"107","author":"Kamburo\u011flu\n              K,","year":"2009","unstructured":"Kamburo\u011flu\n              K, \n            \n              Kili\u00e7\n              C, \n            \n              Ozen\n              T, \n            \n              Y\u00fcksel\n              SP. \n          \n          Measurements of mandibular canal region obtained by cone-beam computed tomography: a cadaveric study. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009;107:e34\u2013e42."},{"key":"i1548-1336-40-1-76-b21","series-title":"J Periodontol","first-page":"1735","article-title":"Analysis of the occlusal stress transmitted to the inferior alveolar nerve by an osseointegrated threaded fixture","volume":"79","author":"Sammartino\n              G,","year":"2008","unstructured":"Sammartino\n              G, \n            \n              Marenzi\n              G, \n            \n              Citarella\n              R, \n            \n              Ciccarelli\n              R, \n            \n              Wang\n              HL. \n          \n          Analysis of the occlusal stress transmitted to the inferior alveolar nerve by an osseointegrated threaded fixture. J Periodontol. 2008;79:1735\u20131744."},{"key":"i1548-1336-40-1-76-b22","series-title":"Dentomaxillofac Radiol","first-page":"268","article-title":"Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different field of views","volume":"37","author":"Hirsch\n              E,","year":"2008","unstructured":"Hirsch\n              E, \n            \n              Wolf\n              U, \n            \n              Heinicke\n              F, \n            \n              Silva\n              MA. \n          \n          Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different field of views. Dentomaxillofac Radiol. 2008;37:268\u2013273."},{"key":"i1548-1336-40-1-76-b23","series-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod","first-page":"571","article-title":"Effective dosages for recording Veraviewepocs dental panoramic images: analog film, digital, and panoramic scout for CBCT","volume":"106","author":"Garcia Silva\n              MA,","year":"2008","unstructured":"Garcia Silva\n              MA, \n            \n              Wolf\n              U, \n            \n              Heinicke\n              F, \n            \n              Gr\u00fcndler\n              K, \n            \n              Visser\n              H, \n            \n              Hirsch\n              E. \n          \n          Effective dosages for recording Veraviewepocs dental panoramic images: analog film, digital, and panoramic scout for CBCT. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008;106:571\u2013577."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/40\/1\/article-p76.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/meridian.allenpress.com\/joi\/article-pdf\/40\/1\/76\/2039916\/aaid-joi-d-11-00191.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/40\/1\/article-p76.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/40\/1\/article-p76.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T00:08:28Z","timestamp":1752192508000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/40\/1\/article-p76.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,2]]},"references-count":23,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-11-00191","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"value":"1548-1336","type":"electronic"},{"value":"0160-6972","type":"print"}],"subject":[],"published":{"date-parts":[[2014,2]]}}}