{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,13]],"date-time":"2026-11-13T10:55:29Z","timestamp":1794567329368,"version":"4.9.1"},"reference-count":32,"publisher":"American Academy of Implant Dentistry","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2015,4]]},"abstract":"<jats:p>Placement of zygomatic implants lateral to the maxillary sinus, according to the extrasinus protocol, is one of the treatment options in the rehabilitation of severely atrophic maxilla or following maxillectomy surgery in patients with head and neck cancer. The aim of this study was to investigate the mechanical behavior of a full-arch fixed prosthesis supported by 4 zygomatic implants in the atrophic maxilla under occlusal loading. Results indicated that maximum von Mises stresses were significantly higher under lateral loading compared with vertical loading within the prosthesis and its supporting implants. Peak stresses were concentrated at the prosthesis-abutments interface under vertical loading and the internal line angles of the prosthesis under lateral loading. The zygomatic supporting bone suffered significantly lower stresses. However, the alveolar bone suffered a comparatively higher level of stresses, particularly under lateral loading. Prosthesis displacement under vertical loading was higher than under lateral loading. The zygomatic bone suffered lower stresses than the alveolar bone and prosthesis-implant complex under both vertical and lateral loading. Lateral loading caused a higher level of stresses than vertical loading.<\/jats:p>","DOI":"10.1563\/aaid-joi-d-12-00276","type":"journal-article","created":{"date-parts":[[2013,9,5]],"date-time":"2013-09-05T11:55:58Z","timestamp":1378382158000},"page":"e1-e6","source":"Crossref","is-referenced-by-count":10,"title":["Extrasinus Zygomatic Implant Placement in the Rehabilitation of the Atrophic Maxilla: Three-Dimensional Finite Element Stress Analysis"],"prefix":"10.1563","volume":"41","author":[{"given":"Shihab A.","family":"Romeed","sequence":"first","affiliation":[{"name":"King's College London Dental Institute, London, United Kingdom."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert Nigel","family":"Hays","sequence":"additional","affiliation":[{"name":"Robert Nigel Hayes, Thames Ditton, United Kingdom."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raheel","family":"Malik","sequence":"additional","affiliation":[{"name":"Guys Hospital, London, United Kingdom."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephen M.","family":"Dunne","sequence":"additional","affiliation":[{"name":"King's College London Dental Institute, London, United Kingdom."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"434","reference":[{"key":"i1548-1336-41-2-e1-b01","series-title":"Tissue Integrated Prostheses","first-page":"11","article-title":"Introduction to osseointegration","author":"Br\u00e5nemark\n              PI,","year":"1985","unstructured":"Br\u00e5nemark\n              PI, \n            \n              Zarb\n              GA, \n            \n              Albrektsson\n              T, \n          \n          eds. Introduction to osseointegration. In: Tissue Integrated Prostheses. Chicago, Ill: Quintessence Publishing;1985:11\u201376."},{"key":"i1548-1336-41-2-e1-b02","series-title":"Clin Oral Implants Res","first-page":"768","article-title":"Retrospective success and survival rates of dental implants placed with simultaneous bone augmentation in partially edentulous patients","volume":"25","author":"Bazrafshan\n              N,","year":"2014","unstructured":"Bazrafshan\n              N, \n            \n              Darby\n              I.\n            \n          \n          Retrospective success and survival rates of dental implants placed with simultaneous bone augmentation in partially edentulous patients. Clin Oral Implants Res. 2014;25:768\u2013773."},{"key":"i1548-1336-41-2-e1-b03","series-title":"Ann R Australas Coll Dent Surg","first-page":"23","article-title":"The zygomaticus fixture: an alternative approach for implant anchorage in the posterior maxilla","volume":"15","author":"Higuchi\n              KW.","year":"2000","unstructured":"Higuchi\n              KW.\n            \n          \n          The zygomaticus fixture: an alternative approach for implant anchorage in the posterior maxilla. Ann R Australas Coll Dent Surg. 2000;15:23\u201333."},{"key":"i1548-1336-41-2-e1-b04","series-title":"Periodontology 2000","first-page":"82","article-title":"Use of zygomatic implants to deal with resorbed posterior maxillae","volume":"33","author":"Malvez\n              C,","year":"2003","unstructured":"Malvez\n              C, \n            \n              Daelemans\n              P, \n            \n              Adrianssens\n              P, \n            \n              Durdu\n              F.\n            \n          \n          Use of zygomatic implants to deal with resorbed posterior maxillae. Periodontology 2000. 2003;33:82\u201389."},{"key":"i1548-1336-41-2-e1-b05","series-title":"J Prosthet Dent","first-page":"377","article-title":"Remote implant anchorage for the rehabilitation of maxillary defects","volume":"86","author":"Parel\n              SM,","year":"2001","unstructured":"Parel\n              SM, \n            \n              Br\u00e5nemark\n              PI, \n            \n              Ohrnell\n              LO, \n            \n              Svensson\n              B.\n            \n          \n          Remote implant anchorage for the rehabilitation of maxillary defects. J Prosthet Dent. 2001;86:377\u2013381."},{"key":"i1548-1336-41-2-e1-b06","series-title":"J Oral Maxillofac Surg","first-page":"1418","article-title":"Restoration of the edentulous maxilla: the case for the zygomatic implants","volume":"62","author":"Ferrara\n              ED,","year":"2004","unstructured":"Ferrara\n              ED, \n            \n              Stella\n              JP.\n            \n          \n          Restoration of the edentulous maxilla: the case for the zygomatic implants. J Oral Maxillofac Surg. 2004;62:1418\u20131422."},{"key":"i1548-1336-41-2-e1-b07","series-title":"Med Oral Patol","first-page":"363","article-title":"Rehabilitation of atrophic maxilla: a review of 101 zygomatic implants","volume":"13","author":"Pi-Urgell\n              J,","year":"2008","unstructured":"Pi-Urgell\n              J, \n            \n              Revilla-Guti\u00e9rrez\n              V, \n            \n              Gay-Escoda\n              C.\n            \n          \n          Rehabilitation of atrophic maxilla: a review of 101 zygomatic implants. Med Oral Patol. 2008;13:363\u2013370."},{"key":"i1548-1336-41-2-e1-b08","series-title":"Br\u00e5nemark System Manual","first-page":"4","article-title":"Zygomatic fixture clinical procedures","author":"Br\u00e5nemark\n              PI,","year":"2000","unstructured":"Br\u00e5nemark\n              PI, \n            \n              Engstrand\n              P, \n            \n              Nilsson\n              P, \n            \n              Svensson\n              B, \n            \n              \u00d6hrnell\n              LO.\n            \n          \n          Zygomatic fixture clinical procedures. In: Id\u00e9SG, TryckAB, eds. Br\u00e5nemark System Manual. G\u00f6teborg, Sweden: Nobel Biocare;2000:4\u201327."},{"key":"i1548-1336-41-2-e1-b09","series-title":"Int J Oral Maxillofac Implants","first-page":"665","article-title":"Dias Rezende RC, de Mayo T Restoration of the edentulous maxilla using extra-sinus zygomatic implants combined with anterior conventional implants: a retrospective study","volume":"26","author":"Miglioran\u00e7a\n              RM,","year":"2011","unstructured":"Miglioran\u00e7a\n              RM, \n            \n              Coppede\n              A, \n          \n          Dias Rezende RC, de Mayo T Restoration of the edentulous maxilla using extra-sinus zygomatic implants combined with anterior conventional implants: a retrospective study. Int J Oral Maxillofac Implants. 2011;26:665\u2013672."},{"key":"i1548-1336-41-2-e1-b10","series-title":"J Craniomaxilliofac Surg","first-page":"1","article-title":"Length of the drilling holes of zygomatic implants inserted with the standard technique or a revised method: a comparative study in dry skulls","volume":"10","author":"Corvello\n              PC,","year":"2010","unstructured":"Corvello\n              PC, \n            \n              Montagner\n              A, \n            \n              Batista\n              FC, \n            \n              Smidt\n              R, \n            \n              Shinkai\n              RS.\n            \n          \n          Length of the drilling holes of zygomatic implants inserted with the standard technique or a revised method: a comparative study in dry skulls. J Craniomaxilliofac Surg. 2010;10:1\u20135."},{"key":"i1548-1336-41-2-e1-b11","series-title":"J Prosthet Dent","first-page":"354","article-title":"A new approach to rehabilitate the severely atrophic maxilla using extramaxillary anchored implants in immediate function: a pilot study","volume":"100","author":"Mal\u00f3\n              P,","year":"2008","unstructured":"Mal\u00f3\n              P, \n            \n              Nobre\n              MA, \n            \n              Lopes\n              I.\n            \n          \n          A new approach to rehabilitate the severely atrophic maxilla using extramaxillary anchored implants in immediate function: a pilot study. J Prosthet Dent. 2008;100:354\u2013366."},{"issue":"suppl 1","key":"i1548-1336-41-2-e1-b12","series-title":"Clin Implant Dent Relat Res","first-page":"S47","article-title":"Immediate occlusal loading of Br\u00e5nemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study","volume":"5","author":"Glauser\n              R,","year":"2003","unstructured":"Glauser\n              R, \n            \n              Lundgren\n              AK, \n            \n              Gottlow\n              J, \n            et al\n          . Immediate occlusal loading of Br\u00e5nemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study. Clin Implant Dent Relat Res. 2003;5(suppl 1):S47\u2013S56."},{"key":"i1548-1336-41-2-e1-b13","series-title":"Clin Implant Dent Relat Res","first-page":"114","article-title":"A prospective clinical study on titanium implants in the zygomatic arch for prosthetic rehabilitation of the atrophic edentulous maxilla with a follow-up of 6 months to 5 years","volume":"8","author":"Aparicio\n              C,","year":"2006","unstructured":"Aparicio\n              C, \n            \n              Ouazzani\n              W, \n            \n              Garcia\n              R, \n            \n              Arevalo\n              X, \n            \n              Muela\n              R, \n            \n              Fortes\n              V.\n            \n          \n          A prospective clinical study on titanium implants in the zygomatic arch for prosthetic rehabilitation of the atrophic edentulous maxilla with a follow-up of 6 months to 5 years. Clin Implant Dent Relat Res. 2006;8:114\u2013122."},{"key":"i1548-1336-41-2-e1-b14","series-title":"Clin Implant Dent Relat Res","first-page":"186","article-title":"The establishment of a protocol for the total rehabilitation of atrophic maxillae employing four zygomatic fixtures in an immediate loading system: a 30 month clinical and radiographic follow-up","volume":"9","author":"Duarte\n              LR,","year":"2007","unstructured":"Duarte\n              LR, \n            \n              Filho\n              HN, \n            \n              Francischone\n              CE, \n            \n              Peredo\n              LG, \n            \n              Br\u00e5nemark\n              PI.\n            \n          \n          The establishment of a protocol for the total rehabilitation of atrophic maxillae employing four zygomatic fixtures in an immediate loading system: a 30 month clinical and radiographic follow-up. Clin Implant Dent Relat Res. 2007;9:186\u2013196."},{"key":"i1548-1336-41-2-e1-b15","series-title":"Clin Implant Dent Relat Res","first-page":"55","article-title":"Extra-sinus zygomatic implants: three year experience from a new surgical approach for patients with pronounced buccal concavities in the edentulous maxilla","volume":"12","author":"Aparicio\n              C,","year":"2008","unstructured":"Aparicio\n              C, \n            \n              Ouazzani\n              W, \n            \n              Aparicio\n              A, \n            et al\n          . Extra-sinus zygomatic implants: three year experience from a new surgical approach for patients with pronounced buccal concavities in the edentulous maxilla. Clin Implant Dent Relat Res. 2008;12:55\u201361."},{"key":"i1548-1336-41-2-e1-b16","series-title":"Int J Oral Maxillofac Surg","first-page":"620","article-title":"Three-dimensional finite elemental analysis of zygomatic implants in craniofacial structures","volume":"36","author":"Ujigawa\n              K,","year":"2007","unstructured":"Ujigawa\n              K, \n            \n              Kato\n              Y, \n            \n              Kizu\n              Y, \n            \n              Tonogi\n              M, \n            \n              Yamane\n              GY.\n            \n          \n          Three-dimensional finite elemental analysis of zygomatic implants in craniofacial structures. Int J Oral Maxillofac Surg. 2007;36:620\u2013625."},{"key":"i1548-1336-41-2-e1-b17","series-title":"J Mech Behav Biomed Mater","first-page":"107","article-title":"Biomechanical comparison of implant retained fixed partial dentures with fiber reinforced composite versus conventional metal frameworks: a 3D FEA study","volume":"4","author":"Erkmen\n              E,","year":"2011","unstructured":"Erkmen\n              E, \n            \n              Meri\u00e7\n              G, \n            \n              Kurt\n              A, \n            \n              Tun\u00e7\n              Y, \n            \n              Eser\n              A.\n            \n          \n          Biomechanical comparison of implant retained fixed partial dentures with fiber reinforced composite versus conventional metal frameworks: a 3D FEA study. J Mech Behav Biomed Mater. 2011;4:107\u2013116."},{"key":"i1548-1336-41-2-e1-b18","series-title":"J Oral Implantol","first-page":"231","article-title":"Zygomatic implants: the impact of zygoma bone support on biomechanics","volume":"40","author":"Romeed\n              S,","year":"2014","unstructured":"Romeed\n              S, \n            \n              Malik\n              R, \n            \n              Dunne\n              S.\n            \n          \n          Zygomatic implants: the impact of zygoma bone support on biomechanics. J Oral Implantol. 2014;40:231\u2013237."},{"issue":"suppl 1","key":"i1548-1336-41-2-e1-b19","series-title":"Clin Implant Dent Relat Res","first-page":"e139","article-title":"de Ara\u00fajo Nobre M, Lopes A, Francischone C, Rigolizzo M. \u201cAll-on-4\u201d immediate-function concept for completely edentulous maxillae: a clinical report on the medium (3 years) and long-term (5 years) outcomes","volume":"14","author":"Mal\u00f3\n              P,","year":"2012","unstructured":"Mal\u00f3\n              P, \n          \n          de Ara\u00fajo Nobre M, Lopes A, Francischone C, Rigolizzo M. \u201cAll-on-4\u201d immediate-function concept for completely edentulous maxillae: a clinical report on the medium (3 years) and long-term (5 years) outcomes. Clin Implant Dent Relat Res. 2012;14(suppl 1):e139\u2013e150."},{"issue":"suppl 1","key":"i1548-1336-41-2-e1-b20","series-title":"Clin Implant Dent Relat Res","first-page":"S88","article-title":"All-on-4 immediate-function concept with Br\u00e5nemark system implants for completely edentulous maxillae: a 1-year retrospective clinical study","volume":"7","author":"Mal\u00f3\n              P,","year":"2005","unstructured":"Mal\u00f3\n              P, \n            \n              Rangert\n              B, \n            \n              Nobre\n              M.\n            \n          \n          All-on-4 immediate-function concept with Br\u00e5nemark system implants for completely edentulous maxillae: a 1-year retrospective clinical study. Clin Implant Dent Relat Res. 2005;7(suppl 1):S88\u2013S94."},{"issue":"suppl 1","key":"i1548-1336-41-2-e1-b21","series-title":"Clin Implant Dent Relat Res","first-page":"2","article-title":"\u201cAll-on-four\u201d immediate-function concept with Br\u00e5nemark system implants for completely edentulous mandibles: a retrospective clinical study","volume":"5","author":"Mal\u00f3\n              P,","year":"2003","unstructured":"Mal\u00f3\n              P, \n            \n              Rangert\n              B, \n            \n              Nobre\n              M.\n            \n          \n          \u201cAll-on-four\u201d immediate-function concept with Br\u00e5nemark system implants for completely edentulous mandibles: a retrospective clinical study. Clin Implant Dent Relat Res. 2003;5(suppl 1):2\u20139."},{"key":"i1548-1336-41-2-e1-b22","series-title":"Int J Oral Maxillofac Implants","first-page":"665","article-title":"Dias Rezende RC, de Mayo T. Restoration of the edentulous maxilla using extra-sinus zygomatic implants combined with anterior conventional implants: a retrospective study","volume":"26","author":"Miglioran\u00e7a\n              RM,","year":"2011","unstructured":"Miglioran\u00e7a\n              RM, \n            \n              Copped\u00ea\n              A, \n          \n          Dias Rezende RC, de Mayo T. Restoration of the edentulous maxilla using extra-sinus zygomatic implants combined with anterior conventional implants: a retrospective study. Int J Oral Maxillofac Implants. 2011;26:665\u2013672."},{"issue":"4","key":"i1548-1336-41-2-e1-b23","series-title":"Cochrane Database Syst Rev","article-title":"Interventions for replacing missing teeth: dental implants in zygomatic bone for the rehabilitation of the severely deficient edentulous maxilla","author":"Esposito\n              M,","year":"2005","unstructured":"Esposito\n              M, \n            \n              Worthington\n              HV, \n            \n              Coulthard\n              P.\n            \n          \n          Interventions for replacing missing teeth: dental implants in zygomatic bone for the rehabilitation of the severely deficient edentulous maxilla. Cochrane Database Syst Rev. 2005;(4):CD004151."},{"issue":"3","key":"i1548-1336-41-2-e1-b24","series-title":"Cochrane Database Syst Rev","article-title":"Interventions for replacing missing teeth: dental implants in zygomatic bone for the rehabilitation of the severely deficient edentulous maxilla","author":"Esposito\n              M,","year":"2003","unstructured":"Esposito\n              M, \n            \n              Worthington\n              HV, \n            \n              Thomsen\n              P, \n            \n              Coulthard\n              P.\n            \n          \n          Interventions for replacing missing teeth: dental implants in zygomatic bone for the rehabilitation of the severely deficient edentulous maxilla. Cochrane Database Syst Rev. 2003;(3):CD004151."},{"key":"i1548-1336-41-2-e1-b25","series-title":"Int J Oral Maxillofac Implants","first-page":"667","article-title":"Load transfer by an implant in a sinus-grafted maxillary model","volume":"18","author":"Fanuscu\n              MI,","year":"2003","unstructured":"Fanuscu\n              MI, \n            \n              Iida\n              K, \n            \n              Caputo\n              AA, \n            \n              Nishimura\n              RD.\n            \n          \n          Load transfer by an implant in a sinus-grafted maxillary model. Int J Oral Maxillofac Implants. 2003;18:667\u2013674."},{"key":"i1548-1336-41-2-e1-b26","series-title":"Clin Oral Implants Res","first-page":"407","article-title":"The influence of bone mechanical properties and implant fixation upon bone loading around oral implants","volume":"9","author":"Van Oosterwyck\n              H,","year":"1998","unstructured":"Van Oosterwyck\n              H, \n            \n              Duyck\n              J, \n            \n              Vander Sloten\n              J, \n            et al\n          . The influence of bone mechanical properties and implant fixation upon bone loading around oral implants. Clin Oral Implants Res. 1998;9:407\u2013418."},{"key":"i1548-1336-41-2-e1-b27","series-title":"Int J Oral Maxillofac Implants","first-page":"103","article-title":"Influence of bicortical or monocortical anchorage on maxillary implant stability: a 15-year retrospective study of Br\u00e5nemark system implants","volume":"15","author":"Ivanoff\n              CJ,","year":"2000","unstructured":"Ivanoff\n              CJ, \n            \n              Gr\u00f6ndahl\n              K, \n            \n              Bergstr\u00f6m\n              C, \n            \n              Lekholm\n              U, \n            \n              Br\u00e5nemark\n              PI.\n            \n          \n          Influence of bicortical or monocortical anchorage on maxillary implant stability: a 15-year retrospective study of Br\u00e5nemark system implants. Int J Oral Maxillofac Implants. 2000;15:103\u2013110."},{"key":"i1548-1336-41-2-e1-b28","series-title":"Clin Implant Dent Relat Res","first-page":"55","article-title":"Extra-sinus zygomatic implants: three year experience from a new surgical approach for patients with pronounced buccal concavities in the edentulous maxilla","volume":"12","author":"Ouazzani\n              W,","year":"2010","unstructured":"Ouazzani\n              W, \n            \n              Aparicio\n              A, \n            \n              Fortes\n              V, \n            et al\n          . Extra-sinus zygomatic implants: three year experience from a new surgical approach for patients with pronounced buccal concavities in the edentulous maxilla. Clin Implant Dent Relat Res. 2010;12:55\u201361."},{"issue":"11 suppl","key":"i1548-1336-41-2-e1-b29","series-title":"J Oral Maxillofac Surg","first-page":"60","article-title":"Fixed rehabilitation of the edentulous maxilla: possibilities and clinical outcome","volume":"67","author":"Att\n              W,","year":"2009","unstructured":"Att\n              W, \n            \n              Bernhart\n              J, \n            \n              Strub\n              JR.\n            \n          \n          Fixed rehabilitation of the edentulous maxilla: possibilities and clinical outcome. J Oral Maxillofac Surg. 2009;67(11 suppl):60\u201373."},{"key":"i1548-1336-41-2-e1-b30","series-title":"J Oral Implantol","first-page":"653","article-title":"Rehabilitation of atrophic posterior maxilla with zygomatic implants: review","volume":"38","year":"2012","unstructured":"Candel Mart\u00ed E, Carrillo Garc\u00eda C, Pe\u00f1arrocha Oltra D, Pe\u00f1arrocha M. Rehabilitation of atrophic posterior maxilla with zygomatic implants: review. J Oral Implantol. 2012;38:653\u2013657."},{"key":"i1548-1336-41-2-e1-b31","series-title":"Int J Oral Maxillofac Surg","first-page":"1120","article-title":"Biomechanical three-dimensional finite-element analysis of maxillary prostheses with implants: design of number and position of implants for maxillary prostheses after hemimaxillectomy","volume":"39","author":"Miyamoto\n              S,","year":"2010","unstructured":"Miyamoto\n              S, \n            \n              Ujigawa\n              K, \n            \n              Kizu\n              Y, \n            \n              Tonogi\n              M, \n            \n              Yamane\n              GY.\n            \n          \n          Biomechanical three-dimensional finite-element analysis of maxillary prostheses with implants: design of number and position of implants for maxillary prostheses after hemimaxillectomy. Int J Oral Maxillofac Surg. 2010;39:1120\u20131126."},{"key":"i1548-1336-41-2-e1-b32","series-title":"Int J Oral Maxillofac Surg","first-page":"620","article-title":"Three-dimensional finite elemental analysis of zygomatic implants in craniofacial structures","volume":"36","author":"Ujigawa\n              K,","year":"2007","unstructured":"Ujigawa\n              K, \n            \n              Kato\n              Y, \n            \n              Kizu\n              Y, \n            \n              Tonogi\n              M, \n            \n              Yamane\n              GY.\n            \n          \n          Three-dimensional finite elemental analysis of zygomatic implants in craniofacial structures. Int J Oral Maxillofac Surg. 2007;36:620\u2013625."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/41\/2\/article-pe1.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/meridian.allenpress.com\/joi\/article-pdf\/41\/2\/e1\/2035413\/aaid-joi-d-12-00276.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/41\/2\/article-pe1.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/41\/2\/article-pe1.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T00:11:00Z","timestamp":1752192660000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/41\/2\/article-pe1.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,4]]},"references-count":32,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-12-00276","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"value":"1548-1336","type":"electronic"},{"value":"0160-6972","type":"print"}],"subject":[],"published":{"date-parts":[[2015,4]]}}}