{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,11]],"date-time":"2025-11-11T13:21:59Z","timestamp":1762867319874,"version":"3.41.2"},"reference-count":29,"publisher":"American Academy of Implant Dentistry","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,4]]},"abstract":"<jats:p>This study aimed to compare the primary and secondary stability, measured by resonance frequency analysis (RFA), in implants of different lengths installed in areas submitted to maxillary sinus lift. Correlation between RFA and implant insertion torque was also assessed. Twenty implants of 9 and 11 mm were inserted in areas submitted to maxillary sinus lift. The insertion torque was measured by the Bien Air motor. Osstell, through RFA, determined the implant stability quotient (ISQ) 2 times: the day of implant installation (T1) and 90 days after implant installation (T2). No differences were observed in the ISQ between T1 and T2 when the 20 implants were grouped, nor when the 9 mm implants were evaluated separately. In contrast, when the 11 mm values were evaluated separately, the ISQ was significantly higher in T2 than in T1 (<jats:italic>P<\/jats:italic> &lt; .05). In T1, 9 mm implants had a higher ISQ than 11 mm ones (<jats:italic>P<\/jats:italic> &lt; .05), whereas in T2, the implants of 11 mm showed a higher ISQ than did the 9 mm implants (<jats:italic>P<\/jats:italic> &lt; .05). There was no difference in insertion torque between 9 and 11 mm implants (<jats:italic>P<\/jats:italic> &gt; .05), nor was there a correlation between ISQ and insertion torque (<jats:italic>P<\/jats:italic> &gt; .05). In conclusion, longer implants (11 mm) presented a significant increase in ISQ values during the healing period when installed in areas previously submitted to maxillary sinus lift. This phenomenon was not observed for shorter implants (9 mm). Finally, no correlation was observed between ISQ and insertion torque.<\/jats:p>","DOI":"10.1563\/aaid-joi-d-17-00094","type":"journal-article","created":{"date-parts":[[2018,1,5]],"date-time":"2018-01-05T11:08:03Z","timestamp":1515150483000},"page":"109-113","source":"Crossref","is-referenced-by-count":3,"title":["Assessment of Dental Implant Stability in Areas Previously Submitted to Maxillary Sinus Elevation"],"prefix":"10.1563","volume":"44","author":[{"given":"Karine C\u00e2mara","family":"Silva","sequence":"first","affiliation":[{"name":"Graduate Program in Dentistry, Pontifical Catholic University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Elton Gon\u00e7alves","family":"Zen\u00f3bio","sequence":"additional","affiliation":[{"name":"Graduate Program in Dentistry, Pontifical Catholic University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paulo Eduardo Alencar","family":"Souza","sequence":"additional","affiliation":[{"name":"Graduate Program in Dentistry, Pontifical Catholic University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rodrigo Villamarim","family":"Soares","sequence":"additional","affiliation":[{"name":"Graduate Program in Dentistry, Pontifical Catholic University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maur\u00edcio Greco","family":"Cosso","sequence":"additional","affiliation":[{"name":"Graduate Program in Dentistry, Pontifical Catholic University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martinho Campolina Rebello","family":"Horta","sequence":"additional","affiliation":[{"name":"Graduate Program in Dentistry, Pontifical Catholic University of Minas Gerais, Belo Horizonte, Minas Gerais, Brazil."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"434","reference":[{"key":"i1548-1336-44-2-109-b01","series-title":"Int J Prosthodont","first-page":"491","article-title":"Assessment of implant stability as a prognostic determinant","volume":"11","author":"Meredith \n              N.","year":"1998","unstructured":"Meredith \n              N. \n            \n          \n          Assessment of implant stability as a prognostic determinant. Int J Prosthodont. 1998;11:491\u2013501."},{"key":"i1548-1336-44-2-109-b02","series-title":"Clin Oral Implants Res","first-page":"244","article-title":"Significance of primary stability for osseointegration of dental implants","volume":"17","author":"Lioubavina-Hack \n              N,","year":"2006","unstructured":"Lioubavina-Hack \n              N, \n            \n            \n              Lang \n              NP, \n            \n            \n              Karring \n              T. \n            \n          \n          Significance of primary stability for osseointegration of dental implants. Clin Oral Implants Res. 2006;17:244\u2013250."},{"key":"i1548-1336-44-2-109-b03","series-title":"Biomed Pharmacother","first-page":"487","article-title":"Osteoporosis and biomaterial osteointegration","volume":"58","author":"Fini \n              M,","year":"2004","unstructured":"Fini \n              M, \n            \n            \n              Giavaresi \n              G, \n            \n            \n              Torricelli \n              P, \n            \n            et al. \n          Osteoporosis and biomaterial osteointegration. Biomed Pharmacother. 2004;58:487\u2013493."},{"key":"i1548-1336-44-2-109-b04","series-title":"Med Oral Patol Oral Cir Bucal","first-page":"e538","article-title":"Measurement of dental implant stability by resonance frequency analysis: a review of the literature","volume":"14","author":"Quesada-Garc\u00eda \n              MP,","year":"2009","unstructured":"Quesada-Garc\u00eda \n              MP, \n            \n            \n              Prados-S\u00e1nchez \n              E, \n            \n            \n              Olmedo-Gaya \n              MV, \n            \n            \n              Mu\u00f1oz-Soto \n              E, \n            \n            \n              Gonz\u00e1lez-Rodr\u00edguez \n              MP, \n            \n            \n              Valllecillo-Capilla \n              M. \n            \n          \n          Measurement of dental implant stability by resonance frequency analysis: a review of the literature. Med Oral Patol Oral Cir Bucal. 2009;14:e538\u2013e546."},{"key":"i1548-1336-44-2-109-b05","series-title":"Int J Oral Maxillofac Implants","first-page":"743","article-title":"Methods used to assess implant stability: current status","volume":"22","author":"Atsumi \n              M,","year":"2007","unstructured":"Atsumi \n              M, \n            \n            \n              Park \n              SH, \n            \n            \n              Wang \n              HL. \n            \n          \n          Methods used to assess implant stability: current status. Int J Oral Maxillofac Implants. 2007;22:743\u2013754."},{"key":"i1548-1336-44-2-109-b06","series-title":"Int J Oral Maxillofac Surg","first-page":"279","article-title":"Assessment of bone quality from placement resistance during implant surgery","volume":"9","author":"Johansson \n              P,","year":"1994","unstructured":"Johansson \n              P, \n            \n            \n              Strid \n              KG. \n            \n          \n          Assessment of bone quality from placement resistance during implant surgery. Int J Oral Maxillofac Surg. 1994;9:279\u2013288."},{"key":"i1548-1336-44-2-109-b07","series-title":"Clin Oral Implants Res","first-page":"520","article-title":"Predicting osseointegration by means of implant primary stability: a resonance-frequency analysis study with delayed and immediately loaded ITI SLA implants","volume":"15","author":"Nedir \n              R,","year":"2004","unstructured":"Nedir \n              R, \n            \n            \n              Bischof \n              M, \n            \n            \n              Szmukier-Moncler \n              S, \n            \n            \n              Bernard \n              JP, \n            \n            \n              Samson \n              J. \n            \n          \n          Predicting osseointegration by means of implant primary stability: a resonance-frequency analysis study with delayed and immediately loaded ITI SLA implants. Clin Oral Implants Res. 2004;15:520\u2013528."},{"key":"i1548-1336-44-2-109-b08","series-title":"Clin Oral Implants Res","first-page":"226","article-title":"Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla","volume":"8","author":"Meredith \n              N,","year":"1997","unstructured":"Meredith \n              N, \n            \n            \n              Book \n              K\n            , Friberg B, Jemt T, Sennerby L. Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla. Clin Oral Implants Res. 1997;8:226\u2013233."},{"key":"i1548-1336-44-2-109-b09","series-title":"Periodontol 2000","first-page":"51","article-title":"Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications","volume":"47","author":"Sennerby \n              L,","year":"2008","unstructured":"Sennerby \n              L, \n            \n            \n              Meredith \n              N. \n            \n          \n          Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontol 2000. 2008;47:51\u201366."},{"key":"i1548-1336-44-2-109-b10","series-title":"Int J Oral Maxillofac Implants","first-page":"525","article-title":"Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of both techniques in a clinical trial","volume":"23","author":"Zix \n              J,","year":"2008","unstructured":"Zix \n              J, \n            \n            \n              Hug \n              S, \n            \n            \n              Kessler-Liechti \n              G, \n            \n            \n              Mericske-Stern \n              R. \n            \n          \n          Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of both techniques in a clinical trial. Int J Oral Maxillofac Implants. 2008;23:525\u2013530."},{"key":"i1548-1336-44-2-109-b11","series-title":"J Oral Rehabil","first-page":"755","article-title":"Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants","volume":"36","author":"Kahraman \n              S,","year":"2009","unstructured":"Kahraman \n              S, \n            \n            \n              Bal \n              BT, \n            \n            \n              Asar \n              NV, \n            \n            \n              Turkyilmaz \n              I, \n            \n            \n              T\u00f6z\u00fcm \n              TF. \n            \n          \n          Clinical study on the insertion torque and wireless resonance frequency analysis in the assessment of torque capacity and stability of self-tapping dental implants. J Oral Rehabil. 2009;36:755\u2013761."},{"key":"i1548-1336-44-2-109-b12","series-title":"Implant Dent","first-page":"607","article-title":"Relationship between insertion torque and resonance frequency measurements, performed by resonance frequency analysis, in micro mobility of dental implants: an in vitro study","volume":"24","author":"Brizuela-Velasco \n              A,","year":"2015","unstructured":"Brizuela-Velasco \n              A, \n            \n            \n              \u00c1lvarez-Arenal \n              A, \n            \n            \n              Gil-Mur \n              FJ, \n            \n            et al. \n          Relationship between insertion torque and resonance frequency measurements, performed by resonance frequency analysis, in micro mobility of dental implants: an in vitro study. Implant Dent. 2015;24:607\u2013611."},{"key":"i1548-1336-44-2-109-b13","series-title":"J Oral Rehabil","first-page":"754","article-title":"A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Br\u00e5nemark system implants","volume":"33","author":"T\u00fcrkyilmaz \n              I.","year":"2006","unstructured":"T\u00fcrkyilmaz \n              I. \n            \n          \n          A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Br\u00e5nemark system implants. J Oral Rehabil. 2006;33:754\u2013759."},{"key":"i1548-1336-44-2-109-b14","series-title":"Clin Implant Dent Relat Res","first-page":"52","article-title":"Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study","volume":"11","author":"T\u00fcrkyilmaz \n              I,","year":"2009","unstructured":"T\u00fcrkyilmaz \n              I, \n            \n            \n              Sennerby \n              L, \n            \n            \n              Yilmaz \n              B, \n            \n            \n              Bilecenoglu \n              B, \n            \n            \n              Ozbek \n              EN. \n            \n          \n          Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study. Clin Implant Dent Relat Res. 2009;11:52\u201358."},{"key":"i1548-1336-44-2-109-b15","series-title":"Int J Oral Maxillofac Implants","first-page":"297","article-title":"A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study","volume":"28","author":"Friberg \n              B,","year":"1999","unstructured":"Friberg \n              B, \n            \n            \n              Sennerby \n              L, \n            \n            \n              Meredith \n              N, \n            \n            \n              Lekholm \n              U. \n            \n          \n          A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Implants. 1999;28:297\u2013303."},{"key":"i1548-1336-44-2-109-b16","series-title":"Int J Oral Maxillofac Implants","first-page":"578","article-title":"A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading","volume":"19","author":"Da Cunha \n              HA,","year":"2004","unstructured":"Da Cunha \n              HA, \n            \n            \n              Francischone \n              CE, \n            \n            \n              Filho \n              HN, \n            \n            \n              Oliveira \n              RC. \n            \n          \n          A comparison between cutting torque and resonance frequency in the assessment of primary stability and final torque capacity of standard and TiUnite single-tooth implants under immediate loading. Int J Oral Maxillofac Implants. 2004;19: 578\u2013585."},{"key":"i1548-1336-44-2-109-b17","series-title":"Int J Oral Maxillofac Implants","first-page":"169","article-title":"Torque-fitting and resonance frequency analyses of implants in conventional sockets versus controlled bone defects in vitro","volume":"39","author":"Ak\u00e7a \n              K,","year":"2010","unstructured":"Ak\u00e7a \n              K, \n            \n            \n              K\u00f6kat \n              AM, \n            \n            \n              C\u00f6mert \n              A, \n            \n            \n              Akkocaoglu \n              M, \n            \n            \n              Tekdemir \n              I, \n            \n            \n              \u00c7ehreli \n              MCC. \n            \n          \n          Torque-fitting and resonance frequency analyses of implants in conventional sockets versus controlled bone defects in vitro. Int J Oral Maxillofac Implants. 2010;39:169\u2013173."},{"key":"i1548-1336-44-2-109-b18","series-title":"Int J Oral Maxillofac Implants","first-page":"1051","article-title":"Relationships between bone density values from cone beam computed tomography, maximum insertion torque, and resonance frequency analysis at implant placement: a pilot study","volume":"26","author":"Fuster-Torres \n              MA,","year":"2011","unstructured":"Fuster-Torres \n              MA, \n            \n            \n              Pe\u00f1arrocha-Diago \n              M, \n            \n            \n              Pe\u00f1arrocha-Oltra \n              D, \n            \n            \n              Pe\u00f1arrocha-Diago \n              M. \n            \n          \n          Relationships between bone density values from cone beam computed tomography, maximum insertion torque, and resonance frequency analysis at implant placement: a pilot study. Int J Oral Maxillofac Implants. 2011;26:1051\u20131056."},{"key":"i1548-1336-44-2-109-b19","series-title":"Clin Implant Dent Relat Res","first-page":"637","article-title":"Development of a new implant primary stability parameter: insertion torque revisited","volume":"15","author":"Degidi \n              M,","year":"2013","unstructured":"Degidi \n              M, \n            \n            \n              Daprile \n              G, \n            \n            \n              Piattelli \n              A, \n            \n            \n              Lezzi \n              G. \n            \n          \n          Development of a new implant primary stability parameter: insertion torque revisited. Clin Implant Dent Relat Res. 2013;15:637\u2013644."},{"key":"i1548-1336-44-2-109-b20","series-title":"Int J Oral Maxillofac Surg","first-page":"747","article-title":"Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: a pilot study","volume":"20","author":"Zix \n              J,","year":"2005","unstructured":"Zix \n              J, \n            \n            \n              Kessler-Liechti \n              G, \n            \n            \n              Mericske-Stern \n              R. \n            \n          \n          Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: a pilot study. Int J Oral Maxillofac Surg. 2005;20:747\u2013752."},{"key":"i1548-1336-44-2-109-b21","series-title":"Clin Implant Dent Relat Res","first-page":"915","article-title":"Comparison of implant stability by means of resonance frequency analysis for flapless and conventionally inserted implants","volume":"4","author":"Katsoulis \n              J,","year":"2012","unstructured":"Katsoulis \n              J, \n            \n            \n              Avrampou \n              M, \n            \n            \n              Spycher \n              C, \n            \n            \n              Stipic \n              M, \n            \n            \n              Enkling \n              N, \n            \n            \n              Mericske-Stern \n              R. \n            \n          \n          Comparison of implant stability by means of resonance frequency analysis for flapless and conventionally inserted implants. Clin Implant Dent Relat Res. 2012;4:915\u2013923."},{"key":"i1548-1336-44-2-109-b22","series-title":"Clin Oral Investig","first-page":"257","article-title":"Clinical study on the primary stability of two dental implant systems with resonance frequency analysis","volume":"11","author":"Rabel \n              A,","year":"2007","unstructured":"Rabel \n              A, \n            \n            \n              K\u00f6hler \n              SG, \n            \n            \n              Schmidt-Westhausen \n              AM. \n            \n          \n          Clinical study on the primary stability of two dental implant systems with resonance frequency analysis. Clin Oral Investig. 2007;11:257\u2013265."},{"key":"i1548-1336-44-2-109-b23","series-title":"Clin Implant Dent Relat Res","first-page":"61","article-title":"Stability Evaluation of implants integrated in grafted and no grafted maxillary bone: a clinical study from implant placement to abutment connection","volume":"14","author":"Rasmusson \n              L,","year":"2012","unstructured":"Rasmusson \n              L, \n            \n            \n              Thor \n              A, \n            \n            \n              Sennerby \n              L. \n            \n          \n          Stability Evaluation of implants integrated in grafted and no grafted maxillary bone: a clinical study from implant placement to abutment connection. Clin Implant Dent Relat Res. 2012;14:61\u201366."},{"key":"i1548-1336-44-2-109-b24","series-title":"Clin Oral Implants Res","first-page":"135","article-title":"Comparisons between Bio-Oss and Straumann Bone Ceramic in immediate and staged implant placement in dogs mandible bone defects","volume":"24","author":"Antunes \n              AA.,","year":"2013","unstructured":"Antunes \n              AA., \n            \n            \n              Oliveira Neto \n              P, \n            \n            \n              Santis \n              E, \n            \n            \n              Caneva \n              M, \n            \n            \n              Botticelli \n              D, \n            \n            \n              Salata \n              LA. \n            \n          \n          Comparisons between Bio-Oss and Straumann Bone Ceramic in immediate and staged implant placement in dogs mandible bone defects. Clin Oral Implants Res. 2013;24:135\u2013142."},{"key":"i1548-1336-44-2-109-b25","series-title":"Clin Implant Dent Relat Res","first-page":"81","article-title":"Early loading of maxillary fixed cross-arch dental prostheses supported by six or eight oxidized titanium implants: results after 1 year of loading, case series","volume":"5","author":"Olsson \n              M,","year":"2003","unstructured":"Olsson \n              M, \n            \n            \n              Urde \n              G, \n            \n            \n              Andersen \n              JB, \n            \n            \n              Sennerby \n              L. \n            \n          \n          Early loading of maxillary fixed cross-arch dental prostheses supported by six or eight oxidized titanium implants: results after 1 year of loading, case series. Clin Implant Dent Relat Res. 2003;5:81\u201387."},{"key":"i1548-1336-44-2-109-b26","series-title":"Int J Oral Maxillofac Implants","first-page":"584","article-title":"A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants","volume":"20","author":"Balshi \n              SF,","year":"2005","unstructured":"Balshi \n              SF, \n            \n            \n              Allen \n              FD, \n            \n            \n              Wolfinger \n              GJ, \n            \n            \n              Balshi \n              TJ. \n            \n          \n          A resonance frequency analysis assessment of maxillary and mandibular immediately loaded implants. Int J Oral Maxillofac Implants. 2005;20:584\u2013594."},{"key":"i1548-1336-44-2-109-b27","series-title":"Clin Oral Implants Res","first-page":"598","article-title":"Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length","volume":"21","author":"Sim \n              CPC,","year":"2010","unstructured":"Sim \n              CPC, \n            \n            \n              Lang \n              NP. \n            \n          \n          Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length. Clin Oral Implants Res. 2010;21:598\u2013604."},{"key":"i1548-1336-44-2-109-b28","series-title":"Clin Oral Implants Res","first-page":"572","article-title":"Evaluation of local cancellous bone amelioration by poly-L-DL-lactide copolymers to improve primary stability of dental implants: a biomechanical study in sheep","volume":"26","author":"Stubinger \n              S,","year":"2015","unstructured":"Stubinger \n              S, \n            \n            \n              Thomas \n              JW, \n            \n            \n              Drechsler \n              HA, \n            \n            et al. \n          Evaluation of local cancellous bone amelioration by poly-L-DL-lactide copolymers to improve primary stability of dental implants: a biomechanical study in sheep. Clin Oral Implants Res. 2015;26:572\u2013580."},{"key":"i1548-1336-44-2-109-b29","series-title":"Implant Dent","first-page":"672","article-title":"Resonance frequency analysis, insertion torque, and bone to implant contact of 4 implant surfaces: comparison and correlation study in sheep","volume":"23","author":"Dagher \n              M,","year":"2014","unstructured":"Dagher \n              M, \n            \n            \n              Mokbel \n              N, \n            \n            \n              Jabbour \n              G, \n            \n            \n              Naaman \n              N. \n            \n          \n          Resonance frequency analysis, insertion torque, and bone to implant contact of 4 implant surfaces: comparison and correlation study in sheep. Implant Dent2014;23:672\u2013678."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/44\/2\/article-p109.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/meridian.allenpress.com\/joi\/article-pdf\/44\/2\/109\/2036070\/aaid-joi-d-17-00094.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/44\/2\/article-p109.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/44\/2\/article-p109.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T00:14:55Z","timestamp":1752192895000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/44\/2\/article-p109.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,4]]},"references-count":29,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-17-00094","relation":{},"ISSN":["0160-6972","1548-1336"],"issn-type":[{"type":"print","value":"0160-6972"},{"type":"electronic","value":"1548-1336"}],"subject":[],"published":{"date-parts":[[2018,4]]}}}