{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,9]],"date-time":"2026-03-09T20:27:46Z","timestamp":1773088066598,"version":"3.50.1"},"reference-count":63,"publisher":"American Academy of Implant Dentistry","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,4]]},"abstract":"<jats:p>This study investigated the marginal and internal fit and retention of crowns fabricated using 4 different castable pattern production methods, namely plastic burn out coping, computer-aided design and computer-aided manufacturing (CAD-CAM) milled (CAD-CAM-M), CAD-CAM additive (CAD-CAM-A), and conventional. This study consisted of 5 groups including 2 different brands of burn out coping groups (Burn out-Straumann [Burn out-S] group and Burn out-Implance [Burn out-I] group), the CAD-CAM-M group, the CAD-CAM-A group, and the conventional group. A total of 50 metal crown copings were produced in each group with 10 metal crown copings. The marginal gap of the specimens was measured twice\u2014both before and after the cementation and thermocycling processes using a stereomicroscope. A total of 5 specimens were selected randomly\u20141 from each group for scanning electron microscopy analysis and sectioned longitudinally. The pull-out test was performed on the remaining 45 specimens. The lowest marginal gap value was observed in the Burn out-S group before and after cementation with 88.54\u201397.48 \u03bcm, respectively, while the highest marginal gap was observed in the conventional group (186.27\u2013200.58 \u03bcm). Implant systems did not significantly affect the marginal gap values (<jats:italic>P<\/jats:italic> &gt; .05). Marginal gap values increased significantly after cementation and thermal cycling in all the groups (<jats:italic>P<\/jats:italic> &lt; .0001). The highest retention value was measured in the Burn out-S group while the lowest in the CAD-CAM-A group. The highest occlusal cement gap values were observed in the coping groups (Burn out-S and Burn out-I groups), and the lowest in the conventional group in the scanning electron microscopy analysis. The marginal fit and retention values of the prefabricated plastic burn out coping technique was superior when compared with the other techniques, providing that internal fit was superior with the conventional technique.<\/jats:p>","DOI":"10.1563\/aaid-joi-d-20-00069","type":"journal-article","created":{"date-parts":[[2023,2,16]],"date-time":"2023-02-16T17:06:30Z","timestamp":1676567190000},"page":"157-167","source":"Crossref","is-referenced-by-count":3,"title":["Effect of Additive and Subtractive Coping Production Techniques on Retention and Marginal Fit of Implant Supported Crowns"],"prefix":"10.1563","volume":"49","author":[{"given":"Hayriye Senturk","family":"Cesmeci","sequence":"first","affiliation":[{"name":"Department of Prosthodontics, Faculty of Dentistry, University of Erciyes, Kayseri, Turkey."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hasan Onder","family":"Gumus","sequence":"additional","affiliation":[{"name":"Division of Dental Biomaterials, Center for Dental Medicine, Clinic for Reconstructive Dentistry, University of Zurich, Switzerland."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mutlu","family":"\u00d6zcan","sequence":"additional","affiliation":[{"name":"Division of Dental Biomaterials, Center for Dental Medicine, Clinic for Reconstructive Dentistry, University of Zurich, Switzerland."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"434","reference":[{"key":"i1548-1336-49-2-157-b01","series-title":"J Prosthet Dent","first-page":"18","article-title":"A standardized method for determination of crown margin fidelity","volume":"64","author":"Sorensen","year":"1990","unstructured":"Sorensen\n              JA\n            .\n\t\t\t\t\t\n          A standardized method for determination of crown margin fidelity.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t1990;64:\n\t\t\t\t\t18\u201324."},{"key":"i1548-1336-49-2-157-b02","series-title":"Int J Oral Maxillofac Implants","first-page":"527","article-title":"Microbial leakage and marginal fit of the implant-abutment interface","volume":"12","author":"Jansen","year":"1997","unstructured":"Jansen\n              VK\n            ,\n\t\t\t\t\t\tConradsG,\n\t\t\t\t\t\tRichterEJ.\n\t\t\t\t\t\n          Microbial leakage and marginal fit of the implant-abutment interface.\n\t\t\t\t\tInt J Oral Maxillofac Implants.\n\t\t\t\t\t1997;12:\n\t\t\t\t\t527\u2013540."},{"key":"i1548-1336-49-2-157-b03","series-title":"Int J Oral Maxillofac Implants","first-page":"151","article-title":"In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw","volume":"11","author":"Jemt","year":"1996","unstructured":"Jemt\n              T\n            .\n\t\t\t\t\t\n          In vivo measurements of precision of fit involving implant-supported prostheses in the edentulous jaw.\n\t\t\t\t\tInt J Oral Maxillofac Implants.\n\t\t\t\t\t1996;11:\n\t\t\t\t\t151\u2013158."},{"key":"i1548-1336-49-2-157-b04","series-title":"Clin Oral Implants Res","first-page":"108","article-title":"Cementable implant crowns composed of cast superstructure frameworks luted to electroformed primary copings: an in vitro retention study","volume":"18","author":"Di Felice","year":"2007","unstructured":"Di Felice\n              R\n            ,\n\t\t\t\t\t\tRappelliG,\n\t\t\t\t\t\tCamaioniE,\n\t\t\t\t\t\tCattaniM,\n\t\t\t\t\t\tMeyerJM,\n\t\t\t\t\t\tBelserUC.\n\t\t\t\t\t\n          Cementable implant crowns composed of cast superstructure frameworks luted to electroformed primary copings: an in vitro retention study.\n\t\t\t\t\tClin Oral Implants Res.\n\t\t\t\t\t2007;18:\n\t\t\t\t\t108\u2013113."},{"key":"i1548-1336-49-2-157-b05","series-title":"Braz Dent J","first-page":"515","article-title":"Neves FDd, Mattos MdGCd, Rodrigues RCS, Ribeiro RF. Implant\/abutment vertical misfit of one-piece cast frameworks made with different materials","volume":"21","author":"Barbosa","year":"2010","unstructured":"Barbosa\n              GAS\n            ,\n\t\t\t\t\t\n          Neves FDd, Mattos MdGCd, Rodrigues RCS, Ribeiro RF. Implant\/abutment vertical misfit of one-piece cast frameworks made with different materials.\n\t\t\t\t\tBraz Dent J.\n\t\t\t\t\t2010;21:\n\t\t\t\t\t515\u2013519."},{"key":"i1548-1336-49-2-157-b06","series-title":"Int J Oral Maxillofac Implants","first-page":"506","article-title":"Assessing the fit of implant fixed prostheses: a critical review","volume":"25","author":"Abduo","year":"2009","unstructured":"Abduo\n              J\n            ,\n\t\t\t\t\t\tBennaniV,\n\t\t\t\t\t\tWaddellN,\n\t\t\t\t\t\tLyonsK,\n\t\t\t\t\t\tSwainM.\n\t\t\t\t\t\n          Assessing the fit of implant fixed prostheses: a critical review.\n\t\t\t\t\tInt J Oral Maxillofac Implants.\n\t\t\t\t\t2009;25:\n\t\t\t\t\t506\u2013515."},{"key":"i1548-1336-49-2-157-b07","series-title":"Contemporary Fixed Prosthodontics","author":"Rosenstiel","year":"2006","unstructured":"Rosenstiel\n              SF\n            ,\n\t\t\t\t\t\tLandMF,\n\t\t\t\t\t\tFujimotoJ.\n\t\t\t\t\t\n          \n            Contemporary Fixed Prosthodontics\n          .\n\t\t\t\t\tAmsterdam:\n\t\t\t\t\tElsevier Health Sciences;2006."},{"key":"i1548-1336-49-2-157-b08","series-title":"Dent Cos","first-page":"1117","article-title":"A new and accurate method of making gold inlays","volume":"49","author":"Taggart","year":"1907","unstructured":"Taggart\n              WH\n            .\n\t\t\t\t\t\n          A new and accurate method of making gold inlays.\n\t\t\t\t\tDent Cos.\n\t\t\t\t\t1907;49:\n\t\t\t\t\t1117\u20131121."},{"key":"i1548-1336-49-2-157-b09","series-title":"J Indian Prosthodont Soc","first-page":"102","article-title":"Comparison of marginal and internal adaptation of copings fabricated from three different fabrication techniques: an in vitro study","volume":"18","author":"Arora","year":"2018","unstructured":"Arora\n              A\n            ,\n\t\t\t\t\t\tYadavA,\n\t\t\t\t\t\tUpadhyayaV,\n\t\t\t\t\t\tJainP,\n\t\t\t\t\t\tVermaM.\n\t\t\t\t\t\n          Comparison of marginal and internal adaptation of copings fabricated from three different fabrication techniques: an in vitro study.\n\t\t\t\t\tJ Indian Prosthodont Soc.\n\t\t\t\t\t2018;18:\n\t\t\t\t\t102."},{"key":"i1548-1336-49-2-157-b10","series-title":"Eur J Prosthodont Restor Dent","first-page":"10","article-title":"The accuracy of fit of crowns made from wax patterns produced conventionally (hand formed) and via CAD\/CAM technology","volume":"24","author":"Fathi","year":"2016","unstructured":"Fathi\n              HM\n            ,\n\t\t\t\t\t\tAl-MasoodyAH,\n\t\t\t\t\t\tEl-GhezawiN,\n\t\t\t\t\t\tJohnsonA.\n\t\t\t\t\t\n          The accuracy of fit of crowns made from wax patterns produced conventionally (hand formed) and via CAD\/CAM technology.\n\t\t\t\t\tEur J Prosthodont Restor Dent.\n\t\t\t\t\t2016;24:\n\t\t\t\t\t10\u201317."},{"key":"i1548-1336-49-2-157-b11","series-title":"Eur J Prosthodont Restor Dent","first-page":"31","article-title":"Marginal and internal gap of handmade, milled and 3d printed additive manufactured patterns for pressed lithium disilicate onlay restorations","volume":"26","author":"Revilla-Leon","year":"2018","unstructured":"Revilla-Leon\n              M\n            ,\n\t\t\t\t\t\tOlea-VielbaM,\n\t\t\t\t\t\tEsteso-SaizA,\n\t\t\t\t\t\tMartinez-KlemmI,\n\t\t\t\t\t\t\u00d6zcanM.\n\t\t\t\t\t\n          Marginal and internal gap of handmade, milled and 3d printed additive manufactured patterns for pressed lithium disilicate onlay restorations.\n\t\t\t\t\tEur J Prosthodont Restor Dent.\n\t\t\t\t\t2018;26:\n\t\t\t\t\t31\u201338."},{"key":"i1548-1336-49-2-157-b12","series-title":"J Prosthet Dent","first-page":"398","article-title":"Die spacer thickness reproduction for central incisor crown fabrication with combined computer-aided design and 3D printing technology: an in vitro study","volume":"113","author":"Hoang","year":"2015","unstructured":"Hoang\n              LN\n            ,\n\t\t\t\t\t\tThompsonGA,\n\t\t\t\t\t\tChoS-H,\n\t\t\t\t\t\tBerzinsDW,\n\t\t\t\t\t\tAhnKW.\n\t\t\t\t\t\n          Die spacer thickness reproduction for central incisor crown fabrication with combined computer-aided design and 3D printing technology: an in vitro study.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2015;113:\n\t\t\t\t\t398\u2013404."},{"key":"i1548-1336-49-2-157-b13","series-title":"J Indian Prosthodont Soc","first-page":"373","article-title":"Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: a comparative in vitro study","volume":"17","author":"Ullattuthodi","year":"2017","unstructured":"Ullattuthodi\n              S\n            ,\n\t\t\t\t\t\tCherianKP,\n\t\t\t\t\t\tAnandkumarR,\n\t\t\t\t\t\tNambiarMS.\n\t\t\t\t\t\n          Marginal and internal fit of cobalt-chromium copings fabricated using the conventional and the direct metal laser sintering techniques: a comparative in vitro study.\n\t\t\t\t\tJ Indian Prosthodont Soc.\n\t\t\t\t\t2017;17:\n\t\t\t\t\t373\u2013380."},{"key":"i1548-1336-49-2-157-b14","series-title":"J Prosthodont","first-page":"167","article-title":"The effect of different fabrication steps on the marginal adaptation of two types of glass-infiltrated ceramic crown copings fabricated by CAD\/CAM technology","volume":"21","author":"Alghazzawi","year":"2012","unstructured":"Alghazzawi\n              TF\n            ,\n\t\t\t\t\t\tLiuPR,\n\t\t\t\t\t\tEssigME.\n\t\t\t\t\t\n          The effect of different fabrication steps on the marginal adaptation of two types of glass-infiltrated ceramic crown copings fabricated by CAD\/CAM technology.\n\t\t\t\t\tJ Prosthodont.\n\t\t\t\t\t2012;21:\n\t\t\t\t\t167\u2013172."},{"key":"i1548-1336-49-2-157-b15","series-title":"J Indian Prosthodont Soc","first-page":"189","article-title":"Comparative evaluation of marginal and internal gap of Co-Cr copings fabricated from conventional wax pattern, 3D printed resin pattern and DMLS tech: an in vitro study","volume":"13","author":"Bhaskaran","year":"2013","unstructured":"Bhaskaran\n              E\n            ,\n\t\t\t\t\t\tAzhagarasanNS,\n\t\t\t\t\t\tMiglaniS,\n\t\t\t\t\t\tIlangoT,\n\t\t\t\t\t\tKrishnaGP,\n\t\t\t\t\t\tGajapathiB.\n\t\t\t\t\t\n          Comparative evaluation of marginal and internal gap of Co-Cr copings fabricated from conventional wax pattern, 3D printed resin pattern and DMLS tech: an in vitro study.\n\t\t\t\t\tJ Indian Prosthodont Soc.\n\t\t\t\t\t2013;13:\n\t\t\t\t\t189\u2013195."},{"key":"i1548-1336-49-2-157-b16","series-title":"Marginal discrepancies of Ni\/Cr crowns for a soft tissue-level, trans-mucosal implant system. Clin Oral Implants Res.","author":"Eliopoulos","year":"2013","unstructured":"Eliopoulos\n              D\n            ,\n\t\t\t\t\t\tTorselloF,\n\t\t\t\t\t\tCordaroL.\n\t\t\t\t\t\n          Marginal discrepancies of Ni\/Cr crowns for a soft tissue-level, trans-mucosal implant system. Clin Oral Implants Res.\n          2013;\n\t\t\t\t\t24(suppl A100):82\u201387."},{"key":"i1548-1336-49-2-157-b17","series-title":"Implant Dent","first-page":"299","article-title":"Scanning electron microscope evaluation of vertical and horizontal discrepancy in cast copings for single-tooth implant-supported prostheses","volume":"17","author":"Siadat","year":"2008","unstructured":"Siadat\n              H\n            ,\n\t\t\t\t\t\tAlikhasiM,\n\t\t\t\t\t\tMirfazaelianA,\n\t\t\t\t\t\tZadeMMA.\n\t\t\t\t\t\n          Scanning electron microscope evaluation of vertical and horizontal discrepancy in cast copings for single-tooth implant-supported prostheses.\n\t\t\t\t\tImplant Dent.\n\t\t\t\t\t2008;17:\n\t\t\t\t\t299\u2013308."},{"key":"i1548-1336-49-2-157-b18","series-title":"J Prosthodont","first-page":"419","article-title":"Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs: a literature review","volume":"22","author":"Nawafleh","year":"2013","unstructured":"Nawafleh\n              NA\n            ,\n\t\t\t\t\t\tMackF,\n\t\t\t\t\t\tEvansJ,\n\t\t\t\t\t\tMackayJ,\n\t\t\t\t\t\tHatamlehMM.\n\t\t\t\t\t\n          Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs: a literature review.\n\t\t\t\t\tJ Prosthodont.\n\t\t\t\t\t2013;22:\n\t\t\t\t\t419\u2013428."},{"key":"i1548-1336-49-2-157-b19","series-title":"Br Dent J","first-page":"107","article-title":"The estimation of cement film thickness by an in vivo technique","volume":"131","author":"McLean","year":"1971","unstructured":"McLean\n              JW\n            ,\n\t\t\t\t\t\tvon FraunhoferJA.\n\t\t\t\t\t\n          The estimation of cement film thickness by an in vivo technique.\n\t\t\t\t\tBr Dent J.\n\t\t\t\t\t1971;131:\n\t\t\t\t\t107\u2013111."},{"key":"i1548-1336-49-2-157-b20","series-title":"Dent Mater","first-page":"197","article-title":"The fit of metal-ceramic crowns, a clinical study","volume":"1","author":"Fransson","year":"1985","unstructured":"Fransson\n              B\n            ,\n\t\t\t\t\t\tOiloG,\n\t\t\t\t\t\tGjeitangerR.\n\t\t\t\t\t\n          The fit of metal-ceramic crowns, a clinical study.\n\t\t\t\t\tDent Mater.\n\t\t\t\t\t1985;1:\n\t\t\t\t\t197\u2013199."},{"key":"i1548-1336-49-2-157-b21","series-title":"J Prosthet Dent","first-page":"405","article-title":"Considerations in measurement of marginal fit","volume":"62","author":"Holmes","year":"1989","unstructured":"Holmes\n              JR\n            ,\n\t\t\t\t\t\tBayneSC,\n\t\t\t\t\t\tHollandGA,\n\t\t\t\t\t\tSulikWD.\n\t\t\t\t\t\n          Considerations in measurement of marginal fit.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t1989;62:\n\t\t\t\t\t405\u2013408."},{"key":"i1548-1336-49-2-157-b22","series-title":"J Prosthodont","first-page":"739","article-title":"The effect of milling metal versus milling wax on implant framework retention and adaptation","volume":"28","author":"Ghodsi","year":"2019","unstructured":"Ghodsi\n              S\n            ,\n\t\t\t\t\t\tPirmoazenS,\n\t\t\t\t\t\tBeyabanakiE,\n\t\t\t\t\t\tRostamiM,\n\t\t\t\t\t\tAlikhasiM.\n\t\t\t\t\t\n          The effect of milling metal versus milling wax on implant framework retention and adaptation.\n\t\t\t\t\tJ Prosthodont.\n\t\t\t\t\t2019;28:\n\t\t\t\t\t739\u2013743."},{"key":"i1548-1336-49-2-157-b23","series-title":"Eur J Oral Sci","first-page":"272","article-title":"Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures","volume":"116","author":"Wettstein","year":"2008","unstructured":"Wettstein\n              F\n            ,\n\t\t\t\t\t\tSailerI,\n\t\t\t\t\t\tRoosM,\n\t\t\t\t\t\tHammerleCH.\n\t\t\t\t\t\n          Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures.\n\t\t\t\t\tEur J Oral Sci.\n\t\t\t\t\t2008;116:\n\t\t\t\t\t272\u2013279."},{"key":"i1548-1336-49-2-157-b24","series-title":"J Dent","first-page":"118","article-title":"Comparison the marginal and internal fit of metal copings cast from wax patterns fabricated by CAD\/CAM and conventional wax up techniques","volume":"14","author":"Vojdani","year":"2013","unstructured":"Vojdani\n              M\n            ,\n\t\t\t\t\t\tTorabiK,\n\t\t\t\t\t\tFarjoodE,\n\t\t\t\t\t\tKhalediA.\n\t\t\t\t\t\n          Comparison the marginal and internal fit of metal copings cast from wax patterns fabricated by CAD\/CAM and conventional wax up techniques.\n\t\t\t\t\tJ Dent.\n\t\t\t\t\t2013;14:\n\t\t\t\t\t118."},{"key":"i1548-1336-49-2-157-b25","series-title":"Quintessence Int","first-page":"555","article-title":"Effect of intraoral scanning on the passivity of fit of implant-supported fixed dental prostheses","volume":"43","author":"Karl","year":"2012","unstructured":"Karl\n              M\n            ,\n\t\t\t\t\t\tGraefF,\n\t\t\t\t\t\tSchubinskiP,\n\t\t\t\t\t\tTaylorT.\n\t\t\t\t\t\n          Effect of intraoral scanning on the passivity of fit of implant-supported fixed dental prostheses.\n\t\t\t\t\tQuintessence Int.\n\t\t\t\t\t2012:\n\t\t\t\t\t43:\n\t\t\t\t\t555\u2013562."},{"key":"i1548-1336-49-2-157-b26","series-title":"Clin Oral Implants Res","first-page":"772","article-title":"Evaluation of the marginal precision of one-piece complete arch titanium frameworks fabricated using five different methods for implant-supported restorations","volume":"19","author":"Torsello","year":"2008","unstructured":"Torsello\n              F\n            ,\n\t\t\t\t\t\tTorresantoD,\n\t\t\t\t\t\tMirisolaV,\n\t\t\t\t\t\tErcoliC,\n\t\t\t\t\t\tCordaroL.\n\t\t\t\t\t\n          Evaluation of the marginal precision of one-piece complete arch titanium frameworks fabricated using five different methods for implant-supported restorations.\n\t\t\t\t\tClin Oral Implants Res.\n\t\t\t\t\t2008;19:\n\t\t\t\t\t772\u2013779."},{"key":"i1548-1336-49-2-157-b27","series-title":"Clin Oral Implants Res","first-page":"343","article-title":"Comparative evaluation of casting retention using the ITI solid abutment with six cements","volume":"13","author":"Mansour","year":"2002","unstructured":"Mansour\n              A\n            ,\n\t\t\t\t\t\tErcoliC,\n\t\t\t\t\t\tGraserG,\n\t\t\t\t\t\tTallentsR,\n\t\t\t\t\t\tMossM.\n\t\t\t\t\t\n          Comparative evaluation of casting retention using the ITI solid abutment with six cements.\n\t\t\t\t\tClin Oral Implants Res.\n\t\t\t\t\t2002;13:\n\t\t\t\t\t343\u2013348."},{"key":"i1548-1336-49-2-157-b28","series-title":"J Prosthodont","first-page":"20","article-title":"In vivo stress behavior in cemented and screw-retained five-unit implant FPDs","volume":"15","author":"Karl","year":"2006","unstructured":"Karl\n              M\n            ,\n\t\t\t\t\t\tTaylorTD,\n\t\t\t\t\t\tWichmannMG,\n\t\t\t\t\t\tHeckmannSM.\n\t\t\t\t\t\n          In vivo stress behavior in cemented and screw-retained five-unit implant FPDs.\n\t\t\t\t\tJ Prosthodont.\n\t\t\t\t\t2006;15:\n\t\t\t\t\t20\u201324."},{"key":"i1548-1336-49-2-157-b29","series-title":"Dent Mater","first-page":"102","article-title":"Application of laser measuring, numerical simulation and rapid prototyping to titanium dental castings","volume":"17","author":"Wu","year":"2001","unstructured":"Wu\n              M\n            ,\n\t\t\t\t\t\tTinschertJ,\n\t\t\t\t\t\tAugthunM,\n\t\t\t\t\t\tet al.\n\t\t\t\t\t\n          Application of laser measuring, numerical simulation and rapid prototyping to titanium dental castings.\n\t\t\t\t\tDent Mater.\n\t\t\t\t\t2001;17:\n\t\t\t\t\t102\u2013108."},{"key":"i1548-1336-49-2-157-b30","series-title":"J Prosthodont","first-page":"146","article-title":"Additive manufacturing technologies used for processing polymers: current status and potential application in prosthetic dentistry","volume":"28","author":"Revilla-Leon","year":"2019","unstructured":"Revilla-Leon\n              M\n            ,\n\t\t\t\t\t\t\u00d6zcanM.\n\t\t\t\t\t\n          Additive manufacturing technologies used for processing polymers: current status and potential application in prosthetic dentistry.\n\t\t\t\t\tJ Prosthodont.\n\t\t\t\t\t2019;28:\n\t\t\t\t\t146\u2013158."},{"key":"i1548-1336-49-2-157-b31","series-title":"J Prosthet Dent","first-page":"47","article-title":"Marginal accuracy of titanium copings fabricated by casting and CAD\/CAM techniques","volume":"96","author":"Witkowski","year":"2006","unstructured":"Witkowski\n              S\n            ,\n\t\t\t\t\t\tKomineF,\n\t\t\t\t\t\tGerdsT.\n\t\t\t\t\t\n          Marginal accuracy of titanium copings fabricated by casting and CAD\/CAM techniques.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2006;96:\n\t\t\t\t\t47\u201352."},{"key":"i1548-1336-49-2-157-b32","series-title":"J Prosthet Dent","first-page":"378","article-title":"A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation","volume":"102","author":"Gonzalo","year":"2009","unstructured":"Gonzalo\n              E\n            ,\n\t\t\t\t\t\tSu\u00e1rezMJ,\n\t\t\t\t\t\tSerranoB,\n\t\t\t\t\t\tLozanoJF.\n\t\t\t\t\t\n          A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2009;102:\n\t\t\t\t\t378\u2013384."},{"key":"i1548-1336-49-2-157-b33","series-title":"J Prosthodont","first-page":"378","article-title":"An in vitro comparison of vertical marginal gaps of CAD\/CAM titanium and conventional cast restorations","volume":"17","author":"Tan","year":"2008","unstructured":"Tan\n              PL\n            ,\n\t\t\t\t\t\tGrattonDG,\n\t\t\t\t\t\tDiaz-ArnoldAM,\n\t\t\t\t\t\tHolmesDC.\n\t\t\t\t\t\n          An in vitro comparison of vertical marginal gaps of CAD\/CAM titanium and conventional cast restorations.\n\t\t\t\t\tJ Prosthodont.\n\t\t\t\t\t2008;17:\n\t\t\t\t\t378\u2013383."},{"key":"i1548-1336-49-2-157-b34","series-title":"J Prosthet Dent","first-page":"191","article-title":"Marginal accuracy and internal fit of machine-milled and cast titanium crowns","volume":"106","author":"Han","year":"2011","unstructured":"Han\n              H-S\n            ,\n\t\t\t\t\t\tYangH-S,\n\t\t\t\t\t\tLimH-P,\n\t\t\t\t\t\tParkY-J.\n\t\t\t\t\t\n          Marginal accuracy and internal fit of machine-milled and cast titanium crowns.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2011;106:\n\t\t\t\t\t191\u2013197."},{"key":"i1548-1336-49-2-157-b35","series-title":"Eur J Oral Sci","first-page":"174","article-title":"Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD\/CAM systems","volume":"113","author":"Reich","year":"2005","unstructured":"Reich\n              S\n            ,\n\t\t\t\t\t\tWichmannM,\n\t\t\t\t\t\tNkenkeE,\n\t\t\t\t\t\tProeschelP.\n\t\t\t\t\t\n          Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD\/CAM systems.\n\t\t\t\t\tEur J Oral Sci.\n\t\t\t\t\t2005;113:\n\t\t\t\t\t174\u2013179."},{"key":"i1548-1336-49-2-157-b36","series-title":"J Prosthet Dent","first-page":"216","article-title":"Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system","volume":"104","author":"Baig","year":"2010","unstructured":"Baig\n              MR\n            ,\n\t\t\t\t\t\tTanKB-C,\n\t\t\t\t\t\tNichollsJI.\n\t\t\t\t\t\n          Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2010;104:\n\t\t\t\t\t216\u2013227."},{"key":"i1548-1336-49-2-157-b37","series-title":"J Indian Prosthodont Soc","first-page":"3","article-title":"A comparative evaluation of the marginal adaptation of a thermoplastic resin, a light cured wax and an inlay casting wax on stone dies: an in vitro study","volume":"18","author":"Gopalan","year":"2018","unstructured":"Gopalan\n              RP\n            ,\n\t\t\t\t\t\tNairVV,\n\t\t\t\t\t\tHarshakumarK,\n\t\t\t\t\t\tRavichandranR,\n\t\t\t\t\t\tLylajamS,\n\t\t\t\t\t\tViswambaranP.\n\t\t\t\t\t\n          A comparative evaluation of the marginal adaptation of a thermoplastic resin, a light cured wax and an inlay casting wax on stone dies: an in vitro study.\n\t\t\t\t\tJ Indian Prosthodont Soc.\n\t\t\t\t\t2018;18:\n\t\t\t\t\t3\u20139."},{"key":"i1548-1336-49-2-157-b38","series-title":"J Prosthet Dent","first-page":"164","article-title":"Marginal and internal fit of metal copings fabricated with rapid prototyping and conventional waxing","volume":"117","author":"Farjood","year":"2017","unstructured":"Farjood\n              E\n            ,\n\t\t\t\t\t\tVojdaniM,\n\t\t\t\t\t\tTorabiK,\n\t\t\t\t\t\tKhalediAAR.\n\t\t\t\t\t\n          Marginal and internal fit of metal copings fabricated with rapid prototyping and conventional waxing.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2017;117:\n\t\t\t\t\t164\u2013170."},{"key":"i1548-1336-49-2-157-b39","series-title":"J Adv Prosthodont","first-page":"176","article-title":"Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography","volume":"9","author":"Kim","year":"2017","unstructured":"Kim\n              DY\n            ,\n\t\t\t\t\t\tKimCM,\n\t\t\t\t\t\tKimJH.\n\t\t\t\t\t\n          Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography.\n\t\t\t\t\tJ Adv Prosthodont.\n\t\t\t\t\t2017;9:\n\t\t\t\t\t176\u2013181."},{"key":"i1548-1336-49-2-157-b40","series-title":"J Prosthet Dent","first-page":"49","article-title":"Fit of pressed crowns fabricated from two CAD-CAM wax pattern process plans: a comparative in vitro study","volume":"118","author":"Shamseddine","year":"2017","unstructured":"Shamseddine\n              L\n            ,\n\t\t\t\t\t\tMortadaR,\n\t\t\t\t\t\tRifaiK,\n\t\t\t\t\t\tChidiacJJ.\n\t\t\t\t\t\n          Fit of pressed crowns fabricated from two CAD-CAM wax pattern process plans: a comparative in vitro study.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2017;118:\n\t\t\t\t\t49\u201354."},{"key":"i1548-1336-49-2-157-b41","series-title":"J Prosthet Dent","first-page":"242","article-title":"Marginal and internal fit of pressed ceramic crowns made from conventional and computer-aided design and computer-aided manufacturing wax patterns: an in vitro comparison","volume":"116","author":"Shamseddine","year":"2016","unstructured":"Shamseddine\n              L\n            ,\n\t\t\t\t\t\tMortadaR,\n\t\t\t\t\t\tRifaiK,\n\t\t\t\t\t\tChidiacJJ.\n\t\t\t\t\t\n          Marginal and internal fit of pressed ceramic crowns made from conventional and computer-aided design and computer-aided manufacturing wax patterns: an in vitro comparison.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2016;116:\n\t\t\t\t\t242\u2013248."},{"key":"i1548-1336-49-2-157-b42","series-title":"Dent Mater","first-page":"681","article-title":"Novel method for titanium crown casting using a combination of wax patterns fabricated by a CAD\/CAM system and a non-expanded investment","volume":"22","author":"Zhang","year":"2006","unstructured":"Zhang\n              Z\n            ,\n\t\t\t\t\t\tTamakiY,\n\t\t\t\t\t\tHottaY,\n\t\t\t\t\t\tMiyazakiT.\n\t\t\t\t\t\n          Novel method for titanium crown casting using a combination of wax patterns fabricated by a CAD\/CAM system and a non-expanded investment.\n\t\t\t\t\tDent Mater.\n\t\t\t\t\t2006;22:\n\t\t\t\t\t681\u2013687."},{"key":"i1548-1336-49-2-157-b43","series-title":"J Prosthet Dent","first-page":"95","article-title":"Effect of production method on surface roughness, marginal and internal fit, and retention of cobalt-chromium single crowns","volume":"118","author":"L\u00f6vgren","year":"2017","unstructured":"L\u00f6vgren\n              N\n            ,\n\t\t\t\t\t\tRoxnerR,\n\t\t\t\t\t\tKlemendzS,\n\t\t\t\t\t\tLarssonC.\n\t\t\t\t\t\n          Effect of production method on surface roughness, marginal and internal fit, and retention of cobalt-chromium single crowns.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2017;118:\n\t\t\t\t\t95\u2013101."},{"key":"i1548-1336-49-2-157-b44","series-title":"Dent Mater","first-page":"356","article-title":"The fit of cobalt\u2013chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study","volume":"27","author":"\u00d6rtorp","year":"2011","unstructured":"\u00d6rtorp\n              A\n            ,\n\t\t\t\t\t\tJ\u00f6nssonD,\n\t\t\t\t\t\tMouhsenA,\n\t\t\t\t\t\tvon SteyernPV.\n\t\t\t\t\t\n          The fit of cobalt\u2013chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study.\n\t\t\t\t\tDent Mater.\n\t\t\t\t\t2011;27:\n\t\t\t\t\t356\u2013363."},{"key":"i1548-1336-49-2-157-b45","series-title":"Dent Mater","first-page":"174","article-title":"Evaluation of marginal and internal fit of ceramic crown copings","volume":"29","author":"Colpani","year":"2013","unstructured":"Colpani\n              JT\n            ,\n\t\t\t\t\t\tBorbaM,\n\t\t\t\t\t\tDella Bona\u00c1.\n\t\t\t\t\t\n          Evaluation of marginal and internal fit of ceramic crown copings.\n\t\t\t\t\tDent Mater.\n\t\t\t\t\t2013;29:\n\t\t\t\t\t174\u2013180."},{"key":"i1548-1336-49-2-157-b46","series-title":"J Oral Implantol","first-page":"417","article-title":"Marginal fit of implant-supported all-ceramic zirconia frameworks","volume":"39","author":"Zaghloul","year":"2013","unstructured":"Zaghloul\n              HH\n            ,\n\t\t\t\t\t\tYounisJF.\n\t\t\t\t\t\n          Marginal fit of implant-supported all-ceramic zirconia frameworks.\n\t\t\t\t\tJ Oral Implantol.\n\t\t\t\t\t2013;39:\n\t\t\t\t\t417\u2013424."},{"key":"i1548-1336-49-2-157-b47","series-title":"Contemporary Fixed Prosthodontics. 4th ed","first-page":"372","author":"Rosenstiel","year":"2006","unstructured":"Rosenstiel\n              S\n            ,\n\t\t\t\t\t\tMartinF,\n\t\t\t\t\t\tFujimotoJ.\n\t\t\t\t\t\n          \n            Contemporary Fixed Prosthodontics. 4th ed.\n\t\t\t\t\tSt. Louis, MO:\n\t\t\t\t\tMosby, Inc;2006:\n\t\t\t\t\t372\u2013373."},{"key":"i1548-1336-49-2-157-b48","series-title":"J Prosthet Dent","first-page":"344","article-title":"Fit of crown wax patterns after removal from the die","volume":"53","author":"Zeltser","year":"1985","unstructured":"Zeltser\n              C\n            ,\n\t\t\t\t\t\tLewinsteinI,\n\t\t\t\t\t\tGrajowerR.\n\t\t\t\t\t\n          Fit of crown wax patterns after removal from the die.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t1985;53:\n\t\t\t\t\t344\u2013346."},{"key":"i1548-1336-49-2-157-b49","series-title":"Oper Dent","first-page":"486","article-title":"The accuracy of optical scanning: influence of convergence and die preparation","volume":"36","author":"Chan","year":"2011","unstructured":"Chan\n              DC\n            ,\n\t\t\t\t\t\tChungAK,\n\t\t\t\t\t\tHainesJ,\n\t\t\t\t\t\tYauEH,\n\t\t\t\t\t\tKuoCC.\n\t\t\t\t\t\n          The accuracy of optical scanning: influence of convergence and die preparation.\n\t\t\t\t\tOper Dent.\n\t\t\t\t\t2011;36:\n\t\t\t\t\t486\u2013491."},{"key":"i1548-1336-49-2-157-b50","series-title":"Int J Dent","first-page":"783948","article-title":"Trends in computer-aided manufacturing in prosthodontics: a review of the available streams","volume":"2014","author":"Abduo","year":"2014","unstructured":"Abduo\n              J\n            ,\n\t\t\t\t\t\tLyonsK,\n\t\t\t\t\t\tBennamounM.\n\t\t\t\t\t\n          Trends in computer-aided manufacturing in prosthodontics: a review of the available streams.\n\t\t\t\t\tInt J Dent.\n\t\t\t\t\t2014;2014:\n\t\t\t\t\t783948."},{"key":"i1548-1336-49-2-157-b51","series-title":"J Prosthet Dent","first-page":"594","article-title":"Marginal fit of castable ceramic crowns","volume":"67","author":"Holmes","year":"1992","unstructured":"Holmes\n              JR\n            ,\n\t\t\t\t\t\tSulikWD,\n\t\t\t\t\t\tHollandGA,\n\t\t\t\t\t\tBayneSC.\n\t\t\t\t\t\n          Marginal fit of castable ceramic crowns.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t1992;67:\n\t\t\t\t\t594\u2013599."},{"key":"i1548-1336-49-2-157-b52","series-title":"Clin Implant Dent Related Res","first-page":"218","article-title":"Marginal adaptation of all-ceramic crowns on implant abutments","volume":"10","author":"Att","year":"2008","unstructured":"Att\n              W\n            ,\n\t\t\t\t\t\tHoischenT,\n\t\t\t\t\t\tGerdsT,\n\t\t\t\t\t\tStrubJR.\n\t\t\t\t\t\n          Marginal adaptation of all-ceramic crowns on implant abutments.\n\t\t\t\t\tClin Implant Dent Related Res.\n\t\t\t\t\t2008;10:\n\t\t\t\t\t218\u2013225."},{"key":"i1548-1336-49-2-157-b53","series-title":"Dent Res J","first-page":"13","article-title":"Retentiveness of implant-supported metal copings using different luting agents","volume":"9","author":"Nejatidanesh","year":"2012","unstructured":"Nejatidanesh\n              F\n            ,\n\t\t\t\t\t\tSavabiO,\n\t\t\t\t\t\tEbrahimiM,\n\t\t\t\t\t\tSavabiG.\n\t\t\t\t\t\n          Retentiveness of implant-supported metal copings using different luting agents.\n\t\t\t\t\tDent Res J.\n\t\t\t\t\t2012;9:\n\t\t\t\t\t13."},{"key":"i1548-1336-49-2-157-b54","series-title":"J Oral Rehabil","first-page":"582","article-title":"Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth","volume":"26","author":"Beschnidt","year":"1999","unstructured":"Beschnidt\n              SM\n            ,\n\t\t\t\t\t\tStrubJR.\n\t\t\t\t\t\n          Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth.\n\t\t\t\t\tJ Oral Rehabil.\n\t\t\t\t\t1999;26:\n\t\t\t\t\t582\u2013593."},{"key":"i1548-1336-49-2-157-b55","series-title":"Int J Prosthodont","first-page":"587","article-title":"Clinical evaluation of marginal fit of a new experimental all-ceramic system before and after cementation","volume":"16","author":"Wolfart","year":"2003","unstructured":"Wolfart\n              S\n            ,\n\t\t\t\t\t\tWegnerSM,\n\t\t\t\t\t\tAl-HalabiA,\n\t\t\t\t\t\tKernM.\n\t\t\t\t\t\n          Clinical evaluation of marginal fit of a new experimental all-ceramic system before and after cementation.\n\t\t\t\t\tInt J Prosthodont.\n\t\t\t\t\t2003;16:\n\t\t\t\t\t587\u2013592."},{"key":"i1548-1336-49-2-157-b56","series-title":"J Prosthet Dent","first-page":"909","article-title":"Clinical marginal and internal adaptation of CAD\/CAM milling, laser sintering, and cast metal ceramic crowns","volume":"112","author":"Tamac","year":"2014","unstructured":"Tamac\n              E\n            ,\n\t\t\t\t\t\tToksavulS,\n\t\t\t\t\t\tTomanM.\n\t\t\t\t\t\n          Clinical marginal and internal adaptation of CAD\/CAM milling, laser sintering, and cast metal ceramic crowns.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2014;112:\n\t\t\t\t\t909\u2013913."},{"key":"i1548-1336-49-2-157-b57","series-title":"J Prosthet Dent","first-page":"623","article-title":"Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology","volume":"113","author":"Huang","year":"2015","unstructured":"Huang\n              Z\n            ,\n\t\t\t\t\t\tZhangL,\n\t\t\t\t\t\tZhuJ,\n\t\t\t\t\t\tZhangX.\n\t\t\t\t\t\n          Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2015;113:\n\t\t\t\t\t623\u2013627."},{"key":"i1548-1336-49-2-157-b58","series-title":"J Prosthet Dent","first-page":"545","article-title":"Marginal adaptation and CAD-CAM technology: a systematic review of restorative material and fabrication techniques","volume":"119","author":"Papadiochou","year":"2018","unstructured":"Papadiochou\n              S\n            ,\n\t\t\t\t\t\tPissiotisAL.\n\t\t\t\t\t\n          Marginal adaptation and CAD-CAM technology: a systematic review of restorative material and fabrication techniques.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2018;119:\n\t\t\t\t\t545\u2013551."},{"key":"i1548-1336-49-2-157-b59","series-title":"J Dent Shiraz Univ Med Sci","first-page":"1","article-title":"Rapid prototyping technologies and their applications in prosthodontics, a review of literature","volume":"1","author":"Torabi","year":"2014","unstructured":"Torabi\n              K\n            ,\n\t\t\t\t\t\tFarjoodE,\n\t\t\t\t\t\tHamedaniS.\n\t\t\t\t\t\n          Rapid prototyping technologies and their applications in prosthodontics, a review of literature.\n\t\t\t\t\tJ Dent Shiraz Univ Med Sci.\n\t\t\t\t\t2014;1:\n\t\t\t\t\t1\u20139."},{"key":"i1548-1336-49-2-157-b60","series-title":"Int J Oral Maxillofac Implants","first-page":"381","article-title":"Evaluation of retention of cemented laser-sintered crowns on unmodified straight narrow implant abutments","volume":"28","author":"Kilicarslan","year":"2013","unstructured":"Kilicarslan\n              MA\n            ,\n\t\t\t\t\t\tOzkanP.\n\t\t\t\t\t\n          Evaluation of retention of cemented laser-sintered crowns on unmodified straight narrow implant abutments.\n\t\t\t\t\tInt J Oral Maxillofac Implants.\n\t\t\t\t\t2013;28:\n\t\t\t\t\t381\u2013387."},{"key":"i1548-1336-49-2-157-b61","series-title":"Int J Oral Maxillofac Implants","first-page":"719","article-title":"Cement-retained versus screw-retained implant restorations: a critical review","volume":"18","author":"Michalakis","year":"2002","unstructured":"Michalakis\n              KX\n            ,\n\t\t\t\t\t\tHirayamaH,\n\t\t\t\t\t\tGarefisPD.\n\t\t\t\t\t\n          Cement-retained versus screw-retained implant restorations: a critical review.\n\t\t\t\t\tInt J Oral Maxillofac Implants.\n\t\t\t\t\t2002;18:\n\t\t\t\t\t719\u2013728."},{"key":"i1548-1336-49-2-157-b62","series-title":"J Dent","first-page":"123","article-title":"Vertical discrepancy and microleakage of laser-sintered and vacuum-cast implant-supported structures luted with different cement types","volume":"40","author":"Oyag\u00fce","year":"2012","unstructured":"Oyag\u00fce\n              RC\n            ,\n\t\t\t\t\t\tS\u00e1nchez-Turri\u00f3nA,\n\t\t\t\t\t\tL\u00f3pez-LozanoJF,\n\t\t\t\t\t\tSu\u00e1rez-Garc\u00edaM.\n\t\t\t\t\t\n          Vertical discrepancy and microleakage of laser-sintered and vacuum-cast implant-supported structures luted with different cement types.\n\t\t\t\t\tJ Dent.\n\t\t\t\t\t2012;40:\n\t\t\t\t\t123\u2013130."},{"key":"i1548-1336-49-2-157-b63","series-title":"J Contemp Dent Pract","first-page":"801","article-title":"Microleakage of glass ionomer-based provisional cement in CAD\/CAM-fabricated interim crowns: an in vitro study","volume":"17","author":"Farah","year":"2016","unstructured":"Farah\n              RI\n            ,\n\t\t\t\t\t\tAl-HarethiN.\n\t\t\t\t\t\n          Microleakage of glass ionomer-based provisional cement in CAD\/CAM-fabricated interim crowns: an in vitro study.\n\t\t\t\t\tJ Contemp Dent Pract.\n\t\t\t\t\t2016;17:\n\t\t\t\t\t801\u2013806."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/49\/2\/article-p157.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/joi\/article-pdf\/49\/2\/157\/3212970\/i1548-1336-49-2-157.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/49\/2\/article-p157.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/49\/2\/article-p157.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T00:19:27Z","timestamp":1752193167000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/49\/2\/article-p157.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4]]},"references-count":63,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-20-00069","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"value":"1548-1336","type":"electronic"},{"value":"0160-6972","type":"print"}],"subject":[],"published":{"date-parts":[[2023,4]]}}}