{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T03:16:38Z","timestamp":1787022998930,"version":"build-2736575974"},"reference-count":55,"publisher":"American Academy of Implant Dentistry","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2022,6]]},"abstract":"<jats:p>\n                    Subcrestal placement of implants may have interproximal bone proximity issues that interfere with the submucosal contour of implant-supported zirconia restorations during delivery of the restorations. Modification of the mesial distal submucosal areas may be necessary to fully seat the restoration without impingement of the interproximal bone. Our aim was to determine if modification of submucosal cervical contour of implant supported zirconia-titanium base (Zi-Ti base) restorations resulted in a significant change in fracture strength compared with Zi-Ti base restorations without any modification near the cervical submucosal area. Implant Zi-Ti base restorations designed in the form of a maxillary premolar were made for the Straumann implant lab analog. Zirconia samples were cemented onto the Ti-base and the test group (N = 20) underwent recontouring and polishing at the junction of the Zi-Ti base cervical areas. The control group (N = 20) did not undergo any modifications. All 40 samples underwent fracture testing with an Instron machine. We assessed differences between modified and unmodified implants restorations using a 2-tailed\n                    <jats:italic>t<\/jats:italic>\n                    test for independent samples. Fracture strength values (N) ranged from 4354.68 to 6412.49 in the test group (N = 20) and from 5400.31 to 6953.22 in the control group (N = 20). The average fracture strength in the control group (6154.84 \u00b1 320.50) was higher than in the modified group (5593.13 \u00b1 486.51;\n                    <jats:italic>P<\/jats:italic>\n                    &lt; .001). Modification of submucosal contour significantly decreased fracture strength. However, the average fracture strength exceeded the masticatory forces of humans.\n                  <\/jats:p>","DOI":"10.1563\/aaid-joi-d-20-00144","type":"journal-article","created":{"date-parts":[[2021,5,4]],"date-time":"2021-05-04T15:18:28Z","timestamp":1620141508000},"page":"202-209","source":"Crossref","is-referenced-by-count":1,"title":["Evaluation of Fracture Resistance of Zirconia Modification\/Polishing Around Implant Abutments"],"prefix":"10.1563","volume":"48","author":[{"given":"Cheryl J.","family":"Park","sequence":"first","affiliation":[{"name":"Division of Restorative Sciences, Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, California."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jenny Jin","family":"Son","sequence":"additional","affiliation":[{"name":"Division of Restorative Sciences, Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, California."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard","family":"Lin","sequence":"additional","affiliation":[{"name":"Division of Restorative Sciences, Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, California."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin-Ho","family":"Phark","sequence":"additional","affiliation":[{"name":"Division of Restorative Sciences, Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, California."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Melissa L.","family":"Wilson","sequence":"additional","affiliation":[{"name":"University of Southern California KECK School of Medicine, Los Angeles, California."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Winston W.","family":"Chee","sequence":"additional","affiliation":[{"name":"Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, California."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George","family":"Cho","sequence":"additional","affiliation":[{"name":"Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, California."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"434","reference":[{"key":"i1548-1336-48-3-202-b01","series-title":"Phillips' Science of Dental Materials. 11th ed","first-page":"759","article-title":"Dental implants","author":"Esquivel-Upshaw","year":"2003","unstructured":"Esquivel-Upshaw\n              J.\n            \n          \n          Dental implants.\n\t\t\t\t\tIn:AnuasaviceKJ,ed.Phillips' Science of Dental Materials. 11th ed.\n\t\t\t\t\tMissouri:\n\t\t\t\t\tSaunders Elsevier;2003:\n\t\t\t\t\t759\u2013781."},{"key":"i1548-1336-48-3-202-b02","series-title":"Biomaterials","first-page":"73","article-title":"Implant-fixed, dental bridges from carbon\/graphite fibre reinforced poly(methyl methacrylate)","volume":"7","author":"Bjork","year":"1986","unstructured":"Bjork\n              N,\n            \n            \n              Ekstrand\n              K,\n            \n            \n              Ruyter\n              IE.\n            \n          \n          Implant-fixed, dental bridges from carbon\/graphite fibre reinforced poly(methyl methacrylate).\n\t\t\t\t\tBiomaterials.\n\t\t\t\t\t1986;7:73\u201375."},{"key":"i1548-1336-48-3-202-b03","series-title":"Scand J Plast Reconstr Surg Suppl","first-page":"1","article-title":"Osseointegrated implants in the treatment of the edentulous jaw: experience from a 10-year period","volume":"16","author":"Br\u00e5nemark","year":"1977","unstructured":"Br\u00e5nemark\n              PI,\n            \n            \n              Hansson\n              BO,\n            \n            \n              Adell\n              R,\n            \n            \n              Breine\n              U,\n            \n            \n              Lindstr\u00f6m\n              J,\n            \n            \n              Hall\u00e9n\n              O.\n            \n          \n          Osseointegrated implants in the treatment of the edentulous jaw: experience from a 10-year period.\n\t\t\t\t\tScand J Plast Reconstr Surg Suppl.\n\t\t\t\t\t1977;16:1\u2013132."},{"key":"i1548-1336-48-3-202-b04","series-title":"Int J Oral Surg","first-page":"387","article-title":"15-year study of osseointegrated implants in the treatment of the edentulous jaw","volume":"10","author":"Adell","year":"1981","unstructured":"Adell\n              R,\n            \n            \n              Lekholm\n              U,\n            \n            \n              Rockler\n              B,\n            \n            \n              Br\u00e5nemark\n              PI. A\n            \n          \n          15-year study of osseointegrated implants in the treatment of the edentulous jaw.\n\t\t\t\t\tInt J Oral Surg.\n\t\t\t\t\t1981;10:387\u2013416."},{"key":"i1548-1336-48-3-202-b05","series-title":"Int J Prosthodont","first-page":"415","article-title":"Implant-supported laser-welded titanium and conventional cast frameworks in the partially edentulous law: a 5-year prospective multicenter study","volume":"16","author":"Jemt","year":"2003","unstructured":"Jemt\n              T,\n            \n            \n              Henry\n              P,\n            \n            \n              Lind\u00e9n\n              B,\n            \n            \n              Naert\n              I,\n            \n            \n              Weber\n              H,\n            \n            \n              Wendelhag\n              I.\n            \n          \n          Implant-supported laser-welded titanium and conventional cast frameworks in the partially edentulous law: a 5-year prospective multicenter study.\n\t\t\t\t\tInt J Prosthodont.\n\t\t\t\t\t2003;16:415\u2013421."},{"key":"i1548-1336-48-3-202-b06","series-title":"Clin Oral Impl Res","first-page":"853","article-title":"Dental implant suprastructures using cobalt\u2013chromium alloy compared with gold alloy framework veneered with ceramic or acrylic resin: a retrospective cohort study up to 18 years","volume":"23","author":"Teigen","year":"2012","unstructured":"Teigen\n              K,\n            \n            \n              Jokstad\n              A.\n            \n          \n          Dental implant suprastructures using cobalt\u2013chromium alloy compared with gold alloy framework veneered with ceramic or acrylic resin: a retrospective cohort study up to 18 years.\n\t\t\t\t\tClin Oral Impl Res.\n\t\t\t\t\t2012;23:853\u2013860."},{"key":"i1548-1336-48-3-202-b07","series-title":"Clin Oral Implants Res","first-page":"172","article-title":"Accuracy of implant-supported prostheses in the edentulous jaw: analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three-dimensional photogrammetric technique","volume":"6","author":"Jemt","year":"1995","unstructured":"Jemt\n              T,\n            \n            \n              Lie\n              A.\n            \n          \n          Accuracy of implant-supported prostheses in the edentulous jaw: analysis of precision of fit between cast gold-alloy frameworks and master casts by means of a three-dimensional photogrammetric technique.\n\t\t\t\t\tClin Oral Implants Res.\n\t\t\t\t\t1995;6:172\u2013180."},{"key":"i1548-1336-48-3-202-b08","series-title":"Clin Oral Impl Res","first-page":"625","article-title":"A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years I. Implant-supported FPDs","volume":"15","author":"Pjetursson","year":"2004","unstructured":"Pjetursson\n              B,\n            \n            \n              Tan\n              K,\n            \n            \n              Lang\n              N,\n            \n            \n              Bragger\n              U,\n            \n            \n              Egger\n              M,\n            \n            \n              Zwahlen\n              M.\n            \n          \n          A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years I. Implant-supported FPDs.\n\t\t\t\t\tClin Oral Impl Res.\n\t\t\t\t\t2004;15:625\u2013642."},{"key":"i1548-1336-48-3-202-b09","series-title":"Dent Mater J","first-page":"44","article-title":"A review of dental CAD\/CAM: current status and future perspectives from 20 years of experience","volume":"28","author":"Miyazaki","year":"2009","unstructured":"Miyazaki\n              T,\n            \n            \n              Hotta\n              Y,\n            \n            \n              Kunii\n              J,\n            \n            \n              Kuriyama\n              S,\n            \n            \n              Tamaki\n              Y.\n            \n          \n          A review of dental CAD\/CAM: current status and future perspectives from 20 years of experience.\n\t\t\t\t\tDent Mater J.\n\t\t\t\t\t2009;28:44\u201356."},{"key":"i1548-1336-48-3-202-b10","series-title":"J Dent","first-page":"819","article-title":"An overview of zirconia ceramics: basic properties and clinical applications","volume":"35","author":"Manicone","year":"2007","unstructured":"Manicone\n              PF,\n            \n            \n              Rossi Iommetti\n              P,\n            \n            \n              Raffaelli\n              L.\n            \n          \n          An overview of zirconia ceramics: basic properties and clinical applications.\n\t\t\t\t\tJ Dent.\n\t\t\t\t\t2007;35:819\u2013826."},{"issue":"(suppl 4)","key":"i1548-1336-48-3-202-b11","series-title":"Clin Oral Implants Res","first-page":"4","article-title":"A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions","volume":"20","author":"Sailer","year":"2009","unstructured":"Sailer\n              I,\n            \n            \n              Philipp\n              A,\n            \n            \n              Zembic\n              A,\n            \n            \n              Pjetursson\n              BE,\n            \n            \n              Hammerle\n              CH,\n            \n            \n              Zwahlen\n              M.\n            \n          \n          A systematic review of the performance of ceramic and metal implant abutments supporting fixed implant reconstructions.\n\t\t\t\t\tClin Oral Implants Res.\n\t\t\t\t\t2009;20(suppl 4):\n\t\t\t\t\t4\u201331."},{"key":"i1548-1336-48-3-202-b12","series-title":"Int J Prosthodont","first-page":"553","article-title":"Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up","volume":"22","author":"Sailer","year":"2009","unstructured":"Sailer\n              I,\n            \n            \n              Gottnerb\n              J,\n            \n            \n              Kanelb\n              S,\n            \n            \n              Hammerle\n              CHF.\n            \n          \n          Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: a 3-year follow-up.\n\t\t\t\t\tInt J Prosthodont.\n\t\t\t\t\t2009;22:553\u2013560."},{"key":"i1548-1336-48-3-202-b13","series-title":"J Periodontol","first-page":"2065","article-title":"Zirconium dioxide implant abutments for posterior single- tooth replacement: first results","volume":"80","author":"Nothdurft","year":"2009","unstructured":"Nothdurft\n              FP,\n            \n            \n              Pospiech\n              PR.\n            \n          \n          Zirconium dioxide implant abutments for posterior single- tooth replacement: first results.\n\t\t\t\t\tJ Periodontol.\n\t\t\t\t\t2009;80:2065\u20132072."},{"key":"i1548-1336-48-3-202-b14","series-title":"Int J Prosthodont","first-page":"555","article-title":"Five-year follow-up of implant-supported y-tzp and zta fixed dental prostheses. A randomized, prospective clinical trial comparing two different material systems","volume":"23","author":"Larsson","year":"2010","unstructured":"Larsson\n              C,\n            \n            \n              Vult von Steyern\n              P.\n            \n          \n          Five-year follow-up of implant-supported y-tzp and zta fixed dental prostheses. A randomized, prospective clinical trial comparing two different material systems.\n\t\t\t\t\tInt J Prosthodont.\n\t\t\t\t\t2010;23:555\u2013561."},{"key":"i1548-1336-48-3-202-b15","series-title":"Int J Prosthodont","first-page":"31","article-title":"Ten-year follow-up of implant-supported all-ceramic fixed dental prostheses: a randomized, prospective clinical trial","volume":"29","author":"Larsson","year":"2016","unstructured":"Larsson\n              C,\n            \n            \n              Vult von Steyern\n              P.\n            \n          \n          Ten-year follow-up of implant-supported all-ceramic fixed dental prostheses: a randomized, prospective clinical trial.\n\t\t\t\t\tInt J Prosthodont.\n\t\t\t\t\t2016;29:31\u201334."},{"key":"i1548-1336-48-3-202-b16","series-title":"Dent Mater","first-page":"299","article-title":"State of the art of zirconia for dental applications","volume":"24","author":"Denry","year":"2008","unstructured":"Denry\n              I,\n            \n            \n              Kelly\n              JR.\n            \n          \n          State of the art of zirconia for dental applications.\n\t\t\t\t\tDent Mater.\n\t\t\t\t\t2008;24:299\u2013307."},{"issue":"(suppl 1)","key":"i1548-1336-48-3-202-b17","series-title":"Aust Dental J","first-page":"84","article-title":"Ceramic materials in dentistry: historical evolution and current practice","volume":"56","author":"Kelly","year":"2011","unstructured":"Kelly\n              JR,\n            \n            \n              Benetti\n              P.\n            \n          \n          Ceramic materials in dentistry: historical evolution and current practice.\n\t\t\t\t\tAust Dental J.\n\t\t\t\t\t2011;56(suppl 1):\n\t\t\t\t\t84\u201396."},{"key":"i1548-1336-48-3-202-b18","series-title":"Dent Mater","first-page":"289","article-title":"Stabilized zirconia as a structural ceramic: an overview","volume":"24","author":"Kelly","year":"2008","unstructured":"Kelly\n              JR,\n            \n            \n              Denry\n              I.\n            \n          \n          Stabilized zirconia as a structural ceramic: an overview.\n\t\t\t\t\tDent Mater.\n\t\t\t\t\t2008;24:289\u2013298."},{"key":"i1548-1336-48-3-202-b19","series-title":"Clin Implant Dent Relat Res","first-page":"633","article-title":"Zirconia in fixed implant prosthodontics","volume":"14","author":"Guess","year":"2012","unstructured":"Guess\n              PC,\n            \n            \n              Att\n              W,\n            \n            \n              Strub\n              JR.\n            \n          \n          Zirconia in fixed implant prosthodontics.\n\t\t\t\t\tClin Implant Dent Relat Res.\n\t\t\t\t\t2012;14:633\u2013645."},{"key":"i1548-1336-48-3-202-b20","series-title":"J Prosthet Dent","first-page":"125","article-title":"Flexural strength of a layered zirconia and porcelain dental all-ceramic system","volume":"94","author":"White","year":"2005","unstructured":"White\n              SNM,\n            \n            \n              Miklus\n              VGD,\n            \n            \n              McLaren\n              EAD,\n            \n            \n              Lang\n              LAD,\n            \n            \n              Caputo\n              AAP.\n            \n          \n          Flexural strength of a layered zirconia and porcelain dental all-ceramic system.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2005;94:125\u2013131."},{"key":"i1548-1336-48-3-202-b21","series-title":"Dental Materials and Their Selection. 4th ed","first-page":"212","article-title":"Dental porcelain","author":"O'Brien","year":"2008","unstructured":"O'Brien\n              WJ.\n            \n          \n          Dental porcelain.\n\t\t\t\t\tIn:O'BrienWJ,ed.Dental Materials and Their Selection. 4th ed.\n\t\t\t\t\tHanoverPark, IL:\n\t\t\t\t\tQuintessence Publishing Co, Inc.;2008:\n\t\t\t\t\t212\u2013229."},{"key":"i1548-1336-48-3-202-b22","series-title":"J Prosthet Dent","first-page":"120","article-title":"Flexural strength and fracture toughness of dental core ceramics","volume":"98","author":"Yilmaz","year":"2007","unstructured":"Yilmaz\n              H,\n            \n            \n              Aydin\n              C,\n            \n            \n              Gul\n              BE.\n            \n          \n          Flexural strength and fracture toughness of dental core ceramics.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2007;98:120\u2013128."},{"key":"i1548-1336-48-3-202-b23","series-title":"Dent Mater","first-page":"441","article-title":"Strength, fracture toughness and microstructure of a selection of all-ceramic materials. part I. pressable and alumina glass- infiltrated ceramics","volume":"20","author":"Guazzato","year":"2004","unstructured":"Guazzato\n              M,\n            \n            \n              Albakry\n              M,\n            \n            \n              Ringer\n              SP,\n            \n            \n              Swain\n              MV.\n            \n          \n          Strength, fracture toughness and microstructure of a selection of all-ceramic materials. part I. pressable and alumina glass- infiltrated ceramics.\n\t\t\t\t\tDent Mater.\n\t\t\t\t\t2004;20:441\u2013448."},{"key":"i1548-1336-48-3-202-b24","series-title":"J Prosthet Dent","first-page":"140","article-title":"Biaxial flexural strength and indentation fracture toughness of three new dental core ceramics","volume":"76","author":"Wagner","year":"1996","unstructured":"Wagner\n              WC,\n            \n            \n              Chu\n              TM.\n            \n          \n          Biaxial flexural strength and indentation fracture toughness of three new dental core ceramics.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t1996;76:140\u2013144."},{"key":"i1548-1336-48-3-202-b25","series-title":"J Prosthet Dent","first-page":"358","article-title":"Clinical study to evaluate the wear of natural enamel antagonist to zirconia and metal ceramic crowns","volume":"114","author":"Mundhe","year":"2015","unstructured":"Mundhe\n              K,\n            \n            \n              Jain\n              V,\n            \n            \n              Pruthi\n              G,\n            \n            \n              Shah\n              N.\n            \n          \n          Clinical study to evaluate the wear of natural enamel antagonist to zirconia and metal ceramic crowns.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2015;114:358\u2013362."},{"key":"i1548-1336-48-3-202-b26","series-title":"Biomaterials","first-page":"1","article-title":"Zirconia as a ceramic biomaterial","volume":"20","author":"Piconi","year":"1999","unstructured":"Piconi\n              C,\n            \n            \n              Maccauro\n              G.\n            \n          \n          Zirconia as a ceramic biomaterial.\n\t\t\t\t\tBiomaterials.\n\t\t\t\t\t1999;20:1\u201325."},{"key":"i1548-1336-48-3-202-b27","series-title":"Dent Mater","first-page":"365","article-title":"Strength and fracture toughness of zirconia dental ceramics","volume":"34","author":"Turon-Vinas","year":"2018","unstructured":"Turon-Vinas\n              M,\n            \n            \n              Anglada\n              M.\n            \n          \n          Strength and fracture toughness of zirconia dental ceramics.\n\t\t\t\t\tDent Mater.\n\t\t\t\t\t2018;34:365\u2013375."},{"key":"i1548-1336-48-3-202-b28","series-title":"Dent Mater J","first-page":"820","article-title":"Effect of sintering on the marginal and internal fit of CAD\/CAM-fabricated zirconia frameworks","volume":"26","author":"Kunii","year":"2007","unstructured":"Kunii\n              J,\n            \n            \n              Hotta\n              Y,\n            \n            \n              Tamaki\n              Y,\n            \n            et al.\n          \n          Effect of sintering on the marginal and internal fit of CAD\/CAM-fabricated zirconia frameworks.\n\t\t\t\t\tDent Mater J.\n\t\t\t\t\t2007;26:820\u2013826."},{"key":"i1548-1336-48-3-202-b29","series-title":"Clin Oral Impl Res","first-page":"1401","article-title":"Time-efficiency analysis of the treatment with monolithic implant crowns in a digital workflow: a randomized controlled trial","volume":"27","author":"Joda","year":"2016","unstructured":"Joda\n              T,\n            \n            \n              Urs\n              B.\n            \n          \n          Time-efficiency analysis of the treatment with monolithic implant crowns in a digital workflow: a randomized controlled trial.\n\t\t\t\t\tClin Oral Impl Res.\n\t\t\t\t\t2016;27:1401\u20131406."},{"key":"i1548-1336-48-3-202-b30","series-title":"J Clin Periodontol","first-page":"225","article-title":"Restoration contour is a risk indicator for peri-implantitis: a cross-sectional radiographic analysis","volume":"45","author":"Katafuchi","year":"2018","unstructured":"Katafuchi\n              M,\n            \n            \n              Weinstein\n              BF,\n            \n            \n              Leroux\n              BG,\n            \n            \n              Chen\n              YW,\n            \n            \n              Daubert\n              DM.\n            \n          \n          Restoration contour is a risk indicator for peri-implantitis: a cross-sectional radiographic analysis.\n\t\t\t\t\tJ Clin Periodontol.\n\t\t\t\t\t2018;45:225\u2013232."},{"key":"i1548-1336-48-3-202-b31","series-title":"Eur J Oral Sci","first-page":"310","article-title":"Fracture resistance of zirconia-based all-ceramic crowns after bur adjustment","volume":"125","author":"Rues","year":"2017","unstructured":"Rues\n              S,\n            \n            \n              Schwindling\n              FS,\n            \n            \n              Meyer\n              A,\n            \n            \n              Rammelsberg\n              P,\n            \n            \n              Schmitter\n              M.\n            \n          \n          Fracture resistance of zirconia-based all-ceramic crowns after bur adjustment.\n\t\t\t\t\tEur J Oral Sci.\n\t\t\t\t\t2017;125:310\u2013313."},{"key":"i1548-1336-48-3-202-b32","series-title":"J Oral Rehabil","first-page":"702","article-title":"Fracture strength of four-unit Y-TZP FPD cores designed with varying connector diameter. An in-vitro study","volume":"34","author":"Larsson","year":"2007","unstructured":"Larsson\n              C,\n            \n            \n              Holm\n              L,\n            \n            \n              Lovgren\n              N,\n            \n            \n              Kokubo\n              Y,\n            \n            \n              Vult von Steyern\n              P.\n            \n          \n          Fracture strength of four-unit Y-TZP FPD cores designed with varying connector diameter. An in-vitro study.\n\t\t\t\t\tJ Oral Rehabil.\n\t\t\t\t\t2007;34:702\u2013709."},{"key":"i1548-1336-48-3-202-b33","series-title":"J Oral Implantol","first-page":"328","article-title":"Evaluation of fracture resistance of varying thicknesses of zirconia around implant abutment cylinders","volume":"43","author":"Park","year":"2017","unstructured":"Park\n              CJ,\n            \n            \n              Phark\n              J,\n            \n            \n              Chee\n              WW.\n            \n          \n          Evaluation of fracture resistance of varying thicknesses of zirconia around implant abutment cylinders.\n\t\t\t\t\tJ Oral Implantol.\n\t\t\t\t\t2017;43:328\u2013332."},{"key":"i1548-1336-48-3-202-b34","series-title":"Dent Mater","first-page":"934","article-title":"Microstructural analysis and reliability of monolithic zirconia after simulated adjustment protocols","volume":"33","author":"Chun","year":"2017","unstructured":"Chun\n              EP,\n            \n            \n              Anami\n              LC,\n            \n            \n              Bonfante\n              EA,\n            \n            \n              Bottino,\n              MA.\n            \n          \n          Microstructural analysis and reliability of monolithic zirconia after simulated adjustment protocols.\n\t\t\t\t\tDent Mater.\n\t\t\t\t\t2017;33:934\u2013943."},{"key":"i1548-1336-48-3-202-b35","series-title":"J Prosthet Dent","first-page":"430","article-title":"Effect of various polishing systems on the surface roughness and phase transformation of zirconia and the durability of the polishing systems","volume":"117","author":"Park","year":"2017","unstructured":"Park\n              C,\n            \n            \n              Vang\n              M,\n            \n            \n              Park\n              S,\n            \n            \n              Lim\n              H.\n            \n          \n          Effect of various polishing systems on the surface roughness and phase transformation of zirconia and the durability of the polishing systems.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2017;117:430\u2013437."},{"key":"i1548-1336-48-3-202-b36","series-title":"J Mech Behav of Biomed Mater","first-page":"75","article-title":"Crack propagation and material removal mechanism of glass-ceramics by scratch test","volume":"64","author":"Qiu","year":"2016","unstructured":"Qiu\n              Z,\n            \n            \n              Liu\n              C,\n            \n            \n              Wang\n              H,\n            \n            \n              Yang\n              X,\n            \n            \n              Fang\n              F,\n            \n            \n              Tang\n              J.\n            \n          \n          Crack propagation and material removal mechanism of glass-ceramics by scratch test.\n\t\t\t\t\tJ Mech Behav of Biomed Mater.\n\t\t\t\t\t2016;64:75\u201385."},{"key":"i1548-1336-48-3-202-b37","series-title":"J Mech Behav of Biomed Mater","first-page":"512","article-title":"Fatigue strength of yttria-stabilized zirconia polycrystals: effects of grinding, polishing, glazing, and heat treatment","volume":"75","author":"Zucuni","year":"2017","unstructured":"Zucuni\n              J,\n            \n            \n              Guilardi\n              L,\n            \n            \n              Rippe\n              M,\n            \n            \n              Pereira\n              G,\n            \n            \n              Valandro\n              L.\n            \n          \n          Fatigue strength of yttria-stabilized zirconia polycrystals: effects of grinding, polishing, glazing, and heat treatment.\n\t\t\t\t\tJ Mech Behav of Biomed Mater.\n\t\t\t\t\t2017;75:512\u2013520."},{"key":"i1548-1336-48-3-202-b38","series-title":"J Prosthet Dent","first-page":"61","article-title":"Zirconia changes after grinding and regeneration firing","volume":"118","author":"Hatanaka","year":"2017","unstructured":"Hatanaka\n              GR,\n            \n            \n              Polli\n              GS,\n            \n            \n              Fais\n              LM,\n            \n            \n              Reis\n              JMSN,\n            \n            \n              Pinelli\n              LAP.\n            \n          \n          Zirconia changes after grinding and regeneration firing.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2017;118:61\u201368."},{"key":"i1548-1336-48-3-202-b39","series-title":"J Prosthet Dent","first-page":"658","article-title":"Effect of coarse grinding, overglazing, and 2 polishing systems on the flexural strength, surface roughness, and phase transformation of yttrium-stabilized tetragonal zirconia","volume":"27","author":"Mohammadi-Bassir","year":"2017","unstructured":"Mohammadi-Bassir\n              M,\n            \n            \n              Babasafari\n              M,\n            \n            \n              Rezvani\n              MB,\n            \n            \n              Jamshidian\n              M.\n            \n          \n          Effect of coarse grinding, overglazing, and 2 polishing systems on the flexural strength, surface roughness, and phase transformation of yttrium-stabilized tetragonal zirconia.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2017;27:658\u2013665."},{"key":"i1548-1336-48-3-202-b40","series-title":"Nature","first-page":"703","article-title":"Ceramic steel?","volume":"258","author":"Garvie","year":"1975","unstructured":"Garvie\n              RC,\n            \n            \n              Hannink\n              RH,\n            \n            \n              Pascoe\n              RT.\n            \n          \n          Ceramic steel?\n          \n            Nature\n          .\n\t\t\t\t\t1975;258:703\u2013704."},{"key":"i1548-1336-48-3-202-b41","series-title":"Dent Mater","first-page":"e180","article-title":"Post-hot isostatic pressing: a healing treatment for process related defects and laboratory grinding damage of dental zirconia?","volume":"29","author":"Scherrer","year":"2013","unstructured":"Scherrer\n              D,\n            \n            \n              Cattani-Lorente\n              M,\n            \n            \n              Yoon\n              S,\n            \n            et al.\n          \n          Post-hot isostatic pressing: a healing treatment for process related defects and laboratory grinding damage of dental zirconia?\n          \n            Dent Mater\n          .\n\t\t\t\t\t2013;29:e180\u2013e190."},{"key":"i1548-1336-48-3-202-b42","series-title":"J Mech Behav Biomed Mater","first-page":"133","article-title":"Effect of grinding with diamond-disc and \u2013bur on the mechanical behavior of a Y-TZP ceramic","volume":"37","author":"Pereira","year":"2014","unstructured":"Pereira\n              GKR,\n            \n            \n              Amaral\n              M,\n            \n            \n              Simoneti\n              R,\n            \n            \n              Rocha\n              GC,\n            \n            \n              Cesar\n              PF,\n            \n            \n              Valandro\n              LF.\n            \n          \n          Effect of grinding with diamond-disc and \u2013bur on the mechanical behavior of a Y-TZP ceramic.\n\t\t\t\t\tJ Mech Behav Biomed Mater.\n\t\t\t\t\t2014;37:133\u2013140."},{"key":"i1548-1336-48-3-202-b43","series-title":"Biomed Res Int","first-page":"418641","article-title":"Fracture strength of aged monolithic and bilayer zirconia-based crowns","volume":"2015","author":"Lameira","year":"2015","unstructured":"Lameira\n              DP,\n            \n            \n              Silva\n              WA,\n            \n            \n              Silva\n              FA,\n            \n            \n              De Souza\n              GM.\n            \n          \n          Fracture strength of aged monolithic and bilayer zirconia-based crowns.\n\t\t\t\t\tBiomed Res Int.\n\t\t\t\t\t2015;2015:418641."},{"key":"i1548-1336-48-3-202-b44","series-title":"J Prosthet Dent","first-page":"630","article-title":"Load at fracture of monolithic and bilayered zirconia crowns with and without a cervical zirconia col-lar","volume":"115","author":"Oilo","year":"2016","unstructured":"Oilo\n              M,\n            \n            \n              Kvam\n              K,\n            \n            \n              Gjerdet\n              NR.\n            \n          \n          Load at fracture of monolithic and bilayered zirconia crowns with and without a cervical zirconia col-lar.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t2016;115:630\u2013636."},{"key":"i1548-1336-48-3-202-b45","series-title":"Dent Mater","first-page":"1552","article-title":"Influence of surface treatment on the in-vitro fracture resistance of zirconia-based all-ceramic anterior crowns","volume":"31","author":"Schmitter","year":"2015","unstructured":"Schmitter\n              M,\n            \n            \n              Lotze\n              G,\n            \n            \n              Rues\n              S.\n            \n          \n          Influence of surface treatment on the in-vitro fracture resistance of zirconia-based all-ceramic anterior crowns.\n\t\t\t\t\tDent Mater.\n\t\t\t\t\t2015;31:1552\u20131560."},{"key":"i1548-1336-48-3-202-b46","series-title":"Clin Oral Impl Res","first-page":"1119","article-title":"Fracture resistance of implant-supported screw-retained zirconia-based molar restorations","volume":"28","author":"Honda","year":"2017","unstructured":"Honda\n              J,\n            \n            \n              Komine\n              F,\n            \n            \n              Kamio\n              S,\n            \n            \n              Taguchi\n              K,\n            \n            \n              Blatz\n              MB,\n            \n            \n              Matsumura\n              H.\n            \n          \n          Fracture resistance of implant-supported screw-retained zirconia-based molar restorations.\n\t\t\t\t\tClin Oral Impl Res.\n\t\t\t\t\t2017;28:1119\u20131126."},{"key":"i1548-1336-48-3-202-b47","series-title":"Scand J Dent Res","first-page":"171","article-title":"Novel bite force recorder and maximal isometric bite force values for healthy young adults","volume":"101","author":"Waltimo","year":"1993","unstructured":"Waltimo\n              A,\n            \n            \n              Kononen\n              MA.\n            \n          \n          Novel bite force recorder and maximal isometric bite force values for healthy young adults.\n\t\t\t\t\tScand J Dent Res.\n\t\t\t\t\t1993;101:171\u2013175."},{"key":"i1548-1336-48-3-202-b48","series-title":"Eur Journal Orthod","first-page":"427","article-title":"Maximum voluntary molar bite force in subjects with normal occlusion","volume":"33","author":"Varga","year":"2011","unstructured":"Varga\n              S,\n            \n            \n              Spalj\n              S,\n            \n            \n              Lapter Varga\n              M,\n            \n            \n              Anic Milosevic\n              S,\n            \n            \n              Mestrovic\n              S,\n            \n            \n              Slaj\n              M.\n            \n          \n          Maximum voluntary molar bite force in subjects with normal occlusion.\n\t\t\t\t\tEur Journal Orthod.\n\t\t\t\t\t2011;33:427\u2013433."},{"key":"i1548-1336-48-3-202-b49","series-title":"J Dent","first-page":"451","article-title":"Maximal bite forces in healthy young adults as predicted by surface electromyography","volume":"32","author":"Ferrario","year":"2004","unstructured":"Ferrario\n              VF,\n            \n            \n              Sforza\n              C,\n            \n            \n              Zanotti\n              G,\n            \n            \n              Tartaglia\n              GM.\n            \n          \n          Maximal bite forces in healthy young adults as predicted by surface electromyography.\n\t\t\t\t\tJ Dent.\n\t\t\t\t\t2004;32:451\u2013457."},{"key":"i1548-1336-48-3-202-b50","series-title":"J Prosthet Dent","first-page":"226","article-title":"Limits of human bite strength","volume":"56","author":"Gibbs","year":"1986","unstructured":"Gibbs\n              C,\n            \n            \n              Mahan\n              P,\n            \n            \n              Mauderli\n              A,\n            \n            \n              Lundeen\n              H,\n            \n            \n              Walsh\n              E.\n            \n          \n          Limits of human bite strength.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t1986;56:226\u2013229."},{"key":"i1548-1336-48-3-202-b51","series-title":"J Prosthet Dent","first-page":"443","article-title":"Occlusal forces during chewing and swallowing as measure by sound transmission","volume":"46","author":"Gibbs","year":"1981","unstructured":"Gibbs\n              C,\n            \n            \n              Mahan\n              P,\n            \n            \n              Lundeen\n              H,\n            \n            \n              Brehnan\n              K,\n            \n            \n              Walsh\n              E,\n            \n            \n              Holbrook\n              W.\n            \n          \n          Occlusal forces during chewing and swallowing as measure by sound transmission.\n\t\t\t\t\tJ Prosthet Dent.\n\t\t\t\t\t1981;46:443."},{"key":"i1548-1336-48-3-202-b52","series-title":"Clin Oral Implants Res","first-page":"81","article-title":"The soft tissue barrier at implants and teeth","volume":"2","author":"Berglundh","year":"1991","unstructured":"Berglundh\n              T,\n            \n            \n              Lindhe\n              J,\n            \n            \n              Ericsson\n              I,\n            \n            \n              Marinello\n              CP,\n            \n            \n              Liljenberg\n              B,\n            \n            \n              Thomsen\n              P.\n            \n          \n          The soft tissue barrier at implants and teeth.\n\t\t\t\t\tClin Oral Implants Res.\n\t\t\t\t\t1991;2:81\u201390."},{"key":"i1548-1336-48-3-202-b53","series-title":"Clin Oral Implants Res","first-page":"433","article-title":"Connective tissue orientation around dental implants in a canine model","volume":"12","author":"Comut","year":"2001","unstructured":"Comut\n              AA,\n            \n            \n              Weber\n              HP,\n            \n            \n              Shortkroff\n              S,\n            \n            \n              Cui\n              FZ,\n            \n            \n              Spector\n              M.\n            \n          \n          Connective tissue orientation around dental implants in a canine model.\n\t\t\t\t\tClin Oral Implants Res.\n\t\t\t\t\t2001;12:433\u2013440."},{"key":"i1548-1336-48-3-202-b54","series-title":"Int J Oral Maxillofac Surg","first-page":"39","article-title":"Marginal tissue reactions at osseointegrated titanium fixtures. A 3-year longitudinal prospective study","volume":"15","author":"Adell","year":"1986","unstructured":"Adell\n              R,\n            \n            \n              Lekholm\n              U,\n            \n            \n              Rockler\n              B,\n            \n            et al.\n          \n          Marginal tissue reactions at osseointegrated titanium fixtures. A 3-year longitudinal prospective study.\n\t\t\t\t\tInt J Oral Maxillofac Surg.\n\t\t\t\t\t1986;15:39\u201352."},{"key":"i1548-1336-48-3-202-b55","series-title":"J Biomech","first-page":"393","article-title":"The elastic and ultimate properties of compact bone tissue","volume":"8","author":"Reilly","year":"1975","unstructured":"Reilly\n              DT,\n            \n            \n              Burstein\n              AH.\n            \n          \n          The elastic and ultimate properties of compact bone tissue.\n\t\t\t\t\tJ Biomech.\n\t\t\t\t\t1975;8:393\u2013405."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/48\/3\/article-p202.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/joi\/article-pdf\/48\/3\/202\/3099015\/i1548-1336-48-3-202.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/48\/3\/article-p202.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/48\/3\/article-p202.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T00:18:07Z","timestamp":1752193087000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/48\/3\/article-p202.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6]]},"references-count":55,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-20-00144","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"value":"1548-1336","type":"electronic"},{"value":"0160-6972","type":"print"}],"subject":[],"published":{"date-parts":[[2022,6]]}}}