{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,20]],"date-time":"2026-06-20T03:34:55Z","timestamp":1781926495712,"version":"3.54.5"},"reference-count":29,"publisher":"American Academy of Implant Dentistry","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,12]]},"abstract":"<jats:p>The objective was to evaluate the influence of residual bone height (RBH) and implant macro-design on the primary stability (PS) of implants using a simultaneous sinus floor elevation (SFE) and implant insertion model. Fresh bovine rib samples that resembled type-IV density that were confirmed by computerized tomography were prepared to represent 4 groups of varying RBHs (3, 6, 9, 15 mm). To simulate simultaneous implant insertion with SFE, 120 implants in different macro-designs (group R: NobelReplace; group P: NobelParallel; group A: NobelActive, Nobel Biocare, Gothenburg, Sweden) were randomly inserted at RBHs of 3, 6, 9, and 15 mm in each rib. The implant stability quotient (ISQ) was measured immediately after implant insertion. RBH and implant macro-design have an impact on ISQ values (<jats:italic>P<\/jats:italic> &lt; .001). ISQ values were the highest with RBH of 15 mm, followed by RBHs of 9, 6, and 3 mm. (<jats:italic>P<\/jats:italic> &lt; .001). There was no statistically significant difference between different implant macro-designs at RBHs of 3 and 15 mm regarding ISQ values (<jats:italic>P<\/jats:italic> = .111, <jats:italic>P<\/jats:italic> = .551). ISQ values of group P were higher than those of group R and group A at an RBH of 6 mm (<jats:italic>P<\/jats:italic> = .049, <jats:italic>P<\/jats:italic> = .029). ISQ values were also higher in group P compared to group A at an RBH of 9 mm (<jats:italic>P<\/jats:italic> = .006). A higher PS may be expected in sites with higher RBH, regardless of the macro-design. In addition, cylindric implant design may enhance the PS at RBHs of 6 and 9 mm in simultaneous implant insertion with SFE.<\/jats:p>","DOI":"10.1563\/aaid-joi-d-22-00197","type":"journal-article","created":{"date-parts":[[2024,1,23]],"date-time":"2024-01-23T05:20:33Z","timestamp":1705987233000},"page":"578-583","source":"Crossref","is-referenced-by-count":1,"title":["Effect of Residual Bone Height and Implant Macro-Design on Primary Stability in Sinus Floor Elevation: An Ex Vivo Study"],"prefix":"10.1563","volume":"49","author":[{"given":"Berkay","family":"Tokuc","sequence":"first","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Kocaeli University, Turkey."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Merve","family":"\u00c7ak\u0131r","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Okan University, Turkey."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G\u00fcl Merve","family":"Yal\u00e7\u0131n \u00dclker","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Okan University, Turkey."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Onur","family":"Ge\u00e7kili","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Faculty of Dentistry, \u0130stanbul University, Turkey."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deniz G\u00f6k\u00e7e","family":"Meral","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Okan University, Turkey."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bahad\u0131r","family":"Kan","sequence":"additional","affiliation":[{"name":"Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Okan University, Turkey."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"434","reference":[{"key":"i1548-1336-49-6-578-b01","series-title":"Clin Oral Implants Res","first-page":"106","article-title":"Implant placement and loading protocols in partially edentulous patients: a systematic review","volume":"29","author":"Gallucci","year":"2018","unstructured":"Gallucci\n              GO,\n            \n            \n              Hamilton\n              A,\n            \n            \n              Zhou\n              W,\n            \n            \n              Buser\n              D,\n            \n            \n              Chen\n              S.\n            \n          \n          Implant placement and loading protocols in partially edentulous patients: a systematic review. Clin Oral Implants Res. 2018;29:106\u2013134."},{"key":"i1548-1336-49-6-578-b02","series-title":"Clin Implant Dent Relat Res","first-page":"60","article-title":"Direct implant loading in the edentulous maxilla using a bone density-adapted surgical protocol and primary implant stability criteria for inclusion","volume":"7","author":"Ostman","year":"2005","unstructured":"Ostman\n              PO,\n            \n            \n              Hellman\n              M,\n            \n            \n              Sennerby\n              L.\n            \n          \n          Direct implant loading in the edentulous maxilla using a bone density-adapted surgical protocol and primary implant stability criteria for inclusion. Clin Implant Dent Relat Res, 2005;7:60\u201369."},{"key":"i1548-1336-49-6-578-b03","series-title":"Clin Oral Implants Res","first-page":"240","article-title":"Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial","volume":"26","author":"Torroella-Saura","year":"2015","unstructured":"Torroella-Saura\n              G,\n            \n            \n              Mareque-Bueno\n              J,\n            \n            \n              Cabratosa-Termes\n              J,\n            \n            \n              Hern\u00e1ndez-Alfaro\n              F,\n            \n            \n              Ferr\u00e9s-Padr\u00f3\n              E,\n            \n            \n              Calvo-Guirado\n              JL.\n            \n          \n          Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial. Clin Oral Implants Res, 2015;26:240\u2013244."},{"key":"i1548-1336-49-6-578-b04","series-title":"Int J Oral Maxillofac Implants","first-page":"549","article-title":"Augmentation grafting of the maxillary sinus and simultaneous implant placement in patients with 3 to 5 mm of residual alveolar bone height","volume":"14","author":"Peleg","year":"1999","unstructured":"Peleg\n              M,\n            \n            \n              Mazor\n              Z,\n            \n            \n              Garg\n              AK.\n            \n          \n          Augmentation grafting of the maxillary sinus and simultaneous implant placement in patients with 3 to 5 mm of residual alveolar bone height. Int J Oral Maxillofac Implants. 1999;14:549\u2013556."},{"key":"i1548-1336-49-6-578-b05","series-title":"Clin Oral Implants Res","first-page":"124","article-title":"Clinical outcomes of sinus floor augmentation for implant placement using autogenous bone or bone substitutes: a systematic review","volume":"20","author":"Nkenke","year":"2009","unstructured":"Nkenke\n              E,\n            \n            \n              Stelzle\n              F.\n            \n          \n          Clinical outcomes of sinus floor augmentation for implant placement using autogenous bone or bone substitutes: a systematic review. Clin Oral Implants Res. 2009;20:124\u2013133."},{"key":"i1548-1336-49-6-578-b06","series-title":"Clin Implant Dent Relat Res","first-page":"218","article-title":"Correlation between implant stability quotient and bone-implant contact: a retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans","volume":"8","author":"Scarano","year":"2006","unstructured":"Scarano\n              A,\n            \n            \n              Degidi\n              M,\n            \n            \n              Iezzi\n              G,\n            \n            \n              Petrone\n              G,\n            \n            \n              Piattelli\n              A.\n            \n          \n          Correlation between implant stability quotient and bone-implant contact: a retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans. Clin Implant Dent Relat Res. 2006;8:218\u2013222."},{"key":"i1548-1336-49-6-578-b07","series-title":"Implant Dent","first-page":"59","article-title":"Immediate loading of the grafted maxillary sinus using platelet rich plasma and autogenous bone: a preliminary study with histologic and histomorphometric analysis","volume":"17","author":"Lee","year":"2008","unstructured":"Lee\n              CY,\n            \n            \n              Rohrer\n              MD,\n            \n            \n              Prasad\n              HS.\n            \n          \n          Immediate loading of the grafted maxillary sinus using platelet rich plasma and autogenous bone: a preliminary study with histologic and histomorphometric analysis. Implant Dent. 2008;17:59\u201373."},{"key":"i1548-1336-49-6-578-b08","series-title":"Clin Oral Implants Res","first-page":"555","article-title":"Influence of residual alveolar bone height on osseointegration of implants in the maxilla: a pilot study","volume":"20","author":"Fenner","year":"2009","unstructured":"Fenner\n              M,\n            \n            \n              Vairaktaris\n              E,\n            \n            \n              Fischer\n              K,\n            \n            \n              Schlegel\n              KA,\n            \n            \n              Neukam\n              FW,\n            \n            \n              Nkenke\n              E.\n            \n          \n          Influence of residual alveolar bone height on osseointegration of implants in the maxilla: a pilot study. Clin Oral Implants Res. 2009;20:555\u2013559."},{"key":"i1548-1336-49-6-578-b09","series-title":"J Oral Implantol","first-page":"59","article-title":"Comparative assessment of the primary stability of Straumann\u00ae BLX implant design using an in-vitro sinus lift-simultaneous implant insertion model","volume":"48","author":"Emmert","year":"2022","unstructured":"Emmert\n              M,\n            \n            \n              Spille\n              J,\n            \n            \n              Behrens\n              E,\n            \n            et al.\n          \n          Comparative assessment of the primary stability of Straumann\u00ae BLX implant design using an in-vitro sinus lift-simultaneous implant insertion model. J Oral Implantol. 2022;48:59\u201373."},{"key":"i1548-1336-49-6-578-b10","series-title":"Clin Oral Implants Res","first-page":"656","article-title":"Evaluation of the insertion torque, implant stability quotient and drilled hole quality for different drill design: an in vitro Investigation","volume":"29","author":"Gehrke","year":"2018","unstructured":"Gehrke\n              SA,\n            \n            \n              Guirado\n              JLC,\n            \n            \n              Bettach\n              R,\n            \n            \n              Fabbro\n              MD,\n            \n            \n              Mart\u00ednez\n              CP,\n            \n            \n              Shibli\n              JA.\n            \n          \n          Evaluation of the insertion torque, implant stability quotient and drilled hole quality for different drill design: an in vitro Investigation. Clin Oral Implants Res. 2018;29:656\u2013662."},{"key":"i1548-1336-49-6-578-b11","series-title":"Patient Selection and Preparation. Tissue Integrated Prostheses","author":"Lekholm","year":"1985","unstructured":"Lekholm\n              U,\n            \n            \n              Zarb\n              GA,\n            \n            \n              Albrektsson\n              T.\n            \n          \n          \n            Patient Selection and Preparation. Tissue Integrated Prostheses\n          . Chicago: Quintessence Publishing Co. Inc.; 1985."},{"key":"i1548-1336-49-6-578-b12","series-title":"Med Oral Patol Oral Cir Bucal","first-page":"93","article-title":"In vitro evaluation of the influence of the cortical bone on the primary stability of two implant systems","volume":"14","author":"Andr\u00e9s-Garc\u00eda","year":"2009","unstructured":"Andr\u00e9s-Garc\u00eda\n              R,\n            \n            \n              Vives\n              NG,\n            \n            \n              Climent\n              FH,\n            \n            et al.\n          \n          In vitro evaluation of the influence of the cortical bone on the primary stability of two implant systems. Med Oral Patol Oral Cir Bucal. 2009;14:93\u201397."},{"key":"i1548-1336-49-6-578-b13","series-title":"Clin Oral Implants Res","first-page":"79","article-title":"Bone classification: an objective scale of bone density using the computerized tomography scan","volume":"12","author":"Norton","year":"2001","unstructured":"Norton\n              MR,\n            \n            \n              Gamble\n              C.\n            \n          \n          Bone classification: an objective scale of bone density using the computerized tomography scan. Clin Oral Implants Res. 2001;12:79\u201384."},{"key":"i1548-1336-49-6-578-b14","series-title":"J Crit Care","first-page":"187","article-title":"Randomization and allocation concealment: a practical guide for researchers","volume":"20","author":"Doig","year":"2005","unstructured":"Doig\n              GS,\n            \n            \n              Simpson\n              F.\n            \n          \n          Randomization and allocation concealment: a practical guide for researchers. J Crit Care. 2005;20:187\u2013191."},{"key":"i1548-1336-49-6-578-b15","series-title":"Int J Oral Maxillofac Implants","first-page":"700","article-title":"In vitro evaluation of the primary stability of short implants in different surgical techniques","volume":"35","author":"Kucukguven","year":"2020","unstructured":"Kucukguven\n              MB,\n            \n            \n              Topaloglu\n              G,\n            \n            \n              Is\u0131khan\n              SY,\n            \n            \n              Tosun\n              E,\n            \n            \n              Saysel\n              MY.\n            \n          \n          In vitro evaluation of the primary stability of short implants in different surgical techniques. Int J Oral Maxillofac Implants. 2020;35:700\u2013706."},{"key":"i1548-1336-49-6-578-b16","series-title":"Int J Oral Maxillofac Surg","first-page":"1345","article-title":"Long-term clinical outcomes of immediate loading versus non-immediate loading in single-implant restorations: a systematic review and meta-analysis","volume":"51","author":"Zhao","year":"2022","unstructured":"Zhao\n              G,\n            \n            \n              Zhou\n              Y,\n            \n            \n              Shi\n              S,\n            \n            \n              Liu\n              X,\n            \n            \n              Zhang\n              S,\n            \n            \n              Song\n              Y.\n            \n          \n          Long-term clinical outcomes of immediate loading versus non-immediate loading in single-implant restorations: a systematic review and meta-analysis. Int J Oral Maxillofac Surg. 2022;51:1345\u20131354."},{"key":"i1548-1336-49-6-578-b17","series-title":"Clin Implant Dent Relat Res","first-page":"204","article-title":"Immediate occlusal loading of Bra\u030anemark implants applied in various jawbone regions: a prospective, 1-year clinical study","volume":"3","author":"Glauser","year":"2001","unstructured":"Glauser\n              R,\n            \n            \n              R\u00e9e\n              A,\n            \n            \n              Lundgren\n              AK,\n            \n            \n              Gottlow\n              J,\n            \n            \n              H\u00e4mmerle\n              CHF,\n            \n            \n              Sch\u00e4rer\n              P.\n            \n          \n          Immediate occlusal loading of Bra\u030anemark implants applied in various jawbone regions: a prospective, 1-year clinical study. Clin Implant Dent Relat Res. 2001;3:204\u2013213."},{"key":"i1548-1336-49-6-578-b18","series-title":"Clin Implant Dent Relat Res","first-page":"609","article-title":"Immediate loading of implants placed simultaneously with sinus membrane elevation in the posterior atrophic maxilla: a two-year follow-up study on 10 patients","volume":"16","author":"Cricchio","year":"2014","unstructured":"Cricchio\n              G,\n            \n            \n              Imburgia\n              M,\n            \n            \n              Sennerby\n              L,\n            \n            \n              Lundgren\n              S.\n            \n          \n          Immediate loading of implants placed simultaneously with sinus membrane elevation in the posterior atrophic maxilla: a two-year follow-up study on 10 patients. Clin Implant Dent Relat Res. 2014;16:609\u2013617."},{"key":"i1548-1336-49-6-578-b19","series-title":"Clin Implant Dent Relat Res","first-page":"151","article-title":"Sinus augmentation and concomitant implant placement in low bone-density sites. A retrospective study on an undersized drilling protocol and primary stability","volume":"20","author":"Arosio","year":"2018","unstructured":"Arosio\n              P,\n            \n            \n              Greco\n              GB,\n            \n            \n              Zaniol\n              T,\n            \n            \n              Iezzi\n              G,\n            \n            \n              Perrotti\n              V,\n            \n            \n              Di Stefano\n              DA.\n            \n          \n          Sinus augmentation and concomitant implant placement in low bone-density sites. A retrospective study on an undersized drilling protocol and primary stability. Clin Implant Dent Relat Res. 2018;20:151\u2013159."},{"key":"i1548-1336-49-6-578-b20","series-title":"Clin Oral Implants Res","first-page":"705","article-title":"Primary stability and healing outcomes of apically tapered and straight implants placed into fresh extraction sockets. A pre-clinical in vivo study","volume":"31","author":"Ellis","year":"2020","unstructured":"Ellis\n              R,\n            \n            \n              Chen\n              S,\n            \n            \n              Davies\n              H,\n            \n            \n              Fitzgerald\n              W,\n            \n            \n              Xu\n              J,\n            \n            \n              Darby\n              I.\n            \n          \n          Primary stability and healing outcomes of apically tapered and straight implants placed into fresh extraction sockets. A pre-clinical in vivo study. Clin Oral Implants Res. 2020;31:705\u2013714."},{"key":"i1548-1336-49-6-578-b21","series-title":"A biomechanical investigation. Spine","first-page":"1215","article-title":"Changes in cadaveric cancellous vertebral bone strength in relation to time","volume":"23","author":"K\u00e4\u00e4b","year":"1998","unstructured":"K\u00e4\u00e4b\n              MJ,\n            \n            \n              Putz\n              R,\n            \n            \n              Gebauer\n              D,\n            \n            \n              Plitz\n              W.\n            \n          \n          Changes in cadaveric cancellous vertebral bone strength in relation to time. A biomechanical investigation. Spine. 1998;23:1215\u20131219."},{"key":"i1548-1336-49-6-578-b22","series-title":"Int J Oral Maxillofac Implants","first-page":"1203","article-title":"A prospective study of implants placed in augmented sinuses with minimal and moderate residual crestal bone: results after 1 to 5 years","volume":"25","author":"Urban","year":"2010","unstructured":"Urban\n              IA,\n            \n            \n              Lozada\n              JL.\n            \n          \n          A prospective study of implants placed in augmented sinuses with minimal and moderate residual crestal bone: results after 1 to 5 years. Int J Oral Maxillofac Implants. 2010;25:1203\u20131212."},{"key":"i1548-1336-49-6-578-b23","series-title":"Implant Dent","first-page":"402","article-title":"The influence of remaining alveolar bone upon lateral window sinus augmentation implant survival","volume":"18","author":"Rios","year":"2009","unstructured":"Rios\n              HF,\n            \n            \n              Avila\n              G,\n            \n            \n              Galindo\n              P,\n            \n            \n              Bratu\n              E,\n            \n            \n              Wang\n              HL.\n            \n          \n          The influence of remaining alveolar bone upon lateral window sinus augmentation implant survival. Implant Dent. 2009;18:402\u2013412."},{"key":"i1548-1336-49-6-578-b24","series-title":"Clin Oral Implants Res","first-page":"109","article-title":"Primary implant stability in the atrophic sinus floor of human cadaver maxillae: impact of residual ridge height, bone density, and implant diameter","volume":"25","author":"Pommer","year":"2014","unstructured":"Pommer\n              B,\n            \n            \n              Hof\n              M,\n            \n            \n              F\u00e4dler\n              A,\n            \n            \n              Gahleitner\n              A,\n            \n            \n              Watzek\n              G,\n            \n            \n              Watzak\n              G.\n            \n          \n          Primary implant stability in the atrophic sinus floor of human cadaver maxillae: impact of residual ridge height, bone density, and implant diameter. Clin Oral Implants Res. 2014;25:109\u2013113."},{"key":"i1548-1336-49-6-578-b25","series-title":"Clin Oral Implants Res","first-page":"240","article-title":"Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial","volume":"26","author":"Torroella-Saura","year":"2015","unstructured":"Torroella-Saura\n              G,\n            \n            \n              Mareque-Bueno\n              J,\n            \n            \n              Cabratosa-Termes\n              J,\n            \n            \n              Hern\u00e1ndez-Alfaro\n              F,\n            \n            \n              Ferr\u00e9s-Padr\u00f3\n              E,\n            \n            \n              Calvo-Guirado\n              JL.\n            \n          \n          Effect of implant design in immediate loading. A randomized, controlled, split-mouth, prospective clinical trial. Clin Oral Implants Res. 2015;26:240\u2013244."},{"key":"i1548-1336-49-6-578-b26","series-title":"Int J Environ Res Public Health","first-page":"9238","article-title":"An in vitro analysis on polyurethane foam blocks of the insertion torque (IT) Values, removal torque values (RTVs), and resonance frequency analysis (RFA) values in tapered and cylindrical implants","volume":"18","author":"Comuzzi","year":"2021","unstructured":"Comuzzi\n              L,\n            \n            \n              Tumedei\n              M,\n            \n            \n              D\u2019Arcangelo\n              C,\n            \n            \n              Piattelli\n              A,\n            \n            \n              Iezzi\n              G.\n            \n          \n          An in vitro analysis on polyurethane foam blocks of the insertion torque (IT) Values, removal torque values (RTVs), and resonance frequency analysis (RFA) values in tapered and cylindrical implants. Int J Environ Res Public Health. 2021;18:9238."},{"key":"i1548-1336-49-6-578-b27","series-title":"Int J Oral Maxillofac Implants","first-page":"824","article-title":"Correlation between implant geometry, implant surface, insertion torque, and primary stability: in vitro biomechanical analysis","volume":"33","author":"Falco","year":"2018","unstructured":"Falco\n              A,\n            \n            \n              Berardini\n              M,\n            \n            \n              Trisi\n              P.\n            \n          \n          Correlation between implant geometry, implant surface, insertion torque, and primary stability: in vitro biomechanical analysis. Int J Oral Maxillofac Implants. 2018;33:824\u2013830."},{"key":"i1548-1336-49-6-578-b28","series-title":"Clin Oral Implants Res","first-page":"649","article-title":"Influence of the implant diameter and bone quality on the primary stability of porous tantalum trabecular metal dental implants: an in vitro biomechanical study","volume":"29","author":"Romanos","year":"2018","unstructured":"Romanos\n              GE,\n            \n            \n              Delgado-Ruiz\n              RA,\n            \n            \n              Sacks\n              D,\n            \n            \n              Calvo-Guirado\n              JL.\n            \n          \n          Influence of the implant diameter and bone quality on the primary stability of porous tantalum trabecular metal dental implants: an in vitro biomechanical study. Clin Oral Implants Res. 2018;29:649\u2013655."},{"key":"i1548-1336-49-6-578-b29","series-title":"Clin Oral Implants Res","first-page":"202","article-title":"Implant design and intraosseous stability of immediately placed implants: a human cadaver study","volume":"16","author":"Akkocaoglu","year":"2005","unstructured":"Akkocaoglu\n              M,\n            \n            \n              Uysal\n              S,\n            \n            \n              Tekdemir\n              I,\n            \n            \n              Akca\n              K,\n            \n            \n              Cehreli\n              MC.\n            \n          \n          Implant design and intraosseous stability of immediately placed implants: a human cadaver study. Clin Oral Implants Res. 2005;16:202\u2013209."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/49\/6\/article-p578.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/joi\/article-pdf\/49\/6\/578\/3342636\/i1548-1336-49-6-578.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/49\/6\/article-p578.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/49\/6\/article-p578.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T00:20:45Z","timestamp":1752193245000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/49\/6\/article-p578.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,12]]},"references-count":29,"journal-issue":{"issue":"6"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-22-00197","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"value":"1548-1336","type":"electronic"},{"value":"0160-6972","type":"print"}],"subject":[],"published":{"date-parts":[[2023,12]]}}}