{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,12]],"date-time":"2025-07-12T00:01:07Z","timestamp":1752278467287,"version":"3.41.2"},"reference-count":20,"publisher":"American Academy of Implant Dentistry","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2023,10]]},"abstract":"<jats:p>This in vitro study was conducted to investigate the repeatability of the implant stability quotients (ISQ) measured with multipegs after numerous sterilizations and to detect the exact time when the readings start to deviate. Multipegs were sterilized with 3 different methods (autoclaved, autoclaved + ultrasonic cleaner, chemical disinfection + autoclaved) and grouped according to the method applied. All specimens were put into the autoclave with sealed packages every time they were sterilized. Each specimen was sterilized 50 times according to the technique described in its group after an ISQ measurement was performed. Results of the 2-way analysis of variance showed that neither the sterilization method nor the cycles, nor their interaction, were statistically significant. A multipeg may be reused multiple times after sterilization procedures and may be more cost-effective than a disposable smartpeg for checking implant stability after confirming these results in further investigations.<\/jats:p>","DOI":"10.1563\/aaid-joi-d-22-00247","type":"journal-article","created":{"date-parts":[[2024,2,13]],"date-time":"2024-02-13T11:24:04Z","timestamp":1707823444000},"page":"544-547","source":"Crossref","is-referenced-by-count":0,"title":["Influence of Multiple Sterilization on Performance of Titanium Pegs When Measuring Implant Stability With Resonance Frequency Analyses"],"prefix":"10.1563","volume":"49","author":[{"given":"Gokcen","family":"Ates","sequence":"first","affiliation":[{"name":"Faculty of Dentistry, Department of Prosthodontics, Istanbul University, Istanbul, Turkey."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Esma","family":"S\u00f6nmez","sequence":"additional","affiliation":[{"name":"Private Practice, Istanbul, Turkey."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S\u00fcleyman \u00c7a\u011fatay","family":"Dayan","sequence":"additional","affiliation":[{"name":"Program of Dental Technology, Istanbul University, Istanbul, Turkey."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Canan","family":"Bural","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Department of Prosthodontics, Istanbul University, Istanbul, Turkey."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Onur","family":"Geckili","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Department of Prosthodontics, Istanbul University, Istanbul, Turkey."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"434","reference":[{"key":"i1548-1336-49-5-544-b01","series-title":"Clin Oral Implants Res","first-page":"520","article-title":"Predicting osseointegration by means of implant primary stability","volume":"15","author":"Nedir","year":"2004","unstructured":"Nedir\n              R,\n            \n            \n              Bischof\n              M,\n            \n            \n              Szmukler-Moncler\n              S,\n            \n            \n              Bernard\n              JP,\n            \n            \n              Samson\n              J.\n            \n          \n          Predicting osseointegration by means of implant primary stability.\nClin Oral Implants Res.\n2004;\n15:\n520\u2013528."},{"key":"i1548-1336-49-5-544-b02","series-title":"J Oral Biol Craniofac Res","first-page":"629","article-title":"The clinical significance of implant stability quotient (ISQ) measurements: a literature review","volume":"10","author":"Huang","year":"2020","unstructured":"Huang\n              H,\n            \n            \n              Wu\n              G,\n            \n            \n              Hunziker\n              E.\n            \n          \n          The clinical significance of implant stability quotient (ISQ) measurements: a literature review.\nJ Oral Biol Craniofac Res.\n2020;\n10:\n629\u2013638."},{"key":"i1548-1336-49-5-544-b03","series-title":"J Am Dent Assoc","first-page":"483","article-title":"Electronic monitoring of dental implant osseointegration","volume":"133","author":"Dario","year":"2002","unstructured":"Dario\n              LJ,\n            \n            \n              Cucchiaro\n              PJ,\n            \n            \n              Deluzio\n              AJ.\n            \n          \n          Electronic monitoring of dental implant osseointegration.\nJ Am Dent Assoc.\n2002;\n133:\n483\u2013490."},{"key":"i1548-1336-49-5-544-b04","series-title":"Implant Dentistry - A Rapidly Evolving Practice","article-title":"Implant stability \u2013 measuring devices and randomized clinical trial for ISQ value change pattern measured from two different directions by magnetic RFA","author":"L.J. Park","year":"2011","unstructured":"L.J. Park\n              JC,\n            \n            \n              Kim\n              SM,\n            \n            \n              Lee\n              K,\n            \n            \n              Lee\n              JH\n            \n          .\nImplant stability \u2013 measuring devices and randomized clinical trial for ISQ value change pattern measured from two different directions by magnetic RFA. In:TurkyilmazI, ed.\nImplant Dentistry - A Rapidly Evolving Practice.\nEurope: Intech; 2011."},{"key":"i1548-1336-49-5-544-b05","series-title":"Clin Implant Dent Relat Res","first-page":"42","article-title":"The behavior of polyetheretherketone healing abutments when measuring implant stability with electronic percussive testing","volume":"21","author":"Dayan","year":"2019","unstructured":"Dayan\n              \u00c7,\n            \n            \n              Bural\n              C,\n            \n            \n              Ge\u00e7kili\n              O.\n            \n          \n          The behavior of polyetheretherketone healing abutments when measuring implant stability with electronic percussive testing.\nClin Implant Dent Relat Res.\n2019;\n21:\n42\u201345."},{"key":"i1548-1336-49-5-544-b06","series-title":"J Periodontol","first-page":"1786","article-title":"Comparative ex vivo evaluation of two electronic percussive testing devices measuring the stability of dental implants","volume":"85","author":"Geckili","year":"2014","unstructured":"Geckili\n              O,\n            \n            \n              Bilhan\n              H,\n            \n            \n              Cilingir\n              A,\n            \n            et al.\n          \n          Comparative ex vivo evaluation of two electronic percussive testing devices measuring the stability of dental implants.\nJ Periodontol.\n2014;\n85:\n1786\u20131791."},{"key":"i1548-1336-49-5-544-b07","series-title":"J Oral Implantol","first-page":"35","article-title":"Initial stability measurements of implants using a new magnetic resonance frequency analyzer with titanium transducers: an ex vivo study","volume":"46","author":"Bural","year":"2020","unstructured":"Bural\n              C,\n            \n            \n              Dayan\n              C,\n            \n            \n              Ge\u00e7kili\n              O.\n            \n          \n          Initial stability measurements of implants using a new magnetic resonance frequency analyzer with titanium transducers: an ex vivo study.\nJ Oral Implantol.\n2020;\n46:\n35\u201340."},{"key":"i1548-1336-49-5-544-b08","series-title":"Int J Oral Maxillofac Implants","first-page":"1435","article-title":"Primary and secondary stability of implants in postextraction and healed sites: a randomized controlled clinical trial","volume":"31","author":"Malchiodi","year":"2016","unstructured":"Malchiodi\n              L,\n            \n            \n              Balzani\n              L,\n            \n            \n              Cucchi\n              A,\n            \n            \n              Ghensi\n              P,\n            \n            \n              Nocini\n              PF.\n            \n          \n          Primary and secondary stability of implants in postextraction and healed sites: a randomized controlled clinical trial.\nInt J Oral Maxillofac Implants.\n2016;\n31:\n1435\u20131443."},{"key":"i1548-1336-49-5-544-b09","series-title":"Clin Implant Dent Relat Res","first-page":"26","article-title":"Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: a systematic review","volume":"20","author":"Lages","year":"2018","unstructured":"Lages\n              FS,\n            \n            \n              Douglas-de Oliveira\n              DW,\n            \n            \n              Costa\n              FO.\n            \n          \n          Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: a systematic review.\nClin Implant Dent Relat Res.\n2018;\n20:\n26\u201333."},{"key":"i1548-1336-49-5-544-b10","series-title":"Clin Oral Implants Res","first-page":"261","article-title":"Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis","volume":"7","author":"Meredith","year":"1996","unstructured":"Meredith\n              N,\n            \n            \n              Alleyne\n              D,\n            \n            \n              Cawley\n              P.\n            \n          \n          Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis.\nClin Oral Implants Res.\n1996;\n7:\n261\u2013267."},{"key":"i1548-1336-49-5-544-b11","series-title":"Clin Oral Implants Res","first-page":"598","article-title":"Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length","volume":"21","author":"Sim","year":"2010","unstructured":"Sim\n              CP,\n            \n            \n              Lang\n              NP.\n            \n          \n          Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length.\nClin Oral Implants Res.\n2010;\n21:\n598\u2013604."},{"key":"i1548-1336-49-5-544-b12","series-title":"Eur J Oral Sci","first-page":"255","article-title":"Resonance frequency analysis: a new diagnostic tool for dental ankylosis","volume":"120","author":"Bertl","year":"2012","unstructured":"Bertl\n              MH,\n            \n            \n              Weinberger\n              T,\n            \n            \n              Schwarz\n              K,\n            \n            \n              Gruber\n              R,\n            \n            \n              Crismani\n              AG.\n            \n          \n          Resonance frequency analysis: a new diagnostic tool for dental ankylosis.\nEur J Oral Sci.\n2012;\n120:\n255\u2013258."},{"key":"i1548-1336-49-5-544-b13","series-title":"Implant Dent","first-page":"429","article-title":"Reliability of the Osstell implant stability quotient and Penguin resonance frequency analysis to evaluate implant stability","volume":"27","author":"Buyukguclu","year":"2018","unstructured":"Buyukguclu\n              G,\n            \n            \n              Ozkurt-Kayahan\n              Z,\n            \n            \n              Kazazoglu\n              E.\n            \n          \n          Reliability of the Osstell implant stability quotient and Penguin resonance frequency analysis to evaluate implant stability.\nImplant Dent.\n2018;\n27:\n429\u2013433."},{"key":"i1548-1336-49-5-544-b14","series-title":"J Oral Implantol","first-page":"9","article-title":"Comparison of reliability of 3 resonance frequency analysis devices: an in vitro study","volume":"48","author":"Diker","year":"2022","unstructured":"Diker\n              B,\n            \n            \n              Diker\n              N,\n            \n            \n              Tak\n              \u00d6.\n            \n          \n          Comparison of reliability of 3 resonance frequency analysis devices: an in vitro study.\nJ Oral Implantol.\n2022;\n48:\n9\u201314."},{"key":"i1548-1336-49-5-544-b15","series-title":"Int J Oral Maxillofac Implants","article-title":"Resonance frequency analysis: agreement and correlation of implant stability quotients between three commercially available instruments","author":"Norton","year":"2018","unstructured":"Norton\n              MR.\n            \n          \n          Resonance frequency analysis: agreement and correlation of implant stability quotients between three commercially available instruments.\nInt J Oral Maxillofac Implants.\n2018 Oct 3. doi: 10.11607\/jomi.6964"},{"key":"i1548-1336-49-5-544-b16","series-title":"Med Oral Patol Oral Cir Bucal","first-page":"e636","article-title":"Repeatability of the resonance frequency analysis values in implants with a new technology","volume":"24","author":"D\u00edaz-Castro","year":"2019","unstructured":"D\u00edaz-Castro\n              MC,\n            \n            \n              Falcao\n              A,\n            \n            \n              L\u00f3pez-Jarana\n              P,\n            \n            et al.\n          \n          Repeatability of the resonance frequency analysis values in implants with a new technology.\nMed Oral Patol Oral Cir Bucal.\n2019;\n24:\ne636\u2013e642."},{"key":"i1548-1336-49-5-544-b17","series-title":"Clin Implant Dent Relat Res","first-page":"789","article-title":"Resonance frequency analysis with two different devices after conventional implant placement with ridge preservation: a prospective pilot cohort study","volume":"23","author":"Brouwers","year":"2021","unstructured":"Brouwers\n              JEIG,\n            \n            \n              Buis\n              S,\n            \n            \n              de Groot\n              PG,\n            \n            \n              de Laat\n              B,\n            \n            \n              Remijn\n              JA.\n            \n          \n          Resonance frequency analysis with two different devices after conventional implant placement with ridge preservation: a prospective pilot cohort study.\nClin Implant Dent Relat Res.\n2021;\n23:\n789\u2013799."},{"key":"i1548-1336-49-5-544-b18","series-title":"Int J Dent","first-page":"5824369","article-title":"Management of instrument sterilization workflow in endodontics: a systematic review and meta-analysis","volume":"2020","author":"Dioguardi","year":"2020","unstructured":"Dioguardi\n              M,\n            \n            \n              Sovereto\n              D,\n            \n            \n              Illuzzi\n              G,\n            \n            et al.\n          \n          Management of instrument sterilization workflow in endodontics: a systematic review and meta-analysis.\nInt J Dent.\n2020;\n2020:\n5824369."},{"key":"i1548-1336-49-5-544-b19","series-title":"J Hosp Infect","first-page":"237","article-title":"Residual protein levels on reprocessed dental instruments","volume":"61","author":"Smith","year":"2005","unstructured":"Smith\n              A,\n            \n            \n              Letters\n              S,\n            \n            \n              Lange\n              A,\n            \n            \n              Perrett\n              D,\n            \n            \n              McHugh\n              S,\n            \n            \n              Bagg\n              J.\n            \n          \n          Residual protein levels on reprocessed dental instruments.\nJ Hosp Infect.\n2005;\n61:\n237\u2013241."},{"key":"i1548-1336-49-5-544-b20","series-title":"J Hosp Infect","first-page":"233","article-title":"Contaminated dental instruments","volume":"51","author":"Smith","year":"2002","unstructured":"Smith\n              A,\n            \n            \n              Dickson\n              M,\n            \n            \n              Aitken\n              J,\n            \n            \n              Bagg\n              J.\n            \n          \n          Contaminated dental instruments.\nJ Hosp Infect.\n2002;\n51:\n233\u2013235."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/49\/5\/article-p544.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/joi\/article-pdf\/49\/5\/544\/3329202\/i1548-1336-49-5-544.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/49\/5\/article-p544.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/49\/5\/article-p544.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T00:20:28Z","timestamp":1752193228000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/49\/5\/article-p544.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10]]},"references-count":20,"journal-issue":{"issue":"5"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-22-00247","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"type":"electronic","value":"1548-1336"},{"type":"print","value":"0160-6972"}],"subject":[],"published":{"date-parts":[[2023,10]]}}}