{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T08:43:46Z","timestamp":1772181826136,"version":"3.50.1"},"reference-count":27,"publisher":"American Academy of Implant Dentistry","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,2]]},"abstract":"<jats:p>The stability of implant-abutment joint is fundamental for the long-term success of implant rehabilitation. The screw loosening, fracture, and head deformation are among the most common mechanical complications. Several surface treatments of titanium screws have been proposed to improve their resistance and stability. Diamond-like carbon (DLC) coating of the materials is widely used to increase their wear resistance and durability. The present study aimed to evaluate the effect of carbon fiber coating on the screw head on screw removal torque and screw head stripping. One hundred titanium implant screws were used, 50 without coating (Group 1) and 50 with DLC coating of the screw head (Group 2). Each screw was tightened with a torque of 25 Ncm and unscrewed 10 times. The removal torque was measured with a digital cap torque tester for each loosening. Optical 3d measurement of the screw head surface was performed by a fully automatic machine before and after multiple tightening to investigate surface modifications. The reverse torque values decreased with repeated tightening and loosening cycles in both groups without significant differences (<jats:italic>P<\/jats:italic> &gt; .05). Optical measurements of surface dimensions revealed average changes of 0.0357 mm in Group 1 and 0.02312 mm in Group 2, which resulted to be statistically significant (<jats:italic>P<\/jats:italic> &lt; .001). The DLC coating of the retention screw head can prevent its distortion and wear, especially after multiple tightening.<\/jats:p>","DOI":"10.1563\/aaid-joi-d-23-00072","type":"journal-article","created":{"date-parts":[[2024,4,5]],"date-time":"2024-04-05T13:18:10Z","timestamp":1712323090000},"page":"45-49","source":"Crossref","is-referenced-by-count":1,"title":["Diamond-Like Carbon Coating Reduces Connection Screw Head Stripping After Multiple Tightening Instances"],"prefix":"10.1563","volume":"50","author":[{"given":"Francesco","family":"Pera","sequence":"first","affiliation":[{"name":"Department of Surgical Sciences, CIR Dental School, University of Turin, Turin, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Byung Chan","family":"Kim","sequence":"additional","affiliation":[{"name":"Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paolo","family":"Pesce","sequence":"additional","affiliation":[{"name":"Department of Surgical Sciences, University of Genova, Genova, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria","family":"Menini","sequence":"additional","affiliation":[{"name":"Department of Surgical Sciences, University of Genova, Genova, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Giuseppe","family":"Troiano","sequence":"additional","affiliation":[{"name":"Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Khrystyna","family":"Zhurakivska","sequence":"additional","affiliation":[{"name":"Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"434","reference":[{"key":"i1548-1336-50-1-45-b01","series-title":"Periodontol 2000","first-page":"7","article-title":"Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions","volume":"73","author":"Buser","year":"2017","unstructured":"Buser\n              D,\n            \n            \n              Sennerby\n              L,\n            \n            \n              De Bruyn\n              H.\n            \n          \n          Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions. Periodontol 2000. 2017;73:7\u201321. doi:10.1111\/prd.12185"},{"key":"i1548-1336-50-1-45-b02","series-title":"J Prosthet Dent","first-page":"121","article-title":"Clinical complications with implants and implant prostheses","volume":"90","author":"Goodacre","year":"2003","unstructured":"Goodacre\n              CJ,\n            \n            \n              Bernal\n              G,\n            \n            \n              Rungcharassaeng\n              K,\n            \n            \n              Kan\n              JY.\n            \n          \n          Clinical complications with implants and implant prostheses. J Prosthet Dent. 2003;90:121\u2013132. doi:10.1016\/s0022-3913(03)00212-9"},{"key":"i1548-1336-50-1-45-b03","series-title":"J Biomed Mater Res B Appl Biomater","first-page":"457","article-title":"Influence of implant\/abutment joint designs on abutment screw loosening in a dental implant system","volume":"75","author":"Kitagawa","year":"2005","unstructured":"Kitagawa\n              T,\n            \n            \n              Tanimoto\n              Y,\n            \n            \n              Odaki\n              M,\n            \n            \n              Nemoto\n              K,\n            \n            \n              Aida\n              M.\n            \n          \n          Influence of implant\/abutment joint designs on abutment screw loosening in a dental implant system. J Biomed Mater Res B Appl Biomater. 2005;75:457\u2013463. doi:10.1002\/jbm.b.30328"},{"key":"i1548-1336-50-1-45-b04","series-title":"J Oral Implantol","first-page":"146","article-title":"The effect of different implant-abutment connections on screw joint stability","volume":"40","author":"Michalakis","year":"2014","unstructured":"Michalakis\n              KX,\n            \n            \n              Calvani\n              P,\n            \n            \n              Muftu\n              S,\n            \n            \n              Pissiotis\n              A,\n            \n            \n              Hirayama\n              H.\n            \n          \n          The effect of different implant-abutment connections on screw joint stability. J Oral Implantol. 2014;40:146\u2013152."},{"issue":"1","key":"i1548-1336-50-1-45-b05","series-title":"J Prosthet Dent","first-page":"74","article-title":"The influence of abutment screw tightening on screw joint configuration","volume":"87","author":"Lang","year":"2002","unstructured":"Lang\n              LA,\n            \n            \n              Wang\n              R-F,\n            \n            \n              May\n              KB.\n            \n          \n          The influence of abutment screw tightening on screw joint configuration. J Prosthet Dent. 2002;87(1):74\u201379."},{"key":"i1548-1336-50-1-45-b06","series-title":"J Adv Prosthodont","first-page":"126","article-title":"Influence of the implant-abutment connection design and diameter on the screw joint stability","volume":"6","author":"Shin","year":"2014","unstructured":"Shin\n              H-M,\n            \n            \n              Huh\n              J-B,\n            \n            \n              Yun\n              M-J,\n            \n            \n              Jeon\n              Y-C,\n            \n            \n              Chang\n              BM,\n            \n            \n              Jeong\n              C-M.\n            \n          \n          Influence of the implant-abutment connection design and diameter on the screw joint stability. J Adv Prosthodont. 2014;6:126\u2013132."},{"key":"i1548-1336-50-1-45-b07","series-title":"Implant Dent","first-page":"46","article-title":"Preload evaluation of different screws in external hexagon joint","volume":"21","author":"Assun\u00e7\u00e3o","year":"2012","unstructured":"Assun\u00e7\u00e3o\n              WG,\n            \n            \n              Delben\n              JA,\n            \n            \n              Tabata\n              LF,\n            \n            \n              Bar\u00e3o\n              VAR,\n            \n            \n              Gomes\n              \u00c9A,\n            \n            \n              Garcia Jr\n              IR.\n            \n          \n          Preload evaluation of different screws in external hexagon joint. Implant Dent. 2012;21:46\u201350."},{"key":"i1548-1336-50-1-45-b08","series-title":"J Mech Behav Biomed Mater","first-page":"30","article-title":"Mechanical biocompatibilities of titanium alloys for biomedical applications","volume":"1","author":"Niinomi","year":"2008","unstructured":"Niinomi\n              M.\n            \n          \n          Mechanical biocompatibilities of titanium alloys for biomedical applications. J Mech Behav Biomed Mater. 2008;1:30\u201342."},{"key":"i1548-1336-50-1-45-b09","series-title":"J Prosthet Dent","first-page":"212","article-title":"Retrieval of a stripped abutment screw: a clinical report","volume":"104","author":"Maalhagh-Fard","year":"2010","unstructured":"Maalhagh-Fard\n              A,\n            \n            \n              Jacobs\n              LC.\n            \n          \n          Retrieval of a stripped abutment screw: a clinical report. J Prosthet Dent. 2010;104:212\u2013215. doi:10.1016\/S0022-3913(10)00133-2"},{"key":"i1548-1336-50-1-45-b10","series-title":"J Prosthodont","first-page":"330","article-title":"Management of a fractured multiunit maxillary implant-supported fixed prosthesis with stripped abutment screws using a hybrid cement-retained and screw-retained design: a 5-year follow-up clinical report","volume":"25","author":"Al Amri","year":"2016","unstructured":"Al Amri\n              MD.\n            \n          \n          Management of a fractured multiunit maxillary implant-supported fixed prosthesis with stripped abutment screws using a hybrid cement-retained and screw-retained design: a 5-year follow-up clinical report. J Prosthodont. 2016;25:330\u2013334. doi:10.1111\/jopr.12433"},{"key":"i1548-1336-50-1-45-b11","series-title":"Surf Coat Tech","first-page":"214","article-title":"History of diamond-like carbon films\u2014From first experiments to worldwide applications","volume":"242","author":"Bewilogua","year":"2014","unstructured":"Bewilogua\n              K,\n            \n            \n              Hofmann\n              D.\n            \n          \n          History of diamond-like carbon films\u2014From first experiments to worldwide applications. Surf Coat Tech. 2014;242:214\u2013225. doi:https:\/\/doi.org\/10.1016\/j.surfcoat.2014.01.031"},{"key":"i1548-1336-50-1-45-b12","series-title":"Tribol Int","first-page":"991","article-title":"An overview on the tribological behavior of diamond-like carbon in technical and medical applications","volume":"37","author":"Hauert","year":"2004","unstructured":"Hauert\n              R.\n            \n          \n          An overview on the tribological behavior of diamond-like carbon in technical and medical applications. Tribol Int. 2004;37:991\u20131003. doi:https:\/\/doi.org\/10.1016\/j.triboint.2004.07.017"},{"key":"i1548-1336-50-1-45-b13","series-title":"Thin Solid Films","first-page":"84","article-title":"Diamond-like carbon films for PET bottles and medical applications","volume":"494","author":"Shirakura","year":"2006","unstructured":"Shirakura\n              A,\n            \n            \n              Nakaya\n              M,\n            \n            \n              Koga\n              Y,\n            \n            \n              Kodama\n              H,\n            \n            \n              Hasebe\n              T,\n            \n            \n              Suzuki\n              T.\n            \n          \n          Diamond-like carbon films for PET bottles and medical applications. Thin Solid Films. 2006;494:84\u201391. doi:https:\/\/doi.org\/10.1016\/j.tsf.2005.08.366"},{"key":"i1548-1336-50-1-45-b14","series-title":"J Oral Rehabil","first-page":"346","article-title":"An abutment screw loosening study of a Diamond Like Carbon\u2010coated CP titanium implant","volume":"32","author":"Kim","year":"2005","unstructured":"Kim\n              S,\n            \n            \n              Lee\n              J,\n            \n            \n              Koak\n              J,\n            \n            et al.\n          An abutment screw loosening study of a Diamond Like Carbon\u2010coated CP titanium implant. J Oral Rehabil. 2005;32:346\u2013350."},{"key":"i1548-1336-50-1-45-b15","series-title":"Braz Dent J","first-page":"317","article-title":"Analyses of biofilm on implant abutment surfaces coating with diamond-like carbon and biocompatibility","volume":"28","author":"Huacho","year":"2017","unstructured":"Huacho\n              PMM,\n            \n            \n              Nogueira\n              MNM,\n            \n            \n              Basso\n              FG,\n            \n            \n              Jafelicci Junior\n              M,\n            \n            \n              Francisconi\n              RS,\n            \n            \n              Spolidorio\n              DMP.\n            \n          \n          Analyses of biofilm on implant abutment surfaces coating with diamond-like carbon and biocompatibility. Braz Dent J. 2017;28:317\u2013323. doi:10.1590\/0103-6440201601136"},{"key":"i1548-1336-50-1-45-b16","series-title":"Int J Prosthodont","first-page":"401","article-title":"Effect of surface modifications of abutment screws on reverse torque values: an in vitro study","volume":"33","author":"Colpak","year":"2020","unstructured":"Colpak\n              ED,\n            \n            \n              Gumus\n              HO.\n            \n          \n          Effect of surface modifications of abutment screws on reverse torque values: an in vitro study. Int J Prosthodont. 2020;33:401\u2013409. doi:10.11607\/ijp.6581"},{"key":"i1548-1336-50-1-45-b17","series-title":"J Prosthodont","first-page":"458","article-title":"Effects of abutment screw coating on implant preload","volume":"19","author":"Park","year":"2010","unstructured":"Park\n              JK,\n            \n            \n              Choi\n              JU,\n            \n            \n              Jeon\n              YC,\n            \n            \n              Choi\n              KS,\n            \n            \n              Jeong\n              CM.\n            \n          \n          Effects of abutment screw coating on implant preload. J Prosthodont. 2010;19:458\u2013464."},{"key":"i1548-1336-50-1-45-b18","series-title":"J Adv Prosthodont","first-page":"375","article-title":"Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating","volume":"7","author":"Bacchi","year":"2015","unstructured":"Bacchi\n              A,\n            \n            \n              Regalin\n              A,\n            \n            \n              Bhering\n              CL,\n            \n            \n              Alessandretti\n              R,\n            \n            \n              Spazzin\n              AO.\n            \n          \n          Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating. J Adv Prosthodont. 2015;7:375\u2013379. doi:10.4047\/jap.2015.7.5.375"},{"key":"i1548-1336-50-1-45-b19","series-title":"Dent Mater","first-page":"e265","article-title":"Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: in-vitro study","volume":"35","author":"Sammour","year":"2019","unstructured":"Sammour\n              SR,\n            \n            \n              Maamoun El-Sheikh\n              M,\n            \n            \n              Aly El-Gendy\n              A.\n            \n          \n          Effect of implant abutment connection designs, and implant diameters on screw loosening before and after cyclic loading: in-vitro study. Dent Mater. 2019;35:e265\u2013e271. doi:10.1016\/j.dental.2019.07.026"},{"key":"i1548-1336-50-1-45-b20","series-title":"Stata Statistical Software: Release 16","author":"StataCorp","year":"2019","unstructured":"StataCorp\n          . 2019. Stata Statistical Software: Release 16. College Station, TX."},{"key":"i1548-1336-50-1-45-b21","series-title":"J Prosthodont","first-page":"164","article-title":"Preloads generated with repeated tightening in three types of screws used in dental implant assemblies","volume":"15","author":"Byrne","year":"2006","unstructured":"Byrne\n              D,\n            \n            \n              Jacobs\n              S,\n            \n            \n              O\u2019Connell\n              B,\n            \n            \n              Houston\n              F,\n            \n            \n              Claffey\n              N.\n            \n          \n          Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. J Prosthodont. 2006;15:164\u2013171."},{"key":"i1548-1336-50-1-45-b22","series-title":"Int J Oral Maxillofac Implants","first-page":"529","article-title":"Elongation and preload stress in dental implant abutment screws","volume":"10","author":"Haack","year":"1995","unstructured":"Haack\n              JE,\n            \n            \n              Sakaguchi\n              RL,\n            \n            \n              Sun\n              T,\n            \n            \n              Coffey\n              JP.\n            \n          \n          Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofac Implants. 1995;10:529\u2013536."},{"key":"i1548-1336-50-1-45-b23","series-title":"J Prosthet Dent","first-page":"194","article-title":"Effect of repeated closures on opening torque values in seven abutment-implant systems","volume":"84","author":"Weiss","year":"2000","unstructured":"Weiss\n              EI,\n            \n            \n              Kozak\n              D,\n            \n            \n              Gross\n              MD,\n            \n            \n              Maurice\n              T.\n            \n          \n          Effect of repeated closures on opening torque values in seven abutment-implant systems. J Prosthet Dent. 2000;84:194\u2013199."},{"key":"i1548-1336-50-1-45-b24","series-title":"J Korean Acad Prosthodont","first-page":"628","article-title":"Changes of abutment screw after repeated closing and opening","volume":"42","author":"Kim","year":"2004","unstructured":"Kim\n              H-J,\n            \n            \n              Chung\n              C-H,\n            \n            \n              Choe\n              H-C,\n            \n            \n              Oh\n              S-H.\n            \n          \n          Changes of abutment screw after repeated closing and opening. J Korean Acad Prosthodont. 2004;42:628\u2013640."},{"key":"i1548-1336-50-1-45-b25","series-title":"Int J Dent","first-page":"9693239","article-title":"Analysis of torque maintenance and fracture resistance after fatigue in retention screws made of different metals for screw-retained implant-borne prosthesis joints","volume":"2021","author":"Bello Taborda","year":"2021","unstructured":"Bello Taborda\n              MB,\n            \n            \n              Yaguinuma Gon\u00e7alves\n              GS,\n            \n            \n              Alves de Sousa\n              C,\n            \n            \n              Gon\u00e7alves Assun\u00e7\u00e3o\n              W.\n            \n          \n          Analysis of torque maintenance and fracture resistance after fatigue in retention screws made of different metals for screw-retained implant-borne prosthesis joints. Int J Dent. 2021;2021:9693239. doi:10.1155\/2021\/9693239"},{"key":"i1548-1336-50-1-45-b26","series-title":"J Biomed Mater Res Part B Appl Biomater","first-page":"72","article-title":"Biomedical applications of diamond\u2010like carbon coatings: a review","volume":"83","author":"Roy","year":"2007","unstructured":"Roy\n              RK,\n            \n            \n              Lee\n              KR.\n            \n          \n          Biomedical applications of diamond\u2010like carbon coatings: a review. J Biomed Mater Res Part B Appl Biomater. 2007;83:72\u201384."},{"key":"i1548-1336-50-1-45-b27","series-title":"Int J Oral Maxillofac Implants","article-title":"Influence of diamondlike carbon-coated screws on the implant-abutment interface","volume":"27","author":"Diez","year":"2012","unstructured":"Diez\n              JSV,\n            \n            \n              Brigagao\n              VC,\n            \n            \n              Cunha\n              LG,\n            \n            \n              Neves\n              ACC.\n            \n          \n          Influence of diamondlike carbon-coated screws on the implant-abutment interface. Int J Oral Maxillofac Implants. 2012;27."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/50\/1\/article-p45.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/joi\/article-pdf\/50\/1\/45\/3351980\/i1548-1336-50-1-45.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/50\/1\/article-p45.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/50\/1\/article-p45.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T00:21:35Z","timestamp":1752193295000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/50\/1\/article-p45.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2]]},"references-count":27,"aliases":["10.1563\/aaid-joi-d-23-00072r3"],"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-23-00072","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"value":"1548-1336","type":"electronic"},{"value":"0160-6972","type":"print"}],"subject":[],"published":{"date-parts":[[2024,2]]}}}