{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,5]],"date-time":"2025-11-05T21:18:22Z","timestamp":1762377502279,"version":"3.41.2"},"reference-count":39,"publisher":"American Academy of Implant Dentistry","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2024,4]]},"abstract":"<jats:p>Although a smaller size field of view (FOV) of cone-beam computerized tomography (CBCT) reduces radiation exposure, its effect on the accuracy of static computer-aided implant surgery (s-CAIS) remains unknown. This study aimed to evaluate the impact of the size of FOV on the accuracy of s-CAIS and to investigate if the arch affects this effect. A total of 32 implant sites on 8 identical scannable models (maxillae and mandibles) were randomly allocated to 2 FOV sizes: test (5 \u00d7 5 cm) and control (10 \u00d7 10 cm). All models were scanned with an intraoral scanner (IOS). With the registration of the surface scan and CBCT image, a prosthetic-driven implant position was planned. Following the fabrication of surgical templates, a single-blinded surgeon placed all implants with the fully guided s-CAIS protocol. IOS captured the implant positions with the scan body attached. Implant-planning software measured the angular deviation, 3-dimensional (3D) deviation at the crest, and 3D deviation at the apex between preplanned and actual implant positions. Two-way analysis of variance was used to analyze the effect of FOV and arch on the deviations. The size of FOV did not show a significant effect (<jats:italic>P<\/jats:italic> &gt; .198) on angular deviation, 3D deviation at the crest, or 3D deviation at the apex. No significant difference was found when comparing the effect of the size of FOV between the maxillary and mandibular implants. In conclusion, the use of small FOV CBCT demonstrated comparable accuracy of s-CAIS to the use of medium FOV CBCT.<\/jats:p>","DOI":"10.1563\/aaid-joi-d-23-00076","type":"journal-article","created":{"date-parts":[[2024,2,24]],"date-time":"2024-02-24T07:14:36Z","timestamp":1708758876000},"page":"111-118","source":"Crossref","is-referenced-by-count":1,"title":["The Accuracy of Guided Implant Surgery With Different Fields of View of Cone-Beam Computerized Tomography"],"prefix":"10.1563","volume":"50","author":[{"given":"Hsin-Chiang","family":"Lee","sequence":"first","affiliation":[{"name":"Department of Periodontology, Indiana University School of Dentistry, Indianapolis, Indiana, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lan-Lin","family":"Chiou","sequence":"additional","affiliation":[{"name":"Division of Periodontology, University of Connecticut School of Dental Medicine, Farmington, Connecticut, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chao-Chieh","family":"Yang","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei-Shao","family":"Lin","sequence":"additional","affiliation":[{"name":"Department of Prosthodontics, Indiana University School of Dentistry, Indianapolis, Indiana, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vinicius","family":"Dutra","sequence":"additional","affiliation":[{"name":"Department Oral Pathology, Medicine, and Radiology, Indiana University School of Dentistry, Indianapolis, Indiana, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yusuke","family":"Hamada","sequence":"additional","affiliation":[{"name":"Section of Periodontics, UCLA School of Dentistry, Los Angeles, California, USA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"434","reference":[{"key":"i1548-1336-50-2-111-b01","series-title":"Clin Implant Dent Relat Res","first-page":"828","article-title":"10-year follow-up of immediately loaded implants with TiUnite porous anodized surface","volume":"14","author":"Degidi","year":"2012","unstructured":"Degidi\n              M,\n            \n            \n              Nardi\n              D,\n            \n            \n              Piattelli\n              A.\n            \n          \n          10-year follow-up of immediately loaded implants with TiUnite porous anodized surface. \nClin Implant Dent Relat Res. \n2012;14:\n828\u2013838."},{"key":"i1548-1336-50-2-111-b02","series-title":"Clin Implant Dent Relat Res","first-page":"80","article-title":"A 10-year prospective study of single tooth implants placed in the anterior maxilla","volume":"14","author":"Gotfredsen","year":"2012","unstructured":"Gotfredsen\n              K.\n            \n          \n          A 10-year prospective study of single tooth implants placed in the anterior maxilla. \nClin Implant Dent Relat Res. \n2012;14:\n80\u201387."},{"key":"i1548-1336-50-2-111-b03","series-title":"Clin Implant Dent Relat Res","first-page":"808","article-title":"Prospective 10-year cohort study based on a randomized controlled trial (RCT) on implant-supported full-arch maxillary prostheses. Part 1: sandblasted and acid-etched implants and mucosal tissue","volume":"14","author":"Fischer","year":"2012","unstructured":"Fischer\n              K,\n            \n            \n              Stenberg\n              T.\n            \n          \n          Prospective 10-year cohort study based on a randomized controlled trial (RCT) on implant-supported full-arch maxillary prostheses. Part 1: sandblasted and acid-etched implants and mucosal tissue. \nClin Implant Dent Relat Res. \n2012;14:\n808\u2013815."},{"issue":"suppl","key":"i1548-1336-50-2-111-b04","series-title":"Int J Oral Maxillofac Implants","first-page":"25","article-title":"Computer technology applications in surgical implant dentistry: a systematic review","volume":"29","author":"Tahmaseb","year":"2014","unstructured":"Tahmaseb\n              A,\n            \n            \n              Wismeijer\n              D,\n            \n            \n              Coucke\n              W,\n            \n            \n              Derksen\n              W.\n            \n          \n          Computer technology applications in surgical implant dentistry: a systematic review. \nInt J Oral Maxillofac Implants. \n2014;29(suppl):\n25\u201342."},{"key":"i1548-1336-50-2-111-b05","series-title":"Clin Oral Implants Res","first-page":"1022","article-title":"The anterior loop of the inferior alveolar nerve: prevalence, measurement of its length and a recommendation for interforaminal implant installation based on cone beam CT imaging","volume":"23","author":"Apostolakis","year":"2012","unstructured":"Apostolakis\n              D,\n            \n            \n              Brown\n              JE.\n            \n          \n          The anterior loop of the inferior alveolar nerve: prevalence, measurement of its length and a recommendation for interforaminal implant installation based on cone beam CT imaging. \nClin Oral Implants Res. \n2012;23:\n1022\u20131030."},{"key":"i1548-1336-50-2-111-b06","series-title":"J Periodontol","first-page":"1933","article-title":"The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: a literature review","volume":"77","author":"Greenstein","year":"2006","unstructured":"Greenstein\n              G,\n            \n            \n              Tarnow\n              D.\n            \n          \n          The mental foramen and nerve: clinical and anatomical factors related to dental implant placement: a literature review. \nJ Periodontol. \n2006;77:\n1933\u20131943."},{"issue":"suppl 6","key":"i1548-1336-50-2-111-b07","series-title":"Clin Oral Implants Res","first-page":"163","article-title":"Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates","volume":"23","author":"Sailer","year":"2012","unstructured":"Sailer\n              I,\n            \n            \n              Muhlemann\n              S,\n            \n            \n              Zwahlen\n              M,\n            \n            \n              Hammerle\n              CH,\n            \n            \n              Schneider\n              D.\n            \n          \n          Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates. \nClin Oral Implants Res. \n2012;23(suppl 6):\n163\u2013201."},{"issue":"suppl 1","key":"i1548-1336-50-2-111-b08","series-title":"J Periodontol","first-page":"S267","article-title":"Peri-implantitis","volume":"89","author":"Schwarz","year":"2018","unstructured":"Schwarz\n              F,\n            \n            \n              Derks\n              J,\n            \n            \n              Monje\n              A,\n            \n            \n              Wang\n              HL.\n            \n          \n          Peri-implantitis. \nJ Periodontol. \n2018;89(suppl 1):\nS267\u2013S290."},{"key":"i1548-1336-50-2-111-b09","series-title":"Periodontol 2000","first-page":"214","article-title":"Different techniques of static\/dynamic guided implant surgery: modalities and indications","volume":"66","author":"Vercruyssen","year":"2014","unstructured":"Vercruyssen\n              M,\n            \n            \n              Fortin\n              T,\n            \n            \n              Widmann\n              G,\n            \n            \n              Jacobs\n              R,\n            \n            \n              Quirynen\n              M.\n            \n          \n          Different techniques of static\/dynamic guided implant surgery: modalities and indications. \nPeriodontol 2000. \n2014;66:\n214\u2013227."},{"issue":"suppl","key":"i1548-1336-50-2-111-b10","series-title":"Int J Oral Maxillofac Implants","first-page":"92","article-title":"Computer technology applications in surgical implant dentistry: a systematic review","volume":"24","author":"Jung","year":"2009","unstructured":"Jung\n              RE,\n            \n            \n              Schneider\n              D,\n            \n            \n              Ganeles\n              J,\n            \n            et al.\n          \n          Computer technology applications in surgical implant dentistry: a systematic review. \nInt J Oral Maxillofac Implants. \n2009;24(suppl):\n92\u2013109."},{"key":"i1548-1336-50-2-111-b11","series-title":"Periodontol 2000","first-page":"121","article-title":"Current state of the art of computer-guided implant surgery","volume":"73","author":"D\u2019Haese","year":"2017","unstructured":"D\u2019Haese\n              J,\n            \n            \n              Ackhurst\n              J,\n            \n            \n              Wismeijer\n              D,\n            \n            \n              De Bruyn\n              H,\n            \n            \n              Tahmaseb\n              A.\n            \n          \n          Current state of the art of computer-guided implant surgery. \nPeriodontol 2000. \n2017;73:\n121\u2013133."},{"key":"i1548-1336-50-2-111-b12","series-title":"Int J Oral Maxillofac Implants","first-page":"1159","article-title":"Fully guided versus half-guided and freehand implant placement: systematic review and meta-analysis","volume":"35","author":"Gargallo-Albiol","year":"2020","unstructured":"Gargallo-Albiol\n              J,\n            \n            \n              Barootchi\n              S,\n            \n            \n              Marques-Guasch\n              J,\n            \n            \n              Wang\n              HL.\n            \n          \n          Fully guided versus half-guided and freehand implant placement: systematic review and meta-analysis. \nInt J Oral Maxillofac Implants. \n2020;35:\n1159\u20131169."},{"key":"i1548-1336-50-2-111-b13","series-title":"Int J Oral Maxillofac Implants","first-page":"101","article-title":"Accuracy of implant placement with computer-guided surgery: a systematic review and meta-analysis comparing cadaver, clinical, and in vitro studies","volume":"33","author":"Bover-Ramos","year":"2018","unstructured":"Bover-Ramos\n              F,\n            \n            \n              Vina-Almunia\n              J,\n            \n            \n              Cervera-Ballester\n              J,\n            \n            \n              Penarrocha-Diago\n              M,\n            \n            \n              Garcia-Mira\n              B.\n            \n          \n          Accuracy of implant placement with computer-guided surgery: a systematic review and meta-analysis comparing cadaver, clinical, and in vitro studies. \nInt J Oral Maxillofac Implants. \n2018;33:\n101\u2013115."},{"key":"i1548-1336-50-2-111-b14","series-title":"Periodontol 2000","first-page":"194","article-title":"Guided implant surgery risks and their prevention","volume":"81","author":"Tatakis","year":"2019","unstructured":"Tatakis\n              DN,\n            \n            \n              Chien\n              HH,\n            \n            \n              Parashis\n              AO.\n            \n          \n          Guided implant surgery risks and their prevention. \nPeriodontol 2000. \n2019;81:\n194\u2013208."},{"key":"i1548-1336-50-2-111-b15","series-title":"Int J Oral Maxillofac Implants","first-page":"527","article-title":"Cone beam computed tomography vs multislice computed tomography in computer-aided design\/computer-assisted manufacture guided implant surgery based on three-dimensional optical scanning and stereolithographic guides: does image modality matter?","volume":"31","author":"Widmann","year":"2016","unstructured":"Widmann\n              G,\n            \n            \n              Fischer\n              B,\n            \n            \n              Berggren\n              JP,\n            \n            et al.\n          \n          Cone beam computed tomography vs multislice computed tomography in computer-aided design\/computer-assisted manufacture guided implant surgery based on three-dimensional optical scanning and stereolithographic guides: does image modality matter?\n          \n            Int J Oral Maxillofac Implants\n          . \n2016;31:\n527\u2013533."},{"key":"i1548-1336-50-2-111-b16","series-title":"Int J Oral Maxillofac Surg","first-page":"377","article-title":"Accuracy of implant position when placed using static computer-assisted implant surgical guides manufactured with two different optical scanning techniques: a randomized clinical trial","volume":"49","author":"Kiatkroekkrai","year":"2020","unstructured":"Kiatkroekkrai\n              P,\n            \n            \n              Takolpuckdee\n              C,\n            \n            \n              Subbalekha\n              K,\n            \n            \n              Mattheos\n              N,\n            \n            \n              Pimkhaokham\n              A.\n            \n          \n          Accuracy of implant position when placed using static computer-assisted implant surgical guides manufactured with two different optical scanning techniques: a randomized clinical trial. \nInt J Oral Maxillofac Surg. \n2020;49:\n377\u2013383."},{"key":"i1548-1336-50-2-111-b17","series-title":"Clin Oral Implants Res","first-page":"1113","article-title":"Registration of cone beam computed tomography data and intraoral surface scans\u2014a prerequisite for guided implant surgery with CAD\/CAM drilling guides","volume":"28","author":"Flugge","year":"2017","unstructured":"Flugge\n              T,\n            \n            \n              Derksen\n              W,\n            \n            \n              Te Poel\n              J,\n            \n            \n              Hassan\n              B,\n            \n            \n              Nelson\n              K,\n            \n            \n              Wismeijer\n              D.\n            \n          \n          Registration of cone beam computed tomography data and intraoral surface scans\u2014a prerequisite for guided implant surgery with CAD\/CAM drilling guides. \nClin Oral Implants Res. \n2017;28:\n1113\u20131118."},{"key":"i1548-1336-50-2-111-b18","series-title":"Clin Oral Implants Res","first-page":"763","article-title":"Accuracy of full guided vs. half-guided implant surgery","volume":"24","author":"Kuhl","year":"2013","unstructured":"Kuhl\n              S,\n            \n            \n              Zurcher\n              S,\n            \n            \n              Mahid\n              T,\n            \n            \n              Muller-Gerbl\n              M,\n            \n            \n              Filippi\n              A,\n            \n            \n              Cattin\n              P.\n            \n          \n          Accuracy of full guided vs. half-guided implant surgery. \nClin Oral Implants Res. \n2013;24:\n763\u2013769."},{"key":"i1548-1336-50-2-111-b19","series-title":"J Craniomaxillofac Surg","first-page":"804","article-title":"The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template","volume":"45","author":"Matta","year":"2017","unstructured":"Matta\n              RE,\n            \n            \n              Bergauer\n              B,\n            \n            \n              Adler\n              W,\n            \n            \n              Wichmann\n              M,\n            \n            \n              Nickenig\n              HJ.\n            \n          \n          The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template. \nJ Craniomaxillofac Surg. \n2017;45:\n804\u2013808."},{"key":"i1548-1336-50-2-111-b20","series-title":"Dentomaxillofac Radiol","first-page":"20140197","article-title":"Effective dose of dental CBCT\u2014a meta analysis of published data and additional data for nine CBCT units","volume":"44","author":"Ludlow","year":"2015","unstructured":"Ludlow\n              JB,\n            \n            \n              Timothy\n              R,\n            \n            \n              Walker\n              C,\n            \n            et al.\n          \n          Effective dose of dental CBCT\u2014a meta analysis of published data and additional data for nine CBCT units. \nDentomaxillofac Radiol. \n2015;44:\n20140197."},{"key":"i1548-1336-50-2-111-b21","series-title":"Imaging Sci Dent","first-page":"263","article-title":"Cone-beam computed tomography: time to move from ALARA to ALADA","volume":"45","author":"Jaju","year":"2015","unstructured":"Jaju\n              PP,\n            \n            \n              Jaju\n              SP.\n            \n          \n          Cone-beam computed tomography: time to move from ALARA to ALADA. \nImaging Sci Dent. \n2015;45:\n263\u2013265."},{"key":"i1548-1336-50-2-111-b22","series-title":"Clin Oral Implants Res","first-page":"1201","article-title":"Cone beam imaging: is this the ultimate imaging modality?","volume":"21","author":"Koong","year":"2010","unstructured":"Koong\n              B.\n            \n          \n          Cone beam imaging: is this the ultimate imaging modality?\n          \n            Clin Oral Implants Res\n          . \n2010;21:\n1201\u20131208."},{"key":"i1548-1336-50-2-111-b23","series-title":"Eur J Radiol","first-page":"267","article-title":"Effective dose range for dental cone beam computed tomography scanners","volume":"81","author":"Pauwels","year":"2012","unstructured":"Pauwels\n              R,\n            \n            \n              Beinsberger\n              J,\n            \n            \n              Collaert\n              B,\n            \n            et al.\n          \n          Effective dose range for dental cone beam computed tomography scanners. \nEur J Radiol. \n2012;81:\n267\u2013271."},{"key":"i1548-1336-50-2-111-b24","series-title":"J Periodontol","first-page":"946","article-title":"The use of cone-beam computed tomography in management of patients requiring dental implants: an American Academy of Periodontology best evidence review","volume":"88","author":"Rios","year":"2017","unstructured":"Rios\n              HF,\n            \n            \n              Borgnakke\n              WS,\n            \n            \n              Benavides\n              E.\n            \n          \n          The use of cone-beam computed tomography in management of patients requiring dental implants: an American Academy of Periodontology best evidence review. \nJ Periodontol. \n2017;88:\n946\u2013959."},{"key":"i1548-1336-50-2-111-b25","series-title":"Int J Prosthodont","first-page":"277","article-title":"Precision of dental implant digitization using intraoral scanners","volume":"29","author":"Fl\u00fcgge","year":"2016","unstructured":"Fl\u00fcgge\n              TV,\n            \n            \n              Att\n              W,\n            \n            \n              Metzger\n              MC,\n            \n            \n              Nelson\n              K.\n            \n          \n          Precision of dental implant digitization using intraoral scanners. \nInt J Prosthodont. \n2016;29:\n277\u2013283."},{"key":"i1548-1336-50-2-111-b26","series-title":"Oral Surg Oral Med Oral Pathol Oral Radiol","first-page":"277","article-title":"Radiation risk in low-dose maxillofacial radiography","volume":"114","author":"Scarfe","year":"2012","unstructured":"Scarfe\n              WC.\n            \n          \n          Radiation risk in low-dose maxillofacial radiography. \nOral Surg Oral Med Oral Pathol Oral Radiol. \n2012;114:\n277\u2013280."},{"key":"i1548-1336-50-2-111-b27","series-title":"Front Genet","first-page":"260","article-title":"Sex difference of radiation response in occupational and accidental exposure","volume":"10","author":"Narendran","year":"2019","unstructured":"Narendran\n              N,\n            \n            \n              Luzhna\n              L,\n            \n            \n              Kovalchuk\n              O.\n            \n          \n          Sex difference of radiation response in occupational and accidental exposure. \nFront Genet. \n2019;10:\n260."},{"key":"i1548-1336-50-2-111-b28","series-title":"Imaging Sci Dent","first-page":"93","article-title":"The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions","volume":"46","author":"Ganguly","year":"2016","unstructured":"Ganguly\n              R,\n            \n            \n              Ramesh\n              A,\n            \n            \n              Pagni\n              S.\n            \n          \n          The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions. \nImaging Sci Dent. \n2016;46:\n93\u2013101."},{"key":"i1548-1336-50-2-111-b29","series-title":"Dentomaxillofac Radiol","first-page":"20160377","article-title":"Accuracy of linear measurements around dental implants by means of cone beam computed tomography with different exposure parameters","volume":"46","author":"Bohner","year":"2017","unstructured":"Bohner\n              LOL,\n            \n            \n              Tortamano\n              P,\n            \n            \n              Marotti\n              J.\n            \n          \n          Accuracy of linear measurements around dental implants by means of cone beam computed tomography with different exposure parameters. \nDentomaxillofac Radiol. \n2017;46:\n20160377."},{"key":"i1548-1336-50-2-111-b30","series-title":"Oral Surg Oral Med Oral Pathol Oral Radiol","first-page":"780","article-title":"Integration accuracy of laser-scanned dental models into maxillofacial cone beam computed tomography images of different voxel sizes with different segmentation threshold settings","volume":"117","author":"Ye","year":"2014","unstructured":"Ye\n              N,\n            \n            \n              Long\n              H,\n            \n            \n              Xue\n              J,\n            \n            \n              Wang\n              S,\n            \n            \n              Yang\n              X,\n            \n            \n              Lai\n              W.\n            \n          \n          Integration accuracy of laser-scanned dental models into maxillofacial cone beam computed tomography images of different voxel sizes with different segmentation threshold settings. \nOral Surg Oral Med Oral Pathol Oral Radiol. \n2014;117:\n780\u2013786."},{"key":"i1548-1336-50-2-111-b31","series-title":"Clin Oral Implants Res","first-page":"826","article-title":"Impact of number of registration points on the positional accuracy of a prosthetic treatment plan incorporated into a cone beam computed tomography scan by surface scan registration: an in vitro study","volume":"30","author":"Jamjoom","year":"2019","unstructured":"Jamjoom\n              FZ,\n            \n            \n              Yilmaz\n              B,\n            \n            \n              Johnston\n              WM.\n            \n          \n          Impact of number of registration points on the positional accuracy of a prosthetic treatment plan incorporated into a cone beam computed tomography scan by surface scan registration: an in vitro study. \nClin Oral Implants Res. \n2019;30:\n826\u2013832."},{"key":"i1548-1336-50-2-111-b32","series-title":"Clin Oral Implants Res","first-page":"1067","article-title":"Influence of surgical guide support and implant site location on accuracy of static computer-assisted implant surgery","volume":"30","author":"El Kholy","year":"2019","unstructured":"El Kholy\n              K,\n            \n            \n              Lazarin\n              R,\n            \n            \n              Janner\n              SFM,\n            \n            \n              Faerber\n              K,\n            \n            \n              Buser\n              R,\n            \n            \n              Buser\n              D.\n            \n          \n          Influence of surgical guide support and implant site location on accuracy of static computer-assisted implant surgery. \nClin Oral Implants Res. \n2019;30:\n1067\u20131075."},{"key":"i1548-1336-50-2-111-b33","series-title":"Oral Radiol","first-page":"32","article-title":"Impact of the number of registration points for replacement of three-dimensional computed tomography images in dental areas using three-dimensional light-scanned images of dental models","volume":"30","author":"Choi","year":"2014","unstructured":"Choi\n              Y-S,\n            \n            \n              Kim\n              M-K,\n            \n            \n              Lee\n              J-W,\n            \n            \n              Kang\n              S-H.\n            \n          \n          Impact of the number of registration points for replacement of three-dimensional computed tomography images in dental areas using three-dimensional light-scanned images of dental models. \nOral Radiol. \n2014;30:\n32\u201367."},{"key":"i1548-1336-50-2-111-b34","series-title":"J Clin Periodontol","first-page":"717","article-title":"A randomized clinical trial comparing guided implant surgery (bone- or mucosa-supported) with mental navigation or the use of a pilot-drill template","volume":"41","author":"Vercruyssen","year":"2014","unstructured":"Vercruyssen\n              M,\n            \n            \n              Cox\n              C,\n            \n            \n              Coucke\n              W,\n            \n            \n              Naert\n              I,\n            \n            \n              Jacobs\n              R,\n            \n            \n              Quirynen\n              M.\n            \n          \n          A randomized clinical trial comparing guided implant surgery (bone- or mucosa-supported) with mental navigation or the use of a pilot-drill template. \nJ Clin Periodontol. \n2014;41:\n717\u2013723."},{"key":"i1548-1336-50-2-111-b35","series-title":"Implant Dent","first-page":"500","article-title":"Freehand versus guided surgery: factors influencing accuracy of dental implant placement","volume":"26","author":"Choi","year":"2017","unstructured":"Choi\n              W,\n            \n            \n              Nguyen\n              BC,\n            \n            \n              Doan\n              A,\n            \n            \n              Girod\n              S,\n            \n            \n              Gaudilliere\n              B,\n            \n            \n              Gaudilliere\n              D.\n            \n          \n          Freehand versus guided surgery: factors influencing accuracy of dental implant placement. \nImplant Dent. \n2017;26:\n500\u2013509."},{"key":"i1548-1336-50-2-111-b36","series-title":"J Clin Periodontol","first-page":"949","article-title":"The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery","volume":"46","author":"Smitkarn","year":"2019","unstructured":"Smitkarn\n              P,\n            \n            \n              Subbalekha\n              K,\n            \n            \n              Mattheos\n              N,\n            \n            \n              Pimkhaokham\n              A.\n            \n          \n          The accuracy of single-tooth implants placed using fully digital-guided surgery and freehand implant surgery. \nJ Clin Periodontol. \n2019;46:\n949\u2013957."},{"key":"i1548-1336-50-2-111-b37","series-title":"Dentomaxillofac Radiol","first-page":"20140019","article-title":"Assessment of metal artefact reduction around dental titanium implants in cone beam CT","volume":"43","author":"Parsa","year":"2014","unstructured":"Parsa\n              A,\n            \n            \n              Ibrahim\n              N,\n            \n            \n              Hassan\n              B,\n            \n            \n              Syriopoulos\n              K,\n            \n            \n              van der Stelt\n              P.\n            \n          \n          Assessment of metal artefact reduction around dental titanium implants in cone beam CT. \nDentomaxillofac Radiol. \n2014;43:\n20140019."},{"key":"i1548-1336-50-2-111-b38","series-title":"Clin Implant Dent Relat Res","first-page":"300","article-title":"Effect of length and location of edentulous area on the accuracy of prosthetic treatment plan incorporation into cone-beam computed tomography scans","volume":"20","author":"Jamjoom","year":"2018","unstructured":"Jamjoom\n              FZ,\n            \n            \n              Kim\n              DG,\n            \n            \n              Lee\n              DJ,\n            \n            \n              McGlumphy\n              EA,\n            \n            \n              Yilmaz\n              B.\n            \n          \n          Effect of length and location of edentulous area on the accuracy of prosthetic treatment plan incorporation into cone-beam computed tomography scans. \nClin Implant Dent Relat Res. \n2018;20:\n300\u2013307."},{"key":"i1548-1336-50-2-111-b39","series-title":"Clin Oral Implants Res","first-page":"1147","article-title":"Deviations of different systems for guided implant surgery","volume":"28","author":"Laederach","year":"2017","unstructured":"Laederach\n              V,\n            \n            \n              Mukaddam\n              K,\n            \n            \n              Payer\n              M,\n            \n            \n              Filippi\n              A,\n            \n            \n              Kuhl\n              S.\n            \n          \n          Deviations of different systems for guided implant surgery. \nClin Oral Implants Res. \n2017;28:\n1147\u20131151."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/50\/2\/article-p111.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/joi\/article-pdf\/doi\/10.1563\/aaid-joi-D-23-00076\/3333880\/aaid-joi-d-23-00076.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/50\/2\/article-p111.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/50\/2\/article-p111.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,11]],"date-time":"2025-07-11T00:20:26Z","timestamp":1752193226000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/50\/2\/article-p111.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4]]},"references-count":39,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-23-00076","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"type":"electronic","value":"1548-1336"},{"type":"print","value":"0160-6972"}],"subject":[],"published":{"date-parts":[[2024,4]]}}}