{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,8]],"date-time":"2026-01-08T07:32:06Z","timestamp":1767857526780,"version":"3.49.0"},"reference-count":25,"publisher":"American Academy of Implant Dentistry","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,4]]},"abstract":"<jats:p>Natural teeth have a periodontal ligament with viscoelastic properties, while implants are connected to the bone with a strong connection and osseointegration; therefore, the stress on the adjacent bone of the implant and its prosthetic components is more than that of natural teeth. This study examines the connection (Morse different tapers) to find the most suitable length and Morse angle of the taper and the angle of applying the force on the tooth to create the least stress using finite element analysis. Geometrical and 3D models of the mandible bone, implant, and its prosthetic components were made using engineering software and sizes of the DIO implant manufacturer. In this modeling, 4 types of connections with different lengths and tipping angles were designed, and then a constant force of 200 N was applied to them. Stress distribution was investigated in this experiment in 12 different conditions: 2 Morse taper lengths (1.3 mm and 2.6 mm), 2 Morse taper angles (11\u00b0 and 16\u00b0), and 3 force application angles (0\u00b0, 30\u00b0, and 45\u00b0). By increasing the length of the Morse taper from 1.3 mm to 2.6 mm, the amount of stress in the bone adjacent to the implant and its prosthetic components is reduced. By increasing the tipping angle of the Morse taper from 11\u00b0 to 16\u00b0, the amount of stress in the bone adjacent to the implant, the fixture, and the abutment decreases. Furthermore, by increasing the tipping angle of the morse from 11\u00b0 to 16\u00b0 the amount of stress in the implant screw increases. Increasing the angle of the force applied to the implant increases the amount of stress in the bone adjacent to the implant and its prosthetic components. The best Morse taper connection to create the least stress on the bone surrounding the implant and its prosthetic components is a long taper Morse with a length of 2.6 mm and a greater tipping angle (16\u00b0), This stress is less at the vertical force application angle.<\/jats:p>","DOI":"10.1563\/aaid-joi-d-24-00187","type":"journal-article","created":{"date-parts":[[2025,2,5]],"date-time":"2025-02-05T04:26:42Z","timestamp":1738729602000},"page":"134-141","source":"Crossref","is-referenced-by-count":1,"title":["Stress Distribution Analysis in Bone Adjacent to Implant in Various Abutment-Implant Connection Designs Using Finite Element Analysis"],"prefix":"10.1563","volume":"51","author":[{"given":"Ehsan","family":"Ghasemi","sequence":"first","affiliation":[{"name":"Dental Implants Research Center, Department of Prosthodontics, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amirhossein","family":"Fathi","sequence":"additional","affiliation":[{"name":"Dental Prosthodontics Department, Dental Materials Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daryoush","family":"Mohammadi","sequence":"additional","affiliation":[{"name":"Dental Student\u2019s Research Committee, School of Dentistry, Isfahan University of Medical Sciences, Isfahan, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sepideh","family":"Salehi","sequence":"additional","affiliation":[{"name":"Isfahan University of Medical Sciences, School of Dentistry, Isfahan, Iran"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"434","reference":[{"key":"i1548-1336-51-2-134-b01","series-title":"Dent Res J (Isfahan)","first-page":"741","article-title":"Evaluation of stress distribution of implant-retained mandibular overdenture with different vertical restorative spaces: a finite element analysis","volume":"9","author":"Ebadian","year":"2012","unstructured":"Ebadian\n              B\n            ,\nFarzinM,\nTalebiS,\nKhodaeianN.\n          Evaluation of stress distribution of implant-retained mandibular overdenture with different vertical restorative spaces: a finite element analysis. Dent Res J (Isfahan). 2012;9:741\u2013747."},{"key":"i1548-1336-51-2-134-b02","series-title":"Indian J Dent Res","first-page":"634","article-title":"A three-dimensional finite element analysis to evaluate stress distribution tooth in tooth implant-supported prosthesis with variations in non-rigid connector design and location","volume":"29","author":"Nitin","year":"2018","unstructured":"Nitin\n              KS\n            ,\nPadmanabhanTV,\nKumarVA,\nParthasarathiN,\nUma MaheswariM,\nKumarSM.\n          A three-dimensional finite element analysis to evaluate stress distribution tooth in tooth implant-supported prosthesis with variations in non-rigid connector design and location. Indian J Dent Res. 2018;29:634\u2013640."},{"key":"i1548-1336-51-2-134-b03","series-title":"Dental Hypotheses","first-page":"109","article-title":"Stress analysis of different prosthesis materials in implant-supported fixed dental prosthesis using 3D finite element method","volume":"5","author":"Iranmanesh","year":"2014","unstructured":"Iranmanesh\n              P\n            ,\nAbedianA,\nNasriN,\nGhasemiE,\nKhazaeiS.\n          Stress analysis of different prosthesis materials in implant-supported fixed dental prosthesis using 3D finite element method. Dental Hypotheses. 2014;5:109\u2013114."},{"key":"i1548-1336-51-2-134-b04","series-title":"J Biomech","first-page":"87","article-title":"Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants","volume":"38","author":"Bozkaya","year":"2005","unstructured":"Bozkaya\n              D\n            ,\nM\u00fcft\u00fcS.\n          Mechanics of the taper integrated screwed-in (TIS) abutments used in dental implants. J Biomech. 2005;38:87\u201397."},{"key":"i1548-1336-51-2-134-b05","series-title":"Principles for abutment and prosthetic screws and screw-retained components and prostheses. Contemporary Implant Dentistry","first-page":"724","author":"Misch","year":"2015","unstructured":"Misch\n              C.\n            \n          \n          \n            Principles for abutment and prosthetic screws and screw-retained components and prostheses. Contemporary Implant Dentistry\n          . St. Louis, MO: Mosby; 2015;724 \u2013752."},{"key":"i1548-1336-51-2-134-b06","series-title":"J Biomech","first-page":"1649","article-title":"Mechanics of the tapered interference fit in dental implants","volume":"36","author":"Bozkaya","year":"2003","unstructured":"Bozkaya\n              D\n            ,\nM\u00fcft\u00fcS.\n          Mechanics of the tapered interference fit in dental implants. J Biomech. 2003;36:1649\u20131658."},{"key":"i1548-1336-51-2-134-b07","series-title":"J Prosthet Dent","first-page":"267","article-title":"Ten-year evaluation of removable partial dentures: survival rates based on retreatment, not wearing and replacement","volume":"76","author":"Vermeulen","year":"1996","unstructured":"Vermeulen\n              AH\n            ,\nKeltjensHM,\nvan\u2019t HofMA,\nKayserAF.\n          Ten-year evaluation of removable partial dentures: survival rates based on retreatment, not wearing and replacement. J Prosthet Dent. 1996;76:267\u2013272."},{"key":"i1548-1336-51-2-134-b08","series-title":"Clin Oral Investig","first-page":"74","article-title":"Clinical evaluation of removable partial dentures 10 years after insertion: success rates, hygienic problems, and technical failures","volume":"4","author":"Wagner","year":"2000","unstructured":"Wagner\n              B\n            ,\nKernM.\n          Clinical evaluation of removable partial dentures 10 years after insertion: success rates, hygienic problems, and technical failures. Clin Oral Investig. 2000;4:74\u201380."},{"key":"i1548-1336-51-2-134-b09","series-title":"Int J Periodontics Restorative Dent","first-page":"e49","article-title":"Three-dimensional finite element analysis of the stress distribution at the internal implant-abutment connection","volume":"36","author":"Cho","year":"2016","unstructured":"Cho\n              SY\n            ,\nHuhYH,\nParkCJ,\nChoLR.\n          Three-dimensional finite element analysis of the stress distribution at the internal implant-abutment connection. Int J Periodontics Restorative Dent. 2016;36:e49\u2013e58."},{"key":"i1548-1336-51-2-134-b10","series-title":"J Oral Implantol","first-page":"155","article-title":"Stress distribution around osseointegrated implants with different internal-cone connections: photoelastic and finite element analysis","volume":"41","author":"Anami","year":"2015","unstructured":"Anami\n              LC\n            ,\nda Costa LimaJM,\nTakahashiFE,\nNeisserMP,\nNoritomiPY,\nBottinoMA.\n          Stress distribution around osseointegrated implants with different internal-cone connections: photoelastic and finite element analysis. J Oral Implantol. 2015;41:155\u2013162."},{"key":"i1548-1336-51-2-134-b11","series-title":"Int J Environ Res Public Health","first-page":"4738","article-title":"Effect of different implant designs on strain and stress distribution under non-axial loading: a three-dimensional finite element analysis","volume":"17","author":"Oliveira","year":"2020","unstructured":"Oliveira\n              H\n            ,\nBrizuela VelascoA,\nR\u00edos-SantosJV, et al.\n          Effect of different implant designs on strain and stress distribution under non-axial loading: a three-dimensional finite element analysis. Int J Environ Res Public Health. 2020;17:4738."},{"key":"i1548-1336-51-2-134-b12","series-title":"Materials (Basel)","first-page":"5866","article-title":"Effects of marginal bone loss progression on stress distribution in different implant-abutment connections and abutment materials: a 3d finite element analysis study","volume":"15","author":"Lin","year":"2022","unstructured":"Lin\n              CP\n            ,\nShyuYT,\nWuYL,\nTsaiMH,\nChenHS,\nWuAY.\n          Effects of marginal bone loss progression on stress distribution in different implant-abutment connections and abutment materials: a 3d finite element analysis study. Materials (Basel). 2022;15:5866."},{"key":"i1548-1336-51-2-134-b13","series-title":"J Prosthodont","first-page":"107","article-title":"An investigation of tooth\/implant-supported fixed prosthesis designs with two different stress analysis methods: an in vitro study","volume":"16","author":"Oz\u00e7elik","year":"2007","unstructured":"Oz\u00e7elik\n              T\n            ,\nErsoyAE.\n          An investigation of tooth\/implant-supported fixed prosthesis designs with two different stress analysis methods: an in vitro study. J Prosthodont. 2007;16:107\u2013116."},{"key":"i1548-1336-51-2-134-b14","series-title":"J Prosthet Dent","first-page":"20","article-title":"Influence of implant length and diameter on stress distribution: a finite element analysis","volume":"91","author":"Himmlov\u00e1","year":"2004","unstructured":"Himmlov\u00e1\n              L\n            ,\nDost\u00e1lov\u00e1T,\nK\u00e1covsk\u00fdA,\nKonvickov\u00e1S.\n          Influence of implant length and diameter on stress distribution: a finite element analysis. J Prosthet Dent. 2004;91:20\u201325."},{"key":"i1548-1336-51-2-134-b15","series-title":"J Prosthet Dent","first-page":"422","article-title":"The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis","volume":"100","author":"Baggi","year":"2008","unstructured":"Baggi\n              L\n            ,\nCappelloniI,\nDi GirolamoM,\nMaceriF,\nVairoG.\n          The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis. J Prosthet Dent. 2008;100:422\u2013431."},{"key":"i1548-1336-51-2-134-b16","series-title":"World J Med Sci","first-page":"217","article-title":"Influence of different angulations of force in stress distribution in implant retained finger prosthesis: a finite element study","volume":"10","author":"Amornvit","year":"2014","unstructured":"Amornvit\n              P\n            ,\nRokayaD,\nKeawcharoenK,\nThongpulsawasdiN.\n          Influence of different angulations of force in stress distribution in implant retained finger prosthesis: a finite element study. World J Med Sci. 2014;10:217\u2013221."},{"key":"i1548-1336-51-2-134-b17","series-title":"Odontology","first-page":"31","article-title":"Finite element analysis of the influence of implant inclination, loading position, and load direction on stress distribution","volume":"91","author":"Watanabe","year":"2003","unstructured":"Watanabe\n              F\n            ,\nHataY,\nKomatsuS,\nRamosTC,\nFukudaH.\n          Finite element analysis of the influence of implant inclination, loading position, and load direction on stress distribution. Odontology. 2003;91:31\u201336."},{"key":"i1548-1336-51-2-134-b18","series-title":"J Oral Implantol","first-page":"37","article-title":"Stress distribution around maxillary anterior implants as a factor of labial bone thickness and occlusal load angles: a 3-dimensional finite element analysis","volume":"40","author":"Alikhasi","year":"2014","unstructured":"Alikhasi\n              M\n            ,\nSiadatH,\nGeramyA,\nHassan-AhangariA.\n          Stress distribution around maxillary anterior implants as a factor of labial bone thickness and occlusal load angles: a 3-dimensional finite element analysis. J Oral Implantol. 2014;40:37\u201341."},{"key":"i1548-1336-51-2-134-b19","series-title":"Eur J Dent","first-page":"311","article-title":"The effect of implant angulation and splinting on stress distribution in implant body and supporting bone: a finite element analysis","volume":"9","author":"Ebadian","year":"2015","unstructured":"Ebadian\n              B\n            ,\nMosharrafR,\nAbbasiS,\nPouyaM,\nMahmoodF.\n          The effect of implant angulation and splinting on stress distribution in implant body and supporting bone: a finite element analysis. Eur J Dent. 2015;9:311\u2013318."},{"key":"i1548-1336-51-2-134-b20","series-title":"J Prosthodont","first-page":"95","article-title":"A three-dimensional finite element stress analysis of angled abutments for an implant placed in the anterior maxilla","volume":"4","author":"Clelland","year":"1995","unstructured":"Clelland\n              NL\n            ,\nLeeJK,\nBimbenetOC,\nBrantleyWA.\n          A three-dimensional finite element stress analysis of angled abutments for an implant placed in the anterior maxilla. J Prosthodont. 1995;4:95\u2013100."},{"key":"i1548-1336-51-2-134-b21","series-title":"Quintessence Int","first-page":"591","article-title":"Comparison of stress distribution around vertical and angled implants with finite-element analysis","volume":"27","author":"Canay","year":"1996","unstructured":"Canay\n              S\n            ,\nHersekN,\nAkpinarI,\nA\u015fikZ.\n          Comparison of stress distribution around vertical and angled implants with finite-element analysis. Quintessence Int. 1996;27:591\u2013598."},{"key":"i1548-1336-51-2-134-b22","series-title":"J Prosthet Dent","first-page":"624","article-title":"Effects of overdenture retention designs and implant orientations on load transfer characteristics","volume":"76","author":"Federick","year":"1996","unstructured":"Federick\n              DR\n            ,\nCaputoAA.\n          Effects of overdenture retention designs and implant orientations on load transfer characteristics. J Prosthet Dent. 1996;76:624\u2013632."},{"key":"i1548-1336-51-2-134-b23","series-title":"Int J Oral Maxillofac Implants","first-page":"511","article-title":"Comparison of tilted versus nontilted implant-supported prosthetic designs for the restoration of the edentuous mandible: a biomechanical study","volume":"24","author":"Bellini","year":"2009","unstructured":"Bellini\n              CM\n            ,\nRomeoD,\nGalbuseraF, et al.\n          Comparison of tilted versus nontilted implant-supported prosthetic designs for the restoration of the edentuous mandible: a biomechanical study. Int J Oral Maxillofac Implants. 2009;24:511\u2013517."},{"key":"i1548-1336-51-2-134-b24","series-title":"Dent J","first-page":"261","article-title":"Biomechanical effects of different load cases with an implant-supported full bridge on four implants in an edentulous mandible: a three-dimensional finite element analysis (3D-FEA)","volume":"11","author":"Szab\u00f3","year":"2023","unstructured":"Szab\u00f3\n              \u00c1L\n            ,\nMatusovitsD,\nSlyteenH,\nLakatos\u00c9I,\nBar\u00e1thZ.\n          Biomechanical effects of different load cases with an implant-supported full bridge on four implants in an edentulous mandible: a three-dimensional finite element analysis (3D-FEA). Dent J. 2023;11:261."},{"key":"i1548-1336-51-2-134-b25","series-title":"Int J Implant Dent","first-page":"17","article-title":"Biomechanical effects of offset placement of dental implants in the edentulous posterior mandible","volume":"2","author":"Shimura","year":"2016","unstructured":"Shimura\n              Y\n            ,\nSatoY,\nKitagawaN,\nOmoriM.\n          Biomechanical effects of offset placement of dental implants in the edentulous posterior mandible. Int J Implant Dent. 2016;2:17."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/51\/2\/article-p134.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/joi\/article-pdf\/51\/2\/134\/3513138\/i1548-1336-51-2-134.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/51\/2\/article-p134.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/51\/2\/article-p134.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,11]],"date-time":"2025-09-11T00:31:14Z","timestamp":1757550674000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/51\/2\/article-p134.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":25,"journal-issue":{"issue":"2"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-24-00187","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"value":"1548-1336","type":"electronic"},{"value":"0160-6972","type":"print"}],"subject":[],"published":{"date-parts":[[2025,4]]}}}