{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T01:13:08Z","timestamp":1783732388257,"version":"3.55.0"},"reference-count":63,"publisher":"American Academy of Implant Dentistry","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,2]]},"abstract":"<jats:p>This study aimed to compare the retention of cobalt-chromium and polyetheretherketone secondary telescopic crowns in implant-retained mandibular overdentures. Twelve patients were selected for the study, each received 2 implants in the canine region bilaterally to retain a mandibular overdenture with milled telescopic crowns. The primary crowns with 2\u00b0 occlusal taper were fabricated using milled titanium abutments. Later, the patients were randomly divided into 2 groups: the cobalt-chromium group, where the secondary crowns were fabricated from milled cobalt-chromium alloy, and the polyetheretherketone group, where secondary crowns were constructed from milled polyetheretherketone. Retention was evaluated at the relative geometric center at baseline (zero months), 6, 9, and 12 months postprosthetic loading using a force meter gauge. The mean of 5 retention force readings was recorded in Newtons for each patient at follow-up visits, and the data were subject to statistical analysis. At baseline, after 6, 9, and 12 months, the CoCr group showed statistically significantly lower mean retention value than the PEEK group. A statistically significant decrease in retention forces within both groups was observed after 12 months postprosthetic loading. The present study suggested that milled cobalt-chromium and polyetheretherketone secondary telescopic crowns in combination with titanium primary conical crowns may provide an acceptable treatment option for completely edentulous patients regarding retentive force. The milled polyetheretherketone secondary telescopic crowns may offer higher retentive force compared to milled cobalt-chromium ones in clinical performance. To prefer one of these materials over the other needs more extensive research.<\/jats:p>","DOI":"10.1563\/aaid-joi-d-24-00230","type":"journal-article","created":{"date-parts":[[2025,8,22]],"date-time":"2025-08-22T00:31:30Z","timestamp":1755822690000},"page":"53-68","source":"Crossref","is-referenced-by-count":0,"title":["Retention Comparison of Milled Cobalt Chromium and Polyetheretherketone Secondary Telescopic Crowns in Implant-Retained Mandibular Overdentures: A Randomized Clinical Trial"],"prefix":"10.1563","volume":"52","author":[{"given":"Doaa","family":"Tawfik","sequence":"first","affiliation":[{"name":"Faculty of Dentistry, Minia University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amr","family":"Khalifa","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Alamein International University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Iman A.","family":"El Asfahani","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Minia University"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emad","family":"Agamy","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Minia University"},{"name":"Delta University for Science and Technology"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"434","reference":[{"key":"i1548-1336-52-1-53-b01","series-title":"Clin Exp Dent Res","first-page":"231","article-title":"Evaluation of the quality of life and satisfaction in patients using complete dentures versus mandibular overdentures. Systematic review and meta-analysis","volume":"7","author":"Egido Moreno","year":"2021","unstructured":"Egido Moreno S,\nAyuso Montero R,\nSchemel Su\u00e1rez M,\nRoca-Umbert JV,\nIzquierdo G\u00f3mez K,\nL\u00f3pez L\u00f3pez J. Evaluation of the quality of life and satisfaction in patients using complete dentures versus mandibular overdentures. Systematic review and meta-analysis. Clin Exp Dent Res. 2021;7:231\u2013241."},{"key":"i1548-1336-52-1-53-b02","series-title":"Int J Environ Res Public Health","first-page":"557","article-title":"Patients\u2019 satisfaction and oral health-related quality of life of edentulous patients using conventional complete dentures and implant-retained overdentures in Saudi Arabia","volume":"19","author":"Bajunaid","year":"2022","unstructured":"Bajunaid SO,\nAlshahrani AS,\nAldosari AA, et al. Patients\u2019 satisfaction and oral health-related quality of life of edentulous patients using conventional complete dentures and implant-retained overdentures in Saudi Arabia. Int J Environ Res Public Health. 2022;19:557."},{"key":"i1548-1336-52-1-53-b03","series-title":"J Indian Prosthodont Soc","first-page":"319","article-title":"Mandibular implant-supported overdenture: a systematic review and meta-analysis for optimum selection of attachment system","volume":"21","author":"Sutariya","year":"2021","unstructured":"Sutariya PV,\nShah HM,\nPatel SD,\nUpadhyay HH,\nPathan MR,\nShah RP. Mandibular implant-supported overdenture: a systematic review and meta-analysis for optimum selection of attachment system. J Indian Prosthodont Soc. 2021;21:319\u2013327."},{"key":"i1548-1336-52-1-53-b04","series-title":"Principles of attachment selection","first-page":"31","article-title":"Clinical and Laboratory Manual of Implant Overdentures","author":"Shafie","year":"2007","unstructured":"Shafie H. Principles of attachment selection. Clinical and Laboratory Manual of Implant Overdentures. 1st ed. Ames, IA: Blackwell Munksgaard; 2007:31\u201336. https:\/\/www.blackwellpublishing.com\/content\/bpl_images\/content_store\/sample_chapter\/9780813808819\/9780813808819.pdf."},{"key":"i1548-1336-52-1-53-b05","series-title":"Med Princ Pract","first-page":"61","article-title":"Double crown-retained removable prostheses supported by implants or teeth and implants: a long-term clinical retrospective evaluation","volume":"32","author":"Zafiropoulos","year":"2023","unstructured":"Zafiropoulos GG,\nAbuzayeda M,\nMurray CA,\nBaig MR. Double crown-retained removable prostheses supported by implants or teeth and implants: a long-term clinical retrospective evaluation. Med Princ Pract. 2023;32:61\u201370."},{"key":"i1548-1336-52-1-53-b06","series-title":"Int J Dent Res","first-page":"17","article-title":"Telescopic double crowns in prosthodontics","volume":"8","author":"Kara","year":"2021","unstructured":"Kara R. Telescopic double crowns in prosthodontics. Int J Dent Res. 2021;8:17."},{"key":"i1548-1336-52-1-53-b07","series-title":"Int J Oral Maxillofac Implants","first-page":"598","article-title":"Comparison of ball and telescopic crown attachments in implant-retained mandibular overdentures: a 5-year prospective study","volume":"26","author":"Krennmair","year":"2011","unstructured":"Krennmair G,\nSeemann R,\nWeinl\u00e4nder M,\nPiehslinger E. Comparison of ball and telescopic crown attachments in implant-retained mandibular overdentures: a 5-year prospective study. Int J Oral Maxillofac Implants. 2011;26:598\u2013606."},{"key":"i1548-1336-52-1-53-b08","series-title":"Clin Oral Implants Res","first-page":"640","article-title":"Overdenture attachment selection and the loading of implant and denture-bearing area. Part 2: a methodical study using five types of attachment","volume":"12","author":"Heckmann","year":"2001","unstructured":"Heckmann SM,\nWinter W,\nMeyer M,\nWeber HP,\nWichmann MG. Overdenture attachment selection and the loading of implant and denture-bearing area. Part 2: a methodical study using five types of attachment. Clin Oral Implants Res. 2001;12:640\u2013647."},{"key":"i1548-1336-52-1-53-b09","series-title":"Materials (Basel)","first-page":"3228","article-title":"Retention force of removable partial dentures with CAD-CAM-fabricated telescopic crowns","volume":"13","author":"Arnold","year":"2020","unstructured":"Arnold C,\nSchweyen R,\nBoeckler A,\nHey J. Retention force of removable partial dentures with CAD-CAM-fabricated telescopic crowns. Materials (Basel). 2020;13:3228."},{"key":"i1548-1336-52-1-53-b10","series-title":"UPB Sci Bull","first-page":"169","article-title":"Evaluation of the force retention within the telescopic crowns with different taper angles by finite element analysis","volume":"84","author":"Fischer","year":"2022","unstructured":"Fischer CA,\nBaciu F,\nMaria D,\nComaneanu D. Evaluation of the force retention within the telescopic crowns with different taper angles by finite element analysis. UPB Sci Bull. 2022;84:169\u2013178."},{"key":"i1548-1336-52-1-53-b11","series-title":"J Oral Rehabil","first-page":"271","article-title":"Parameters affecting retentive force of conus crowns","volume":"31","author":"G\u00fcng\u00f6r","year":"2004","unstructured":"G\u00fcng\u00f6r MA,\nArtun\u00e7 C,\nSonugelen M. Parameters affecting retentive force of conus crowns. J Oral Rehabil. 2004;31:271\u2013277."},{"key":"i1548-1336-52-1-53-b12","series-title":"J Prosthodont","first-page":"162","article-title":"Retention load of telescopic crowns with different taper angles between cobalt-chromium and polyetheretherketone made with three different manufacturing processes examined by pull-off test","volume":"27","author":"Wagner","year":"2018","unstructured":"Wagner C,\nStock V,\nMerk S, et al. Retention load of telescopic crowns with different taper angles between cobalt-chromium and polyetheretherketone made with three different manufacturing processes examined by pull-off test. J Prosthodont. 2018;27:162\u2013168."},{"key":"i1548-1336-52-1-53-b13","series-title":"Clin Oral Investig","first-page":"129","article-title":"Parameters affecting retentive force of electroformed double-crown systems","volume":"14","author":"Beuer","year":"2010","unstructured":"Beuer F,\nEdelhoff D,\nGernet W,\nNaumann M. Parameters affecting retentive force of electroformed double-crown systems. Clin Oral Investig. 2010;14:129\u2013135."},{"key":"i1548-1336-52-1-53-b14","series-title":"J Adv Prosthodont","first-page":"308","article-title":"Comparison of retention forces with various fabrication methods and materials in double crowns","volume":"9","author":"\u00c7elik G\u00fcven","year":"2017","unstructured":"\u00c7elik G\u00fcven M,\nTuna M,\nBozda\u011f E,\n\u00d6zt\u00fcrk GN,\nBayraktar G. Comparison of retention forces with various fabrication methods and materials in double crowns. J Adv Prosthodont. 2017;9:308\u2013314."},{"key":"i1548-1336-52-1-53-b15","series-title":"Dent Mater J","first-page":"671","article-title":"Influence of the number of insertions and removals of telescopic zirconia\/alumina crowns on retentive force and settling","volume":"38","author":"Yoshikawa","year":"2019","unstructured":"Yoshikawa Y,\nTorii K,\nTanaka M. Influence of the number of insertions and removals of telescopic zirconia\/alumina crowns on retentive force and settling. Dent Mater J. 2019;38:671\u2013677."},{"key":"i1548-1336-52-1-53-b16","series-title":"Dent Mater J","first-page":"594","article-title":"Retention force of differently fabricated telescopic PEEK crowns with different tapers","volume":"35","author":"Stock","year":"2016","unstructured":"Stock V,\nWagner C,\nMerk S, et al. Retention force of differently fabricated telescopic PEEK crowns with different tapers. Dent Mater J. 2016;35:594\u2013600."},{"key":"i1548-1336-52-1-53-b17","series-title":"Metals","first-page":"149","article-title":"In vitro analysis of the tribological behaviour of different material combinations for telescopic crowns","volume":"6","author":"Linek","year":"2016","unstructured":"Linek W,\nRichter G,\nRaedel M,\nWalter M,\nReitemeier B. In vitro analysis of the tribological behaviour of different material combinations for telescopic crowns. Metals. 2016;6:149."},{"key":"i1548-1336-52-1-53-b18","series-title":"J Biomed Mater Res B Appl Biomater","first-page":"e35431","article-title":"A review on manufacturing processes of cobalt-chromium alloy implants and its impact on corrosion resistance and biocompatibility","volume":"112","author":"Mani","year":"2024","unstructured":"Mani G,\nPorter D,\nCollins S,\nSchatz T,\nOrnberg A,\nShulfer R. A review on manufacturing processes of cobalt-chromium alloy implants and its impact on corrosion resistance and biocompatibility. J Biomed Mater Res B Appl Biomater. 2024;112:e35431."},{"key":"i1548-1336-52-1-53-b19","series-title":"J Prosthet Dent","first-page":"156.e1\u2013156","article-title":"Mechanical properties of cobalt-chromium 3-unit fixed dental prostheses fabricated by casting, milling, and additive manufacturing","volume":"120","author":"\u00d8ilo","year":"2018","unstructured":"\u00d8ilo M,\nNesse H,\nLundberg OJ,\nGjerdet NR. Mechanical properties of cobalt-chromium 3-unit fixed dental prostheses fabricated by casting, milling, and additive manufacturing. J Prosthet Dent. 2018;120:156.e1\u2013156.e7."},{"key":"i1548-1336-52-1-53-b20","series-title":"Dent Mater","first-page":"e79","article-title":"Metallurgical and interfacial characterization of PFM Co-Cr dental alloys fabricated via casting, milling, or selective laser melting","volume":"30","author":"Al Jabbari","year":"2014","unstructured":"Al Jabbari YS,\nKoutsoukis T,\nBarmpagadaki X,\nZinelis S. Metallurgical and interfacial characterization of PFM Co-Cr dental alloys fabricated via casting, milling, or selective laser melting. Dent Mater. 2014;30:e79\u2013e88."},{"key":"i1548-1336-52-1-53-b21","series-title":"Mater","first-page":"908","article-title":"Suitability of secondary PEEK telescopic crowns on zirconia primary crowns: the influence of fabrication method and taper","volume":"9","author":"Merk","year":"2016","unstructured":"Merk S,\nWagner C,\nStock V, et al. Suitability of secondary PEEK telescopic crowns on zirconia primary crowns: the influence of fabrication method and taper. Mater. 2016;9:908."},{"key":"i1548-1336-52-1-53-b22","series-title":"Materials (Basel)","first-page":"596","article-title":"Microstructures and mechanical properties of Co-Cr dental alloys fabricated by three CAD\/CAM-based processing techniques","volume":"9","author":"Kim","year":"2016","unstructured":"Kim HR,\nJang SH,\nKim YK, et al. Microstructures and mechanical properties of Co-Cr dental alloys fabricated by three CAD\/CAM-based processing techniques. Materials (Basel). 2016;9:596."},{"key":"i1548-1336-52-1-53-b23","series-title":"J Prosthodont","first-page":"580","article-title":"The use of a modified poly-ether-ether-ketone (PEEK) as an alternative framework material for removable dental prostheses. A clinical report","volume":"25","author":"Zoidis","year":"2016","unstructured":"Zoidis P,\nPapathanasiou I,\nPolyzois G. The use of a modified poly-ether-ether-ketone (PEEK) as an alternative framework material for removable dental prostheses. A clinical report. J Prosthodont. 2016;25:580\u2013584."},{"key":"i1548-1336-52-1-53-b24","series-title":"J Prosthet Dent","first-page":"579","article-title":"Clinical performance of polymer frameworks in dental prostheses: a systematic review","volume":"131","author":"Gama","year":"2024","unstructured":"Gama LT,\nBezerra AP,\nSchimmel M,\nRodrigues Garcia RCM,\nde Luca Canto G,\nGon\u00e7alves TMSV. Clinical performance of polymer frameworks in dental prostheses: a systematic review. J Prosthet Dent. 2024;131:579\u2013590."},{"key":"i1548-1336-52-1-53-b25","series-title":"Dent Mater","first-page":"427","article-title":"In-vitro fatigue and fracture testing of CAD\/CAM-materials in implant-supported molar crowns","volume":"33","author":"Preis","year":"2017","unstructured":"Preis V,\nHahnel S,\nBehr M,\nBein L,\nRosentritt M. In-vitro fatigue and fracture testing of CAD\/CAM-materials in implant-supported molar crowns. Dent Mater. 2017;33:427\u2013433."},{"key":"i1548-1336-52-1-53-b26","series-title":"Eur J Prosthodont Restor Dent","first-page":"113","article-title":"PEEK High performance polymers: a review of properties and clinical applications in prosthodontics and restorative dentistry","volume":"27","author":"Alexakou","year":"2019","unstructured":"Alexakou E,\nDamanaki M,\nZoidis P, et al. PEEK High performance polymers: a review of properties and clinical applications in prosthodontics and restorative dentistry. Eur J Prosthodont Restor Dent. 2019;27:113\u2013121."},{"key":"i1548-1336-52-1-53-b27","series-title":"BMC Oral Health","first-page":"217","article-title":"The use of PEEK in digital prosthodontics: a narrative review","volume":"20","author":"Papathanasiou","year":"2020","unstructured":"Papathanasiou I,\nKamposiora P,\nPapavasiliou G,\nFerrari M. The use of PEEK in digital prosthodontics: a narrative review. BMC Oral Health. 2020;20:217."},{"key":"i1548-1336-52-1-53-b28","series-title":"J Prosthodont","first-page":"e595","article-title":"CAD\/CAM constructed poly(etheretherketone) (PEEK) framework of Kennedy Class I removable partial denture: a clinical report","volume":"28","author":"Harb","year":"2019","unstructured":"Harb IE,\nAbdel-Khalek EA,\nHegazy SA. CAD\/CAM constructed poly(etheretherketone) (PEEK) framework of Kennedy Class I removable partial denture: a clinical report. J Prosthodont. 2019;28:e595\u2013e598."},{"key":"i1548-1336-52-1-53-b29","series-title":"Int J Med Res Health Sci","first-page":"71","article-title":"Evaluation of the effect of different surface treatments on bond strength of heat cured acrylic resin at Co-Cr alloy and PEEK polymer interface","volume":"8","author":"Jassim","year":"2019","unstructured":"Jassim NA,\nJaber MA. Evaluation of the effect of different surface treatments on bond strength of heat cured acrylic resin at Co-Cr alloy and PEEK polymer interface. Int J Med Res Health Sci. 2019;8:71\u201383."},{"key":"i1548-1336-52-1-53-b30","series-title":"Cureus","first-page":"e46485","article-title":"Polyetheretherketone material in dentistry","volume":"15","author":"Parate","year":"2023","unstructured":"Parate KP,\nNaranje N,\nVishnani R,\nPaul P. Polyetheretherketone material in dentistry. Cureus. 2023;15:e46485."},{"key":"i1548-1336-52-1-53-b31","series-title":"Int Dent Res","first-page":"84","article-title":"Areas for use of PEEK material in dentistry","volume":"8","author":"Tekin","year":"2018","unstructured":"Tekin S,\nCang\u00fcl S,\nAd\u0131g\u00fczel \u00d6,\nDe\u011fer Y. Areas for use of PEEK material in dentistry. Int Dent Res. 2018;8:84\u201392."},{"key":"i1548-1336-52-1-53-b32","series-title":"J Prosthodont","first-page":"804","article-title":"Virtual evaluation of the accuracy of fit and trueness in maxillary poly(etheretherketone) removable partial denture frameworks fabricated by direct and indirect CAD\/CAM techniques","volume":"28","author":"Negm","year":"2019","unstructured":"Negm EE,\nAboutaleb FA,\nAlam-Eldein AM. Virtual evaluation of the accuracy of fit and trueness in maxillary poly(etheretherketone) removable partial denture frameworks fabricated by direct and indirect CAD\/CAM techniques. J Prosthodont. 2019;28:804\u2013810."},{"key":"i1548-1336-52-1-53-b33","series-title":"Eur J Dent","first-page":"115","article-title":"Mechanical response of PEKK and PEEK as frameworks for implant-supported full-arch fixed dental prosthesis: 3D finite element analysis","volume":"16","author":"Villefort","year":"2022","unstructured":"Villefort RF,\nDiamantino PJS,\nZeidler SLVV, et al. Mechanical response of PEKK and PEEK as frameworks for implant-supported full-arch fixed dental prosthesis: 3D finite element analysis. Eur J Dent. 2022;16:115\u2013121."},{"key":"i1548-1336-52-1-53-b34","series-title":"J Prosthet Dent","first-page":"315","article-title":"Interim rehabilitation of occlusal vertical dimension using a double-crown-retained removable dental prosthesis with polyetheretherketone framework","volume":"119","author":"Hahnel","year":"2018","unstructured":"Hahnel S,\nScherl C,\nRosentritt M. Interim rehabilitation of occlusal vertical dimension using a double-crown-retained removable dental prosthesis with polyetheretherketone framework. J Prosthet Dent. 2018;119:315\u2013318."},{"key":"i1548-1336-52-1-53-b35","series-title":"Curr Gerontol Geriatr Res","first-page":"3830267","article-title":"Impacts of denture retention and stability on oral health-related quality of life, general health, and happiness in elderly Thais","volume":"2019","author":"Limpuangthip","year":"2019","unstructured":"Limpuangthip N,\nSomkotra T,\nArksornnukit M. Impacts of denture retention and stability on oral health-related quality of life, general health, and happiness in elderly Thais. Curr Gerontol Geriatr Res. 2019;2019:3830267."},{"key":"i1548-1336-52-1-53-b36","series-title":"Int J Oral Maxillofac Implants","first-page":"397","article-title":"The influence of momentary retention forces on patient satisfaction and quality of life of two-implant\u2013retained mandibular overdenture wearers","volume":"30","author":"Geckili","year":"2015","unstructured":"Geckili O,\nCilingir A,\nErdogan O, et al. The influence of momentary retention forces on patient satisfaction and quality of life of two-implant\u2013retained mandibular overdenture wearers. Int J Oral Maxillofac Implants. 2015;30:397\u2013402."},{"key":"i1548-1336-52-1-53-b37","series-title":"J Indian Prosthodont Soc","first-page":"272","article-title":"Measuring the retention of removable mandibular prostheses by a standardized model: a technical report","volume":"19","author":"Thu","year":"2019","unstructured":"Thu KM,\nShimizu H,\nKanazawa M,\nMinakuchi S. Measuring the retention of removable mandibular prostheses by a standardized model: a technical report. J Indian Prosthodont Soc. 2019;19:272\u2013275."},{"key":"i1548-1336-52-1-53-b38","series-title":"Egypt Dent J","first-page":"1787","article-title":"Comparative assessment of retentive characteristics of nylon cap versus Retention.Sil in ball-retained mandibular implant overdentures. A randomized clinical trial","volume":"65","author":"Osman","year":"2019","unstructured":"Osman R,\nAbdel Aal M. Comparative assessment of retentive characteristics of nylon cap versus Retention.Sil in ball-retained mandibular implant overdentures. A randomized clinical trial. Egypt Dent J. 2019;65:1787\u20131794."},{"key":"i1548-1336-52-1-53-b39","series-title":"J Dent Heal Oral Disord Ther","first-page":"250","article-title":"Is the time an impact factor for improvement mandibular denture retention","volume":"9","author":"Elsawy","year":"2018","unstructured":"Elsawy AM,\nOmar NA,\nEl Asfahani IA. Is the time an impact factor for improvement mandibular denture retention? J Dent Heal Oral Disord Ther. 2018;9:250\u2013253."},{"key":"i1548-1336-52-1-53-b40","series-title":"Egypt Dent J","first-page":"3609","article-title":"Randomized controlled clinical trial of implant overdenture retained with zirconia bars or telescopic crowns: a 1-year follow-up","volume":"64","author":"Salloum","year":"2018","unstructured":"Salloum MG,\nHussien MO. Randomized controlled clinical trial of implant overdenture retained with zirconia bars or telescopic crowns: a 1-year follow-up. Egypt Dent J. 2018;64:3609\u20133621."},{"key":"i1548-1336-52-1-53-b41","series-title":"Clin Oral Invest","first-page":"2309","article-title":"Adaptation to new complete dentures\u2014is the neuromuscular system outcome-oriented or effort-oriented","volume":"22","author":"Eberhard","year":"2018","unstructured":"Eberhard L,\nOh K,\nEiffler C, et al. Adaptation to new complete dentures\u2014is the neuromuscular system outcome-oriented or effort-oriented. Clin Oral Invest. 2018;22:2309\u20132317."},{"key":"i1548-1336-52-1-53-b42","series-title":"Clin Implant Dent Relat Res","first-page":"692","article-title":"Short-term report of an ongoing prospective cohort study evaluating the outcome of full-arch implant-supported fixed hybrid polyetheretherketone acrylic resin prostheses and the All-on-Four concept","volume":"20","author":"Mal\u00f3","year":"2018","unstructured":"Mal\u00f3 P,\nde Ara\u00fajo Nobre M,\nMoura Guedes C, et al. Short-term report of an ongoing prospective cohort study evaluating the outcome of full-arch implant-supported fixed hybrid polyetheretherketone acrylic resin prostheses and the All-on-Four concept. Clin Implant Dent Relat Res. 2018;20:692\u2013702."},{"key":"i1548-1336-52-1-53-b43","series-title":"Treatment Options Before and After Edentulism: Tooth Supported Overdentures","first-page":"279","article-title":"Telescopic attachments used in tooth-supported overdentures","author":"Ozkan","year":"2023","unstructured":"Ozkan Y (Editor),\nHeker U. Telescopic attachments used in tooth-supported overdentures. In Treatment Options Before and After Edentulism: Tooth Supported Overdentures. Cham: Springer International Publishing; 2023:279\u2013348."},{"key":"i1548-1336-52-1-53-b44","series-title":"J Prosthet Dent","first-page":"547","article-title":"Evaluation of the clinical performance of dentures manufactured by computer-aided technology and conventional techniques: a systematic review","volume":"129","author":"Chappuis Chocano","year":"2023","unstructured":"Chappuis Chocano AP,\nVenante HS,\nBringel da Costa RM,\nPordeus MD,\nSantiago Junior JF,\nPorto VC. Evaluation of the clinical performance of dentures manufactured by computer-aided technology and conventional techniques: a systematic review. J Prosthet Dent. 2023;129:547\u2013553."},{"key":"i1548-1336-52-1-53-b45","series-title":"Rom J Med Dent Educ","article-title":"Advances in dental prosthetics: The role of CAD\/CAM technology in denture fabrication","volume":"13","author":"Bida","year":"2024","unstructured":"Bida C,\nVirvescu DI,\nBosinceanu DN, et al. Advances in dental prosthetics: The role of CAD\/CAM technology in denture fabrication. Rom J Med Dent Educ. 2024;13."},{"key":"i1548-1336-52-1-53-b46","series-title":"Clin Oral Investig","first-page":"4007","article-title":"Impact of material combinations and removal and insertion cycles on the retention force of telescopic systems","volume":"27","author":"Micovic Soldatovic","year":"2023","unstructured":"Micovic Soldatovic D,\nBitter M,\nMeinen J,\nHuth KC,\nLiebermann A,\nStawarczyk B. Impact of material combinations and removal and insertion cycles on the retention force of telescopic systems. Clin Oral Investig. 2023;27:4007\u20134016."},{"key":"i1548-1336-52-1-53-b47","series-title":"Clin Oral Investig","first-page":"129","article-title":"Parameters affecting retentive force of electroformed double-crown systems","volume":"14","author":"Beuer","year":"2010","unstructured":"Beuer F,\nEdelhoff D,\nGernet W,\nNaumann M. Parameters affecting retentive force of electroformed double-crown systems. Clin Oral Investig. 2010;14:129\u2013135."},{"key":"i1548-1336-52-1-53-b48","series-title":"Acta Bioeng Biomech","first-page":"35","article-title":"Retention force assessment in conical crowns in different material combinations","volume":"15","author":"Pietruski","year":"2013","unstructured":"Pietruski JK,\nSajewicz E,\nSudnik J,\nPietruska MD. Retention force assessment in conical crowns in different material combinations. Acta Bioeng Biomech. 2013;15:35\u201342."},{"key":"i1548-1336-52-1-53-b49","series-title":"J Mech Behav Biomed Mater","first-page":"104648","article-title":"Adhesion as a component of retention force of overdenture prostheses-study on selected Au based dental materials used for telescopic crowns using atomic force microscopy and contact angle techniques","volume":"121","author":"D\u0105browa","year":"2021","unstructured":"D\u0105browa T,\nWcis\u0142o A,\nMajstrzyk W, et al. Adhesion as a component of retention force of overdenture prostheses-study on selected Au based dental materials used for telescopic crowns using atomic force microscopy and contact angle techniques. J Mech Behav Biomed Mater. 2021;121:104648."},{"key":"i1548-1336-52-1-53-b50","series-title":"Dent Mater J","first-page":"635","article-title":"Effects of surface roughness and tapered angle of cone crown telescopic system on retentive force","volume":"30","author":"Sakai","year":"2011","unstructured":"Sakai Y,\nTakahashi H,\nIwasaki N,\nIgarashi Y. Effects of surface roughness and tapered angle of cone crown telescopic system on retentive force. Dent Mater J. 2011;30:635\u2013641."},{"key":"i1548-1336-52-1-53-b51","series-title":"J Prosthet Dent","first-page":"74","article-title":"The service life of implant-retained overdenture attachment systems","volume":"102","author":"Pigozzo","year":"2009","unstructured":"Pigozzo MN,\nMesquita MF,\nPessanha Henriques GE,\nVaz LG. The service life of implant-retained overdenture attachment systems. J Prosthet Dent. 2009;102:74\u201380."},{"key":"i1548-1336-52-1-53-b52","series-title":"Dent Med Probl","first-page":"167","article-title":"Reasons for the fatigue of ball attachments and their O-rings: a systematic review","volume":"60","author":"de Campos","year":"2023","unstructured":"de Campos MR,\nBotelho AL,\nDos Reis AC. Reasons for the fatigue of ball attachments and their O-rings: a systematic review. Dent Med Probl. 2023;60:167\u2013176."},{"key":"i1548-1336-52-1-53-b53","series-title":"J Dent Implant Res","first-page":"7","article-title":"Evaluation of the effects of oral rinses on the retention and surface topography of the ball attachment complex for implant overdentures","volume":"42","author":"Gopalakrishnan","year":"2023","unstructured":"Gopalakrishnan D,\nSivaprakasam AN,\nJeyapalan V,\nSampathkumar J,\nRamakrishnan H,\nMahadevan V. Evaluation of the effects of oral rinses on the retention and surface topography of the ball attachment complex for implant overdentures. J Dent Implant Res. 2023;42:7\u201317."},{"key":"i1548-1336-52-1-53-b54","series-title":"J Prosthet Dent","first-page":"323","article-title":"Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible: an in vitro study","volume":"80","author":"Setz","year":"1998","unstructured":"Setz J,\nLee SH,\nEngel E. Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible: an in vitro study. J Prosthet Dent. 1998;80:323\u2013329."},{"key":"i1548-1336-52-1-53-b55","series-title":"Implant Dent","first-page":"24","article-title":"Attachment systems for implant retained overdentures: a literature review","volume":"15","author":"Trakas","year":"2006","unstructured":"Trakas T,\nMichalakis K,\nKang K,\nHirayama H. Attachment systems for implant retained overdentures: a literature review. Implant Dent. 2006;15:24\u201334."},{"key":"i1548-1336-52-1-53-b56","series-title":"J Prosthodont","first-page":"63","article-title":"Evaluation of the retention force of double conical crowns used in combination with a galvanoforming and casting fabrication technique","volume":"22","author":"Gurbulak","year":"2013","unstructured":"Gurbulak AG,\nKilic K,\nEro\u011flu Z,\nGercekcioglu E,\nKesim B. Evaluation of the retention force of double conical crowns used in combination with a galvanoforming and casting fabrication technique. J Prosthodont. 2013;22:63\u201368."},{"key":"i1548-1336-52-1-53-b57","series-title":"Appl Sci","first-page":"3446","article-title":"Comparative stress analysis of polyetherketoneketone (PEKK) telescopic crowns supported by different primary crown materials","volume":"12","author":"Tribst","year":"2022","unstructured":"Tribst JP,\nDal Piva AM,\nSyed AU, et al. Comparative stress analysis of polyetherketoneketone (PEKK) telescopic crowns supported by different primary crown materials. Appl Sci. 2022;12:3446."},{"key":"i1548-1336-52-1-53-b58","series-title":"Polymers","first-page":"386","article-title":"PEEK for oral applications: Recent advances in mechanical and adhesive properties","volume":"15","author":"Luo","year":"2023","unstructured":"Luo C,\nLiu Y,\nPeng B, et al. PEEK for oral applications: Recent advances in mechanical and adhesive properties. Polymers. 2023;15:386."},{"key":"i1548-1336-52-1-53-b59","series-title":"Clin Oral Investig","first-page":"2331","article-title":"Retentive force of PEEK secondary crowns on zirconia primary crowns over time","volume":"23","author":"Schubert","year":"2019","unstructured":"Schubert O,\nReitmaier J,\nSchweiger J,\nErdelt K,\nG\u00fcth JF. Retentive force of PEEK secondary crowns on zirconia primary crowns over time. Clin Oral Investig. 2019;23:2331\u20132338."},{"key":"i1548-1336-52-1-53-b60","series-title":"Materials (Basel)","first-page":"187","article-title":"PEEK primary crowns with cobalt-chromium, zirconia and galvanic secondary crowns with different tapers-a comparison of retention forces","volume":"9","author":"Stock","year":"2016","unstructured":"Stock V,\nSchmidlin PR,\nMerk S, et al. PEEK primary crowns with cobalt-chromium, zirconia and galvanic secondary crowns with different tapers-a comparison of retention forces. Materials (Basel). 2016;9:187."},{"key":"i1548-1336-52-1-53-b61","series-title":"IOSR J Dent Med Sci","first-page":"59","article-title":"Surface wear of all zirconia, all PEEK and zirconia-peek telescopic attachments for two implants retained mandibular complete overdentures. Vitro study using scanning electron microscope","volume":"18","author":"Emera","year":"2019","unstructured":"Emera R,\nElgamal M,\nAlbadwei M. Surface wear of all zirconia, all PEEK and zirconia-peek telescopic attachments for two implants retained mandibular complete overdentures. Vitro study using scanning electron microscope. IOSR J Dent Med Sci. 2019;18:59\u201368."},{"key":"i1548-1336-52-1-53-b62","series-title":"Dent Clin North America","first-page":"215","article-title":"Complications associated with implant-retained removable prostheses","volume":"59","author":"Vahidi","year":"2015","unstructured":"Vahidi F,\nPinto-Sinai G. Complications associated with implant-retained removable prostheses. Dent Clin North America. 2015;59:215\u2013226."},{"key":"i1548-1336-52-1-53-b63","series-title":"Int J Oral Maxillofac Implants","first-page":"657","article-title":"Investigation of mucosa-induced residual ridge resorption under implant-retained overdentures and complete dentures in the mandible","volume":"30","author":"Ahmad","year":"2015","unstructured":"Ahmad R,\nChen J,\nAbu-Hassan MI,\nLi Q,\nSwain MV. Investigation of mucosa-induced residual ridge resorption under implant-retained overdentures and complete dentures in the mandible. Int J Oral Maxillofac Implants. 2015;30:657\u2013666."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/52\/1\/article-p53.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/52\/1\/article-p53.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/52\/1\/article-p53.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,11]],"date-time":"2026-07-11T00:31:17Z","timestamp":1783729877000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/52\/1\/article-p53.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2]]},"references-count":63,"journal-issue":{"issue":"1"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-24-00230","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"value":"1548-1336","type":"electronic"},{"value":"0160-6972","type":"print"}],"subject":[],"published":{"date-parts":[[2026,2]]}}}