{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T06:00:29Z","timestamp":1760162429718,"version":"3.44.0"},"reference-count":34,"publisher":"American Academy of Implant Dentistry","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,8]]},"abstract":"<jats:p>The dental implant is an effective long-term procedure for oral edentulism due to its efficacy to support functional masticatory loading forces. The implant prosthetic joint is considered a key factor for interface stability due to its biological and biomechanical implications. The present investigation aimed to evaluate the fracture strength of 2 different implant prosthetic joints. This investigation tested 10 implants for each group: a conometric implant joint (group I) and internal hexagon implant (group II). The implant abutment joint was coupled using a calibrated torquemeter. The samples were assessed using a loading fracture test and radiographically evaluated to observe the interface changes and deformations. The means and standard deviations of the group I and group II maximum force (N) were 553 \u00b1 51 N and 432 \u00b1 43 N. The Young elastic modulus of group I and group II implants were 183.97 \u00b1 11.71 GPa and 143.72 \u00b1 15.93 GPa. The conometric joint was reported to have a higher strength than the regular internal hexagon implant connection. The study findings could have clinical implications for implant durability and peri-implant tissue stability in favor of the conical joint design.<\/jats:p>","DOI":"10.1563\/aaid-joi-d-25-00001","type":"journal-article","created":{"date-parts":[[2025,5,26]],"date-time":"2025-05-26T03:13:26Z","timestamp":1748229206000},"page":"356-360","source":"Crossref","is-referenced-by-count":1,"title":["Fracture Strength of Conometric Joint Implants Versus Internal Hexagon Abutment Joint Design: An In Vitro Study"],"prefix":"10.1563","volume":"51","author":[{"given":"Felice","family":"Lorusso","sequence":"first","affiliation":[{"name":"Department of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sergio Alexandre","family":"Gehrke","sequence":"additional","affiliation":[{"name":"Department of Research, Bioface\/PgO\/Universidad Cat\u00f3lica de Murcia, Montevideo, Uruguay"},{"name":"Department of Biotechnology, Universidad Cat\u00f3lica de Murcia, Murcia, Spain"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sergio Rexhep","family":"Tari","sequence":"additional","affiliation":[{"name":"Department of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antonio","family":"Scarano","sequence":"additional","affiliation":[{"name":"Department of Innovative Technologies in Medicine & Dentistry, University of Chieti-Pescara, Italy"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"434","reference":[{"key":"i1548-1336-51-4-356-b01","series-title":"J Dent","first-page":"8","article-title":"Short dental implants versus standard dental implants placed in the posterior jaws: a systematic review and meta-analysis","volume":"47","author":"Lemos","year":"2016","unstructured":"Lemos CAA,\nFerro-Alves ML,\nOkamoto R,\nMendon\u00e7a MR,\nPellizzer EP. Short dental implants versus standard dental implants placed in the posterior jaws: a systematic review and meta-analysis. J Dent. 2016;47:8\u201317."},{"key":"i1548-1336-51-4-356-b02","series-title":"J Periodontol","first-page":"1700","article-title":"A systematic review and meta-analysis on the effect of implant length on the survival of rough-surface dental implants","volume":"80","author":"Kotsovilis","year":"2009","unstructured":"Kotsovilis S,\nFourmousis I,\nKaroussis IK,\nBamia C. A systematic review and meta-analysis on the effect of implant length on the survival of rough-surface dental implants. J Periodontol. 2009;80:1700\u20131718."},{"key":"i1548-1336-51-4-356-b03","series-title":"Clin Oral Investig","first-page":"1403","article-title":"A systematic review of the clinical survival of zirconia implants","volume":"20","author":"Hashim","year":"2016","unstructured":"Hashim D,\nCionca N,\nCourvoisier DS,\nMombelli A. A systematic review of the clinical survival of zirconia implants. Clin Oral Investig. 2016;20:1403\u20131417."},{"key":"i1548-1336-51-4-356-b04","series-title":"Clin Implant Dent Relat Res","first-page":"839","article-title":"10-year survival and success rates of 511 titanium implants with a sandblasted and acid-etched surface: a retrospective study in 303 partially edentulous patients","volume":"14","author":"Buser","year":"2012","unstructured":"Buser D,\nJanner SFM,\nWittneben JG,\nBr\u00e4gger U,\nRamseier CA,\nSalvi GE. 10-year survival and success rates of 511 titanium implants with a sandblasted and acid-etched surface: a retrospective study in 303 partially edentulous patients. Clin Implant Dent Relat Res. 2012;14:839\u2013851."},{"key":"i1548-1336-51-4-356-b05","series-title":"Clin Implant Dent Relat Res","first-page":"345","article-title":"Peri-implant conditions and levels of advanced glycation end products among patients with different glycemic control","volume":"20","author":"Al-Sowygh","year":"2018","unstructured":"Al-Sowygh ZH,\nGhani SMA,\nSergis K,\nVohra F,\nAkram Z. Peri-implant conditions and levels of advanced glycation end products among patients with different glycemic control. Clin Implant Dent Relat Res. 2018;20:345\u2013351."},{"key":"i1548-1336-51-4-356-b06","series-title":"Periodontol 2000","first-page":"22","article-title":"Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions","volume":"73","author":"Bosshardt","year":"2017","unstructured":"Bosshardt DD,\nChappuis V,\nBuser D. Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions. Periodontol 2000. 2017;73:22\u201340."},{"key":"i1548-1336-51-4-356-b07","series-title":"Dent J (Basel)","article-title":"Correlation between implant geometry, bone density, and the insertion torque\/depth integral: a study on bovine ribs","volume":"7","author":"Di Stefano","year":"2019","unstructured":"Di Stefano DA,\nArosio P,\nPerrotti V,\nIezzi G,\nScarano A,\nPiattelli A. Correlation between implant geometry, bone density, and the insertion torque\/depth integral: a study on bovine ribs. Dent J (Basel). 2019;7."},{"key":"i1548-1336-51-4-356-b08","series-title":"Clin Oral Implants Res","first-page":"202","article-title":"Implant design and intraosseous stability of immediately placed implants: a human cadaver study","volume":"16","author":"Akkocaoglu","year":"2005","unstructured":"Akkocaoglu M,\nUysal S,\nTekdemir I,\nAkca K,\nCehreli MC. Implant design and intraosseous stability of immediately placed implants: a human cadaver study. Clin Oral Implants Res. 2005;16:202\u2013209."},{"key":"i1548-1336-51-4-356-b09","series-title":"J Craniofac Surg","first-page":"682","article-title":"Evaluation of microgap with three-dimensional x-ray microtomography: internal hexagon versus cone morse","volume":"27","author":"Scarano","year":"2016","unstructured":"Scarano A,\nMortellaro C,\nMavriqi L,\nPecci R,\nValbonetti L. Evaluation of microgap with three-dimensional x-ray microtomography: internal hexagon versus cone morse. J Craniofac Surg. 2016;27:682\u2013685."},{"key":"i1548-1336-51-4-356-b10","series-title":"Implant Dent","first-page":"270","article-title":"Comparative histological and histomorphometrical evaluation of marginal bone resorption around external hexagon and morse cone implants: an experimental study in dogs","volume":"23","author":"Castro","year":"2014","unstructured":"Castro DSM de,\nAraujo MAR de,\nBenfatti CAM, et al. Comparative histological and histomorphometrical evaluation of marginal bone resorption around external hexagon and morse cone implants: an experimental study in dogs. Implant Dent. 2014;23:270\u2013276."},{"key":"i1548-1336-51-4-356-b11","series-title":"J Periodontol","first-page":"1492","article-title":"Evaluation of the sealing capability of the implant healing screw by using real time volatile organic compounds analysis: internal hexagon versus cone morse","volume":"87","author":"Scarano","year":"2016","unstructured":"Scarano A,\nLorusso C,\nDi Giulio C,\nMazzatenta A. Evaluation of the sealing capability of the implant healing screw by using real time volatile organic compounds analysis: internal hexagon versus cone morse. J Periodontol. 2016;87:1492\u20131498."},{"key":"i1548-1336-51-4-356-b12","series-title":"J Prosthet Dent","first-page":"399","article-title":"Osseointegration and its experimental background","volume":"50","author":"Branemark","year":"1983","unstructured":"Branemark PI. Osseointegration and its experimental background. J Prosthet Dent. 1983;50:399\u2013410."},{"key":"i1548-1336-51-4-356-b13","series-title":"Scand J Plast Reconstr Surg Suppl","first-page":"1","article-title":"Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period","volume":"16","author":"Br\u00e5nemark","year":"1977","unstructured":"Br\u00e5nemark PI,\nHansson BO,\nAdell R, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl. 1977;16:1\u2013132."},{"key":"i1548-1336-51-4-356-b14","series-title":"Clin Oral Implants Res","first-page":"1108","article-title":"Marginal bone loss around implants with platform-switched morse-cone connection: a radiographic cross-sectional study","volume":"28","author":"Degidi","year":"2017","unstructured":"Degidi M,\nDaprile G,\nPiattelli A. Marginal bone loss around implants with platform-switched morse-cone connection: a radiographic cross-sectional study. Clin Oral Implants Res. 2017;28:1108\u20131112."},{"key":"i1548-1336-51-4-356-b15","series-title":"Clin Oral Implants Res","first-page":"371","article-title":"Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded morse cone connection implants: a histomorphometric study in dogs","volume":"21","author":"Barros","year":"2010","unstructured":"Barros RRM,\nNovaes AB,\nMuglia VA,\nIezzi G,\nPiattelli A. Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded morse cone connection implants: a histomorphometric study in dogs. Clin Oral Implants Res. 2010;21:371\u2013378."},{"issue":"1","key":"i1548-1336-51-4-356-b16","series-title":"Int J Implant Dent","article-title":"Removal torque pattern of a combined cone and octalobule index implant-abutment connection at different cyclic loading: an in-vitro experimental study","volume":"5","author":"Benjaboonyazit","year":"2019","unstructured":"Benjaboonyazit K,\nChaijareenont P,\nKhongkhunthian P. Removal torque pattern of a combined cone and octalobule index implant-abutment connection at different cyclic loading: an in-vitro experimental study. Int J Implant Dent. 2019;5:1."},{"key":"i1548-1336-51-4-356-b17","series-title":"Appl Sci","first-page":"1237","article-title":"Peri-implant bone stability around tapered implant prosthetic connection: a systematic review and meta-analysis comparing different cone morse and conometric implants angle contact and coupling interface designs","volume":"15","author":"Alla","year":"2025","unstructured":"Alla I,\nScarano A,\nSinjari B,\nXhajanka E,\nLorusso F. Peri-implant bone stability around tapered implant prosthetic connection: a systematic review and meta-analysis comparing different cone morse and conometric implants angle contact and coupling interface designs. Appl Sci. 2025;15:1237."},{"key":"i1548-1336-51-4-356-b18","series-title":"Clin Implant Dent Relat Res","first-page":"815","article-title":"Evaluation of a platform-switched morse taper connection for all-on-four or six treatment in edentulous or terminal dentition treatment: a retrospective study with 1-8\u2009years of follow-up","volume":"25","author":"Ding","year":"2023","unstructured":"Ding Y,\nZhou H,\nZhang W, et al. Evaluation of a platform-switched morse taper connection for all-on-four or six treatment in edentulous or terminal dentition treatment: a retrospective study with 1-8\u2009years of follow-up. Clin Implant Dent Relat Res. 2023;25:815\u2013828."},{"key":"i1548-1336-51-4-356-b19","series-title":"Biomedicines","article-title":"Crestal and subcrestal placement of morse cone implant-abutment connection implants: an in vitro finite element analysis (FEA) study","volume":"11","author":"Comuzzi","year":"2023","unstructured":"Comuzzi L,\nCeddia M,\nDi Pietro N, et al. Crestal and subcrestal placement of morse cone implant-abutment connection implants: an in vitro finite element analysis (FEA) study. Biomedicines. 2023;11."},{"key":"i1548-1336-51-4-356-b20","series-title":"Int J Periodont Restorative Dent","first-page":"e211","article-title":"A 30-year (1988-2018) retrospective microscopical evaluation of dental implants retrieved for different causes: a narrative review","volume":"40","author":"Tumedei","year":"2020","unstructured":"Tumedei M,\nPiattelli A,\nDegidi M,\nMangano C,\nIezzi G. A 30-year (1988-2018) retrospective microscopical evaluation of dental implants retrieved for different causes: a narrative review. Int J Periodont Restorative Dent. 2020;40:e211\u2013e227."},{"key":"i1548-1336-51-4-356-b21","series-title":"J Periodontol","first-page":"1492","article-title":"Evaluation of the sealing capability of the implant healing screw by using real time volatile organic compounds analysis: internal hexagon versus cone morse","volume":"87","author":"Scarano","year":"2016","unstructured":"Scarano A,\nLorusso C,\nDi Giulio C,\nMazzatenta A. Evaluation of the sealing capability of the implant healing screw by using real time volatile organic compounds analysis: internal hexagon versus cone morse. J Periodontol. 2016;87:1492\u20131498."},{"key":"i1548-1336-51-4-356-b22","series-title":"Comput Math Methods Med","first-page":"8074096","article-title":"Effects of different positions and angles of implants in maxillary edentulous jaw on surrounding bone stress under dynamic loading: a three-dimensional finite element analysis","volume":"2019","author":"Liu","year":"2019","unstructured":"Liu X,\nPang F,\nLi Y, et al. Effects of different positions and angles of implants in maxillary edentulous jaw on surrounding bone stress under dynamic loading: a three-dimensional finite element analysis. Comput Math Methods Med. 2019;2019:8074096."},{"key":"i1548-1336-51-4-356-b23","series-title":"J Biol Regul Homeost Agents","first-page":"115","article-title":"In vitro interface changes of two vs three narrow-diameter dental implants for screw-retained bar under fatigue loading test","volume":"33","author":"Lorusso","year":"2019","unstructured":"Lorusso F,\nMastrangelo F,\nInchingolo F,\nMortellaro C,\nScarano A. In vitro interface changes of two vs three narrow-diameter dental implants for screw-retained bar under fatigue loading test. J Biol Regul Homeost Agents. 2019;33:115\u2013120."},{"key":"i1548-1336-51-4-356-b24","series-title":"Int J Oral Maxillofac Implants","first-page":"47","article-title":"Evaluation of the mechanical reliability of different implant-abutment connections for single crowns according to the ISO 14801 fatigue test protocol","volume":"36","author":"Thom\u00e9","year":"2021","unstructured":"Thom\u00e9 G,\nTorres Gomes AF,\nde Moura MB,\nFelippi C,\nTrojan LC. Evaluation of the mechanical reliability of different implant-abutment connections for single crowns according to the ISO 14801 fatigue test protocol. Int J Oral Maxillofac Implants. 2021;36:47\u201354."},{"key":"i1548-1336-51-4-356-b25","series-title":"Clin Oral Implants Res","first-page":"290","article-title":"Three-year analysis of zirconia implants used for single-tooth replacement and three-unit fixed dental prostheses: a prospective multicenter study","volume":"29","author":"Balmer","year":"2018","unstructured":"Balmer M,\nSpies BC,\nVach K,\nKohal RJ,\nH\u00e4mmerle CHF,\nJung RE. Three-year analysis of zirconia implants used for single-tooth replacement and three-unit fixed dental prostheses: a prospective multicenter study. Clin Oral Implants Res. 2018;29:290\u2013299."},{"key":"i1548-1336-51-4-356-b26","series-title":"Clin Oral Invest","first-page":"102","article-title":"Failure of oral implants: aetiology, symptoms and influencing factors","volume":"2","author":"Duyck","year":"1998","unstructured":"Duyck J,\nNaert I. Failure of oral implants: aetiology, symptoms and influencing factors. Clin Oral Invest. 1998;2:102\u2013114."},{"key":"i1548-1336-51-4-356-b27","series-title":"J Clin Periodontol","first-page":"610","article-title":"Impact of local and systemic factors on the incidence of oral implant failures, up to abutment connection","volume":"34","author":"Alsaadi","year":"2007","unstructured":"Alsaadi G,\nQuirynen M,\nKom\u00e1rek A,\nvan Steenberghe D. Impact of local and systemic factors on the incidence of oral implant failures, up to abutment connection. J Clin Periodontol. 2007;34:610\u2013617."},{"key":"i1548-1336-51-4-356-b28","series-title":"Implant Dent","first-page":"232","article-title":"Management of a fractured, nonremovable implant: a clinical report with a 12-month follow-up","volume":"24","author":"Quaranta","year":"2015","unstructured":"Quaranta A,\nIezzi G,\nPoli O,\nPiattelli A,\nPerrotti V. Management of a fractured, nonremovable implant: a clinical report with a 12-month follow-up. Implant Dent. 2015;24:232\u2013235."},{"key":"i1548-1336-51-4-356-b29","series-title":"J Adv Prosthodont","first-page":"35","article-title":"Correlation between microleakage and screw loosening at implant-abutment connection","volume":"6","author":"Sahin","year":"2014","unstructured":"Sahin C,\nAyyildiz S. Correlation between microleakage and screw loosening at implant-abutment connection. J Adv Prosthodont. 2014;6:35."},{"key":"i1548-1336-51-4-356-b30","series-title":"J Mech Behav Biomed Mater","first-page":"104515","article-title":"Effect of macrogeometry and bone type on insertion torque, primary stability, surface topography damage and titanium release of dental implants during surgical insertion into artificial bone","volume":"119","author":"Silva","year":"2021","unstructured":"Silva GAF,\nFaot F,\nPossebon AP da R,\nda Silva WJ,\nDel Bel Cury AA. Effect of macrogeometry and bone type on insertion torque, primary stability, surface topography damage and titanium release of dental implants during surgical insertion into artificial bone. J Mech Behav Biomed Mater. 2021;119:104515."},{"key":"i1548-1336-51-4-356-b31","series-title":"J Oral Maxillofac Surg Med Pathol","first-page":"1","article-title":"Influence of surface modifications on the fracture resistance of aged zirconia implants: a systematic review of in vitro experimental studies","volume":"36","author":"Tardelli","year":"2024","unstructured":"Tardelli JDC,\nLoyolla CD,\nFerreira I,\nKreve S,\ndos Reis AC. Influence of surface modifications on the fracture resistance of aged zirconia implants: a systematic review of in vitro experimental studies. J Oral Maxillofac Surg Med Pathol. 2024;36:1\u201310."},{"key":"i1548-1336-51-4-356-b32","series-title":"J Periodontol","first-page":"491","article-title":"Bacterial leakage in implants with different implant-abutment connections: an in vitro study","volume":"83","author":"Assenza","year":"2012","unstructured":"Assenza B,\nTripodi D,\nScarano A, et al. Bacterial leakage in implants with different implant-abutment connections: an in vitro study. J Periodontol. 2012;83:491\u2013497."},{"key":"i1548-1336-51-4-356-b33","series-title":"Int J Oral Maxillofac Implants","first-page":"257","article-title":"Bone remodeling adjacent to morse cone-connection implants with platform switch: a fluorescence study in the dog mandible","volume":"24","author":"de Oliveira","year":"2009","unstructured":"de Oliveira RR,\nNovaes ABJ,\nTaba MJ,\nPapalexiou V,\nMuglia VA. Bone remodeling adjacent to morse cone-connection implants with platform switch: a fluorescence study in the dog mandible. Int J Oral Maxillofac Implants. 2009;24:257\u2013266."},{"key":"i1548-1336-51-4-356-b34","series-title":"Clin Oral Implants Res","first-page":"1108","article-title":"Marginal bone loss around implants with platform-switched morse-cone connection: a radiographic cross-sectional study","volume":"28","author":"Degidi","year":"2017","unstructured":"Degidi M,\nDaprile G,\nPiattelli A. Marginal bone loss around implants with platform-switched morse-cone connection: a radiographic cross-sectional study. Clin Oral Implants Res. 2017;28:1108\u20131112."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/51\/4\/article-p356.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/joi\/article-pdf\/doi\/10.1563\/aaid-joi-D-25-00001\/3518415\/aaid-joi-d-25-00001.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/51\/4\/article-p356.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/51\/4\/article-p356.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,15]],"date-time":"2025-08-15T00:31:44Z","timestamp":1755217904000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/51\/4\/article-p356.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8]]},"references-count":34,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-25-00001","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"type":"electronic","value":"1548-1336"},{"type":"print","value":"0160-6972"}],"subject":[],"published":{"date-parts":[[2025,8]]}}}