{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,12]],"date-time":"2026-10-12T12:11:25Z","timestamp":1791807085701,"version":"4.3.4"},"reference-count":34,"publisher":"American Academy of Implant Dentistry","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,8]]},"abstract":"<jats:p>\n                    This study aimed to compare the in vitro performance of anterior and posterior crowns with screw-retained polyetherketoneketone (PEKK) or zirconia abutments on two-piece zirconia implants. Monolithic incisor and molar zirconia crowns (n = 8 per group) were cemented on either PEKK or zirconia screw-retained abutments on zirconia implants. Molar and incisor crowns were also cemented on screw-retained titanium abutments on titanium implants as control. All specimens were subjected to combined mechanical loading (1.2 \u00d7 10\n                    <jats:sup>6<\/jats:sup>\n                    cycles of 50 N, f = 1 Hz) and thermal cycling (2 \u00d7 3000 \u00d7 5\u00b0C\/55\u00b0C cycles of 2 minutes). Complications, such as loosening of the crowns and fractures, were observed. The surviving specimens were subjected to a fracture test. Descriptive statistics were applied to complications, survival times, and fracture forces. The occurrence of complications depended significantly on location (anterior or posterior) and material (\n                    <jats:italic>P<\/jats:italic>\n                    &lt; .0001). While the incisor test groups presented higher failure rates for both PEKK and zirconia abutments, the survival rates of the molar-shaped crowns of both test groups were comparable with those of the titanium control group. This highly significant interaction is caused by a substantial difference in location for PEKK and zirconia (\n                    <jats:italic>P<\/jats:italic>\n                    &lt; .05). The titanium control group showed uniform performance independent of the simulated site. PEKK abutments showed high survival rates for in vitro simulated molar sites. Screw-retained zirconia abutments have shown higher complication rates, especially in simulated anterior sites. Neither zirconia nor PEKK abutments are recommended in clinical application for anterior indication.\n                  <\/jats:p>","DOI":"10.1563\/aaid-joi-d-25-00014","type":"journal-article","created":{"date-parts":[[2025,5,22]],"date-time":"2025-05-22T03:55:46Z","timestamp":1747886146000},"page":"370-375","source":"Crossref","is-referenced-by-count":2,"title":["The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study"],"prefix":"10.1563","volume":"51","author":[{"given":"Zeynab","family":"Ahmed","sequence":"first","affiliation":[{"name":"Department of Oral Surgery, University Center for Dental Medicine Basel (UZB), University of Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc","family":"Joos","sequence":"additional","affiliation":[{"name":"Department of Oral Surgery, University Center for Dental Medicine Basel (UZB), University of Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roland","family":"Joos","sequence":"additional","affiliation":[{"name":"Department of Optometry for the Statistical Analysis, University of Applied Sciences and Arts Northwestern Switzerland FHNW, Olten, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Rosentritt","sequence":"additional","affiliation":[{"name":"Department of Prosthetic Dentistry, UKR University Hospital Regensburg, Regensburg, Germany"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"K\u00fchl","sequence":"additional","affiliation":[{"name":"Department of Oral Surgery, University Center for Dental Medicine Basel (UZB), University of Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valentin","family":"Herber","sequence":"additional","affiliation":[{"name":"Department of Oral Surgery, University Center for Dental Medicine Basel (UZB), University of Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"434","reference":[{"key":"i1548-1336-51-4-370-b01","series-title":"Comm Dent Oral Epid","first-page":"161","article-title":"Oral and general health\u2010related quality of life with conventional and implant dentures","volume":"31","author":"Heydecke","year":"2003","unstructured":"Heydecke G,\nLocker D,\nAwad MA,\nLund JP,\nFeine JS. Oral and general health\u2010related quality of life with conventional and implant dentures. Comm Dent Oral Epid. 2003;31:161\u2013168. doi:10.1034\/j.1600-0528.2003.00029.x"},{"key":"i1548-1336-51-4-370-b02","series-title":"Clin Implant Dent Rel Res","first-page":"839","article-title":"10\u2010Year survival and success rates of 511 titanium implants with a sandblasted and acid\u2010etched surface: a retrospective study in 303 partially edentulous patients","volume":"14","author":"Buser","year":"2012","unstructured":"Buser D,\nJanner SFM,\nWittneben J,\nBr\u00e4gger U,\nRamseier CA,\nSalvi GE. 10\u2010Year survival and success rates of 511 titanium implants with a sandblasted and acid\u2010etched surface: a retrospective study in 303 partially edentulous patients. Clin Implant Dent Rel Res. 2012;14:839\u2013851. doi:10.1111\/j.1708-8208.2012.00456.x"},{"key":"i1548-1336-51-4-370-b03","series-title":"Scand J Plast Reconstr Surg","first-page":"81","article-title":"Intra-osseous anchorage of dental prostheses: I. Experimental studies","volume":"3","author":"Br\u00e5nemark","year":"1969","unstructured":"Br\u00e5nemark PI,\nBreine U,\nAdell R,\nHansson BO,\nLindstr\u00f6m J,\nOhlsson \u00c5. Intra-osseous anchorage of dental prostheses: I. Experimental studies. Scand J Plast Reconstr Surg. 1969;3:81\u2013100. doi:10.3109\/02844316909036699"},{"key":"i1548-1336-51-4-370-b04","series-title":"Clin Oral Implants Res","first-page":"823","article-title":"Titanium allergy in dental implant patients: a clinical study on 1500 consecutive patients","volume":"19","author":"Sicilia","year":"2008","unstructured":"Sicilia A,\nCuesta S,\nComa G, et al. Titanium allergy in dental implant patients: a clinical study on 1500 consecutive patients. Clin Oral Implants Res. 2008;19:823\u2013835. doi:10.1111\/j.1600-0501.2008.01544.x"},{"issue":"S18","key":"i1548-1336-51-4-370-b05","series-title":"Clin Oral Implants Res","first-page":"37","article-title":"What is the impact of titanium particles and biocorrosion on implant survival and complications? A critical review","volume":"29","author":"Mombelli","year":"2018","unstructured":"Mombelli A,\nHashim D,\nCionca N. What is the impact of titanium particles and biocorrosion on implant survival and complications? A critical review. Clin Oral Implants Res. 2018;29(S18):37\u201353. doi:10.1111\/clr.13305"},{"issue":"3","key":"i1548-1336-51-4-370-b06","series-title":"J Esthet Restor Dent","first-page":"159","article-title":"Clinical outcomes of implant abutments in the anterior region: a systematic review","volume":"25","author":"Bidra","year":"2013","unstructured":"Bidra AS,\nRungruanganunt P. Clinical outcomes of implant abutments in the anterior region: a systematic review. J Esthet Restor Dent. 2013;25(3):159\u2013176. doi:10.1111\/jerd.12031"},{"key":"i1548-1336-51-4-370-b07","series-title":"Clin Oral Implants Res","first-page":"281","article-title":"In vivo performance of zirconia and titanium implants: a histomorphometric study in mini pig maxillae","volume":"23","author":"Gahlert","year":"2012","unstructured":"Gahlert M,\nRoehling S,\nSprecher CM,\nKniha H,\nMilz S,\nBormann K. In vivo performance of zirconia and titanium implants: a histomorphometric study in mini pig maxillae. Clin Oral Implants Res. 2012;23:281\u2013286. doi:10.1111\/j.1600-0501.2011.02157.x"},{"key":"i1548-1336-51-4-370-b08","series-title":"J Periodontol","first-page":"1262","article-title":"Loaded custom-made zirconia and titanium implants show similar osseointegration: an animal experiment","volume":"75","author":"Kohal","year":"2004","unstructured":"Kohal RJ,\nWeng D,\nB\u00e4chle M,\nStrub JR. Loaded custom-made zirconia and titanium implants show similar osseointegration: an animal experiment. J Periodontol. 2004;75:1262\u20131268. doi:10.1902\/jop.2004.75.9.1262"},{"key":"i1548-1336-51-4-370-b09","series-title":"J Oral Implantol","first-page":"314","article-title":"Thirty years of translational research in zirconia dental implants: a systematic review of the literature","volume":"43","author":"Siddiqi","year":"2017","unstructured":"Siddiqi A,\nKhan AS,\nZafar S. Thirty years of translational research in zirconia dental implants: a systematic review of the literature. J Oral Implantol. 2017;43:314\u2013325. doi:10.1563\/aaid-joi-D-17-00016"},{"key":"i1548-1336-51-4-370-b10","series-title":"Clin Oral Implants Res","first-page":"365","article-title":"Zirconia compared to titanium dental implants in preclinical studies\u2014a systematic review and meta\u2010analysis","volume":"30","author":"Roehling","year":"2019","unstructured":"Roehling S,\nSchlegel KA,\nWoelfler H,\nGahlert M. Zirconia compared to titanium dental implants in preclinical studies\u2014a systematic review and meta\u2010analysis. Clin Oral Implants Res. 2019;30:365\u2013395. doi:10.1111\/clr.13425"},{"key":"i1548-1336-51-4-370-b11","series-title":"J Periodontol","first-page":"298","article-title":"In vitro biofilm formation on titanium and zirconia implant surfaces","volume":"88","author":"Roehling","year":"2017","unstructured":"Roehling S,\nAstasov-Frauenhoffer M,\nHauser-Gerspach I, et al. In vitro biofilm formation on titanium and zirconia implant surfaces. J Periodontol. 2017;88:298\u2013307. doi:10.1902\/jop.2016.160245"},{"key":"i1548-1336-51-4-370-b12","series-title":"Clin Oral Implants Res","first-page":"1233","article-title":"Two\u2010piece zirconia implants in the posterior mandible and maxilla: a cohort study with a follow\u2010up period of 9 years","volume":"33","author":"Brunello","year":"2022","unstructured":"Brunello G,\nRauch N,\nBecker K,\nHakimi AR,\nSchwarz F,\nBecker J. Two\u2010piece zirconia implants in the posterior mandible and maxilla: a cohort study with a follow\u2010up period of 9 years. Clin Oral Implants Res. 2022;33:1233\u20131244. doi:10.1111\/clr.14005"},{"key":"i1548-1336-51-4-370-b13","series-title":"Clin Oral Implants Res","first-page":"452","article-title":"Zirconia implants restored with single crowns or fixed dental prostheses: 5-year results of a prospective cohort investigation","volume":"31","author":"Balmer","year":"2020","unstructured":"Balmer M,\nSpies BC,\nKohal RJ,\nH\u00e4mmerle CHF,\nVach K,\nJung RE. Zirconia implants restored with single crowns or fixed dental prostheses: 5-year results of a prospective cohort investigation. Clin Oral Implants Res. 2020;31:452\u2013462. doi:10.1111\/clr.13581"},{"key":"i1548-1336-51-4-370-b14","series-title":"Materials (Basel)","first-page":"6738","article-title":"Immediate restoration of single-piece zirconia implants: a prospective case series-long-term results after 11 years of clinical function","volume":"14","author":"Steyer","year":"2021","unstructured":"Steyer E,\nHerber V,\nKoller M, et al. Immediate restoration of single-piece zirconia implants: a prospective case series-long-term results after 11 years of clinical function. Materials (Basel). 2021;14:6738. doi:10.3390\/ma14226738"},{"key":"i1548-1336-51-4-370-b15","series-title":"Clin Oral Implants Res","first-page":"277","article-title":"Bone response to functionally loaded, two\u2010piece zirconia implants: a preclinical histometric study","volume":"29","author":"Janner","year":"2018","unstructured":"Janner SFM,\nGahlert M,\nBosshardt DD, et al. Bone response to functionally loaded, two\u2010piece zirconia implants: a preclinical histometric study. Clin Oral Implants Res. 2018;29:277\u2013289. doi:10.1111\/clr.13112"},{"issue":"suppl 6","key":"i1548-1336-51-4-370-b16","series-title":"Clin Oral Implants Res","first-page":"163","article-title":"Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates","volume":"23","author":"Sailer","year":"2012","unstructured":"Sailer I,\nM\u00fchlemann S,\nZwahlen M,\nH\u00e4mmerle CHF,\nSchneider D. Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates. Clin Oral Implants Res. 2012;23(suppl 6):163\u2013201. doi:10.1111\/j.1600-0501.2012.02538.x"},{"issue":"S11","key":"i1548-1336-51-4-370-b17","series-title":"Clin Oral Implants Res","first-page":"139","article-title":"The effect of zirconia or titanium as abutment material on soft peri\u2010implant tissues: a systematic review and meta\u2010analysis","volume":"26","author":"Linkevicius","year":"2015","unstructured":"Linkevicius T,\nVaitelis J. The effect of zirconia or titanium as abutment material on soft peri\u2010implant tissues: a systematic review and meta\u2010analysis. Clin Oral Implants Res. 2015;26(S11):139\u2013147. doi:10.1111\/clr.12631"},{"key":"i1548-1336-51-4-370-b18","series-title":"J Dent","first-page":"94","article-title":"In vitro performance of one- and two-piece zirconia implant systems for anterior application","volume":"53","author":"Kammermeier","year":"2016","unstructured":"Kammermeier A,\nRosentritt M,\nBehr M,\nSchneider-Feyrer S,\nPreis V. In vitro performance of one- and two-piece zirconia implant systems for anterior application. J Dent. 2016;53:94\u2013101. doi:10.1016\/j.jdent.2016.08.004"},{"key":"i1548-1336-51-4-370-b19","series-title":"Biomaterials","first-page":"4845","article-title":"PEEK biomaterials in trauma, orthopedic, and spinal implants","volume":"28","author":"Kurtz","year":"2007","unstructured":"Kurtz SM,\nDevine JN. PEEK biomaterials in trauma, orthopedic, and spinal implants. Biomaterials. 2007;28:4845\u20134869. doi:10.1016\/j.biomaterials.2007.07.013"},{"key":"i1548-1336-51-4-370-b20","series-title":"J Dent","first-page":"1019","article-title":"In vitro performance of zirconia and titanium implant\/abutment systems for anterior application","volume":"42","author":"Rosentritt","year":"2014","unstructured":"Rosentritt M,\nHagemann A,\nHahnel S,\nBehr M,\nPreis V. In vitro performance of zirconia and titanium implant\/abutment systems for anterior application. J Dent. 2014;42:1019\u20131026. doi:10.1016\/j.jdent.2014.03.010"},{"key":"i1548-1336-51-4-370-b21","series-title":"Dental Materials","first-page":"765","article-title":"In vitro performance of two-piece zirconia implant systems for anterior application","volume":"32","author":"Preis","year":"2016","unstructured":"Preis V,\nKammermeier A,\nHandel G,\nRosentritt M. In vitro performance of two-piece zirconia implant systems for anterior application. Dental Materials. 2016;32:765\u2013774. doi:10.1016\/j.dental.2016.03.028"},{"key":"i1548-1336-51-4-370-b22","series-title":"Biomaterials","first-page":"8181","article-title":"Mechanical and biological characteristics of diamond-like carbon coated poly aryl-ether-ether-ketone","volume":"31","author":"Wang","year":"2010","unstructured":"Wang H,\nXu M,\nZhang W, et al. Mechanical and biological characteristics of diamond-like carbon coated poly aryl-ether-ether-ketone. Biomaterials. 2010;31:8181\u20138187. doi:10.1016\/j.biomaterials.2010.07.054"},{"key":"i1548-1336-51-4-370-b23","series-title":"Clin Oral Implants Res","first-page":"607","article-title":"Stability of screw-retention in two-piece zirconia implants: an in vitro study","volume":"31","author":"Joos","year":"2020","unstructured":"Joos M,\nSailer I,\nFilippi A,\nMukaddam K,\nRosentritt M,\nK\u00fchl S. Stability of screw-retention in two-piece zirconia implants: an in vitro study. Clin Oral Implants Res. 2020;31:607\u2013614. doi:10.1111\/clr.13597"},{"key":"i1548-1336-51-4-370-b24","series-title":"Clin Oral Investig","first-page":"1403","article-title":"A systematic review of the clinical survival of zirconia implants","volume":"20","author":"Hashim","year":"2016","unstructured":"Hashim D,\nCionca N,\nCourvoisier DS,\nMombelli A. A systematic review of the clinical survival of zirconia implants. Clin Oral Investig. 2016;20:1403\u20131417. doi:10.1007\/s00784-016-1853-9"},{"key":"i1548-1336-51-4-370-b25","series-title":"J Prosthetic Dent","first-page":"154","article-title":"In vitro evaluation of low-temperature aging effects and finishing procedures on the flexural strength and structural stability of Y-TZP dental ceramics","volume":"96","author":"Papanagiotou","year":"2006","unstructured":"Papanagiotou HP,\nMorgano SM,\nGiordano RA,\nPober R. In vitro evaluation of low-temperature aging effects and finishing procedures on the flexural strength and structural stability of Y-TZP dental ceramics. J Prosthetic Dent. 2006;96:154\u2013164. doi:10.1016\/j.prosdent.2006.08.004"},{"key":"i1548-1336-51-4-370-b26","series-title":"J Mech Behav Biomed Mater","first-page":"333","article-title":"Fracture strength of implant abutments after fatigue testing: a systematic review and a meta-analysis","volume":"62","author":"Coray","year":"2016","unstructured":"Coray R,\nZeltner M,\n\u00d6zcan M. Fracture strength of implant abutments after fatigue testing: a systematic review and a meta-analysis. J Mech Behav Biomed Mater. 2016;62:333\u2013346. doi:10.1016\/j.jmbbm.2016.05.011"},{"key":"i1548-1336-51-4-370-b27","series-title":"Clin Oral Implants Res","first-page":"695","article-title":"Two-piece zirconia implants supporting all-ceramic crowns: six-year results of a prospective cohort study","volume":"32","author":"Cionca","year":"2021","unstructured":"Cionca N,\nHashim D,\nMombelli A. Two-piece zirconia implants supporting all-ceramic crowns: six-year results of a prospective cohort study. Clin Oral Implants Res. 2021;32:695\u2013701. doi:10.1111\/clr.13734"},{"key":"i1548-1336-51-4-370-b28","series-title":"J Dent","first-page":"146","article-title":"Surface properties of titanium and zirconia dental implant materials and their effect on bacterial adhesion","volume":"40","author":"Al-Radha","year":"2012","unstructured":"Al-Radha ASD,\nDymock D,\nYounes C,\nO\u2019Sullivan D. Surface properties of titanium and zirconia dental implant materials and their effect on bacterial adhesion. J Dent. 2012;40:146\u2013153. doi:10.1016\/j.jdent.2011.12.006"},{"key":"i1548-1336-51-4-370-b29","series-title":"J Mech Behav Biomed Mater","first-page":"244","article-title":"The applicability of PEEK-based abutment screws","volume":"63","author":"Schwitalla","year":"2016","unstructured":"Schwitalla AD,\nAbou-Emara M,\nZimmermann T, et al. The applicability of PEEK-based abutment screws. J Mech Behav Biomed Mater. 2016;63:244\u2013251. doi:10.1016\/j.jmbbm.2016.06.024"},{"key":"i1548-1336-51-4-370-b30","series-title":"J Mech Behav Biomed Mater","first-page":"295","article-title":"Pressure behavior of different PEEK materials for dental implants","volume":"54","author":"Schwitalla","year":"2016","unstructured":"Schwitalla AD,\nSpintig T,\nKallage I,\nM\u00fcller WD. Pressure behavior of different PEEK materials for dental implants. J Mech Behav Biomed Mater. 2016;54:295\u2013304. doi:10.1016\/j.jmbbm.2015.10.003"},{"key":"i1548-1336-51-4-370-b31","series-title":"Int J Oral Maxillofac Implants","first-page":"313","article-title":"Mechanical stability of restorations supported by titanium base, zirconia, and polyetherketoneketone abutments on one- and two-piece zirconia implants","volume":"36","author":"Cantarella","year":"2021","unstructured":"Cantarella J,\nPitta J,\nMojon P,\nHicklin S,\nFehmer V,\nSailer I. Mechanical stability of restorations supported by titanium base, zirconia, and polyetherketoneketone abutments on one- and two-piece zirconia implants. Int J Oral Maxillofac Implants. 2021;36:313\u2013321. doi:10.11607\/jomi.8798"},{"key":"i1548-1336-51-4-370-b32","series-title":"Clin Implant Dent Rel Res","first-page":"107","article-title":"Implant deformation and implant\u2013abutment fracture resistance after standardized artificial aging: an in vitro study","volume":"25","author":"Zhai","year":"2023","unstructured":"Zhai Z,\nNakano T,\nChen Y,\nWatanabe S,\nMatsuoka T,\nIshigaki S. Implant deformation and implant\u2013abutment fracture resistance after standardized artificial aging: an in vitro study. Clin Implant Dent Rel Res. 2023;25:107\u2013117. doi:10.1111\/cid.13157"},{"key":"i1548-1336-51-4-370-b33","series-title":"Curr Oral Health Rep","first-page":"344","article-title":"Clinical longevity of zirconia implants with the focus on biomechanical and biological outcome","volume":"7","author":"Kohal","year":"2020","unstructured":"Kohal RJ,\nDennison DK. Clinical longevity of zirconia implants with the focus on biomechanical and biological outcome. Curr Oral Health Rep. 2020;7:344\u2013351. doi:10.1007\/s40496-020-00289-9"},{"key":"i1548-1336-51-4-370-b34","series-title":"Int J Implant Dent","first-page":"43","article-title":"German S3 guideline on the use of dental ceramic implants","volume":"8","author":"Thiem","year":"2022","unstructured":"Thiem DGE,\nStephan D,\nKniha K, et al. German S3 guideline on the use of dental ceramic implants. Int J Implant Dent. 2022;8:43. doi:10.1186\/s40729-022-00445-z"}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/51\/4\/article-p370.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/joi\/article-pdf\/doi\/10.1563\/aaid-joi-D-25-00014\/3518102\/aaid-joi-d-25-00014.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/51\/4\/article-p370.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/51\/4\/article-p370.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,8,15]],"date-time":"2025-08-15T00:32:01Z","timestamp":1755217921000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/51\/4\/article-p370.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8]]},"references-count":34,"journal-issue":{"issue":"4"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-25-00014","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"value":"1548-1336","type":"electronic"},{"value":"0160-6972","type":"print"}],"subject":[],"published":{"date-parts":[[2025,8]]}}}