{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,2]],"date-time":"2025-08-02T19:17:08Z","timestamp":1754162228378,"version":"3.41.2"},"reference-count":48,"publisher":"American Academy of Implant Dentistry","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:p>During and after implant surgery, pain is one of the most frequent complaints, and its intensity is thought to be influenced by a variety of factors. This study aimed to examine the association between insertion torque values and patients\u2019 pain levels measured with the visual analog scale and investigate the relationship between insertion torque, implant stability quotient, and Periotest values. This study was designed as a randomized, controlled, split-mouth clinical trial. Fifteen patients with bilateral single tooth loss in the posterior mandible were included. A total of 30 implants were randomly placed with high insertion torque (\u226550 Ncm) on one side and regular insertion torque (&lt;50 Ncm) on the other side in the same operation. The insertion torque, implant stability quotient, Periotest values, and preoperative anxiety and postoperative pain levels were recorded. Mean insertion torque values for high and regular insertion torque groups were 77.27 \u00b1 5.77 Ncm and 30.47 \u00b1 8.33 Ncm, respectively. Pain levels were higher in the high insertion torque group than the regular insertion torque group on the operation day (<jats:italic>p<\/jats:italic> = .016) and the following day (<jats:italic>p<\/jats:italic> = .007). Furthermore, correlations were observed between insertion torque, implant stability quotient, and Periotest values (<jats:italic>p<\/jats:italic> &lt; .05). The study found that implants placed with high insertion torque had higher reported pain levels on the day of the operation and the following day.<\/jats:p>","DOI":"10.1563\/aaid-joi-d-25-00033","type":"journal-article","created":{"date-parts":[[2025,5,9]],"date-time":"2025-05-09T16:49:41Z","timestamp":1746809381000},"page":"289-294","source":"Crossref","is-referenced-by-count":0,"title":["Impact of High Insertion Torque on Pain: A Randomized Split-Mouth Clinical Trial"],"prefix":"10.1563","volume":"51","author":[{"given":"Mehmet G\u00fcm\u00fc\u015f","family":"Kanmaz","sequence":"first","affiliation":[{"name":"Department of Periodontology, Faculty of Dentistry, Izmir Tinaztepe University, Izmir, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Serhat","family":"\u00c7\u0131narc\u0131k","sequence":"additional","affiliation":[{"name":"Department of Periodontology, Faculty of Dentistry, Ege University, Izmir, Turkey"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"434","reference":[{"key":"i1548-1336-51-3-289-b01","series-title":"Scand J Plast Reconstr Surg Suppl","first-page":"1","article-title":"Osseointegrated implants in the treatment of the edentulous jaw: experience from a 10-year period","volume":"16","author":"Br\u00e5nemark","year":"1977","unstructured":"Br\u00e5nemark PI,\nHansson BO,\nAdell R, et al. Osseointegrated implants in the treatment of the edentulous jaw: experience from a 10-year period. Scand J Plast Reconstr Surg Suppl. 1977;16:1\u2013132."},{"issue":"1","key":"i1548-1336-51-3-289-b02","series-title":"Periodontol 2000","first-page":"22","article-title":"Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions","volume":"73","author":"Bosshardt","year":"2017","unstructured":"Bosshardt DD,\nChappuis V,\nBuser D. Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions. Periodontol 2000. 2017;73(1):22\u201340."},{"key":"i1548-1336-51-3-289-b03","series-title":"Biomed Res Int","first-page":"7201093","article-title":"Correlation between insertion torque and implant stability quotient in tapered implants with knife-edge thread design","volume":"2018","author":"Baldi","year":"2018","unstructured":"Baldi D,\nLombardi T,\nColombo J, et al. Correlation between insertion torque and implant stability quotient in tapered implants with knife-edge thread design. Biomed Res Int. 2018;2018:7201093."},{"issue":"2","key":"i1548-1336-51-3-289-b04","series-title":"Oral Implantol (Rome)","first-page":"129","article-title":"Immediate loading implants: review of the critical aspects","volume":"10","author":"Tettamanti","year":"2017","unstructured":"Tettamanti L,\nAndrisani C,\nBassi MA,\nVinci R,\nSilvestre-Rangil J,\nTagliabue A. Immediate loading implants: review of the critical aspects. Oral Implantol (Rome). 2017;10(2):129\u2013139."},{"issue":"4","key":"i1548-1336-51-3-289-b05","series-title":"Eur J Dent","first-page":"618","article-title":"Relation between insertion torque and implant stability quotient: a clinical study","volume":"15","author":"do Vale Souza","year":"2021","unstructured":"do Vale Souza JP,\nde Moraes Melo Neto CL,\nPiacenza LT, et al. Relation between insertion torque and implant stability quotient: a clinical study. Eur J Dent. 2021;15(4):618\u2013623."},{"issue":"4","key":"i1548-1336-51-3-289-b06","series-title":"Clin Implant Dent Relat Res","first-page":"231","article-title":"Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data","volume":"10","author":"Turkyilmaz","year":"2008","unstructured":"Turkyilmaz I,\nAksoy U,\nMcGlumphy EA. Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data. Clin Implant Dent Relat Res. 2008;10(4):231\u2013237."},{"issue":"5","key":"i1548-1336-51-3-289-b07","series-title":"Int J Oral Maxillofac Implants","first-page":"743","article-title":"Methods used to assess implant stability: current status","volume":"22","author":"Atsumi","year":"2007","unstructured":"Atsumi M,\nPark SH,\nWang HL. Methods used to assess implant stability: current status. Int J Oral Maxillofac Implants. 2007;22(5):743\u2013754."},{"issue":"5","key":"i1548-1336-51-3-289-b08","series-title":"Clin Oral Implants Res","first-page":"577","article-title":"Stability of implants placed in fresh sockets versus healed alveolar sites: early findings","volume":"27","author":"Gehrke","year":"2016","unstructured":"Gehrke SA,\nda Silva Neto UT,\nRossetti PHO,\nWatinaga SE,\nGiro G,\nShibli JA. Stability of implants placed in fresh sockets versus healed alveolar sites: early findings. Clin Oral Implants Res. 2016;27(5):577\u2013582."},{"issue":"11","key":"i1548-1336-51-3-289-b09","series-title":"]. Zahnarztl Mitt","first-page":"1229","article-title":"Periotest\u2013a new measurement process for periodontal function","volume":"73","author":"Schulte","year":"1983","unstructured":"Schulte W,\nd\u2019Hoedt B,\nLukas D, et al. [Periotest\u2013a new measurement process for periodontal function]. Zahnarztl Mitt. 1983;73(11):1229\u20131230, 1233\u20131236, 1239\u20131240."},{"issue":"6","key":"i1548-1336-51-3-289-b10","series-title":"J Oral Implantol","first-page":"571","article-title":"Correlation of implant stability between two noninvasive methods using submerged and nonsubmerged healing protocols: a randomized clinical trial","volume":"46","author":"Aal","year":"2020","unstructured":"Aal MA,\nEl Far M,\nSheta NM, et al. Correlation of implant stability between two noninvasive methods using submerged and nonsubmerged healing protocols: a randomized clinical trial. J Oral Implantol. 2020;46(6):571\u2013579."},{"issue":"3","key":"i1548-1336-51-3-289-b11","series-title":"Int J Oral Maxillofac Implants","first-page":"525","article-title":"Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of both techniques in a clinical trial","volume":"23","author":"Zix","year":"2008","unstructured":"Zix J,\nHug S,\nKessler-Liechti G,\nMericske-Stern R. Measurement of dental implant stability by resonance frequency analysis and damping capacity assessment: comparison of both techniques in a clinical trial. Int J Oral Maxillofac Implants. 2008;23(3):525\u2013530."},{"issue":"4","key":"i1548-1336-51-3-289-b12","series-title":"Int J Oral Maxillofac Implants","first-page":"390","article-title":"Periotest method as a measure of osseointegrated oral implant stability","volume":"5","author":"Oliv\u00e9","year":"1990","unstructured":"Oliv\u00e9 J,\nAparicio C. Periotest method as a measure of osseointegrated oral implant stability. Int J Oral Maxillofac Implants. 1990;5(4):390\u2013400."},{"issue":"3","key":"i1548-1336-51-3-289-b13","series-title":"Clin Implant Dent Relat Res","first-page":"341","article-title":"The influence of insertion torque values on the failure and complication rates of dental implants: a systematic review and meta\u2010analysis","volume":"23","author":"Atieh","year":"2021","unstructured":"Atieh MA,\nBaqain ZH,\nTawse\u2010Smith A, et al. The influence of insertion torque values on the failure and complication rates of dental implants: a systematic review and meta\u2010analysis. Clin Implant Dent Relat Res. 2021;23(3):341\u2013360."},{"issue":"1","key":"i1548-1336-51-3-289-b14","series-title":"Sci Rep","first-page":"538","article-title":"Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles","volume":"12","author":"Gehrke","year":"2022","unstructured":"Gehrke SA,\nJ\u00fanior JA,\nTreichel TLE,\ndo Prado TD,\nDedavid BA,\nde Aza PN. Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles. Sci Rep. 2022;12(1):538."},{"issue":"2 Suppl","key":"i1548-1336-51-3-289-b15","series-title":"Int J Immunopathol Pharmacol","first-page":"65","article-title":"Assessment of pain associated with insertion torque of dental implants: a prospective, randomized-controlled study","volume":"24","author":"Scarano","year":"2011","unstructured":"Scarano A,\nPiattelli A,\nAssenza B,\nSollazzo V,\nLucchese A,\nCarinci F. Assessment of pain associated with insertion torque of dental implants: a prospective, randomized-controlled study. Int J Immunopathol Pharmacol. 2011;24(2 Suppl):65\u201369."},{"issue":"3","key":"i1548-1336-51-3-289-b16","series-title":"Br Dent J","first-page":"123","article-title":"Pre- and post-operative management of dental implant placement. Part 1: management of post-operative pain","volume":"217","author":"Bryce","year":"2014","unstructured":"Bryce G,\nBomfim DI,\nBassi GS. Pre- and post-operative management of dental implant placement. Part 1: management of post-operative pain. Br Dent J. 2014;217(3):123\u2013127."},{"issue":"4","key":"i1548-1336-51-3-289-b17","series-title":"Int J Oral Implantol (Berl)","first-page":"345","article-title":"Implant insertion torque and marginal bone loss: a systematic review and meta-analysis","volume":"13","author":"Roca-Millan","year":"2020","unstructured":"Roca-Millan E,\nGonz\u00e1lez-Navarro B,\nDom\u00ednguez-M\u00ednger J,\nMar\u00ed-Roig A,\nJan\u00e9-Salas E,\nL\u00f3pez-L\u00f3pez J. Implant insertion torque and marginal bone loss: a systematic review and meta-analysis. Int J Oral Implantol (Berl). 2020;13(4):345\u2013353."},{"issue":"2","key":"i1548-1336-51-3-289-b18","series-title":"J Clin Periodontol","first-page":"158","article-title":"Influence of low insertion torque values on survival rate of immediately loaded dental implants: a systematic review and meta-analysis","volume":"50","author":"Darriba","year":"2023","unstructured":"Darriba I,\nSeidel A,\nMoreno F, et al. Influence of low insertion torque values on survival rate of immediately loaded dental implants: a systematic review and meta-analysis. J Clin Periodontol. 2023;50(2):158\u2013169."},{"issue":"4","key":"i1548-1336-51-3-289-b19","series-title":"J Prosthet Dent","first-page":"490","article-title":"Clinical effect of the high insertion torque on dental implants: a systematic review and meta-analysis","volume":"126","author":"Lemos","year":"2021","unstructured":"Lemos CAA,\nVerri FR,\nde Oliveira Neto OB, et al. Clinical effect of the high insertion torque on dental implants: a systematic review and meta-analysis. J Prosthet Dent. 2021;126(4):490\u2013496."},{"issue":"6","key":"i1548-1336-51-3-289-b20","series-title":"Int Dent J","first-page":"367","article-title":"Further evidence for the reliability and validity of the Modified Dental Anxiety Scale","volume":"50","author":"Humphris","year":"2000","unstructured":"Humphris GM,\nFreeman R,\nCampbell J,\nTuutti H,\nD\u2019Souza V. Further evidence for the reliability and validity of the Modified Dental Anxiety Scale. Int Dent J. 2000;50(6):367\u2013370."},{"issue":"1","key":"i1548-1336-51-3-289-b21","series-title":"J Funct Biomater","article-title":"Methods to improve osseointegration of dental implants in low quality (type-iv) bone: an overview","volume":"9","author":"Alghamdi","year":"2018","unstructured":"Alghamdi HS. Methods to improve osseointegration of dental implants in low quality (type-iv) bone: an overview. J Funct Biomater. 2018;9(1)."},{"issue":"2","key":"i1548-1336-51-3-289-b22","series-title":"Clin Implant Dent Relat Res","first-page":"75","article-title":"On cutting torque measurements during implant placement: a 3-year clinical prospective study","volume":"1","author":"Friberg","year":"1999","unstructured":"Friberg B,\nSennerby L,\nGr\u00f6ndahl K,\nBergstr\u00f6m C,\nB\u00e4ck T,\nLekholm U. On cutting torque measurements during implant placement: a 3-year clinical prospective study. Clin Implant Dent Relat Res. 1999;1(2):75\u201383."},{"issue":"5","key":"i1548-1336-51-3-289-b23","series-title":"Int J Oral Maxillofac Implants","first-page":"646","article-title":"Br\u00e5nemark system implants in the posterior maxilla: clinical study of 660 implants followed for 5 to 12 years","volume":"15","author":"Bahat","year":"2000","unstructured":"Bahat O. Br\u00e5nemark system implants in the posterior maxilla: clinical study of 660 implants followed for 5 to 12 years. Int J Oral Maxillofac Implants. 2000;15(5):646\u2013653."},{"issue":"1","key":"i1548-1336-51-3-289-b24","series-title":"Clin Implant Dent Relat Res","first-page":"50","article-title":"Br\u00e5nemark implants and osteoporosis: a clinical exploratory study","volume":"3","author":"Friberg","year":"2001","unstructured":"Friberg B,\nEkestubbe A,\nMellstr\u00f6m D,\nSennerby L. Br\u00e5nemark implants and osteoporosis: a clinical exploratory study. Clin Implant Dent Relat Res. 2001;3(1):50\u201356."},{"issue":"5","key":"i1548-1336-51-3-289-b25","series-title":"Int J Oral Maxillofac Implants","first-page":"671","article-title":"Clinical outcome of Br\u00e5nemark system implants of various diameters: a retrospective study","volume":"17","author":"Friberg","year":"2002","unstructured":"Friberg B,\nEkestubbe A,\nSennerby L. Clinical outcome of Br\u00e5nemark system implants of various diameters: a retrospective study. Int J Oral Maxillofac Implants. 2002;17(5):671\u2013677."},{"issue":"5","key":"i1548-1336-51-3-289-b26","series-title":"Int J Oral Maxillofac Implants","first-page":"1126","article-title":"Relationship between primary stability and crestal bone loss of implants placed with high insertion torque: a 3-year prospective study","volume":"31","author":"De Santis","year":"2016","unstructured":"De Santis D,\nCucchi A,\nRigoni G,\nLonghi C,\nNocini PF. Relationship between primary stability and crestal bone loss of implants placed with high insertion torque: a 3-year prospective study. Int J Oral Maxillofac Implants. 2016;31(5):1126\u20131134."},{"issue":"4","key":"i1548-1336-51-3-289-b27","series-title":"Int J Oral Maxillofac Surg","first-page":"516","article-title":"Clinical outcome and bone healing of implants placed with high insertion torque: 12-month results from a multicenter controlled cohort study","volume":"42","author":"Grandi","year":"2013","unstructured":"Grandi T,\nGuazzi P,\nSamarani R,\nGrandi G. Clinical outcome and bone healing of implants placed with high insertion torque: 12-month results from a multicenter controlled cohort study. Int J Oral Maxillofac Surg. 2013;42(4):516\u2013520."},{"issue":"5","key":"i1548-1336-51-3-289-b28","series-title":"Clin Implant Dent Relat Res","first-page":"668","article-title":"Impact of insertion torque and implant neck design on peri-implant bone level: a randomized split-mouth trial","volume":"16","author":"Hof","year":"2014","unstructured":"Hof M,\nPommer B,\nStrbac GD,\nVasak C,\nAgis H,\nZechner W. Impact of insertion torque and implant neck design on peri-implant bone level: a randomized split-mouth trial. Clin Implant Dent Relat Res. 2014;16(5):668\u2013674."},{"issue":"3","key":"i1548-1336-51-3-289-b29","series-title":"Clin Implant Dent Relat Res","first-page":"322","article-title":"Longitudinal analysis on the effect of insertion torque on delayed single implants: a 3-year randomized clinical study","volume":"20","author":"Marconcini","year":"2018","unstructured":"Marconcini S,\nGiammarinaro E,\nToti P,\nAlfonsi F,\nCovani U,\nBarone A. Longitudinal analysis on the effect of insertion torque on delayed single implants: a 3-year randomized clinical study. Clin Implant Dent Relat Res. 2018;20(3):322\u2013332."},{"issue":"1","key":"i1548-1336-51-3-289-b30","series-title":"J Int Soc Prev Community Dent","first-page":"28","article-title":"Association of anxiety with pain perception following periodontal flap surgery","volume":"8","author":"Ahmadi","year":"2018","unstructured":"Ahmadi M,\nKiakojori A,\nMoudi S. Association of anxiety with pain perception following periodontal flap surgery. J Int Soc Prev Community Dent. 2018;8(1):28\u201333."},{"issue":"2","key":"i1548-1336-51-3-289-b31","series-title":"J Orofac Pain","first-page":"126","article-title":"Concordance among different pain scales in patients with dental pain","volume":"26","author":"dos Santos Calderon","year":"2012","unstructured":"dos Santos Calderon P,\nPeixoto RF,\nGomes VM, et al. Concordance among different pain scales in patients with dental pain. J Orofac Pain. 2012;26(2):126\u2013131."},{"key":"i1548-1336-51-3-289-b32","series-title":"Bioscience J","first-page":"e39036","article-title":"Pain factors related to dental implant surgery: a 7-day observational clinical study","volume":"39","author":"Rizzatto","year":"2023","unstructured":"Rizzatto LV,\nDi Dom\u00eanico MB,\nCollares K,\nDe Carli JP,\nCorazza PH. Pain factors related to dental implant surgery: a 7-day observational clinical study. Bioscience J. 2023;39:e39036."},{"issue":"sp2","key":"i1548-1336-51-3-289-b33","series-title":"Internat J Pharmaceut Res","article-title":"Pain experience in dental implant patients with high and moderate insertion torques (clinical prospective standardized blinded study)","volume":"12","author":"Al Hawwaz","year":"2020","unstructured":"Al Hawwaz ZM,\nAbdul Rahman AM. Pain experience in dental implant patients with high and moderate insertion torques (clinical prospective standardized blinded study). Internat J Pharmaceut Res. 2020;12(sp2)."},{"issue":"2","key":"i1548-1336-51-3-289-b34","series-title":"J Periodontol","first-page":"239","article-title":"Assessment of pain associated with the surgical placement of dental implants","volume":"78","author":"Al\u2010Khabbaz","year":"2007","unstructured":"Al\u2010Khabbaz AK,\nGriffin TJ,\nAl\u2010Shammari KF. Assessment of pain associated with the surgical placement of dental implants. J Periodontol. 2007;78(2):239\u2013246."},{"issue":"3","key":"i1548-1336-51-3-289-b35","series-title":"Community Dent Health","first-page":"143","article-title":"The Modified Dental Anxiety Scale: validation and United Kingdom norms","volume":"12","author":"Humphris","year":"1995","unstructured":"Humphris GM,\nMorrison T,\nLindsay SJ. The Modified Dental Anxiety Scale: validation and United Kingdom norms. Community Dent Health. 1995;12(3):143\u2013150."},{"key":"i1548-1336-51-3-289-b36","series-title":"BMC Oral Health","first-page":"20","article-title":"The modified dental anxiety scale: UK general public population norms in 2008 with further psychometrics and effects of age","volume":"9","author":"Humphris","year":"2009","unstructured":"Humphris GM,\nDyer TA,\nRobinson PG. The modified dental anxiety scale: UK general public population norms in 2008 with further psychometrics and effects of age. BMC Oral Health. 2009;9:20."},{"issue":"1","key":"i1548-1336-51-3-289-b37","series-title":"Community Dent Health","first-page":"40","article-title":"Psychometric properties of the modified dental anxiety scale: an independent replication","volume":"22","author":"Newton","year":"2005","unstructured":"Newton JT,\nEdwards JC. Psychometric properties of the modified dental anxiety scale: an independent replication. Community Dent Health. 2005;22(1):40\u201342."},{"issue":"9","key":"i1548-1336-51-3-289-b38","series-title":"J Periodontol","first-page":"1079","article-title":"Impact of anxiety on pain perception associated with periodontal and implant surgery in a private practice","volume":"83","author":"Fardal","year":"2012","unstructured":"Fardal \u00d8,\nMcCulloch CA. Impact of anxiety on pain perception associated with periodontal and implant surgery in a private practice. J Periodontol. 2012;83(9):1079\u20131085."},{"issue":"6","key":"i1548-1336-51-3-289-b39","series-title":"Int J Oral Maxillofac Implants","first-page":"943","article-title":"Pain and anxiety following the placement of dental implants","volume":"21","author":"Hashem","year":"2006","unstructured":"Hashem AA,\nClaffey NM,\nO\u2019Connell B. Pain and anxiety following the placement of dental implants. Int J Oral Maxillofac Implants. 2006;21(6):943\u2013950."},{"issue":"6","key":"i1548-1336-51-3-289-b40","series-title":"Implant Dent","first-page":"502","article-title":"Impact of anxiety parameters on prospective and experienced pain intensity in implant surgery","volume":"21","author":"Weisensee","year":"2012","unstructured":"Weisensee W,\nScheer M,\nM\u00fcller L, et al. Impact of anxiety parameters on prospective and experienced pain intensity in implant surgery. Implant Dent. 2012;21(6):502\u2013506."},{"issue":"4","key":"i1548-1336-51-3-289-b41","series-title":"Clin Oral Implants Res","first-page":"437","article-title":"Early detection of implant healing process using resonance frequency analysis","volume":"14","author":"Huang","year":"2003","unstructured":"Huang H,\nChiu C,\nYeh C,\nLin C,\nLin L,\nLee S. Early detection of implant healing process using resonance frequency analysis. Clin Oral Implants Res. 2003;14(4):437\u2013443."},{"issue":"5","key":"i1548-1336-51-3-289-b42","series-title":"Clin Oral Implants Res","first-page":"601","article-title":"Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants","volume":"14","author":"Nkenke","year":"2003","unstructured":"Nkenke E,\nHahn M,\nWeinzierl K,\nRadespiel\u2010Tr\u00f6ger M,\nNeukam FW,\nEngelke K. Implant stability and histomorphometry: a correlation study in human cadavers using stepped cylinder implants. Clin Oral Implants Res. 2003;14(5):601\u2013609."},{"issue":"1","key":"i1548-1336-51-3-289-b43","series-title":"Clin Oral Implants Res","first-page":"75","article-title":"Resonance frequency analysis and damping capacity assessment","volume":"17","author":"Lachmann","year":"2006","unstructured":"Lachmann S,\nJ\u00e4ger B,\nAxmann D,\nGomez\u2010Roman G,\nGroten M,\nWeber H. Resonance frequency analysis and damping capacity assessment. Clin Oral Implants Res. 2006;17(1):75\u201379."},{"issue":"6","key":"i1548-1336-51-3-289-b44","series-title":"Int J Periodontics Restorative Dent","first-page":"833","article-title":"The correlation between immediate implant insertion torque and implant stability quotient","volume":"36","author":"Levin","year":"2016","unstructured":"Levin BP. The correlation between immediate implant insertion torque and implant stability quotient. Int J Periodontics Restorative Dent. 2016;36(6):833\u2013840."},{"issue":"1","key":"i1548-1336-51-3-289-b45","series-title":"Clin Implant Dent Relat Res","first-page":"26","article-title":"Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: a systematic review","volume":"20","author":"Lages","year":"2018","unstructured":"Lages FS,\nDouglas\u2010de Oliveira DW,\nCosta FO. Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: a systematic review. Clin Implant Dent Relat Res. 2018;20(1):26\u201333."},{"issue":"3","key":"i1548-1336-51-3-289-b46","series-title":"J Periodontol","first-page":"281","article-title":"Relationship between implant stability measurements obtained by two different devices: a systematic review","volume":"88","author":"Andreotti","year":"2017","unstructured":"Andreotti AM,\nGoiato MC,\nNobrega AS, et al. Relationship between implant stability measurements obtained by two different devices: a systematic review. J Periodontol. 2017;88(3):281\u2013288."},{"issue":"6","key":"i1548-1336-51-3-289-b47","series-title":"J Craniofac Surg","first-page":"e548","article-title":"Primary and secondary stability of single short implants","volume":"29","author":"Alonso","year":"2018","unstructured":"Alonso FR,\nTriches DF,\nMezzomo LAM,\nTeixeira ER,\nShinkai RSA. Primary and secondary stability of single short implants. J Craniofac Surg. 2018;29(6):e548\u2013e551."},{"issue":"1","key":"i1548-1336-51-3-289-b48","series-title":"Biomed Tech (Berl)","first-page":"1","article-title":"Correlation between Periotest value and implant stability quotient: a systematic review","volume":"69","author":"Semenzin Rodrigues","year":"2024","unstructured":"Semenzin Rodrigues A,\nde Moraes Melo Neto CL,\nSantos Januzzi M,\nDos Santos DM,\nGoiato MC. Correlation between Periotest value and implant stability quotient: a systematic review. Biomed Tech (Berl). 2024;69(1):1\u201310."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/51\/3\/article-p289.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/joi\/article-pdf\/doi\/10.1563\/aaid-joi-D-25-00033\/3516510\/10.1563_aaid-joi-d-25-00033.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/51\/3\/article-p289.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/51\/3\/article-p289.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T00:30:55Z","timestamp":1753835455000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/51\/3\/article-p289.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6]]},"references-count":48,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-25-00033","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"type":"electronic","value":"1548-1336"},{"type":"print","value":"0160-6972"}],"subject":[],"published":{"date-parts":[[2025,6]]}}}