{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T03:16:35Z","timestamp":1787022995403,"version":"build-2736575974"},"reference-count":38,"publisher":"American Academy of Implant Dentistry","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2025,6]]},"abstract":"<jats:p>This study evaluated the stress distributions of subperiosteal implants (SPI) made of titanium and polyetheretherketone (PEEK) in 1-piece and 2-piece designs in edentulous and severely atrophic mandibles subjected to trauma forces. This study applied 4 treatment methods to a severely atrophic edentulous mandibular model. Subperiosteal implant designs made of PEEK consisting of 1 piece in model 1 and two in model 2 were used. Subperiosteal implant designs made of titanium composed of 1 piece in model 3 and two in model 4 were used. Each of the subperiosteal implants was fixed on the mandibular model with 14 osteosynthesis screws placed in the tension lines of the mandible. A traumatic force of 2000 N was applied to the mandibular prosthesis in the anteroposterior direction. Maximum principal stress (Pmax), minimum principal stress (Pmin), and Von Mises stress (VMs) values were measured in MPa. In this study, model 3 showed the highest Pmax value in the symphysis region (45.888 MPa), whereas the values in the other models were similar. The mandibular condyle had the highest Pmax in model 2 (941.338 MPa) and the lowest in model 3 (905.756 MPa). All models compared the Pmin values measured in the symphysis, alveolar crest, and condyle region. The VM stress values on the abutments and abutment screws were lower and more stable in PEEK SPI models than titanium SPI models. However, VMs values on titanium SPI metal frameworks were lower than PEEK SPI models. In this finite element analysis, 1-piece PEEK SPI were the most advantageous design regarding mandibular fracture risk when evaluated under traumatic forces. PEEK SPI treatment may provide a less invasive treatment model for patients with severely atrophic mandibles. Additionally, 2-piece subperiosteal implants may provide greater design flexibility in clinical applications and offer advantages in stress distribution, expanding the range of treatment options available to clinicians.<\/jats:p>","DOI":"10.1563\/aaid-joi-d-25-00073","type":"journal-article","created":{"date-parts":[[2025,5,16]],"date-time":"2025-05-16T04:45:01Z","timestamp":1747370701000},"page":"295-303","source":"Crossref","is-referenced-by-count":3,"title":["Comparison of Subperiosteal Implant Designs Applied to Atrophic and Edentulous Mandible Under Traumatic Forces: 3D Finite Element Analysis"],"prefix":"10.1563","volume":"51","author":[{"given":"Ilg\u0131n","family":"Ar\u0131","sequence":"first","affiliation":[{"name":"Faculty of Dentistry, Department of Oral and Maxillofacial Surgery Hacettepe University, Ankara, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G\u00fclin","family":"Acar","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Department of Oral and Maxillofacial Surgery Hacettepe University, Ankara, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"\u0130pek Dilara","family":"Ba\u015f","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Department of Oral and Maxillofacial Surgery Hacettepe University, Ankara, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emre","family":"Tosun","sequence":"additional","affiliation":[{"name":"Faculty of Dentistry, Department of Oral and Maxillofacial Surgery Hacettepe University, Ankara, T\u00fcrkiye"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"434","reference":[{"key":"i1548-1336-51-3-295-b01","series-title":"Dent Traumatol","first-page":"352","article-title":"Evaluation of the pattern of fracture formation from trauma to the human mandible with finite element analysis. Part 1: symphysis region","volume":"39","author":"Sancar","year":"2023","unstructured":"Sancar B,\n\u00c7etiner Y,\nDay\u0131 E. Evaluation of the pattern of fracture formation from trauma to the human mandible with finite element analysis. Part 1: symphysis region. Dent Traumatol. 2023;39:352\u2013360."},{"key":"i1548-1336-51-3-295-b02","series-title":"Head Face Med","first-page":"1","article-title":"Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis","volume":"13","author":"Ayali","year":"2017","unstructured":"Ayali A,\nBilginaylar K. Evaluating the biomechanical effects of implant diameter in case of facial trauma to an edentulous atrophic mandible: a 3D finite element analysis. Head Face Med. 2017;13:1\u20137."},{"key":"i1548-1336-51-3-295-b03","series-title":"Oral Maxillofac Surg","first-page":"115","article-title":"Complications related to bone augmentation procedures of localized defects in the alveolar ridge: a retrospective clinical study","volume":"20","author":"Jensen","year":"2016","unstructured":"Jensen AT,\nJensen SS,\nWorsaae N. Complications related to bone augmentation procedures of localized defects in the alveolar ridge: a retrospective clinical study. Oral Maxillofac Surg. 2016;20:115\u2013122."},{"key":"i1548-1336-51-3-295-b04","series-title":"J Prosthet Dent","first-page":"826","article-title":"Are short implants (\u2264 8.5 mm) reliable in the rehabilitation of completely edentulous patients: a systematic review and meta-analysis","volume":"131","author":"Liang","year":"2024","unstructured":"Liang L,\nWu X,\nYan Q,\nShi B. Are short implants (\u2264 8.5 mm) reliable in the rehabilitation of completely edentulous patients: a systematic review and meta-analysis. J Prosthet Dent. 2024;131:826\u2013832."},{"key":"i1548-1336-51-3-295-b05","series-title":"J Am Dent Assoc","first-page":"310","article-title":"A longitudinal study of the survival of all-on-4 implants in the mandible with up to 10 years of follow-up","volume":"142","author":"Malo","year":"2011","unstructured":"Malo P,\nde Ara\u00fajo Nobre M,\nLopes A,\nMoss SM,\nMolina GJ. A longitudinal study of the survival of all-on-4 implants in the mandible with up to 10 years of follow-up. J Am Dent Assoc. 2011;142:310\u2013320."},{"key":"i1548-1336-51-3-295-b06","series-title":"Int J Oral Maxillofac Surg","first-page":"533","article-title":"Implant-prosthetic rehabilitation of the atrophic posterior mandible with additively manufactured custom-made subperiosteal implants: a cohort study","volume":"53","author":"Vaira","year":"2024","unstructured":"Vaira L,\nBiglio A,\nFavro A, et al. Implant-prosthetic rehabilitation of the atrophic posterior mandible with additively manufactured custom-made subperiosteal implants: a cohort study. Int J Oral Maxillofac Surg. 2024;53:533\u2013540."},{"key":"i1548-1336-51-3-295-b07","series-title":"Dent J","first-page":"241","article-title":"Clinical outcomes of CAD-CAM subperiosteal implants for the rehabilitation of atrophic jaws","volume":"12","author":"Gasparini","year":"2024","unstructured":"Gasparini G,\nTodaro M,\nDe Angelis P, et al. Clinical outcomes of CAD-CAM subperiosteal implants for the rehabilitation of atrophic jaws. Dent J. 2024;12:241."},{"key":"i1548-1336-51-3-295-b08","series-title":"J Maxillofac Surg","first-page":"14","article-title":"Mandibular osteosynthesis by miniature screwed plates via a buccal approach","volume":"6","author":"Champy","year":"1978","unstructured":"Champy M,\nLodde J,\nSchmitt R,\nJaeger J,\nMuster D. Mandibular osteosynthesis by miniature screwed plates via a buccal approach. J Maxillofac Surg. 1978;6:14\u201321."},{"key":"i1548-1336-51-3-295-b09","series-title":"J Prosthet Dent","first-page":"33","article-title":"Forty years of experience with subperiosteal implant dentures in 41 edentulous patients","volume":"75","author":"Bodine","year":"1996","unstructured":"Bodine RL,\nYanase RT,\nBodine A. Forty years of experience with subperiosteal implant dentures in 41 edentulous patients. J Prosthet Dent. 1996;75:33\u201344."},{"key":"i1548-1336-51-3-295-b10","series-title":"Dent Traumatol","first-page":"437","article-title":"Evaluation of the pattern of fracture formation from trauma to the human mandible with finite element analysis. Part 2: the corpus and the angle regions","volume":"39","author":"Sancar","year":"2023","unstructured":"Sancar B,\n\u00c7etiner Y,\nDay\u0131 E. Evaluation of the pattern of fracture formation from trauma to the human mandible with finite element analysis. Part 2: the corpus and the angle regions. Dent Traumatol. 2023;39:437\u2013447."},{"key":"i1548-1336-51-3-295-b11","series-title":"Int J Oral Maxillofac Surg","first-page":"588","article-title":"Does the presence of an unerupted lower third molar influence the risk of mandibular angle and condylar fractures","volume":"45","author":"Antic","year":"2016","unstructured":"Antic S,\nSaveljic I,\nNikolic D, et al. Does the presence of an unerupted lower third molar influence the risk of mandibular angle and condylar fractures? Int J Oral Maxillofac Surg. 2016;45:588\u2013592."},{"key":"i1548-1336-51-3-295-b12","series-title":"Int J Oral Maxillofac Surg","first-page":"474","article-title":"Do erupted third molars weaken the mandibular angle after trauma to the chin region? A 3D finite element study","volume":"42","author":"Bezerra","year":"2013","unstructured":"Bezerra TP,\nJunior FS,\nScarparo H,\nCosta FWG,\nStudart-Soares E. Do erupted third molars weaken the mandibular angle after trauma to the chin region? A 3D finite element study. Int J Oral Maxillofac Surg. 2013;42:474\u2013480."},{"key":"i1548-1336-51-3-295-b13","series-title":"J Cranio-Maxillofac Surg","first-page":"870","article-title":"Impact of the lower third molar presence and position on the fragility of mandibular angle and condyle: a three-dimensional finite element study","volume":"43","author":"Antic","year":"2015","unstructured":"Antic S,\nVukicevic AM,\nMilasinovic M, et al. Impact of the lower third molar presence and position on the fragility of mandibular angle and condyle: a three-dimensional finite element study. J Cranio-Maxillofac Surg. 2015;43:870\u2013878."},{"key":"i1548-1336-51-3-295-b14","series-title":"J Cranio-Maxillofac Surg","first-page":"1929","article-title":"The epidemiology of edentulous atrophic mandibular fractures in Europe","volume":"47","author":"Brucoli","year":"2019","unstructured":"Brucoli M,\nBoffano P,\nRomeo I, et al. The epidemiology of edentulous atrophic mandibular fractures in Europe. J Cranio-Maxillofac Surg. 2019;47:1929\u20131934."},{"key":"i1548-1336-51-3-295-b15","series-title":"Oral Surg Oral Med Oral Pathol Oral Radiol Endod","first-page":"553","article-title":"Etiology and management of mandibular fractures associated with endosteal implants in the atrophic mandible","volume":"89","author":"Raghoebar","year":"2000","unstructured":"Raghoebar GM,\nStellingsma K,\nBatenburg R,\nVissink A. Etiology and management of mandibular fractures associated with endosteal implants in the atrophic mandible. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2000;89:553\u2013559."},{"key":"i1548-1336-51-3-295-b16","series-title":"J Oral Maxillofac Surg","first-page":"131","article-title":"An epidemiologic survey of facial fractures and concomitant injury","volume":"47","author":"Prather","year":"1989","unstructured":"Prather J. An epidemiologic survey of facial fractures and concomitant injury. J Oral Maxillofac Surg. 1989;47:131."},{"key":"i1548-1336-51-3-295-b17","series-title":"Int J Oral Maxillofac Surg","first-page":"214","article-title":"Facial fractures occurring in a medium-sized metropolitan area: recent trends","volume":"20","author":"Vetter","year":"1991","unstructured":"Vetter JD,\nTopazian RG,\nGoldberg MH,\nSmith DG. Facial fractures occurring in a medium-sized metropolitan area: recent trends. Int J Oral Maxillofac Surg. 1991;20:214\u2013216."},{"key":"i1548-1336-51-3-295-b18","series-title":"J Oral Maxillofac Surg","first-page":"352","article-title":"Defining predictable patterns of craniomaxillofacial injury in the elderly: analysis of 1,047 patients","volume":"72","author":"Zelken","year":"2014","unstructured":"Zelken JA,\nKhalifian S,\nMundinger GS, et al. Defining predictable patterns of craniomaxillofacial injury in the elderly: analysis of 1,047 patients. J Oral Maxillofac Surg. 2014;72:352\u2013361."},{"key":"i1548-1336-51-3-295-b19","series-title":"Oral Surg Oral Med Oral Pathol Oral Radiol","first-page":"619","article-title":"Management of fractures of the atrophic mandible: a case series","volume":"119","author":"Flores-Hidalgo","year":"2015","unstructured":"Flores-Hidalgo A,\nAltay MA,\nAtencio IC, et al. Management of fractures of the atrophic mandible: a case series. Oral Surg Oral Med Oral Pathol Oral Radiol. 2015;119:619\u2013627."},{"key":"i1548-1336-51-3-295-b20","series-title":"J Oral Biol Craniofac Res","first-page":"200","article-title":"Finite element analysis: a boon to dentistry","volume":"4","author":"Trivedi","year":"2014","unstructured":"Trivedi S. Finite element analysis: a boon to dentistry. J Oral Biol Craniofac Res. 2014;4:200\u2013203."},{"key":"i1548-1336-51-3-295-b21","series-title":"J Cranio-Maxillofac Surg","first-page":"303","article-title":"A three-dimensional computer model of the human mandible in two simulated standard trauma situations","volume":"32","author":"Torreira","year":"2004","unstructured":"Torreira MG,\nFernandez JR. A three-dimensional computer model of the human mandible in two simulated standard trauma situations. J Cranio-Maxillofac Surg. 2004;32:303\u2013307."},{"key":"i1548-1336-51-3-295-b22","series-title":"J Oral Maxillofac Surg","first-page":"683","article-title":"Finite-element analysis of 3 situations of trauma in the human edentulous mandible","volume":"73","author":"de Mello Santos","year":"2015","unstructured":"de Mello Santos LS,\nRossi AC,\nFreire AR,\nMatoso RI,\nCaria PHF,\nPrado FB. Finite-element analysis of 3 situations of trauma in the human edentulous mandible. J Oral Maxillofac Surg. 2015;73:683\u2013691."},{"key":"i1548-1336-51-3-295-b23","series-title":"BioMed Res Int","first-page":"1","article-title":"Custom\u2010made direct metal laser sintering titanium subperiosteal implants: a retrospective clinical study on 70 patients","volume":"1","author":"Cerea","year":"2018","unstructured":"Cerea M,\nDolcini GA. Custom\u2010made direct metal laser sintering titanium subperiosteal implants: a retrospective clinical study on 70 patients. BioMed Res Int. 2018;1:1\u201311."},{"key":"i1548-1336-51-3-295-b24","series-title":"Int J Implant Dent","first-page":"4","article-title":"Clinical performance of additively manufactured subperiosteal implants: a systematic review","volume":"10","author":"Anitua","year":"2024","unstructured":"Anitua E,\nEguia A,\nStaudigl C,\nAlkhraisat MH. Clinical performance of additively manufactured subperiosteal implants: a systematic review. Int J Implant Dent. 2024;10:4."},{"key":"i1548-1336-51-3-295-b25","series-title":"J Oral Implantol","first-page":"743","article-title":"PEEK dental implants: a review of the literature","volume":"39","author":"Schwitalla","year":"2013","unstructured":"Schwitalla A,\nM\u00fcller W-D. PEEK dental implants: a review of the literature. J Oral Implantol. 2013;39:743\u2013749."},{"key":"i1548-1336-51-3-295-b26","series-title":"Int J Mol Sci","first-page":"5426","article-title":"Current strategies to improve the bioactivity of PEEK","volume":"15","author":"Ma","year":"2014","unstructured":"Ma R,\nTang T. Current strategies to improve the bioactivity of PEEK. Int J Mol Sci. 2014;15:5426\u20135445."},{"key":"i1548-1336-51-3-295-b27","series-title":"J Maxillofac Oral Surg","first-page":"315","article-title":"Analysis of patterns and treatment strategies for mandibular condyle fractures: review of 175 condyle fractures with review of literature","volume":"12","author":"Reddy","year":"2013","unstructured":"Reddy NVV,\nReddy PB,\nRajan R, et al. Analysis of patterns and treatment strategies for mandibular condyle fractures: review of 175 condyle fractures with review of literature. J Maxillofac Oral Surg. 2013;12:315\u2013320."},{"key":"i1548-1336-51-3-295-b28","series-title":"Forensic Sci Int Rep","first-page":"100252","article-title":"Blunt force trauma in the human mandible: an experimental investigation","volume":"5","author":"Goots","year":"2022","unstructured":"Goots A,\nIsa MI,\nFenton TW,\nWei F. Blunt force trauma in the human mandible: an experimental investigation. Forensic Sci Int Rep. 2022;5:100252."},{"key":"i1548-1336-51-3-295-b29","series-title":"Clin Implant Dent Relat Res","first-page":"208","article-title":"PEEK materials as an alternative to titanium in dental implants: a systematic review","volume":"21","author":"Mishra","year":"2019","unstructured":"Mishra S,\nChowdhary R. PEEK materials as an alternative to titanium in dental implants: a systematic review. Clin Implant Dent Relat Res. 2019;21:208\u2013222."},{"key":"i1548-1336-51-3-295-b30","series-title":"Dent J","first-page":"35","article-title":"PEEK with reinforced materials and modifications for dental implant applications","volume":"5","author":"Rahmitasari","year":"2017","unstructured":"Rahmitasari F,\nIshida Y,\nKurahashi K,\nMatsuda T,\nWatanabe M,\nIchikawa T. PEEK with reinforced materials and modifications for dental implant applications. Dent J. 2017;5:35."},{"key":"i1548-1336-51-3-295-b31","series-title":"Int J Oral Maxillofac Surg","first-page":"658","article-title":"Titanium and polyether ether ketone (PEEK) patient-specific sub-periosteal implants: two novel approaches for rehabilitation of the severely atrophic anterior maxillary ridge","volume":"47","author":"Mounir","year":"2018","unstructured":"Mounir M,\nAtef M,\nAbou-Elfetouh A,\nHakam M. Titanium and polyether ether ketone (PEEK) patient-specific sub-periosteal implants: two novel approaches for rehabilitation of the severely atrophic anterior maxillary ridge. Int J Oral Maxillofac Surg. 2018;47:658\u2013664."},{"key":"i1548-1336-51-3-295-b32","series-title":"J Prosthet Dent","first-page":"562","article-title":"Polyetheretherketone subperiosteal implant retaining a maxillary fixed prosthesis: A case series","volume":"132","author":"El-Sawy","year":"2022","unstructured":"El-Sawy MA,\nELgamal ME,\nAhmed WM,\nEl-Daker MA,\nHegazy SA. Polyetheretherketone subperiosteal implant retaining a maxillary fixed prosthesis: A case series. J Prosthet Dent. 2022;132:562\u2013569."},{"key":"i1548-1336-51-3-295-b33","series-title":"Int J Oral Maxillofac Surg","first-page":"108","article-title":"Evolutionary steps in the design and biofunctionalization of the additively manufactured sub-periosteal jaw implant \u2018AMSJI\u2019 for the maxilla","volume":"48","author":"Mommaerts","year":"2019","unstructured":"Mommaerts M. Evolutionary steps in the design and biofunctionalization of the additively manufactured sub-periosteal jaw implant \u2018AMSJI\u2019 for the maxilla. Int J Oral Maxillofac Surg. 2019;48:108\u2013114."},{"key":"i1548-1336-51-3-295-b34","series-title":"J Pers Med","first-page":"1","article-title":"Long-term clinical outcomes of 3D-Printed subperiosteal titanium implants: a 6-year follow-up","volume":"5","author":"Onic\u0103","year":"2024","unstructured":"Onic\u0103 N,\nBudal\u0103 DG,\nBaciu E-R, et al. Long-term clinical outcomes of 3D-Printed subperiosteal titanium implants: a 6-year follow-up. J Pers Med. 2024;5:1\u201313."},{"key":"i1548-1336-51-3-295-b35","series-title":"Oral Maxillofac Surg","first-page":"69","article-title":"The atrophic edentulous alveolus. A preliminary study on a new generation of subperiosteal implants","volume":"27","author":"Dimitroulis","year":"2023","unstructured":"Dimitroulis G,\nGupta B,\nWilson I,\nHart C. The atrophic edentulous alveolus. A preliminary study on a new generation of subperiosteal implants. Oral Maxillofac Surg. 2023;27:69\u201378."},{"key":"i1548-1336-51-3-295-b36","series-title":"Oral Maxillofac Surg","first-page":"1063","article-title":"Subperiosteal implants constructed with digital technology: a systematic review","volume":"28","author":"A El-Sawy","year":"2024","unstructured":"A El-Sawy M,\nA Hegazy S. Subperiosteal implants constructed with digital technology: a systematic review. Oral Maxillofac Surg. 2024;28:1063\u20131075."},{"key":"i1548-1336-51-3-295-b37","series-title":"J Pers Med","first-page":"294","article-title":"Exceptional cases demand exceptional personalized solutions: the next level in dental rehabilitation","volume":"14","author":"Gellrich","year":"2024","unstructured":"Gellrich N-C,\nKorn P,\nJehn P,\nNeuhaus M,\nLentge F,\nRahlf B. Exceptional cases demand exceptional personalized solutions: the next level in dental rehabilitation. J Pers Med. 2024;14:294."},{"key":"i1548-1336-51-3-295-b38","series-title":"Eur J Trauma","first-page":"110","article-title":"Trauma and fracture of the mandible: effects of etiologic factors on fracture patterns","volume":"30","author":"Copcu","year":"2004","unstructured":"Copcu E,\nSisman N,\nOztan Y. Trauma and fracture of the mandible: effects of etiologic factors on fracture patterns. Eur J Trauma. 2004;30:110\u2013115."}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/51\/3\/article-p295.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/meridian.allenpress.com\/joi\/article-pdf\/doi\/10.1563\/aaid-joi-D-25-00073\/3517264\/aaid-joi-d-25-00073.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/51\/3\/article-p295.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/51\/3\/article-p295.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,7,30]],"date-time":"2025-07-30T00:30:45Z","timestamp":1753835445000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/51\/3\/article-p295.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,6]]},"references-count":38,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-25-00073","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"value":"1548-1336","type":"electronic"},{"value":"0160-6972","type":"print"}],"subject":[],"published":{"date-parts":[[2025,6]]}}}