{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T11:59:23Z","timestamp":1789041563775,"version":"build-2803163510"},"reference-count":35,"publisher":"American Academy of Implant Dentistry","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2026,6]]},"abstract":"<jats:p>\n                    Dynamic navigation systems offer significant potential to enhance dental implant surgery, particularly for novice surgeons. To compare the accuracy and time consumption of freehand implant surgery (group A), static computer-assisted implant surgery (sCAIS; group B), and dynamic computer-assisted implant surgery (dCAIS; group C) performed by novice and experienced surgeons in vitro. A total of 192 implants (n = 192) were placed in polyurethane mandibular models under simulated clinical conditions by 16 participants, divided into 2 groups. Implants were placed after CBCT-based virtual planning. Postoperative surface scans were superimposed on the preoperative planning data to evaluate the angular and spatial deviations. A linear mixed model analysis, followed by descriptive statistics, was used to determine the influence of experience level, method, and operative site on various accuracy parameters. The applied implant placement methodology showed a statistically significant influence on the angular deviation, the 3D deviation at the base and tip, the bucco-oral and mesial-distal deviation at the implant base (\n                    <jats:italic>P<\/jats:italic>\n                    &lt; .05). The lowest mean angular deviation was recorded in group B with 3.12\u00b0 (\u00b11.49\u00b0). The regions where the implants were placed had a significant influence on the angular deviation parameter (\n                    <jats:italic>P<\/jats:italic>\n                    &lt; .001). The level of experience showed a statistically significant difference in the angular deviation of the placed implants (\n                    <jats:italic>P<\/jats:italic>\n                    &lt; .001) and in the bucco-oral deviation at the implant tip (\n                    <jats:italic>P<\/jats:italic>\n                    = .04). Novice surgeons consistently required significantly more time compared with experienced surgeons. Both CAIS approaches hold potential to improve implant placement outcomes, showing significant improvements over freehand techniques.\n                  <\/jats:p>","DOI":"10.1563\/aaid-joi-d-25-00120","type":"journal-article","created":{"date-parts":[[2025,10,29]],"date-time":"2025-10-29T01:08:26Z","timestamp":1761700106000},"page":"185-195","source":"Crossref","is-referenced-by-count":1,"title":["Impact of Operator Experience on Accuracy and Procedure Time in Dynamic Navigation, Static-Guided, Freehand Implant Placement: An In Vitro Study"],"prefix":"10.1563","volume":"52","author":[{"given":"Kensuke","family":"Inoue","sequence":"first","affiliation":[{"name":"Department of Oral Surgery, University Center for Dental Medicine, University of Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Olivia","family":"Hasler","sequence":"additional","affiliation":[{"name":"Department of Oral Surgery, University Center for Dental Medicine, University of Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maximilian","family":"Struwe","sequence":"additional","affiliation":[{"name":"Department of Oral Surgery, University Center for Dental Medicine, University of Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wadim","family":"Leontiev","sequence":"additional","affiliation":[{"name":"Department of Periodontology, Endodontology and Cariology, University Center for Dental Medicine, University of Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dorothea","family":"Dagassan-Berndt","sequence":"additional","affiliation":[{"name":"Dental Imaging, University Center for Dental Medicine, University of Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastian","family":"K\u00fchl","sequence":"additional","affiliation":[{"name":"Department of Oral Surgery, University Center for Dental Medicine, University of Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Valentin","family":"Herber","sequence":"additional","affiliation":[{"name":"Department of Oral Surgery, University Center for Dental Medicine, University of Basel, Basel, Switzerland"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"434","reference":[{"key":"i1548-1336-52-3-185-b01","series-title":"J Periodontol","first-page":"493","article-title":"Outcome of early dental implant placement versus other dental implant placement protocols: a systematic review and meta-analysis","volume":"90","author":"Bassir","year":"2019","unstructured":"Bassir SH,\nEl Kholy K,\nChen CY,\nLee KH,\nIntini G. Outcome of early dental implant placement versus other dental implant placement protocols: a systematic review and meta-analysis. J Periodontol. 2019;90:493\u2013506. doi:10.1002\/JPER.18-0338"},{"key":"i1548-1336-52-3-185-b02","series-title":"Advances in Materials Science and Engineering","first-page":"1","article-title":"Free-hand versus surgical guide implant placement","author":"Afshari","year":"2022","unstructured":"Afshari A,\nShahmohammadi R,\nMosaddad SA, et al. Free-hand versus surgical guide implant placement. In: \nTebyaniyan H, ed. Advances in Materials Science and Engineering. Hoboken, New Jersey, USA: John Wiley & Sons, Inc; 2022:1\u201312. doi:10.1155\/2022\/6491134"},{"key":"i1548-1336-52-3-185-b03","series-title":"Dental Implant Complications","first-page":"209","article-title":"Esthetic complications due to implant malpositions: etiology, prevention, and treatment","author":"Chen","year":"2015","unstructured":"Chen ST,\nBuser D,\nDent M. Esthetic complications due to implant malpositions: etiology, prevention, and treatment. In: \nFroum SJ, ed. Dental Implant Complications. 1st ed. Wiley; 2015:209\u2013232. doi:10.1002\/9781119140474.ch11"},{"key":"i1548-1336-52-3-185-b04","series-title":"J Oral Maxillofac Surg","first-page":"15","article-title":"Prosthodontic complications related to compromised implant placement","volume":"52","author":"Drago","year":"1994","unstructured":"Drago CJ. Prosthodontic complications related to compromised implant placement. J Oral Maxillofac Surg. 1994;52:15\u201322. doi:10.1016\/0278-2391(94)90006-x"},{"key":"i1548-1336-52-3-185-b05","series-title":"Clin Oral Implants Res","first-page":"183","article-title":"Inferior alveolar nerve injury associated with implant surgery","volume":"24","author":"Juodzbalys","year":"2013","unstructured":"Juodzbalys G,\nWang HL,\nSabalys G,\nSidlauskas A,\nGalindo-Moreno P. Inferior alveolar nerve injury associated with implant surgery. Clin Oral Implants Res. 2013;24:183\u2013190. doi:10.1111\/j.1600-0501.2011.02314.x"},{"key":"i1548-1336-52-3-185-b06","series-title":"J Clin Med","first-page":"1490","article-title":"Guided dental implant surgery: systematic review","volume":"12","author":"Dioguardi","year":"2023","unstructured":"Dioguardi M,\nSpirito F,\nQuarta C, et al. Guided dental implant surgery: systematic review. J Clin Med. 2023;12:1490. doi:10.3390\/jcm12041490"},{"issue":"suppl 4","key":"i1548-1336-52-3-185-b07","series-title":"Clin Oral Implants Res","first-page":"73","article-title":"A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry","volume":"20","author":"Schneider","year":"2009","unstructured":"Schneider D,\nMarquardt P,\nZwahlen M,\nJung RE. A systematic review on the accuracy and the clinical outcome of computer-guided template-based implant dentistry. Clin Oral Implants Res. 2009;20(suppl 4):73\u201386. doi:10.1111\/j.1600-0501.2009.01788.x"},{"issue":"suppl","key":"i1548-1336-52-3-185-b08","series-title":"Int J Oral Maxillofac Implants","first-page":"126","article-title":"Consensus statements and recommended clinical procedures regarding computer-assisted implant dentistry","volume":"24","author":"H\u00e4mmerle","year":"2009","unstructured":"H\u00e4mmerle CHF,\nStone P,\nJung RE,\nKapos T,\nBrodala N. Consensus statements and recommended clinical procedures regarding computer-assisted implant dentistry. Int J Oral Maxillofac Implants. 2009;24(suppl):126\u2013131."},{"key":"i1548-1336-52-3-185-b09","series-title":"J Periodontol","first-page":"152","article-title":"Early implant placement with simultaneous guided bone regeneration following single-tooth extraction in the esthetic zone: 12-month results of a prospective study with 20 consecutive patients","volume":"80","author":"Buser","year":"2009","unstructured":"Buser D,\nHalbritter S,\nHart C, et al. Early implant placement with simultaneous guided bone regeneration following single-tooth extraction in the esthetic zone: 12-month results of a prospective study with 20 consecutive patients. J Periodontol. 2009;80:152\u2013162. doi:10.1902\/jop.2009.080360"},{"issue":"suppl 16","key":"i1548-1336-52-3-185-b10","series-title":"Clin Oral Implants Res","first-page":"436","article-title":"Group 5 ITI Consensus Report: digital technologies","volume":"29","author":"Wismeijer","year":"2018","unstructured":"Wismeijer D,\nJoda T,\nFl\u00fcgge T, et al. Group 5 ITI Consensus Report: digital technologies. Clin Oral Implants Res. 2018;29(suppl 16):436\u2013442. doi:10.1111\/clr.13309"},{"key":"i1548-1336-52-3-185-b11","series-title":"Int J Oral Maxillofac Surg","first-page":"85","article-title":"How does an error in positioning the template affect the accuracy of implants inserted using a single fixed mucosa-supported stereolithographic surgical guide","volume":"43","author":"Cassetta","year":"2014","unstructured":"Cassetta M,\nDi Mambro A,\nGiansanti M,\nStefanelli LV,\nBarbato E. How does an error in positioning the template affect the accuracy of implants inserted using a single fixed mucosa-supported stereolithographic surgical guide? Int J Oral Maxillofac Surg. 2014;43:85\u201392. doi:10.1016\/j.ijom.2013.06.012"},{"key":"i1548-1336-52-3-185-b12","series-title":"Clin Oral Implants Res","first-page":"121","article-title":"Comparison of heat generation between guided and conventional implant surgery for single and sequential drilling protocols\u2014an in vitro study","volume":"30","author":"Fr\u00f6sch","year":"2019","unstructured":"Fr\u00f6sch L,\nMukaddam K,\nFilippi A,\nZitzmann NU,\nK\u00fchl S. Comparison of heat generation between guided and conventional implant surgery for single and sequential drilling protocols\u2014an in vitro study. Clin Oral Implants Res. 2019;30:121\u2013130. doi:10.1111\/clr.13398"},{"key":"i1548-1336-52-3-185-b13","series-title":"Bioengineering","first-page":"1177","article-title":"Efficacy of novel digital-based surgical guide in the limited interocclusal distance","volume":"11","author":"Park","year":"2024","unstructured":"Park WJ,\nKim KS,\nCho SH,\nLee SY. Efficacy of novel digital-based surgical guide in the limited interocclusal distance. Bioengineering. 2024;11:1177. doi:10.3390\/bioengineering11121177"},{"key":"i1548-1336-52-3-185-b14","series-title":"Int J Comput Dent","first-page":"139","article-title":"Dynamic navigation: a prospective clinical trial to evaluate the accuracy of implant placement","volume":"22","author":"Pellegrino","year":"2019","unstructured":"Pellegrino G,\nTaraschi V,\nAndrea Z,\nFerri A,\nMarchetti C. Dynamic navigation: a prospective clinical trial to evaluate the accuracy of implant placement. Int J Comput Dent. 2019;22:139\u2013147."},{"key":"i1548-1336-52-3-185-b15","series-title":"J Clin Med","first-page":"1808","article-title":"Accuracy of computer-assisted dynamic navigation in implant placement with a fully digital approach: a prospective clinical trial","volume":"10","author":"Edelmann","year":"2021","unstructured":"Edelmann C,\nWetzel M,\nKnipper A,\nLuthardt RG,\nSchnutenhaus S. Accuracy of computer-assisted dynamic navigation in implant placement with a fully digital approach: a prospective clinical trial. J Clin Med. 2021;10:1808. doi:10.3390\/jcm10091808"},{"key":"i1548-1336-52-3-185-b16","series-title":"Clin Oral Implants Res","first-page":"438","article-title":"Accuracy of dental implant placement with or without the use of a dynamic navigation assisted system: a randomized clinical trial","volume":"34","author":"Jorba-Garc\u00eda","year":"2023","unstructured":"Jorba-Garc\u00eda A,\nBara-Casaus JJ,\nCamps-Font O,\nS\u00e1nchez-Garc\u00e9s M\u00c1,\nFigueiredo R,\nValmaseda-Castell\u00f3n E. Accuracy of dental implant placement with or without the use of a dynamic navigation assisted system: a randomized clinical trial. Clin Oral Implants Res. 2023;34:438\u2013449. doi:10.1111\/clr.14050"},{"key":"i1548-1336-52-3-185-b17","series-title":"Clin Oral Implants Res","first-page":"1","article-title":"The accuracy of dental implant placement with different methods of computer\u2010assisted implant surgery: a network meta\u2010analysis of clinical studies","volume":"36","author":"Mahardawi","year":"2025","unstructured":"Mahardawi B,\nJiaranuchart S,\nArunjaroensuk S,\nDhanesuan K,\nMattheos N,\nPimkhaokham A. The accuracy of dental implant placement with different methods of computer\u2010assisted implant surgery: a network meta\u2010analysis of clinical studies. Clin Oral Implants Res. 2025;36:1\u201316. doi:10.1111\/clr.14357"},{"key":"i1548-1336-52-3-185-b18","series-title":"Instr Course Lect","first-page":"623","article-title":"Understanding and taking control of surgical learning curves","volume":"65","author":"Gofton","year":"2016","unstructured":"Gofton WT,\nPapp SR,\nGofton T,\nBeaul\u00e9 PE. Understanding and taking control of surgical learning curves. Instr Course Lect. 2016;65:623\u2013631."},{"issue":"2","key":"i1548-1336-52-3-185-b19","series-title":"J Surg Educ","first-page":"450","article-title":"Preparation for challenging cases: what differentiates expert from novice surgeons","volume":"78","author":"Ghaderi","year":"2021","unstructured":"Ghaderi I,\nKorovin L,\nFarrell TM. Preparation for challenging cases: what differentiates expert from novice surgeons? J Surg Educ. 2021;78(2):450\u2013461. doi:10.1016\/j.jsurg.2020.08.019"},{"key":"i1548-1336-52-3-185-b20","series-title":"Int J Surg","first-page":"773","article-title":"Surgical experts: born or made","volume":"11","author":"Sadideen","year":"2013","unstructured":"Sadideen H,\nAlvand A,\nSaadeddin M,\nKneebone R. Surgical experts: born or made? Int J Surg. 2013;11:773\u2013778. doi:10.1016\/j.ijsu.2013.07.001"},{"key":"i1548-1336-52-3-185-b21","series-title":"Clin Oral Implants Res","first-page":"555","article-title":"Evaluation of the accuracy, surgical time, and learning curve of freehand, static, and dynamic computer-assisted implant surgery in an in vitro study","volume":"36","author":"Werny","year":"2025","unstructured":"Werny JG,\nFan S,\nDiaz L, et al. Evaluation of the accuracy, surgical time, and learning curve of freehand, static, and dynamic computer-assisted implant surgery in an in vitro study. Clin Oral Implants Res. 2025;36:555\u2013565. doi:10.1111\/clr.14403"},{"key":"i1548-1336-52-3-185-b22","series-title":"Int J Environ Res Public Health","first-page":"3244","article-title":"Accuracy of Computer-Assisted Dynamic Navigation as a Function of Different Intraoral Reference Systems: An In Vitro Study","volume":"18","author":"Schnutenhaus","year":"2021","unstructured":"Schnutenhaus S,\nKnipper A,\nWetzel M,\nEdelmann C,\nLuthardt R. Accuracy of Computer-Assisted Dynamic Navigation as a Function of Different Intraoral Reference Systems: An In Vitro Study. Int J Environ Res Public Health. 2021;18:3244. doi:10.3390\/ijerph18063244"},{"key":"i1548-1336-52-3-185-b23","series-title":"Int J Implant Dent","first-page":"45","article-title":"Comparison of implant placement accuracy in two different preoperative digital workflows: navigated vs. pilot-drill-guided surgery","volume":"7","author":"Spille","year":"2021","unstructured":"Spille J,\nJin F,\nBehrens E, et al. Comparison of implant placement accuracy in two different preoperative digital workflows: navigated vs. pilot-drill-guided surgery. Int J Implant Dent. 2021;7:45. doi:10.1186\/s40729-021-00322-1"},{"key":"i1548-1336-52-3-185-b24","series-title":"Clin Oral Implants Res","first-page":"196","article-title":"Accuracy of a dynamic navigation system for dental implantation with two different workflows and intraoral markers compared to static-guided implant surgery: an in-vitro study","volume":"34","author":"Struwe","year":"2023","unstructured":"Struwe M,\nLeontiev W,\nConnert T, et al. Accuracy of a dynamic navigation system for dental implantation with two different workflows and intraoral markers compared to static-guided implant surgery: an in-vitro study. Clin Oral Implants Res. 2023;34:196\u2013208. doi:10.1111\/clr.14030"},{"issue":"suppl","key":"i1548-1336-52-3-185-b25","series-title":"Int J Oral Maxillofac Implants","first-page":"25","article-title":"Computer technology applications in surgical implant dentistry: a systematic review","volume":"29","author":"Tahmaseb","year":"2014","unstructured":"Tahmaseb A,\nWismeijer D,\nCoucke W,\nDerksen W. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants. 2014;29(suppl):25\u201342. doi:10.11607\/jomi.2014suppl.g1.2"},{"key":"i1548-1336-52-3-185-b26","series-title":"Periodontol 2000","first-page":"7","article-title":"Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions","volume":"73","author":"Buser","year":"2017","unstructured":"Buser D,\nSennerby L,\nDe Bruyn H. Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions. Periodontol 2000. 2017;73:7\u201321. doi:10.1111\/prd.12185"},{"key":"i1548-1336-52-3-185-b27","series-title":"Clin Oral Implants Res","first-page":"763","article-title":"Accuracy of full guided vs. half-guided implant surgery","volume":"24","author":"K\u00fchl","year":"2013","unstructured":"K\u00fchl S,\nZ\u00fcrcher S,\nMahid T,\nM\u00fcller-Gerbl M,\nFilippi A,\nCattin P. Accuracy of full guided vs. half-guided implant surgery. Clin Oral Implants Res. 2013;24:763\u2013769. doi:10.1111\/j.1600-0501.2012.02484.x"},{"key":"i1548-1336-52-3-185-b28","series-title":"J Prosthetic Dentist","article-title":"Comparison of learning curve for anterior and posterior implant placement using dynamic computer-assisted surgical implant placement in novice and experienced operators: an in vitro trial","author":"Kundaechanont","year":"2024","unstructured":"Kundaechanont P,\nSerichetaphonges P,\nPimkhaokham A,\nChengprapakorn W. Comparison of learning curve for anterior and posterior implant placement using dynamic computer-assisted surgical implant placement in novice and experienced operators: an in vitro trial. J Prosthetic Dentist. 2024:S0022391324007200. doi:10.1016\/j.prosdent.2024.10.025"},{"issue":"suppl 11","key":"i1548-1336-52-3-185-b29","series-title":"Clin Oral Implants Res","first-page":"69","article-title":"Computer-supported implant planning and guided surgery: a narrative review","volume":"26","author":"Vercruyssen","year":"2015","unstructured":"Vercruyssen M,\nLaleman I,\nJacobs R,\nQuirynen M. Computer-supported implant planning and guided surgery: a narrative review. Clin Oral Implants Res. 2015;26(suppl 11):69\u201376. doi:10.1111\/clr.12638"},{"key":"i1548-1336-52-3-185-b30","series-title":"Radiat Prot Dosimetry","first-page":"222","article-title":"Comparative study of image quality for MSCT and CBCT scanners for dentomaxillofacial radiology applications","volume":"129","author":"Loubele","year":"2008","unstructured":"Loubele M,\nMaes F,\nJacobs R,\nvan Steenberghe D,\nWhite SC,\nSuetens P. Comparative study of image quality for MSCT and CBCT scanners for dentomaxillofacial radiology applications. Radiat Prot Dosimetry. 2008;129:222\u2013226. doi:10.1093\/rpd\/ncn154"},{"key":"i1548-1336-52-3-185-b31","series-title":"Sci Rep","first-page":"2598","article-title":"Performance of novice versus experienced surgeons for dental implant placement with freehand, static guided and dynamic navigation approaches","volume":"13","author":"Wang","year":"2023","unstructured":"Wang X,\nShujaat S,\nMeeus J, et al. Performance of novice versus experienced surgeons for dental implant placement with freehand, static guided and dynamic navigation approaches. Sci Rep. 2023;13:2598. doi:10.1038\/s41598-023-29633-6"},{"key":"i1548-1336-52-3-185-b32","series-title":"Int J Oral Maxillofac Implants","first-page":"1159","article-title":"Fully guided versus half-guided and freehand implant placement: systematic review and meta-analysis","volume":"35","author":"Gargallo-Albiol","year":"2020","unstructured":"Gargallo-Albiol J,\nBarootchi S,\nMarqu\u00e9s-Guasch J,\nWang HL. Fully guided versus half-guided and freehand implant placement: systematic review and meta-analysis. Int J Oral Maxillofac Implants. 2020;35:1159\u20131169. doi:10.11607\/jomi.7942"},{"key":"i1548-1336-52-3-185-b33","series-title":"Int J Oral Maxillofac Implants","first-page":"305","article-title":"Accuracy in computer-aided implant surgery\u2013a review","volume":"21","author":"Widmann","year":"2006","unstructured":"Widmann G,\nBale RJ. Accuracy in computer-aided implant surgery\u2013a review. Int J Oral Maxillofac Implants. 2006;21:305\u2013313."},{"key":"i1548-1336-52-3-185-b34","series-title":"Clin Oral Implants Res","first-page":"1091","article-title":"Non-radiological method for three-dimensional implant position evaluation using an intraoral scan method","volume":"25","author":"von See","year":"2014","unstructured":"von See C,\nWagner MEH,\nSchumann P,\nLindhorst D,\nGellrich NC,\nStoetzer M. Non-radiological method for three-dimensional implant position evaluation using an intraoral scan method. Clin Oral Implants Res. 2014;25:1091\u20131093. doi:10.1111\/clr.12214"},{"key":"i1548-1336-52-3-185-b35","series-title":"J Prosthodontics","first-page":"730","article-title":"Digital workflow to merge an intraoral scan and CBCT of edentulous maxilla: a technical report","volume":"29","author":"Carosi","year":"2020","unstructured":"Carosi P,\nFerrigno N,\nDe Renzi G,\nLaureti M. Digital workflow to merge an intraoral scan and CBCT of edentulous maxilla: a technical report. J Prosthodontics. 2020;29:730\u2013732. doi:10.1111\/jopr.13221"}],"container-title":["Journal of Oral Implantology"],"original-title":[],"link":[{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/52\/3\/article-p185.xml","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/52\/3\/article-p185.xml","content-type":"text\/html","content-version":"vor","intended-application":"syndication"},{"URL":"https:\/\/joi.kglmeridian.com\/downloadpdf\/journals\/orim\/52\/3\/article-p185.xml","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,19]],"date-time":"2026-07-19T01:42:54Z","timestamp":1784425374000},"score":1,"resource":{"primary":{"URL":"https:\/\/joi.kglmeridian.com\/view\/journals\/orim\/52\/3\/article-p185.xml"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6]]},"references-count":35,"journal-issue":{"issue":"3"},"URL":"https:\/\/doi.org\/10.1563\/aaid-joi-d-25-00120","relation":{},"ISSN":["1548-1336","0160-6972"],"issn-type":[{"value":"1548-1336","type":"electronic"},{"value":"0160-6972","type":"print"}],"subject":[],"published":{"date-parts":[[2026,6]]}}}